Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “heat utilization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

Benefits of Dual Fuel Heat Pump Grid-responsive Control: A Model-based Control Optimization Approach Using Building and Equipment Co-simulation

Conventional dual fuel heat pumps lack the intelligent control mechanisms to efficiently manage the switch between heat pump and furnace, leading to sub-optimal energy usage and, in some cases, increased operating costs. To resolve this gap, this study applies optimized control on hybrid heat pumps. With a focus on equipment control strategies, we compare the performances of five spacing heating equipment, including a conventional heat pump (HP), a conventional furnace, a dual fuel heat pump (DFHP) with conventional control, a dual fuel heat pump with smart control, and a novel seamlessly fuel flexible heat pump (SFFHP). While DFHP runs on either gas or electricity at any given moment, SFFHP concurrently consumes gas and electricity by continuously optimizing the proportion of each. In this research, a co-simulation framework is developed by integrating a building envelope model with a physics-based heat pump simulation model to analyze the benefits of grid-responsive controls of DFHP and SFFHP. The model-based optimal controls adjust the operation of the heat pump and gas furnace based on utility price signals and marginal grid emission to minimize utility cost and CO 2 emissions for multiple climate zones, different utility tariffs, and marginal grid emission scenarios. Case studies in Chicago and Los Angeles demonstrate that SFFHP and DFHP, with model-based optimal control, can deliver significant reductions in peak demand, utility cost, and CO 2 emission. In Chicago, SFFHP and smart controlled DFHP yield up to 64.7% and 61.7% utility cost reduction and up to 15.7% and 8.5% CO 2 emission reduction compared to the gas furnace. In Los Angeles, SFFHP and smart controlled DFHP achieve up to 43.6% and 40.1% utility cost reduction and up to 13.8% and 14.1% CO2 emission reduction compared to conventional heat pumps. In conclusion, by leveraging the fuel flexibility nature of dual fuel heat pumps, the model-based control optimization approach makes dual fuel heat pump an attractive option for demand response programs.

Control↗

Combining Satellite Microwave Radiometer and Radar Observations to Estimate Atmospheric Latent Heating Profiles

In this study, satellite passive microwave sensor observations from the TRMM Microwave Imager (TMI) are utilized to make estimates of latent + eddy sensible heating rates (Q1-QR) in regions of precipitation. The TMI heating algorithm (TRAIN) is calibrated, or "trained" using relatively accurate estimates of heating based upon spaceborne Precipitation Radar (PR) observations collocated with the TMI observations over a one-month period. The heating estimation technique is based upon a previously described Bayesian methodology, but with improvements in supporting cloud-resolving model simulations, an adjustment of precipitation echo tops to compensate for model biases, and a separate scaling of convective and stratiform heating components that leads to an approximate balance between estimated vertically-integrated condensation and surface precipitation. Estimates of Q1-QR from TMI compare favorably with the PR training estimates and show only modest sensitivity to the cloud-resolving model simulations of heating used to construct the training data. Moreover, the net condensation in the corresponding annual mean satellite latent heating profile is within a few percent of the annual mean surface precipitation rate over the tropical and subtropical oceans where the algorithm is applied. Comparisons of Q1 produced by combining TMI Q1-QR with independently derived estimates of QR show reasonable agreement with rawinsonde-based analyses of Q1 from two field campaigns, although the satellite estimates exhibit heating profile structure with sharper and more intense heating peaks than the rawinsonde estimates. 2

Grecu, Mircea↗

Comparative Analysis of Thermal Conversion Technologies for Deep Space Missions

Radioisotope power systems (RPS) utilizing Plutonium-238 as a heat source for thermal-to-electric energy conversion have been used as a reliable power source for NASA’s deep space missions for sixty years. Recent innovations and improvements to thermal energy technologies show potential increases to radioisotope system efficiencies from current measurements of ~5-7% to efficiencies upwards of 20%. This report surveys and ranks recent, innovative thermal-to-electric energy conversion research technologies. Technologies being developed at universities and industry are compared with respect to thermal conversion method and relevant key performance parameters. Key performance parameters are identified as system specific power per kg, efficiency, power output, technology readiness level, and system mass. Analytical Hierarchy Process (AHP) was utilized to create weighted values for each evaluation criterion. The AHP tables combined with decision matrices create table scores for past, present, and potential future systems. The table score was combined with a conversion method score in an adjustable system to add value to flight-proven or well-tested thermal conversion technologies such as thermoelectrics. While the three highest-ranking systems reviewed are currently being developed by NASA’s RPS Program, the additional highest-ranking systems not under-development by RPS could warrant further research.

