Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “field ionization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

Improved Chemistry and Attenuation Models for Communication Blackout Simulation During Mars 2020 Entry

As a blunt body enters a planetary atmosphere, a plasma forms in the hypersonic shock layer and attenuates radio communication causing signal blackout for some duration of the entry sequence. In our previous work,1 computational fluid dynamics (CFD) was applied to model the entry flow around the Mars 2020 spacecraft, including ionization and electron density throughout the flow field, and predict ultra-high frequency (UHF) radio wave attenuation due to electrons. In total, 17 chemical species and their spatial profiles are modelled around the Mars 2020 spacecraft at 11 different points in time during entry. Although the simulation predicted the onset of attenuation well, the timing of the end of the predicted blackout window significantly preceded the end time observed during the 2021 landing. The present work seeks to improve the attenuation model by accounting for the fact that electrons undergo collisions with heavier species in the flow, which is an effect that was neglected in previous analyses. It is determined that including electron collisions increases the overall magnitude of attenuation predicted especially towards the end of the measured attenuation period, improving qualitative agreement between predicted and measured attenuation to both spacecraft receiving the signal from Mars 2020. To explore the remaining uncertainty in signal attenuation predictions further, a sensitivity study is performed to investigate the impact of associative ionization and electron-impact ionization rate coefficients on the electron density predicted by CFD and on the resulting attenuation predictions. These coefficients are believed to contain up to order-of-magnitude uncertainty, and therefore may significantly affect the number density of electrons throughout the flow field. Variations in associative ionization coefficients demonstrate significant impact on the magnitude of attenuation due to variation in the electron density coming from associative ionization. However, the start and end times of the predicted signal attenuation period are only slightly impacted by said variation.

Eve Papajak↗

Improved Chemistry and Attenuation Models for Communication Blackout Simulation During Mars 2020 Entry

As a blunt body enters a planetary atmosphere, a plasma forms in the hypersonic shock layer and attenuates radio communication causing signal blackout for some duration of the entry sequence. In our previous work,1 computational fluid dynamics (CFD) was applied to model the entry flow around the Mars 2020 spacecraft, including ionization and electron density throughout the flow field, and predict ultra-high frequency (UHF) radio wave attenuation due to electrons. In total, 17 chemical species and their spatial profiles are modelled around the Mars 2020 spacecraft at 11 different points in time during entry. Although the simulation predicted the onset of attenuation well, the timing of the end of the predicted blackout window significantly preceded the end time observed during the 2021 landing. The present work seeks to improve the attenuation model by accounting for the fact that electrons undergo collisions with heavier species in the flow, which is an effect that was neglected in previous analyses. It is determined that including electron collisions increases the overall magnitude of attenuation predicted especially towards the end of the measured attenuation period, improving qualitative agreement between predicted and measured attenuation to both spacecraft receiving the signal from Mars 2020. To explore the remaining uncertainty in signal attenuation predictions further, a sensitivity study is performed to investigate the impact of associative ionization and electron-impact ionization rate coefficients on the electron density predicted by CFD and on the resulting attenuation predictions. These coefficients are believed to contain up to order-of-magnitude uncertainty, and therefore may significantly affect the number density of electrons throughout the flow field. Variations in associative ionization coefficients demonstrate significant impact on the magnitude of attenuation due to variation in the electron density coming from associative ionization. However, the start and end times of the predicted signal attenuation period are only slightly impacted by said variation.

Eve Papajak↗

Reduced Model for Direct Induction Startup Scenario Development on MAST-U and NSTX-U

A reduced semi-empirical model using time-dependent axisymmetric vacuum field calculations is used to develop the prefill and feed-forward coil current targets required for reliable direct induction (DI) startup on the new MA-class spherical tokamaks, MAST-U and NSTX-U. The calculations are constrained by operational limits unique to each device, such as the geometry of the conductive elements and active coils, power supply specifications and coil heating and stress limits. The calculations are also constrained by semi-empirical models for sufficient breakdown, current drive, equilibrium and stability of the plasma developed from a shared database. A large database of DI startup on NSTX and NSTX-U is leveraged to quantify the requirements for achieving a reliable breakdown (Ip ~ 20 kA). It is observed that without pre-ionization, STs access the large E/P regime at modest loop voltage (Vloop) where the electrons in the weakly ionized plasma are continually accelerating along the open field lines. This ensures a rapid (order millisecond) breakdown of the neutral gas, even without pre-ionization or high-quality field nulls. The timescale of the initial increase in Ip on NSTX is reproduced in the reduced model provided a mechanism for impeding the applied electric field is included. Most discharges that fail in the startup phase are due to an inconsistency in the evolution of the plasma current (Ip) and equilibrium field or loss of vertical stability during the burn-through phase. The requirements for the self-consistent evolution of the fields in the weakly and full-ionized plasma states are derived from demonstrated DI startup on NSTX, NSTX-U and MAST. The predictive calculations completed for MAST-U and NSTX-U illustrate that the maximum Ip ramp rate (dIp/dt) in the early startup phase is limited by the voltage limits on the poloidal field coils on MAST-U and passive vertical stability on NSTX-U.

