Concrete compressive strain behavior and magnitudes under uniaxial fatigue loading
Not provided.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not provided.
High-energy-density (HED) hydrodynamics studies such as those relevant to inertial confinement fusion and astrophysics require highly disparate densities, temperatures, viscosities, and other diffusion parameters over relatively short spatial scales. This presents a challenge for high-order accurate methods to effectively resolve the hydrodynamics at these scales, particularly in the presence of highly disparate diffusion. A significant volume of engineering and physics applications use an unstructured discontinuous Galerkin (DG) method developed based on the finite element mesh generation and algorithmic framework. This work discusses the application of an affine reconstructed nodal DG method for unstructured grids of triangles. Solving the diffusion terms in the DG method is non-trivial due to the solution representations being piecewise continuous. Hence, the diffusive flux is not defined on the interface of elements. The proposed numerical approach reconstructs a smooth solution in a parallelogram that is enclosed by the quadrilateral formed by two adjacent triangle elements. The interface between these two triangles is the diagonal of the enclosed parallelogram. Similar to triangles, the mapping of parallelograms from a physical domain to a reference domain is an affine mapping, which is necessary for an accurate and efficient implementation of the numerical algorithm. Thus, all computations can still be performed on the reference domain, which promotes efficiency in computation and storage. This reconstruction does not make assumptions on choice of polynomial basis. Reconstructed DG algorithms have previously been developed for modal implementations of the convection–diffusion equations. However, to the best of the authors’ knowledge, this is the first practical guideline that has been proposed for applying the reconstructed algorithm on a nodal discontinuous Galerkin method with a focus on accuracy and efficiency. As a result, the algorithm is demonstrated on a number of benchmark cases as well as a challenging substantive problem in HED hydrodynamics with highly disparate diffusion parameters.
Here, we present EZ, a novel current deposition algorithm for particle-in-cell (PIC) simulations. EZ calculates the current density on the electromagnetic grid due to macro-particle motion within a time step by solving the continuity equation of electrodynamics. Being a charge conserving hybridization of Esirkepov's method and ZigZag, we refer to it as “EZ” as shorthand for “Esirkepov meets ZigZag”. Simulations of a warm, relativistic plasma with PIConGPU show that EZ achieves the same level of charge conservation as the commonly used method by Esirkepov, yet reaches higher performance for macro-particle assignment-functions up to third-order. In addition to a detailed description of the functioning of EZ, reasons for the expected and observed performance increase are given, and guidelines for its implementation aiming at highest performance on GPUs are provided.
Characterizing the functional properties of plant acyl-ACP thioesterases (TEs), a key enzyme class used in the production of renewable oleochemicals in microbial hosts, experimentally, can be an expensive and time consuming process since it requires manual screening of thousands of candidates in a database. Using amino acid sequence to computationally predict an enzyme’s function might accelerate this process; however obtaining the necessary amount of information on previously characterized enzymes and their respective sequences required by standard Machine Learning (ML) based approaches to accurately infer sequence-function relationships can be prohibitive, especially with a low-throughput testing cycle. Experimental noise, unbalanced dataset where high sequence similarity does not always imply identical functional properties will further prevent robust prediction performance. Herein we present a ML method, Ensemble method for enZyme Classification (EnZymClass), that is specifically designed to address these issues. We used EnZymClass to classify TEs into short, long and mixed free fatty acid substrate specificity categories. While general guidelines for inferring substrate specificity have been proposed before, prediction of chain-length preference from primary sequence has remained elusive for plant acyl-ACP TEs. By applying EnZymClass to a subset of TEs in the ThYme database, we identified two medium chain TEs, ClFatB3 and CwFatB2, with previously uncharacterized activity in E. coli fatty acid production hosts.