Radioisotope Power System↗

Pioneering Heat Pump Project

This project was initiated at a time when ground coupled heat pump systems in this region were limited in size and quantity. There were economic pressures with costs for natural gas and electric utilities that had many organizations considering ground coupled heat pumps; The research has added to the understanding of how ground temperatures fluctuate seasonally and how this affects the performance and operation of the heat pumps. This was done by using a series of temperature sensors buried within the middle of one of the vertical bore fields with sensors located at various depths below grade. Trending of the data showed that there is a lag in ground temperature with respect to air temperatures in the shoulder months, however as full cooling and heating season arrives, the heat rejection and heat extraction from the ground has a significant effect on the ground temps; Additionally it is better understood that while a large community geothermal bore field serving multiple buildings does provide a convenient central plant to use, it introduces complexity of not being able to easily model and predict how each building will contribute to the loads in real time. Additional controllers and programming were added to provide more insight into this real time load profile and allow for intelligent shedding of load via a dry cooler during cool nights in lieu of rejecting to the ground loop. This serves as a means to ‘condition’ the ground loop and mitigate thermal creep of the field, as is typically observed; and It has been observed when compared to traditional heating and cooling equipment, there is still a cost premium to use ground source heat pumps that is driven mostly by the cost for vertical bore holes. Horizontal loop systems are less costly to install, but do not perform as well in this climate zone for heating mode

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Remote Alaska Communities Energy Efficiency Competition: Energy Efficiency for the Gem of the Yukon (Final Report)

Over the past decade, the City of Ruby has been proactive in working to reduce cost and energy use in the community. Ruby (Tl’aa’ologhe) is a remote city in Alaska located on the south bank of the Yukon River near the Kilbuck-Kuskokwim Mountains, about 50 air miles east of Galena and 230 air miles west of Fairbanks. As of 2019, the community has a population of over 150 people and most of Ruby’s residents are Koyukon Athabascan. Ruby has a long history of promoting local efficiency and clean energy in an effort to become more sustainable. Between 2007-2010, the community hosted Alaska’s first demonstration of an in-river hydrokinetic test project, sponsored by the Yukon River Inter-Tribal Watershed Council. In 2011, a 5kW solar photo-voltaic (PV) array was installed by the Interior Regional Housing Authority. In 2012, the community had a new power plant constructed by the Alaska Energy Authority that supplies waste heat to the washeteria, clinic and public safety garage, saving the community more than 4,000 gallons of heating fuel per year. The clinic, constructed by the Tanana Chiefs Conference, is one of the most energy efficient buildings in the interior and utilizes new building efficiency standards that were passed by the tribes. It has a 5kW solar PV array that provides energy into the local electric grid and offsets approximately 20% of the annual energy use. Building on this legacy, the City of Ruby entered into Department of Energy’s (DOE’s) Remote Alaska Communities Energy Efficiency Competition (RACEE) in 2016, pledging to reduce per-capita energy use 15% by 2020. During the second phase of the competition, 13 communities including Ruby were provided funding for tailored technical assistance to measure energy use and create energy efficiency plans.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Waterproof Raised Floor Makes Utility Lines Accessible

Floor for laboratories, hospitals and factories waterproof yet allows access to subfloor utilities. Elevated access floor system designed for installations with multitude of diverse utility systems routed under and up through floor and requirement of separation of potentially conflicting utility services. Floor covered by continuous sheet of heat resealable vinyl. Floor system cut open when changes are made in utility lines and ducts. After modifications, floor covering resealed to protect subfloor utilities from spills and leaks.