Direct induction↗

PRECURSORS OF SHORT GAMMA-RAY BURSTS

We carried out a systematic search of precursors on the sample of short gamma-ray bursts (GRBs) observed by Swift. We found that {approx}8%-10% of short GRBs display such early episodes of emission. One burst (GRB 090510) shows two precursor events, the former {approx}13 s and the latter {approx}0.5 s before the GRB. We did not find any substantial difference between the precursor and the main GRB emission, and between short GRBs with and without precursors. We discuss possible mechanisms to reproduce the observed precursor emission within the scenario of compact object mergers. The implications of our results on quantum gravity constraints are also discussed.

79 ASTRONOMY AND ASTROPHYSICS↗

Conductivity of composites containing ferromagnetic nanoparticles: The role of a magnetic field

A theory of conductivity is developed for metal-containing nanocomposites. An expression is obtained for the tunneling rate of an electron between nanoparticles. Three regimes of current flow are possible: the cases of weak, strong, and superstrong electric fields. In the weak-field regime, the electrons generated as a result of ionization of neutral nanoparticles are characterized by a nearly equilibrium distribution. The conductivity in this regime is calculated with the use of this nearly equilibrium distribution of electrons and the relationship between the spacing of neighboring particles and their radii. An expression is obtained for the electric conductivity as a function of temperature and a magnetic field (for ferromagnets) with regard to the distribution of nanoparticles with respect to radius and their volume density.

36 MATERIALS SCIENCE↗

A Method to Determine the Electric Field of Liquid Argon Time Projection Chambers using a UV Laser System and its Application in MicroBooNE

Liquid argon time projection chambers (LArTPCs) are today a standard detector technology for accelerator neutrino measurements, due to their high density, precise tracking, and calorimetric capabilities. An electric field (E-field) is required in such detectors to drift ionization electrons to the anode to be collected. The E-field of a TPC is often assumed to be uniform between the anode and the cathode. However, significant distortions can appear from effects such as mechanical distortions, failures, or the accumulation of space charge generated by cosmic rays. The latter is particularly relevant for detectors placed near the Earth’s surface and with large drift distances. To determine the E-field in situ, an ultraviolet (UV) laser system is installed in the MicroBooNE experiment at Fermi National Accelerator Laboratory. The purpose of this system is to provide precise measurements of the E-field, and to make it possible to correct for 3D spatial distortions due to E-field non-uniformities. Here we describe the methodology developed for deriving spatial distortions, the drift velocity and the E-field from UV-laser measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Formation of Wide Streamers during a Subnanosecond Discharge in Atmospheric-Pressure Air

Results are presented from experimental and computational studies of a subnanosecond breakdown of atmospheric-pressure air in a nonuniform electric field. It is shown that the ionization waves (streamers) formed in the prebreakdown stage have a nearly spherical or conical shape. The diameter of the streamer in its widest part is found to increase with increasing voltage and discharge gap length. For a rise time of the voltage pulse of ≈0.5 ns and its amplitude of ≈250 kV, streamers about 8 cm in diameter were observed in a 7-cm-long gap.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Reduced model for direct induction startup scenario development on MAST-U and NSTX-U