Organic matter (OM)-hosted pores are important constituents of the pore system of black shales and play a crucial role in determining their methane adsorption capacity and porosity. OM-hosted pores are generally observed and described with scanning electron microscope (SEM) on Ar ion-milled surfaces. However, SEM imaging is not able to reliably distinguish OM types and relate the observed pores to specific macerals. Partly because of this inability to relate organic pores to macerals, the evolution of organic porosity during thermal maturation remains poorly understood. In this paper, we review the petrographic characteristics of dispersed organic matter (DOM) in black shales under the SEM. Organic petrographic classification of DOM developed for reflected-light microscopy is so far the most practical method when describing DOM in black shales under the SEM because this classification has information on the origin of DOM. Therefore, correlative microscopy (combination of reflected-light and electron microscopy) is the most effective method to identify both OM types and OM-hosted pores. This method, however, is not readily available to most researchers. Although identifying OM on the basis of SEM observations is a challenging task, it is achievable provided there is a good understanding of the studied shales, especially their thermal maturity and original OM composition. Therefore, the overall objective of this paper is to review petrographic characteristics of DOM in black shales under the SEM to provide some guidelines for identifying DOM from SEM observations. We also review factors that control the formation and preservation of OM-hosted pores. OM-hosted pores consist of primary and secondary organic pores. Primary organic pores are pores inherited from the biological structure of the original OM. Secondary organic pores develop during hydrocarbon generation and expulsion from oil-prone OM and are hosted by solid bitumen or pyrobitumen. The development of secondary organic pores is controlled by thermal maturity and OM type, and their preservation is subject to thermal maturity, OM content, and mineralogical composition. The presented view of the evolution of micropore and mesopore characteristics of OM with thermal maturity is based on data from the literature. The specific surface area and pore volume of OM in black shales follow a parabolic pattern with increasing thermal maturity (quantified via vitrinite reflectance, R o ). The initial increase reflects development of OM-hosted pores, and the subsequent decrease is due to denser stacking of aromatic units in the macromolecular structure of OM, with maximum values (specific surface area ~ 300 m 2 /g and pore volume ~ 0.3 cm 3 /g) reached at R o values in the 2.5-3.5% range. The contribution of OM-hosted pores to the pore characteristics of black shales depends on OM content, OM type, and thermal maturity.
Groundwater may contain radioactive substances which can be dangerous to human health. Concentrations of natural radionuclides polonium (Po), thorium (Th), uranium (U), and radium (Ra) isotopes were measured in groundwater samples collected from different locations in the vicinity of the Waste Isolation Pilot Plant (WIPP) site in Carlsbad, New Mexico. The average values of gross activity concentrations of 210 Po, 228 Th, 238 U, 234 U, 226 Ra and 228 Ra isotopes were determined to be 1.62 Bq L -1 in shallow groundwater and 5.88 Bq L -1 in deep groundwater, respectively. The total radioactivity in deep groundwater was higher than that in shallow groundwater, and most of the radioactivity in the water is from 226 Ra. Furthermore, the effective doses for ingestion of natural radionuclides were about 0.333 mSv y–1 for shallow groundwater and about 1.338 mSv y –1 for deep groundwater samples, which are higher than the World Health Organization (WHO, 2017) guideline level (0.1 mSv y –1 ) for drinking water. Ra dominated the total ingestion dose, contributing 93.06 % and 75.40 % of the total effective doses to the deep and shallow groundwater, respectively. The ingrowth and decay of natural radionuclides suggested that 228 Ra/ 226 Ra ratio can be a useful indicator of the source of radioactive contamination. The radioactivity data obtained from the investigated groundwater samples can be used to establish a baseline for radioactivity levels in groundwater around the WIPP site.
Here this paper examines the MARKAL-NETL modeling results for the Energy Modeling Forum Study on Deep Decarbonization & High Electrification Scenarios for North America (EMF 37) with specific focus on carbon dioxide removal (CDR) technologies and opportunities under different scenarios guidelines, policies, and technological advancements. The results demonstrate that CDR, such as, bioenergy with carbon capture and storage (BECCS), direct air capture (DAC) and afforestation are key negative emission technologies in deep decarbonization scenarios in the U.S. are accounted for about 70% of annually avoided carbon dioxide emissions (CO 2 ) by 2050, or more than 2 billion tons of CO 2 (GtCO 2 ). The potential scale of CDR and its impact on the energy system depends on energy supply and demand technologies advancement and their costs, the level of end-use sectors electrification, availability and costs of CDR. Results show that the carbon prices are substantially lower if the advanced technologies available, particularly, in carbon management scenarios.