Cohen, M. M.↗

Multiphysics Analysis of the MSRE Experiment Using Griffin-SAM Coupled Code System

Molten salt reactors (MSRs) with flowing fuel have the unique feature of utilizing the fuel salt for heat generation and extraction at the same time since the fuel salt is circulating through the whole primary loop of the reactor. This movement of the fuel salt results in a partial decay of the delayed neutron precursors (DNPs) outside the core and corresponding redistribution in the active core region. To capture this phenomenon accurately, neutronics and thermal hydraulics computational tools need to be modified to handle the movement of the DNPs and their decay. Idaho and Argonne National Laboratories are actively working on developing neutronics and thermal hydraulics tools to model MSRs with flowing fuel. The neutronics code Griffin and the thermal hydraulics code SAM were extended to handle flowing fuel with the drift of the DNPs under the MOOSE framework. In this work, a simplified Multiphysics model of the Molten Salt Reactor Experiment (MSRE) is developed and utilized to perform steady-state and transient analyses. The MSRE experiments were designed to show the impact of the DNPs losses on core reactivity. The following section provides a description of the MSRE experiment with the core main parameters used to develop the model. Then, the developed Multiphysics model of the MSRE is presented. Finally, steady-state verification tests and unprotected loss of flow transient tests are discussed followed by a summary and conclusions.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Heat pipes and their use in technology

Heat pipes may be employed as temperature regulators, heat diodes, transformers, storage batteries, or utilized for transforming thermal energy into mechanical, electric, or other forms of energy. General concepts were established for the analysis of the transfer process in heat pipes. A system of equations was developed to describe the thermodynamics of steam passage through a cross section of a heat pipe.

Vasilyev, L.↗

Characterization of ash deposition and heat transfer behavior of coals during combustion in a pilot-scale facility and full-scale utility

Experimental measurements as well as theoretical models were used to investigate the impact of mineral matter of three coals on ash deposition and heat transfer for pulverized coal fired boilers. The ash deposition experiments were conducted in a pulverized fuel combustion pilot-scale facility and a full-scale unit. A mathematical model with input from computer-controlled scanning electron microscopy analysis of coal minerals was used to predict the effect of ash deposition on heat transfer. The predicted deposit thickness and heat flux from the model are shown to be consistent with the measurements in the test facility. The model differentiates the coals according to the deposits they form and their effect on heat transfer. The heat transfer predictions in the full-scale unit were found to be most suitable for the water wall under the furnace nose. The study demonstrates that the measurements in a full-scale unit can differ significantly from those in pilot-scale furnaces due to soot-blowing operations. 9 refs., 12 figs., 3 tabs.

01 COAL, LIGNITE, AND PEAT↗

Energy demand reduction in the built environment using shallow geothermal integrated energy systems: Part II – Hybrid ground source heat pump for building heating

The research collection aims at finding the various possible opportunities for the effective integration of shallow geothermal energy (SGE) to decrease the energy demand in the built environment and to reduce emission associated with it. The direct utilization of SGE using a ground source heat pump (GSHP) has been reviewed in comprehensive review part I and part II. From the extensive review, we have found that the hybrid GSHP is needed to avoid ground thermal imbalance and peak demand. Hybrid GSHP can adopt various supplemental heat sources and sinks according to the local climatic conditions and the balance of energy demands. The primary focus on the integration of subsystems such as biomass, solar energy (PV, PVT, and collector), phase change material, micro gas turbine, and absorption heat pump with GSHP is presented for heating application. This comprehensive review part III highlights the recent research findings and a potential gap in hybrid GSHP for further research and developments

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Comparative Analysis of HEATNETS for Geothermal Network Performance