A reduced semi-empirical model using time-dependent axisymmetric vacuum field calculations is used to develop the prefill and feed-forward coil current targets required for reliable direct induction (DI) startup on the new MA-class spherical tokamaks, MAST-U and NSTX-U. The calculations are constrained by operational limits unique to each device, such as the geometry of the conductive elements and active coils, power supply specifications and coil heating and stress limits. The calculations are also constrained by semi-empirical models for sufficient breakdown, current drive, equilibrium and stability of the plasma developed from a shared database. A large database of DI startup on NSTX and NSTX-U is leveraged to quantify the requirements for achieving a reliable breakdown (I p ~ 20 kA). It is observed that without pre-ionization, STs access the large E/P regime at modest loop voltage (V loop ) where the electrons in the weakly ionized plasma are continually accelerating along the open field lines. This ensures a rapid (order millisecond) breakdown of the neutral gas, even without pre-ionization or high-quality field nulls. The timescale of the initial increase in I p on NSTX is reproduced in the reduced model provided a mechanism for impeding the applied electric field is included. Most discharges that fail in the startup phase are due to an inconsistency in the evolution of the plasma current (I p ) and equilibrium field or loss of vertical stability during the burn-through phase. Here, the requirements for the self-consistent evolution of the fields in the weakly and fully-ionized plasma states are derived from demonstrated DI startup on NSTX, NSTX-U and MAST. The predictive calculations completed for MAST-U and NSTX-U illustrate that the maximum I p ramp rate (dI p /dt) in the early startup phase is limited by the voltage limits on the poloidal field coils on MAST-U and passive vertical stability on NSTX-U.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measuring stellar populations, dust attenuation and ionized gas at kpc scales in 10010 nearby galaxies using the integral field spectroscopy from MaNGA

As one of the three major experiments of the fourth-generation Sloan Digital Sky Survey (SDSS-IV), the Mapping Nearby Galaxies at Apatch Point Observatory (MaNGA) survey has obtained high-quality integral field spectroscopy (IFS) with a resolution of 1–2 kpc for ∼ 10 4 galaxies in the local universe during its six-year operation from July 2014 through August 2020. It is crucial to reliably measure the physical properties of the different components in each spectrum before one can use the data for any scientific study. In the past years we have made lots of efforts to develop a novel technique of full spectral fitting, which estimates a model-independent dust attenuation curve from each spectrum, thus allowing us to break the degeneracy between dust attenuation and stellar population properties when fitting the spectrum with stellar population synthesis models. We have applied our technique to the final data release of MaNGA, and obtained measurements of stellar population properties and emission line parameters, as well as the kinematics and dust attenuation of both stellar and ionized gas components. In this paper we describe our technique and the content and format of our data products. The whole dataset is publicly available in Science Data Bank with the link https://doi.org/10.57760/sciencedb.j00113.00088 .

Physics↗

On Monte Carlo modeling of megavoltage photon beams: A revisited study on the sensitivity of beam parameters

Purpose: To commission Monte Carlo beam models for five Varian megavoltage photon beams (4, 6, 10, 15, and 18 MV). The goal is to closely match measured dose distributions in water for a wide range of field sizes (from 2x2 to 35x35 cm{sup 2}). The second objective is to reinvestigate the sensitivity of the calculated dose distributions to variations in the primary electron beam parameters. Methods: The GEPTS Monte Carlo code is used for photon beam simulations and dose calculations. The linear accelerator geometric models are based on (i) manufacturer specifications, (ii) corrections made by Chibani and Ma [''On the discrepancies between Monte Carlo dose calculations and measurements for the 18 MV Varian photon beam,'' Med. Phys. 34, 1206-1216 (2007)], and (iii) more recent drawings. Measurements were performed using pinpoint and Farmer ionization chambers, depending on the field size. Phase space calculations for small fields were performed with and without angle-based photon splitting. In addition to the three commonly used primary electron beam parameters (E{sub AV} is the mean energy, FWHM is the energy spectrum broadening, and R is the beam radius), the angular divergence ({theta}) of primary electrons is also considered. Results: The calculated and measured dose distributions agreed to within 1% local difference at any depth beyond 1 cm for different energies and for field sizes varying from 2x2 to 35x35 cm{sup 2}. In the penumbra regions, the distance to agreement is better than 0.5 mm, except for 15 MV (0.4-1 mm). The measured and calculated output factors agreed to within 1.2%. The 6, 10, and 18 MV beam models use {theta}=0 deg., while the 4 and 15 MV beam models require {theta}=0.5 deg. and 0.6 deg., respectively. The parameter sensitivity study shows that varying the beam parameters around the solution can lead to 5% differences with measurements for small (e.g., 2x2 cm{sup 2}) and large (e.g., 35x35 cm{sup 2}) fields, while a perfect agreement is maintained for the 10x10 cm{sup 2} field. The influence of R on the central-axis depth dose and the strong influence of {theta} on the lateral dose profiles are demonstrated. Conclusions: Dose distributions for very small and very large fields were proved to be more sensitive to variations in E{sub AV}, R, and {theta} in comparison with the 10x10 cm{sup 2} field. Monte Carlo beam models need to be validated for a wide range of field sizes including small field sizes (e.g., 2x2 cm{sup 2}).