With climate change, the indoor built environment is expected to significantly influence the occupant's safety and well-being. A novel multi-criteria thermal resilience certification scheme for indoor built environments during extreme heat events is proposed in this paper. The certification scheme considers overheating, thermal comfort, heat stress, and hygrothermal discomfort in built environments. These criteria are quantified using key performance indicators like indoor overheating degree, hours of exceedance, wet-bulb globe temperature, and heat index, respectively. This scheme is developed based on existing best practices like standards, rating systems, and literature. The scheme is implemented on a benchmark building energy performance model for detached post-World War II dwellings in Belgium as a case study using weather data measured from the City of Brussels. The indoor overheating in the reference dwelling is assessed with a static threshold of 27 °C for the bedrooms and adaptive thresholds for other areas. The analysis found that the building performance is within the defined threshold levels throughout the heat wave duration for all criteria. Therefore, the reference dwelling got a maximum attainable score of four points and is rated five-star for thermal resilience during heat waves. The proposed certification scheme is intended as a standardized framework and highlights the need for further revisions in building performance policies and guidelines.
Buildings in the United States account for nearly half of total U.S. energy use. The energy used for space conditioning can be reduced by utilizing thermal energy storage, such as phase change materials (PCMs), into building envelopes; however, the energy savings of PCM-integrated building envelopes reported in the literature vary widely. In the absence of established guidelines, thermophysical requirements of an optimal PCM, its method of application into the building envelope, and the corresponding energy savings under various climates remain unknown. Here, we perform an extensive numerical investigation on the integration of PCM into building walls to establish the key conditions required for effective utilization of PCM in reducing heat gains in the cooling season and heat losses in the heating season. We also determine the optimal transition temperature, optimal PCM location in the wall, and the energy-saving potential of the PCM-integrated building walls in five U.S. cities located in different International Energy Conservation Code climate zones. Results show that employing PCMs in building walls does not always lead to an improvement; in fact, incorrect applications of PCMs can substantially increase energy use in the buildings. In the climates we studied, PCMs were found effective in reducing heat gains during the cooling season while mostly ineffective in managing heat losses during heating season. Depending on the climate, optimized PCMs in U.S. building walls can provide reduction in the annual heat gain in the range of 3.5% to 47.2% and the annual heat loss in the range of -2.8% to 8.3%. Future consideration of buildings with substantial solar gains in winter may lead to more reduction in heat losses by PCMs.
The goal of this investigation was to evaluate potential energy impacts of circadian lighting design recommendations gaining attention in a variety of common applications such as offices and classrooms. The renewed focus on health along with advances in SSL technology capabilities has underscored that there is still much to learn regarding the relationship between light and human physiology. The energy implications of designing to address these possible physiological effects are not yet fully understood. Beyond the fact that the basic metric of luminous efficacy (lumens per watt) does not cover these other effects, the emerging science seems to indicate that addressing a holistic view of the human needs in most applications may mean a need for increased light and associated energy use by electric lighting systems. Within the two applications considered, lumen output, spectral characteristics, surface reflectance distribution and desk orientation were varied to explore the magnitude of potential effects. Meeting current IES illuminance recommendations did not satisfy existing EML and CS recommendations for any of the simulations. In some cases, satisfying circadian metric recommendations required average illuminance that was more than double IES recommendations, which may negatively impact lighting quality as well. Using results from 45 unique simulation conditions, it was estimated that lighting energy use may increase between 10% and 100% due to increased luminaire light levels used to meet circadian lighting design recommendations listed in current building standards such as WELL v2 Q2 2019, UL Design Guideline 24480, and CHPS Core Criteria 3.0.
Personal thermal management systems (PTMS) are highly desirable for improving individual thermal comfort and reducing indoor HVAC energy consumption. Although there have been many attempts in developing PTMS, existing PTMS are generally bulky, heavy or immobile. Besides, previous analysis on additional personal cooling and heating power required for maintaining thermal comfort in changing environments did not consider the individual difference in metabolism and the variability of comfort skin temperature with environmental conditions. In this paper, we report on the development of a novel lightweight (<1 kg) thermoelectric air conditioning undergarment system with a preferred design of branching tubing network (branching angle of 60° and diameter ratio of 0.782) for air distribution. Through thermal manikin and human subject tests, we demonstrated that the novel system is capable of providing a maximum of 15.5 W of personal cooling and 18.1 W personal heating with a coefficient of performance (COP) greater than 0.4, which is sufficient to the expansion of the indoor set-points by at least 2.2 °C (4 °F) on both sides without compromising thermal comfort and the potential saving of about 15% HVAC energy. Furthermore, our study improved the understanding of the required additional personal cooling and heating power for changing environmental conditions, which are essential guidelines for the further development of PTMS.