Thermal energy networks (TENs), also known as 5th generation district energy systems, or more specifically geothermal networks when exchanging heat with geothermal boreholes, are an important technology for decarbonization. In these networks an ambient loop connects buildings and thermal sources, such as a borehole field, to exchange energy and maintain a desired loop temperature. Water-source heat pumps are used at the buildings to connect to the ambient or thermal loop to meet to the building heating and cooling loads and maintain comfort. A semi-transient, reduced-order technical model and techno-economic model, called HEATNETS, has been developed at NREL that captures the flow of energy around a TEN. In this work, a comparison of the HEATNETS technical model and a well-known coding platform used for modeling geothermal networks, TRNSYS, has been completed for a proposed geothermal network as a verification and validation process. Hourly data provided from the TRNSYS simulation included building loads, pumping power, heat pump power, temperature entering and leaving the borehole field, and mass flow rates. The hourly borehole temperatures were used to create a linear regression model utilized in HEATNETS to estimate the borehole field heat exchange. The building loads and mass flow rates were direct inputs to HEATNETS while the pumping power, heat pump power, borehole temperatures, and coefficients of performance were all simulated and calculated by HEATNETS, allowing for direct comparison of the thermal energy transfer HEATNETS considers the full process from design inputs to economic outputs and can provide modeling options for high-level initial system design and operational optimization. This study focuses on a validation of HEATNETS using results from TRNSYS. HEATNETS is not intended to replace other modeling tools, but this work demonstrates, via a comparison with an industry standard code, that HEATNETS can be a unique, high-level and rapid modeling tool for estimating the performance of a full geothermal network system.

15 GEOTHERMAL ENERGY↗

Measurement of Convective Heat Transfer Coefficients with Supercritical CO2 in Novel Additively Manufactured Helically Patterned Pin Fin Tubes Using the Wilson Plot Technique

This paper describes the measurement of convective heat transfer coefficients and friction factors for sCO2 flowing in pin-fin patterned pipes in the Heat Exchange and Experimental Testing (HEET) facility at the US DoE’s National Energy Technology Laboratory (NETL) in Morgantown, WV. The measurement procedures in the HEET rig were validated by conducting benchmark tests with smooth stainless-steel tube and comparing the results with published correlations for Nusselt number (Nu) and friction factor. Over typical Reynolds number range in sCO2, the measured Nu and friction factors were within 7% of classical correlations for smooth tube flow.The candidate pin fin patterned pipes were additively manufactured (AM) at the Oak Ridge National Laboratory. The pins were circular or elliptical in cross-section. Pin length to diameter aspect ratios were 1.33 and 2, while the pin diameter to tube diameter ratio was 0.188 and 0.125. Tests were performed for ReD varying from 6.9×104 to 2.2×105 and at conditions equivalent to the low pressure outlet (8.69 MPa, 361 K) of the low temperature recuperator (LTR) in an indirect sCO2 power cycle. The Wilson plot technique was utilized to measure the bulk heat transfer coefficients.For the better performing design (tube A, pin length to tube diameter ratio: 1.33, pin diameter to tube diameter ratio: 0.188), the local heat transfer coefficient increased by 112% relative to the Dittus-Boelter correlation at the LTR low pressure outlet. This corresponded to a 282% increase in the product of the heat transfer coefficient and the surface area. Large pressure drops across the test articles were observed.

Searle, Matthew↗

The impact of TXV heating on the performance of air-source heat pump in heating mode

The paper discusses the strategy of TXV heating, which adds a limited amount of heat on the surface of TXV sensor, to achieve energy saving and low cost in air-source heat pumps. The TXV heating is able to retard the valve closing so as to boost energy saving in heating mode. The testing results demonstrate the appropriate TXV heating achieves a remarkable improvement in COP and thermal comfort. The required heating power is not more than 40w. The additional equipment cost of TXV heating is less than $20. Thus, the strategy of TXV heating is practical from the view of technology and economy.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Survey of Hearth Products in U.S. Homes

There are over 7 million gas-fired fireplaces currently installed in US households. On an annual basis, these use substantial energy. However, the details of the fireplace energy use and the factors that influence it are currently not well understood. Fireplaces are a type of hearth product, which is a product category that primarily consists of fireplaces, stoves, and gas log sets. For the purpose of this study, the fuels used in hearth products are primarily natural gas, propane, or electricity. They may be vented or unvented. This study reports the results of a web survey of 2,100 respondents in the United States performed in February 2016. The responses were cleaned and weighted using the raking method to form a nationally representative population. The reported data include hearth product characteristics, usage information, and repair and maintenance practices. The hearth product characteristics include the hearth product type, fuel type, ignition system type, features, venting, and installation details. The usage information includes seasonal usage of the main burner and standing pilot (if present), daily usage, and the primary utility (whether decorative or for heating). These raw data are further processed and combined with values from the literature to estimate the annual operating hours and energy use and to assess how these are impacted by the hearth product type, features, age, and the main heating appliance, if present. Based on the survey responses, the estimated average annual hours of usage was 234 for the main burner, and 4,593 for the standing pilot. The results presented provide the most comprehensive data regarding hearth products in the United States published to date. These new data allow for an improved understanding of hearth products’ energy use, which in turn may facilitate the development of more informed analyses, and ultimately more efficient hearth products and reduced energy use. These new data also provide insight into topics not previously studied, such as the effect of hearth product features on energy use.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Affordable Rankine Cycle Waste Heat Recovery for Heavy Duty Trucks

