Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “imaging systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

Development and Assessment of a New Particle Image Velocimetry System in the NASA GRC 225 cm2 Wind Tunnel

As part of an ongoing campaign to provide detailed and thorough measurements in a two-dimensional impinging shock-wave/boundary-layer interaction (SWBLI), a custom implementation of the Particle Image Velocimetry (PIV) measurement technique in the NASA Glenn 225 cm2 Wind Tunnel was constructed. The flow seeding apparatus was devised to locally seed the region of interest in the overall flowfield to avoid coating the viewing window with seed material. The ability of the PIV system to provide small particles which faithfully track the underlying gas-phase flowfield was of key importance for the success of this system to make quality measurements in the SWBLI flowfield. In order to optimize and assess the performance of the particle seeding system, PIV measurements were made across a planar oblique shock wave and particle response was analyzed to quantify the particle lag effects due to the finite inertia of the seed droplets. Video recordings from a camera placed in the wind tunnel plenum tank were also used to discern the near-field behavior of the seeded plume and guide the design evolution of the seeding apparatus. The resulting optimized seeding configuration was applied to make PIV measurements in the wind tunnel test section boundary layer to assess the seed particle spatial coverage and concentration. This sample boundary layer dataset provides an analog to the eventual boundary layer measurements to be made in the axisymmetric test section under much more challenged viewing conditions.

PIV↗

Development and Assessment of a New Particle Image Velocimetry System in the NASA GRC 225 cm2 Wind Tunnel

As part of an ongoing campaign to provide detailed and thorough measurements in a two-dimensional impinging shock-wave/boundary-layer interaction (SWBLI), a custom implementation of the Particle Image Velocimetry (PIV) measurement technique in the NASA Glenn 225 cm2 Wind Tunnel was constructed. The flow seeding apparatus was devised to locally seed the region of interest in the overall flowfield to avoid coating the viewing window with seed material. The ability of the PIV system to provide small particles which faithfully track the underlying gas-phase flowfield was of key importance for the success of this system to make quality measurements in the SWBLI flowfield. In order to optimize and assess the performance of the particle seeding system, PIV measurements were made across a planar oblique shock wave and particle response was analyzed to quantify the particle lag effects due to the finite inertia of the seed droplets. Video recordings from a camera placed in the wind tunnel plenum tank were also used to discern the near-field behavior of the seeded plume and guide the design evolution of the seeding apparatus. The resulting optimized seeding configuration was applied to make PIV measurements in the wind tunnel test section boundary layer to assess the seed particle spatial coverage and concentration. This sample boundary layer dataset provides an analog to the eventual boundary layer measurements to be made in the axisymmetric test section under much more challenged viewing conditions.

PIV↗

New detector for use in fast neutron radiography

We have developed and tested a new type detector for use in the fast neutron (FN) imaging radiography applications. FN radiography is generally used for nondestructive material testing, medical and biology applications, border patrol, transportation and cargo screening tasks. It is complementary to other types of radiography, providing additional information on light element content of the material samples. Distinct from other FN imagers presently known, our device implements a neutron-sensitive scintillator attached to a position-sensitive photomultiplier tube (PSPMT), and operates in an event-by-event readout mode, acquiring energy, timing, and pulse shape information for all detected radiation events. The information is used to help separate events of FN interactions in the scintillator from the background events caused by the electronics noise and by the other types of background radiation. Selection of pure fast neutron events in the final image allows us to achieve ultimate image contrast and resolution, as compared with other types of FN imaging devices operating most commonly in an integration mode, in which the detector?s dark noise and radiation background dilute the images. The detector performance for FN imaging application was tested using D-D neutron generator, designed and manufactured by Adelphi Technology, Inc. This essentially point-like neutron source operates in continuous mode producing up to 109 of 2.5 MeV neutrons per second. Samples made of metals plastic and other material were used to measure the detector resolution, efficiency and uniformity. Results of these tests are presented and discussed. Fig. 1 shows one of the test FN radiographic images obtained using the sample made of 11 styrene plastic strips. All strips are squares 4.8 x 4.8 mm2 with six different lengths 10 to 60 mm with 10 mm increment. [A] [B] [C] Fig. 1. [A]-layout of the test sample; [B]-raw FN shadow image of the sample; [C]-map of the plastic strips as they appear on the image, with measured FN absorption factor shown in percent. Both X and Y position resolution of the FN imaging detector are estimated to be less than 0.5 mm (sigma) based on the analysis of the edges of the strip shadows in the plot. Because this detector shows the fraction-of-a-millimeter resolution desirable for most of FN applications, and is built using radiation hard materials, we believe it could be a good alternative to other FN imaging systems based on CCD or solid state detectors. In addition, having a sub-nanosecond timing resolution, it is suitable for the time-of-flight energy-resolved FN imaging.