Heating, ventilation, and air-conditioning (HVAC) systems in commercial buildings have proven to be a great asset for providing secondary frequency regulation (FR) service to the power grid. However, how the provision of FR service affects the HVAC system Quality of Service (QOS) is still largely unknown. In particular, there exists a controversy regarding the energy efficiency impact. This paper investigates how a HVAC system performance and its associated controls are impacted during and after the FR service. For the assessment, we developed a dynamic Modelica-based medium office building model as a virtual testbed with the Air Handling Unit (AHU) fans providing the FR service. Different regulation capacities (demand levels) and standard test signals under various load profiles in the U.S. are considered. The results show that FR has little or no impact on the HVAC operation and occupant thermal comfort while the building is providing the service if an appropriate regulation capacity is pre-determined. However, if the regulation capacity is overestimated, the quality of the FR service provided by the HVAC system and the HVAC energy efficiency will be affected due to the equipment operating constraints. In addition, the AHU supply air temperature fluctuates, and the controller cannot maintain the desired setpoint as the FR magnitude is increased. After the FR service time, the system takes a certain period to return to normal operation. The recovery period extends with the increase in the FR magnitude. For this case study, there exists a control conflict between the FR control and the existing HVAC control (from ASHRAE Guideline 36-2018) during high load conditions, causing the fan speed to saturate. The fan power consumption could increase significantly; up to 77% increase compared to the baseline was observed. This case study demonstrates that the HVAC system controls need to be enhanced and adapted to minimize the interaction between the FR controller and the indoor environmental controls in order to preserve the HVAC system QOS while (during and after) providing satisfactory FR service.
“Stay-at-home” orders and other health precautions enacted during the COVID-19 pandemic have led to substantial changes in residential electricity usage. Here, we conduct a case study to analyze data from 390 apartments in New York City (NYC) to examine the impacts of two key drivers of residential electricity usage: COVID-19 case-loads and the outdoor temperature. We develop a series of regression models to predict two characteristics of residential electricity usage on weekdays: The average occupied apartment’s consumption (kWh) over a 9am-5pm window and the hourly peak demand (Watt) over a 12pm-5pm window. Via a Monte Carlo simulation, we forecast the two usage characteristics under a possible scenario in which stay-at-home orders in NYC, or a similar metropolitan region, coincide with warm summer weather. Under the scenario, the 9am-5pm residential electricity usage on weekdays is predicted to be 15% – 24% higher than under prior, pre-pandemic conditions. This could lead to substantially higher utility costs for residents. Additionally, we predict that the residential hourly peak demand between 12pm and 5pm on weekdays could be 35% – 53% higher than that under pre-pandemic conditions. We conclude that the projected increase in peak demand - which might arise if stay-at-home guidelines coincided with hot weather conditions - could pose grid management challenges, especially for residential feeders. We also note that, if there is a longer lasting shift towards work and study-from-home, utilities will have to rethink load profile considerations. The applications of our predictive models to managing future smart-grid technology are also highlighted.