Nearly 30% of fuel energy is not utilized and wasted in the engine exhaust. Organic Rankine Cycle (ORC) based waste heat recovery (WHR) systems offer a promising approach on waste energy recovery and improving the efficiency of Heavy-Duty diesel engines. Major barriers in the ORC WHR system are the system cost and controversial waste heat recovery working fluids. More than 40% of the system cost is from the additional heat exchangers (recuperator, condenser and tail pipe boiler). The secondary working fluid loop designed in ORC system is either flammable or environmentally sensitive. The Eaton team investigated a novel approach to reduce the cost of implementing ORC based WHR systems to Heavy-Duty (HD) Diesel engines while utilizing safest working fluids. Affordable Rankine Cycle (ARC) concept aimed to define the next generation of waste energy recuperation with a cost optimized WHR system. ARC project used engine coolant as the working fluid. This approach reduced the need for a secondary working fluid circuit and subsequent complexity. A portion of the liquid phase engine coolant has been pressurized through a set of working fluid pumps and used to recover waste heat from the exhaust gas recirculation (EGR) and exhaust tail pipe exhaust energy. While absorbing heat, the mixture is partially vaporized but remains a wet binary mixture. The pressurized mixed-phase engine coolant mixture is then expanded through a fixed-volume ratio expander that is compatible with two-phase conditions. Heat rejection is accomplished through the engine radiator, avoiding the need for a separate condenser. The ARC system has been investigated for PACCAR’s MX-13 HD diesel engine.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cryogenic Considerations for Superconducting Magnet System Design for the Material Plasma Exposure eXperiment (MPEX)

The Material Plasma Exposure eXperiment (MPEX) has been proposed as a facility to address plasma material interaction knowledge gaps to qualify and develop materials and technologies that surround plasma environments for future fusion reactors. Utilizing different radio-frequency (rf) heating technologies, MPEX is a linear plasma device that will generate fusion reactor–like plasmas with energies and particle fluxes at the target materials with electron temperatures of 1 to 15 eV, electron densities of 10 20 to 10 21 m -3 , and ion fluxes greater than 10 24 m -2 s -1 . Starting with the MPEX requirements with respect to magnetic fields between 0.1 and 2.5 T and warm bores of either 0.65 m or 1.56 m, conceptual designs for a superconducting magnet system have been developed that utilize multiple NbTi windings distributed across seven cryostats to accommodate rf heating, water cooling, and vacuum systems needed for MPEX. While the cryogenic and magnet technologies relative to the field and space requirements are mature, the integration of these technologies across multiple cryostats presents several technical and logistical challenges. An analysis of the preferred refrigeration approach, modular recondensing liquid helium cryocoolers, was performed. Utilizing a design margin of a factor of two, this approach is feasible within the current design requirements for MPEX with some considerations related to its implementation within the thermal shields and the magnet subsystem geometries.

Duckworth, Robert↗

A Visual Technique for Determining Qualitative Aerodynamic Heating Rates on Complex Configurations

An experimental investigation was conducted at a test-section Mach number of 4.95 and a stagnation temperature of 400 F to evaluate a visual technique for obtaining qualitative aerodynamic heat-transfer data on complex configurations.This technique utilized a temperature-sensetive paint indicated that this technique was satisfactory for determining qualitative heat-transfer rates on various bodies, some of which exhibited complex flow patterns. The results obtained have been found useful to guide the instrumentation of quantitative heat-transfer models, to supplement quantitative heat-transfer measurements, and to make preliminary heat-transfer studies for new configurations.

P. Calvin Stainback↗