Popov, V.↗

System and method for compact, adaptive optical sensor for obtaining areal images

The present disclosure relates to an imaging system which may make use of an electronic controller, a digital micromirror array, an aperture control system and a detector to image a desired scene. The digital micromirror array has a plurality of micromirror elements responsive to control signals generated by the electronic controller for electronically aiming the micromirror elements in a desired direction to image the desired area, and for receiving and reflecting light emanating from the desired area. The aperture control system receives light reflected from the digital micromirror array and passes a predetermined subportion of the received light therethrough. The detector is responsive to the predetermined subportion of light.

Panas, Robert Matthew↗

Advanced Millimeter-Wave Security Portal Imaging Techniques

Millimeter-wave imaging is rapidly gaining acceptance for passenger screening at airports and other secured facilities. This paper details a number of techniques developed over the last several years including novel image reconstruction and display techniques, polarimetric imaging techniques, array switching schemes, as well as high frequency high bandwidth techniques. Implementation of some of these methods will increase the cost and complexity of the mm-wave security portal imaging systems. RF photonic methods may provide new solutions to the design and development of the sequentially switched linear mm-wave arrays that are the key element in the mm-wave portal imaging systems.

99 GENERAL AND MISCELLANEOUS↗

Spherical time-encoded radiation imaging simulations

Radiation source localization is important for nuclear nonproliferation and can be obtained using time-encoded imaging systems with unsegmented detectors. A scintillation crystal can be used with a moving coded-aperture mask to vary the detected count rate produced from radiation sources in the far field. The modulation of observed counts over time can be used to reconstruct an image with the known coded-aperture mask pattern. Current time-encoded imaging systems incorporate cylindrical coded-aperture masks and have limits to their fully coded imaging field-of-view. This work focuses on expanding the field-of-view to 4π by using a novel spherical coded-aperture mask. A regular icosahedron is used to approximate a spherical mask. This icosahedron consists of 20 equilateral triangles; the faces of which are each subdivided into four equilateral triangle-shaped voxels which are then projected onto a spherical surface, creating an 80-voxel coded-aperture mask. Furthermore, these polygonal voxels can be made from high-Z materials for gamma-ray modulation and/or low-Z materials for neutron modulation. In this work, we present Monte Carlo N-Particle (MCNP) simulations and simple models programmed in Mathematica to explore image reconstruction capabilities of this 80-voxel coded-aperture mask.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Imaging the dome of Santa Maria del Fiore using cosmic rays

The dome of Santa Maria del Fiore, Florence Cathedral, was built between 1420 and 1436 by architect Filippo Brunelleschi and it is now cracking under its own weight. Engineering efforts are under way to model the dome's structure and reinforce it against further deterioration. According to some scholars, Brunelleschi might have built reinforcement structures into the dome itself; however, the only known reinforcement is a wood chain 7.75 m above the springing of the Cupola. Multiple scattering muon radiography is a non-destructive imaging method that can be used to image the interior of the dome's wall and therefore ascertain the layout and status of any iron substructure in it. A demonstration measurement was performed at the Los Alamos National Laboratory on a mock-up wall to show the feasibility of the work proposed, and a lightweight and modular imaging system is currently under construction. Here, we will discuss here the results of the demonstration measurement and the potential of the proposed technique, describe the imaging system under construction and outline the plans for the measurement.

