Analytical and experimental studies of graphite-epoxy and boron-epoxy angle ply laminates in shear

The results of a comparison study between a test program on the inelastic response under inplane shear over a wide range of graphite-epoxy and boron-epoxy angle-ply laminates are reported. This investigation was aimed at evaluating the applicability and adequacy of these analyses to predict satisfactorily the responses of angle-ply laminates. It was observed that these analytical tools are inadequate for this purpose as they fail to predict with sufficient confidence the shape of response and in particular the strength values associated with a given laminate configuration. Consequently, they do not provide the sought-after information about failure mechanisms which trigger failure of a particular designed laminate.

Weller, T.↗

Experimental studies of graphite-epoxy and boron-epoxy angle ply laminates in compression

A test program aimed at studying the nonlinear/inelastic response under axial compression across a wide range of angle ply was graphite-epoxy and boron-epoxy laminates was presented and described. The strength allowables corresponding to the various laminate configurations were defined and the failure mechanisms which dictate their mode of failure were detected. The program involved two types of specimens for each laminate configuration: compression sandwich coupons and compression tubes. The test results indicate that the coupons perform better than the tubes displaying considerably high stress-strain allowables and mechanical properties relative to the tubes. Also, it is observed that depending on their dimensions the coupons are susceptible to very pronounced edge effects. This sensitivity results in assigning to the laminate conservative mechanical properties rather than the actual ones.

Weller, T.↗

Analytical and experimental studies of graphite-epoxy and boron-epoxy angle ply laminates in compression

The applicability and adequacy of several computer techniques in predicting satisfactorily the nonlinear/inelastic response of angle ply laminates were evaluated. The analytical predictions were correlated with the results of a test program on the inelastic response under axial compression of a large variety of graphite-epoxy and boron-epoxy angle ply laminates. These comparison studies indicate that neither of the abovementioned analyses can satisfactorily predict either the mode of response or the ultimate stress value corresponding to a particular angle ply laminate configuration. Consequently, also the simple failure mechanisms assumed in the analytical models were not verified.

Weller, T.↗

Method of adhering bone to a rigid substrate using a graphite fiber reinforced bone cement

A method is described for adhering bone to the surface of a rigid substrate such as a metal or resin prosthesis using an improved surgical bone cement. The bone cement has mechanical properties more nearly matched to those of animal bone and thermal curing characteristics which result in less traumatization of body tissues and comprises a dispersion of short high modulus graphite fibers within a bonder composition including polymer dissolved in reactive monomer such as polymethylmethacrylate dissolved in methylmethacrylate monomer.

Knoell, A. C.↗

Toughening of graphite-epoxy composites by interlaminar perforated Mylar films

Fracture and notch strength tests of graphite-epoxy composites showed that unidirectional lay-ups generally exhibit longitudinal cracking before failure, whereas multidirectional lay-ups fail transversely with little longitudinal cracking. A simple qualitative analysis suggested that the higher matrix shear stresses in unidirectional materials cause the longitudinal cracking, and that this cracking was responsible for the high toughness of unidirectional composites. In a series of comparative tests, the interlaminar strength of multi-directional composites was reduced by placing perforated Mylar films between laminae; tests on notched and slotted specimens showed that the interlaminar films promoted delamination and longitudinal cracking near the notches and that, as a result, toughness, notch strength, and impact strength were substantially increased.

Elber, W.↗

Process for utilizing low-cost graphite substrates for polycrystalline solar cells

Low cost polycrystalline silicon solar cells supported on substrates were prepared by depositing successive layers of polycrystalline silicon containing appropriate dopants over supporting substrates of a member selected from the group consisting of metallurgical grade polycrystalline silicon, graphite and steel coated with a diffusion barrier of silica, borosilicate, phosphosilicate, or mixtures thereof such that p-n junction devices were formed which effectively convert solar energy to electrical energy. To improve the conversion efficiency of the polycrystalline silicon solar cells, the crystallite size in the silicon was substantially increased by melting and solidifying a base layer of polycrystalline silicon before depositing the layers which form the p-n junction.

