IMF orientation, solar wind velocity, and Pc 3-4 signals - A joint distribution

Separate studies using the same micropulsation data base in the period range 10-150 s have shown earlier that signal levels recorded during September, October, and November 1969 at Calgary correlated positively with both solar-wind alignment of the IMF and solar-wind speed, but each correlation contained enough scatter to allow for the influence of the other factor. In this report, joint correlations of velocity and field direction with parameters representing hourly distributions rather than minima of IMF orientation angle display the relative effect of the two agents on magnetic pulsation signal levels. The joint correlations reduce the overall scatter and show that solar-wind speeds above 200-300 km/s and angles between the IMF and the sun-earth line of less than 50-60 deg are associated with enlarged magnetic pulsation amplitudes. These threshold effects tend to support both the bow-shock origin and the Kelvin-Helmholtz amplification of daytime signal transients in the Pc 3, 4 period ranges.

Greenstadt, E. W.↗

Use of two-dimensional transmission photoelastic models to study stresses in double-lap bolted joints: Load transfer and stresses in the inner lap

The determination of the stress distribution in the inner lap of double-lap, double-bolt joints using photoelastic models of the joint is discussed. The principal idea is to fabricate the inner lap of a photoelastic material and to use a photoelastically sensitive material for the two outer laps. With this setup, polarized light transmitted through the stressed model responds principally to the stressed inner lap. The model geometry, the procedures for making and testing the model, and test results are described.

Hyer, M. W.↗

Investigations into the mechanical behavior of composite bolted joints

Testing procedures and data reduction and interpretation techniques were established for a program to study the mechanical behavior of bolted joints at room temperature, -157 C (-250 F), and 315 C (600 F). The load transfer characteristics, from one bolt to another, in double-bolt joints were investigated by examining data generated in previous investigations. From the results, it appears the increase in load-carrying capacity by adding a second bolt in tandem can be predicted.

Perry, J. C.↗

Strain measurements in composite bolted-joint specimens

Strain data from a series of bolted joint tests is presented. Double lap, double hole, double lap, single hole, and open hole tensile specimens were tested and the strain gage locations, load strain responses, and load axial displacement responses are presented. The open hole specimens were gaged to determine strain concentration factors. The double lap, double hole specimens were gaged to determine the uniformity of the strain in the joint and the amount of load transferred past the first bolt. The measurements indicated roughly half the load passed the first bolt to be reacted by the second bolt.

Hyer, M. W.↗

Stereosat: A proposed private sector/government joint venture in remote sensing from space

Stereosat, a free flying Sun synchronous satellite whose purpose is to obtain worldwide cloud-free stereoscopic images of the Earth's land masses, is proposed as a joint private sector/government venture. A number of potential organization models are identified. The legal, economic, and institutional issues which could impact the continuum of potential joint private sector/government institutional structures are examined.

Anglin, R. L.↗

Ultimate strength of high-load-capacity composite bolted joints

Presented are the results of a series of tests initiated to obtain baseline data on the load-carrying capacity of bolted joints designed to carry large loads, specifically up to 222 kN (50 kips). The major testing purposes were to determine the load carrying capacity as a function of the width and thickness of the joint and the diameter and number of bolts, and to observe the failure mode. A total of 100 tests were conducted on three different specimen configurations. The specimens were fabricated from a T300/5208 fiber/resin system in a quasi-isotropic lay-up. The results presented indicate that for a given ratio of specimen width to hole diameter, the specimens with the smaller holes sustained a higher net-section tensile stress before failure. In addition, for a given ratio of specimen width to hole diameter, the thinner specimens withstood a higher net-section stress. No attempt has been made to correlate the results with theoretical predictions.

Hyer, M. W.↗

Stress analysis of bonded plates and joints

The paper presents a general numerical method of solution to the transverse normal stress and longitudinal shear stress distributions in the adhesive layers of bonded stiffener plates, double lap joints, and strap joints, all of dissimilar orthotropic adherends. The bending deformations and the transverse shear deformations are included in the analytical model. The present influence of bending deformations of adherends on both the normal and shear stresses in adhesive layers is discussed in detail for practical cases.

Yuceoglu, U.↗

Analysis and test of bonded single lap joints with preformed adherends

A theoretical and experimental study has been conducted to investigate the load transfer of a single lap joint where the adherends have been preformed so that the angle between the line of action of the applied in-plane force and the bond line is reduced. The preforming of the adherend reduces the moment resultant in the adherend at the edge of the overlap region which reduces both the maximum peel and shear stresses in the adhesive, and gives a more uniform shear distribution in the adhesive. An increase in static load transfer of up to 120 percent has been shown, and several orders of magnitude increase in fatigue life have been achieved with modest preform angles. Thus, sizeable benefits can be obtained in the fatigue life or additional load capacity of bonded single lap joints by preforming the adherends.

Sawyer, J. W.↗

Ball-and-Socket Joint Can Be Disassembled

Ball-and-socket joint originally developed for construction of large platforms in zero g could be used in such Earth-based temporary structures as scaffolding, camping equipment, tent posts, trade shows and displays. New joint consists of a socket mounted on central hub or union and ball-ended bolt or fitting mounted at end of a column or any structural member. Unit is self-contained, requires no loose hardware and is engaged or disengaged without tools manually, or remotely by a manipulator.