47 OTHER INSTRUMENTATION↗

Characterizing Density and Complexity of Imported Cargos

X-ray inspection systems are used to detect radiological and nuclear threats in imported cargo. In order to better understand performance of these systems, system imaging capabilities and the characteristics of imported cargo need to be determined. This project involved calculation of the modulation transfer function as a metric of system imaging performance and a study of the density and inhomogeneity of imported cargos, which have been shown to correlate with human analysts, threat detection performance.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Development of an image converter of radical design

A long term investigation of thin film sensors, monolithic photo-field effect transistors, and epitaxially diffused phototransistors and photodiodes to meet requirements to produce acceptable all solid state, electronically scanned imaging system, led to the production of an advanced engineering model camera which employs a 200,000 element phototransistor array (organized in a matrix of 400 rows by 500 columns) to secure resolution comparable to commercial television. The full investigation is described for the period July 1962 through July 1972, and covers the following broad topics in detail: (1) sensor monoliths; (2) fabrication technology; (3) functional theory; (4) system methodology; and (5) deployment profile. A summary of the work and conclusions are given, along with extensive schematic diagrams of the final solid state imaging system product.

Irwin, E. L.↗

Low-speed flowfield characterization by infrared measurements of surface temperatures

An experimental program was aimed at identifying areas in low speed aerodynamic research where infrared imaging systems can make significant contributions. Implementing a new technique, a long electrically heated wire was placed across a laminar jet. By measuring the temperature distribution along the wire with the IR imaging camera, the flow behavior was identified. Furthermore, using Nusselt number correlations, the velocity distribution could be deduced. The same approach was used to survey wakes behind cylinders in a wind-tunnel. This method is suited to investigate flows with position dependent velocities, e.g., boundary layers, confined flows, jets, wakes, and shear layers. It was found that the IR imaging camera cannot accurately track high gradient temperature fields. A correlation procedure was devised to account for this limitation. Other wind-tunnel experiments included tracking the development of the laminar boundary layer over a warmed flat plate by measuring the chordwise temperature distribution. This technique was applied also to the flow downstream from a rearward facing step. Finally, the IR imaging system was used to study boundary layer behavior over an airfoil at angles of attack from zero up to separation. The results were confirmed with tufts observable both visually and with the IR imaging camera.

Gartenberg, E.↗

Computational imaging using a mode-mixing cavity at microwave frequencies

We present a 3D computational imaging system based on a mode-mixing cavity at microwave frequencies. The core component of this system is an electrically large rectangular cavity with one corner re-shaped to catalyze mode mixing, often called a Sinai Billiard. The front side of the cavity is perforated with a grid of periodic apertures that sample the cavity modes and project them into the imaging scene. The radiated fields are scattered by the scene and are measured by low gain probe antennas. The complex radiation patterns generated by the cavity thus encode the scene information onto a set of frequency modes. Assuming the first Born approximation for scattering dynamics, the received signal is processed using computational methods to reconstruct a 3D image of the scene with resolution determined by the diffraction limit. The proposed mode-mixing cavity is simple to fabricate, exhibits low losses, and can generate highly diverse measurement modes. The imaging system demonstrated in this letter can find application in security screening and medical diagnostic imaging.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Remote-Imaging Parameters

Image resolution, image quality and data transmission rate of remote imaging systems continuously controlled by operator intervention. Set of levers allows operator to control independently frame rate, frame size and image quality in bits per pixel. System used for imaging systems in aircraft or remotely piloted vehicles.