Chu, T. L.↗

Some effects of composition on friction and wear of graphite-fiber-reinforced polyimide liners in plain spherical bearings

Oscillating, plain spherical bearings with graphite-fiber-reinforced polyimide (GFRPI) liners were tested for friction and wear from 25 to 315 C. A condensation polymer was compared with an addition polymer, and a high-modulus fiber was compared with a lower cost, low-modulus fiber. All polymer-fiber combinations gave friction coefficients from 0.05 to 0.18 and low wear. Adding CdO and CdI2 reduced the wear of degassed bearings in dry air. These additives were not needed when the bearing liners contained adsorbed moisture. Although, at 25 C, MoS2 reduced the friction and wear of the base composite at unit loads above 70,000,000 N/m squared (10,000 psi), it had no beneficial effect at lighter loads.

Sliney, H. E.↗

Some load limits and self-lubricating properties of plain spherical bearings with molded graphite fiber reinforced polyimide liners to 320 C

Plain spherical bearings with molded liners of self-lubricating graphite fiber-polyimide composite were developed and their dynamic load capacities were determined. Liners were prepared by transfer molding a prepolymer resin-fiber mix into the space between the ball and outer race, the completing polymerization under heat and pressure. Bearing dynamic load capacities were in excess of 140 MPa (20,000 psi) from room temperature to 260 C and about 70 MPa (10,000 psi) at 320 C. Friction coefficients were about 0.20 at room temperatures and light loads and tended to decrease with increasing temperatures and loads to about 0.15. Thermal expansion of the liner at uniform bearing temperatures of 200 C or higher produced a bearing preload which could be alleviated by providing an initial internal diametral clearance of 0.05 to 0.10 mm.

Sliney, H. E.↗

The correlation of ultrasonic attenuation and shear strength in graphite-polyimide composites

The buffer rod technique for measuring attenuation in thin specimens is modified here to apply to specimens having intermediate thicknesses and high attenuation. The described procedure, which requires only one accessible surface of the material, was used to determine the initial attenuation values of ultrasonic waves in short beam shear specimens of graphite-polyimide composite material. It is shown that there is good correlation between the initial attenuation values and the shear strengths of the specimens determined by the standard short beam shear test method. The modified ultrasonic buffer block technique offers much potential for service as a quantitative, nondestructive, quality assurance test for composite materials.

Hayford, D. T.↗

NDT of DC-10 graphite-epoxy rudder

The results of visual and ultrasonic nondestructive tests (NDT) on a DC-10 rudder constructed of Thornel 300/5208 graphite-epoxy are presented. A viscous couplant was used for both contact pulse-echo ultrasonics and the Fokker bondtester. Attention is given to the stiffness of cohesive bond structures (the rudder is assembled primarily in a basic six-ply pattern), and to possible delamination. A piezoelectric transducer is employed to sense changes in impedance and signal amplitude. In all, four rudder units were evaluated. The main problems found in the units were porosity and cracking. It is noted that rudder unit four was able to be sufficiently cured to permit static tests on all rib, spar, and skin panel interfaces.

Hagemaier, D. J.↗

Reproducibility of structural strength and stiffness for graphite-epoxy aircraft spoilers

Structural strength reproducibility of graphite epoxy composite spoilers for the Boeing 737 aircraft was evaluated by statically loading fifteen spoilers to failure at conditions simulating aerodynamic loads. Spoiler strength and stiffness data were statistically modeled using a two parameter Weibull distribution function. Shape parameter values calculated for the composite spoiler strength and stiffness were within the range of corresponding shape parameter values calculated for material property data of composite laminates. This agreement showed that reproducibility of full scale component structural properties was within the reproducibility range of data from material property tests.