Data centers are energy-intensive facilities with substantial low-grade waste heat. High-temperature heat pumps can be critical in boosting the data center’s waste heat for district heating, improving the system-level energy efficiency of data centers, and reducing CO 2 emissions in district heating. This study built thermodynamic models to assess high-temperature heat pumps with six configurations using low global warming potential refrigerants to supply heat up to 120 °C. The heat pump configurations include single-stage or two-stage cycles with advanced components, such as internal heat exchanger, economizer, flash tank, or parallel compressor. The refrigerants include R1234ze(Z), R1233ed(E), R1224yd(Z), R600, and R600a, and R245fa is used as a reference. A case study was carried out to recover the waste heat from the Frontier high-performance computing data center and provide hot water for district heating at the US Department of Energy’s Oak Ridge National Laboratory campus. The optimized performance of high-temperature heat pumps is characterized with various effectiveness of internal heat exchangers, and the operating parameters of economizer or flash tank, as well as their combination. The results show that the configurations of two-stage cycles with internal heat exchanger + flash tank and internal heat exchanger + economizer/parallel-compressor provide the highest coefficient of performance under scenarios of the maximum allowable value and a fixed value (0.3) of the internal heat exchangers’ effectiveness, respectively. R1234ze(Z) and R600a are the most promising refrigerants, considering trade-offs between the coefficient of performance and the volumetric heating capacity. The single-stage cycle with internal heat exchanger + economizer/parallel-compressor using R1234ze(Z) is recommended for utilizing Fronter’s waste heat in district heating. A one mega-watt high-temperature heat pump will reduce 33,100–33,200 metric tons of CO2 emission annually, corresponding to 85.4 %–85.6 % of equivalent CO2 emissions from natural gas boilers. Here, this study provides good guidelines for designing and deploying high-temperature heat pumps to support sustainable data centers and decarbonize district heating in the US.
Recent advances in physics-informed and data-driven machine learning promise improved thermal models for advanced building control, yet there is limited quantitative evidence on when added physics structure and architectural complexity are beneficial. Here, this work presents a systematic benchmark of five representative system identification methods for modeling multi-zone building thermal dynamics: linear state-space models, multi-layer perceptrons, neural state-space models, neural ordinary differential equations, and physically-consistent neural networks. The methods are evaluated across multiple data regimes and zone coupling strategies. Using a high-fidelity multi-zone commercial building emulator, we examine short-term and long-term prediction accuracy, computational efficiency, and ease of development. Our results reveal critical trade-offs between prediction performance, model complexity, and physical consistency. We demonstrate that decoupled, nonlinear black-box models consistently outperform coupled physics-constrained architectures in both predictive accuracy and out-of-distribution robustness in majority of the test cases for the building type considered in the study. Our findings quantify the cost of complexity in building thermal modeling and provide concrete, actionable, scenario-based guidelines for selecting model classes for control-oriented applications.
Effective harvesting of power from high speed highly transient inflows such as the outflow of rotating detonation combustors (RDCs) is key to achieving their promised cycle efficiency step jump. To increase power density and efficiency simultaneously, a concept that can directly ingest transonic outflow, addressing the choking is needed, i.e. without additional transition elements. A new statorless design was assessed using a comprehensive approach to quantify all contributions to loss generation in transient flows, locally and globally. The turbine rotor was designed under steady flow conditions with a genetic algorithm. The comparison of power and loss generation between steady and unsteady flow results shows that a design methodology under steady-state conditions is suitable to characterize the performance of different designs. Three design families were further assessed under highly transient transonic conditions including traveling shock waves with a relative total pressure amplitude of 149.6% around the mean value and inflow angle variations from -26.5 deg to +51.8 deg. The oblique shock impinging on the pressure side (PS) of the turbine augments the shaft power extraction. When the oblique shock reflects between the pressure side and suction side (SS), its strength diminishes. This paper provides design guidelines on efficient turbine work extraction from the shocks emanating from detonation combustors.
Data centres produce waste heat, which can be utilized in district heating systems. However, the mismatch between data centres’ heat supply and district heating systems’ heat demands limits its utilization. Further, high peak loads increase the operation cost of district heating systems. This study aimed to solve these problems by introducing thermal energy storages. A water tank and a borehole thermal energy storage system were selected as the short-term and long-term thermal energy storage, respectively. Energy, economic, and environmental indicators were introduced to evaluate different solutions. The case study was a campus district heating system in Norway. Results showed that the water tank could shave the peak load by 31% and save the annual energy cost by 5%. The payback period was lower than 15 years when the storage efficiency remained higher than 80%. However, it had no obvious benefits in terms of mismatch relieving and CO emissions reduction. In contrast, the borehole thermal energy storage increased the waste heat utilization rate to 96% and reduced the annual CO emissions by 8%. However, the payback period was more than 17 years. These results provide guidelines for the retrofit of district heating systems, where data centres’ waste heat is available.