Rice, R. F.↗

Implosion dynamics measurements by monochromatic x-ray radiography in inertial confinement fusion

The implosion dynamics is the most important metrics for assessing the progress toward ignition of an inertially confined fusion experiment. A high spatial resolution monochromatic x-ray imaging system based on the spherically bent crystal is developed to measure the implosion trajectory. The density distribution of the imploding capsules can be inferred with more accurately from monochromatic trajectories. The self emission of the imploded core will be restrained by spectral resolution and the setup of the imaging system. Also the variations of the backlighters' intensity will not be seen in the images. It has been demonstrated on SGII laser facility at the first time. The ablator remaining mass and the implosion velocity, which are the important ablator parameters, are calculated from the monochromatic trajectories. And the results are contrasted to the 1D hydrodynamics simulations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Accuracy of an infrared marker-based patient positioning system (ExacTrac®) for stereotactic body radiotherapy in localizing the planned isocenter using fiducial markers

Stereotactic Body Radiation Therapy (SBRT) requires a controlled immobilization and position monitoring of patient and target. The purpose of this work is to analyze the performance of the imaging system ExacTrac® (ETX) using infrared and fiducial markers. Materials and methods: In order to assure the accuracy of isocenter localization, a Quality Assurance procedure was applied using an infrared marker-based positioning system. Scans were acquired of an inhouse-agar gel and solid water phantom with infrared spheres. In the inner part of the phantom, three reference markers were delineated as reference and one pellet was place internally; which was assigned as the isocenter. The iPlan® RT Dose treatment planning system. Images were exported to the ETX console. Images were acquired with the ETX to check the correctness of the isocenter placement. Adjustments were made in 6D the reference markers were used to fuse the images. Couch shifts were registered. The procedure was repeated for verification purposes. Results: The data recorded of the verifications in translational and rotational movements showed averaged 3D spatial uncertainties of 0.31 ± 0.42 mm respectively 0.82° ± 0.46° in the phantom and the first correction of these uncertainties were of 1.51 ± 1.14 mm respectively and 1.37° ± 0.61°. Conclusions: This study shows a high accuracy and repeatability in positioning the selected isocenter. The ETX-system for verifying the treatment isocenter position has the ability to monitor the tracing position of interest, making it possible to be used for SBRT positioning within uncertainty ≤1mm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Sci-Thur AM: YIS – 07: Optimizing dual-energy x-ray parameters using a single filter for both high and low-energy images to enhance soft-tissue imaging

Objective: To optimize dual-energy parameters of ExacTrac stereoscopic x-ray imaging system for lung SBRT patients Methods: Simulated spectra and a lung phantom were used to optimize filter material, thickness, kVps, and weighting factors to obtain bone subtracted dual-energy images. Spektr simulations were used to identify material in the atomic number (Z) range [3–83] based on a metric defined to separate spectrums of high and low energies. Both energies used the same filter due to time constraints of image acquisition in lung SBRT imaging. A lung phantom containing bone, soft tissue, and a tumor mimicking material was imaged with filter thicknesses range [0–1] mm and kVp range [60–140]. A cost function based on contrast-to-noise-ratio of bone, soft tissue, and tumor, as well as image noise content, was defined to optimize filter thickness and kVp. Using the optimized parameters, dual-energy images of anthropomorphic Rando phantom were acquired and evaluated for bone subtraction. Imaging dose was measured with dual-energy technique using tin filtering. Results: Tin was the material of choice providing the best energy separation, non-toxicity, and non-reactiveness. The best soft-tissue-only image in the lung phantom was obtained using 0.3 mm tin and [140, 80] kVp pair. Dual-energy images of the Rando phantom had noticeable bone elimination when compared to no filtration. Dose was lower with tin filtering compared to no filtration. Conclusions: Dual-energy soft-tissue imaging is feasible using ExacTrac stereoscopic imaging system utilizing a single tin filter for both high and low energies and optimized acquisition parameters.