Howell, W. E.↗

Epoxy graphite cell cases

The graphite epoxy cell case and header developed as a means of weight reduction are discussed. Aspects considered include gas permeability, KOH compatibility, pressure and structural dynamic integrity, fiber orientation, fabrication process, cover-to-case sealing, terminal installation and sealing, reproducibility, exposure to the extractable materials that might influence the electrochemical portion of the cell, and electrical conductivity between the terminals.

Bogner, S.↗

Effects of moisture on torsion and flexure properties of graphite-epoxy composites

The effects of moisture and temperature on unidirectional and multi-ply laminates of T300/934 and AS/3501 graphite-epoxy systems were investigated. Properties studied were static flexure strength, and flexure and torsion fatigue strengths at room temperature and at 74 C. Specimens with increased moisture content showed a reduced static flexure strength; water as the test environment had only a negligible influence. In flexure fatigue and torsion fatigue, the water environment caused somewhat reduced fatigue strengths at room temperature and significantly greater degradation in 74 C water. The failure mode in all cases was interlaminar delamination.

Sumsion, H. T.↗

Lubricating and wear mechanisms for a hemisphere sliding on polyimide-bonded graphite fluoride film

Friction, wear life, rider wear, and film wear for a 440 C high-temperature-stainless-steel, hemispherically tipped rider sliding against polyimide-bonded graphite fluoride films were evaluated in a moist-air atmosphere at 25 C. Optical microscope and surface profilometry observations were made at various sliding intervals to determine how film thickness affected the lubricating and failure mechanisms of the films. Two lubrication regimes operated for the same load. In the first, the film supported the load and the lubricating mechanism consisted of the shear (plastic flow) of a thin layer of the lubricant between the metallic rider and the film surface. In the second, the film did not support the load (it was worn away) and the lubricating mechanism consisted of the shear of very thin lubricant films between flat areas generated on the rider and on sandblasted metallic asperities in the film wear track. Lubricant was supplied from the valleys between the asperities or from the sides of the wear track. With thicker films, wear life increased since a greater lubricant supply was available from the sides of the wear track.

Fusaro, R. L.↗

Comparative evaluation of woven graphite-epoxy composites

A comparative evaluation of some of the mechanical properties of woven graphite-epoxy composites are discussed. In particular, the types of weaves and the resin contents were chosen for comparison. The types of weaves selected are plain weave, satin weave, and tridirectional weave. The composites made of the fabrics are compared to composites made from unidirectional tapes under static and fatigue loading. During static loading, acoustic emission events were monitored. Also, examinations of fracture surfaces and polished sections both away from the fracture surface, and of virgin specimens under an electron microscope are discussed.

Hanagud, S.↗

A study of the deposition of carbide coatings on graphite fibers

The chemical vapor deposition of boron carbide and silicon carbide on graphite fibers to increase their electrical resistance was studied. Silicon carbide coatings were applied without degradation of the mechanical properties of the filaments. These coatings typically added 1000 ohms to the resistance of a filament as measured between two mercury pools. When SiC-coated filaments were oxidized by refluxing in boiling phosphoric acid, average resistance increased by an additional 1000 ohms; in addition resistance increases as high as 150 K ohms and breakdown voltages as high as 17 volts were noted. Data on boron carbide coatings indicated that such coatings would not be effective in increasing resistance, and would degrade the mechanical properties.

Suplinskas, R. J.↗

The OSO-8 mosaic graphite stellar X-ray polarimeter

The OSO 8 satellite, launched on June 21, 1975, contains two X-ray polarimeters. These polarimeters use mosaic crystals of graphite to yield polarization-sensitive Bragg reflection of stellar X-rays. The crystals reflect a narrow energy bandwidth centered at 2.6 and 5.2 keV. The polarimeter background signal is minimized by mounting the crystals on parabolic surfaces which focus the diffracted X-rays onto small-area beryllium-window proportional counters. This technique permits the observation of low-intensity X-ray sources and reduces the possibility of systematic background effects which could lead to a false signature of polarization. A description of the instrument is given, and preliminary results for the Crab Nebula and Cyg X-1 are presented.