Totah, R. S.↗

Time-temperature effect in adhesively bonded joints

The viscoelastic analysis of an adhesively bonded lap joint was reconsidered. The adherends are approximated by essentially Reissner plates and the adhesive is linearly viscoelastic. The hereditary integrals are used to model the adhesive. A linear integral differential equations system for the shear and the tensile stress in the adhesive is applied. The equations have constant coefficients and are solved by using Laplace transforms. It is shown that if the temperature variation in time can be approximated by a piecewise constant function, then the method of Laplace transforms can be used to solve the problem. A numerical example is given for a single lap joint under various loading conditions.

Delale, F.↗

Mechanical characterization of PMR-15 graphite/polyimide bolted joints

Data are presented for the static and viscoelastic performance of Celion 6000/PMR-15 graphite/polyimide composite belted joints over the 21 to 315 C temperature range. Two laminate configurations were obtained by sectioning a panel into subpanels oriented parallel and perpendicular to the laminate principal direction. Three replicates of each specimen geometry were tested at each of the test temperatures for the two laminate configurations, and failure load was defined as the maximum load attained as indicated by the load/deflection curve. Effects of strain-rate on strength and failure mode behavior were assessed at room temperature for strain rates of 0.002, 0.01, 0.10, and 1.00/s, and creep behavior was examined for the case of bearing deformations at temperatures of 21 and 177 C. Results are presented, including: (1) two distinct mechanisms were responsible for bearing failure and related to laminate configuration, (2) the + or - 45 deg plies carried the shearing load in composite bolted joints, and (3) the material exhibited strain-rate sensitivity which varied with laminate configuration.

Wilson, D. W.↗

Self-Alining, Latching Joint For Folding Structural Elements

Structural column elements assembled quickly and easily with aid of new center joint. Joint alines column elements automatically and fastens them together securely. Tapered half columns are stacked like paper cups, unfolded, and connected to other similar elements to form truss structures.

Bush, H. G.↗

Analysis of interface cracks in adhesively bonded lap shear joints, part 4

Conservation laws of elasticity for nonhomogeneous materials were developed and were used to study the crack behavior in adhesively bonded lap shear joints. By using these laws and the fundamental relationships in fracture mechanics of interface cracks, the problem is reduced to a pair of linear algebraic equations, and stress intensity solutions can be determined directly by information extracted from the far field. The numerical results obtained show that: (1) in the lap-shear joint with a given adherend, the opening-mode stress intensity factor, (K sub 1) is always larger than that of the shearing-mode (K sub 2); (2) (K sub 1) is not sensitive to adherent thickness abut (K sub 2) increases rapidly with increasing thickness; and (3) (K sub 1) and (K sub 2) increase simultaneously as the interfacial crack length increases.

Wang, S. S.↗

Analysis of the shearout failure mode in composite bolted joints

A semi-empirical shearout strength model has been formulated for the analysis of composite bolted joints with allowance for the effects of joint geometry. The model employs a polynomial stress function in conjunction with a point stress failure criterion to predict strength as a function of fastener size, edge distance, and half spacing. The stress function is obtained by two-dimensional plane-stress finite element analysis using quadrilateral elements with orthotropic material properties. Comparison of experimentally determined shearout strength data with model predicted failures has substantiated the accuracy of the model.

Wilson, D. W.↗

Interface cracks in adhesively bounded lap-shear joints

A study on the elastic behavior of interface cracks in adhesively bonded lap-shear joints is presented. The problem is investigated by using a recently developed method of analysis based on conservation laws in elasticity for nonhomogeneous solids and fundamental relationships in fracture mechanics of dissimilar materials. The formulation leads to a pair of linear algebraic equations in mixed-mode stress intensity factors. Singular crack-tip stress intensity solutions are determined directly by information extracted from the far field. Stress intensity factors and associated energy release rates are obtained for various cases of interest. Fundamental nature of the interfacial flaw behavior in lap-shear adhesive joints is examined in detail.

Wang, S. S.↗

Inspecting Joints With Grooved Surfaces

Method of inspecting grooved joints covers full circumference of joint at its various depths. Inspection tools include guide block that holds fiberoptic scope with camera attached to its end and also holds light pipe with ultraviolet source attached to end.

Burns, B. S.↗

Effects of simulated lightning on composite and metallic joints

The effects of simulated lightning strikes and currents on aircraft bonded joints and access/inspection panels were investigated. Both metallic and composite specimens were tested. Tests on metal fuel feed through elbows in graphite/epoxy structures were evaluated. Sparking threshold and residual strength of single lap bonded joints and sparking threshold of access/inspection panels and metal fuel feed through elbows are reported.

Howell, W. E.↗

Electrical rotary joint apparatus for large space structures

A structural array and electrical rotary joint for transmitting an electrical power between large space structures having relative rotational movement is disclosed which includes large support framework structures which rotate relative to one another about a common axis of rotation. A rotary interface joint is defined between the structures. A cylindrical hub member is carried by one structure and a cylindrical hub member is carried by a support structure with a third hub member being concentrically within a fourth hub member for relative rotation. Tension connecting cables connect hub members with their associated outer structures whereby relative rotational movement between the structures is transmitted to the cylindrical hub members for unitary motion therewith. Electrical conductor brush members are carried by one hub and electrical contact rings are carried by another hub member in sliding electrical contact with the brushes for transmission of electrical power during relative rotational movement between the two support structures.

Belew, R. R.↗