60 APPLIED LIFE SCIENCES↗

Integrative Quantitative-Phase and Airy Light-Sheet Imaging

Light-sheet microscopy enables considerable speed and phototoxicity gains, while quantitative-phase imaging confers label-free organelle recognition and metabolic information that are inaccessible by conventional methods. We report the fusion of these two modalities onto a standard inverted microscope that retains compatibility with microfluidics. We describe the utilization of an accelerating Airy-beam light-sheet yielding identical imaging areas with interferometry, and an application in unmasking the effects of cellular noise on metabolic compartmentalization.

Biological sciences, Biological techniques, Micros↗

Understanding the Response of Photosynthetic Metabolism in Tropical Forests to Seasonal Climate Variations

We propose a study focused on the basic question: What controls the response of photosynthesis in Amazonian forests to seasonal variations in climate? This question, despite its apparent simplicity, remains difficult for modern earth system models to answer, and is also the subject of continuing controversy in the remote-sensing literature. For example, in the modeling arena, four cutting-edge earth system models (ESM’s) show significant divergence in their seasonal patterns of photosynthesis from observed whole-system photosynthetic fluxes at two sites in the central Amazon. The overall objective of the project is to guide improvements in earth system models of tropical forest photosynthesis by collecting and integrating a suite of observations to 1) test several hypotheses (three core, conceptual hypotheses for explaining observed photosynthetic seasonality and a methodological hypotheses for scaling from leaves to canopy with hyperspectral cameras), and 2) perform a synthesis activity that applies our empirical work to earth system models of terrestrial carbon cycling. The project will provide an extensive suite of new and unique datasets that enable us to fill, through advanced modeling techniques and analysis, critical knowledge gaps in current understanding of what controls the response of canopy photosynthesis and related functions in Amazonian forests to seasonal variation in climate. Three major types of datasets and data products will be delivered: (1) in situ leaf and tree-scale measurements from intensive ecophysiological and ecohydological field campaigns, (2) time-series observations of leaf-to-crown scale forest reflectance properties and atmospheric radiation from two innovative, ground-based imaging sensors (respectively, the Hyperspectral Vegetation Imaging System and the High Dynamic Range All-Sky Imaging System), and (3) results from state-of-the-art models of 3-dimensional canopy processes for radiative transfer and photosynthesis that integrate and link our observations to tropical forest processes. These data products and the improved knowledge we achieve with them will contribute to testing and improving the treatment of tropical forest processes in ESMs. They will contribute data to and leverage related data from of the GOAmazon campaign, and make significant contributions to support the overall goals of GOAmazon. This work will also help establish a foundation for the Next Generation Ecosystem Experiments (NGEE) in the Tropics.

54 ENVIRONMENTAL SCIENCES↗

Helicopter flights with night-vision goggles: Human factors aspects

Night-vision goggles (NVGs) and, in particular, the advanced, helmet-mounted Aviators Night-Vision-Imaging System (ANVIS) allows helicopter pilots to perform low-level flight at night. It consists of light intensifier tubes which amplify low-intensity ambient illumination (star and moon light) and an optical system which together produce a bright image of the scene. However, these NVGs do not turn night into day, and, while they may often provide significant advantages over unaided night flight, they may also result in visual fatigue, high workload, and safety hazards. These problems reflect both system limitations and human-factors issues. A brief description of the technical characteristics of NVGs and of human night-vision capabilities is followed by a description and analysis of specific perceptual problems which occur with the use of NVGs in flight. Some of the issues addressed include: limitations imposed by a restricted field of view; problems related to binocular rivalry; the consequences of inappropriate focusing of the eye; the effects of ambient illumination levels and of various types of terrain on image quality; difficulties in distance and slope estimation; effects of dazzling; and visual fatigue and superimposed symbology. These issues are described and analyzed in terms of their possible consequences on helicopter pilot performance. The additional influence of individual differences among pilots is emphasized. Thermal imaging systems (forward looking infrared (FLIR)) are described briefly and compared to light intensifier systems (NVGs). Many of the phenomena which are described are not readily understood. More research is required to better understand the human-factors problems created by the use of NVGs and other night-vision aids, to enhance system design, and to improve training methods and simulation techniques.

Brickner, Michael S.↗