43 PARTICLE ACCELERATORS↗

Nonadiabatic strong-field photoionization revisited: Detailed analysis

We develop a theoretical framework to interpret “bump-like” enhancements in the energy distribution of electrons emitted from cesium atoms subjected to intense infrared laser fields, as observed in a recent experiment. These emissions, detected at energies approaching twice the ponderomotive energy (2⁢𝑈 p ), indicate a mechanism where electrons are nonadiabatically ejected with substantial inward velocity following ionization. The bump-like features arise from returning trajectories that scatter off the residual ion. We interpret these experimental results classically using a periodically driven version of the Bohr model and quantum mechanically through Keldysh's adiabaticity parameter (𝛾 K ) and Reiss's continuum-state intensity parameter 𝒵 in a Coulomb-corrected version of the strong-field approximation (SFA) that incorporates “complex” electronic trajectories. Notably, our theoretical analysis shows that these emissions are independent of the specific short-range form of the atomic potential.

74 ATOMIC AND MOLECULAR PHYSICS↗

The alanine detector in BNCT dosimetry: Dose response in thermal and epithermal neutron fields

Purpose: The response of alanine solid state dosimeters to ionizing radiation strongly depends on particle type and energy. Due to nuclear interactions, neutron fields usually also consist of secondary particles such as photons and protons of diverse energies. Various experiments have been carried out in three different neutron beams to explore the alanine dose response behavior and to validate model predictions. Additionally, application in medical neutron fields for boron neutron capture therapy is discussed. Methods: Alanine detectors have been irradiated in the thermal neutron field of the research reactor TRIGA Mainz, Germany, in five experimental conditions, generating different secondary particle spectra. Further irradiations have been made in the epithermal neutron beams at the research reactors FiR 1 in Helsinki, Finland, and Tsing Hua open pool reactor in HsinChu, Taiwan ROC. Readout has been performed with electron spin resonance spectrometry with reference to an absorbed dose standard in a {sup 60}Co gamma ray beam. Absorbed doses and dose components have been calculated using the Monte Carlo codes FLUKA and MCNP. The relative effectiveness (RE), linking absorbed dose and detector response, has been calculated using the Hansen and Olsen alanine response model. Results: The measured dose response of the alanine detector in the different experiments has been evaluated and compared to model predictions. Therefore, a relative effectiveness has been calculated for each dose component, accounting for its dependence on particle type and energy. Agreement within 5% between model and measurement has been achieved for most irradiated detectors. Significant differences have been observed in response behavior between thermal and epithermal neutron fields, especially regarding dose composition and depth dose curves. The calculated dose components could be verified with the experimental results in the different primary and secondary particle fields. Conclusions: The alanine detector can be used without difficulty in neutron fields. The response has been understood with the model used which includes the relative effectiveness. Results and the corresponding discussion lead to the conclusion that application in neutron fields for medical purpose is limited by its sensitivity but that it is a useful tool as supplement to other detectors and verification of neutron source descriptions.

07 ISOTOPE AND RADIATION SOURCES↗

Simulated NMIS Imaging Data for an Unknown Object

This report presents simulated Nuclear Materials Identification System (NMIS) imaging data for an unclassified object, whose characteristics are initially unknown to the reader. This data will be used to test various analysis capabilities and was created with a simple deterministic ray-tracing algorithm. NMIS is a time-dependent coincidence counting system that is used to characterize both fissile and non-fissile materials undergoing nondestructive assay. NMIS characterizes materials by interrogating them with neutrons, either from an associated-particle deuterium-tritium (DT) neutron generator, which produces a time and directionally tagged monoenergetic beam of 14.1 MeV neutrons, or a time-tagged spontaneous fission source in an ionization chamber.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Experimental investigation of the response of an a-Si EPID to an unflattened photon beam from an Elekta Precise linear accelerator

The characteristics of an Elekta amorphous silicon (a-Si) electronic portal imaging device (EPID) in response to a 6 MV photon beam generated without a flattening filter, an unflattened beam, have been determined. The characteristics were then compared to those for a conventional photon beam generated with a flattening filter in the beam, a flattened beam, in order to determine the suitability of an a-Si EPID for transit dosimetry. The response of the EPID to the unflattened beam increased by 7.3% compared to the flattened beam, and copper buildup of 3 mm reduces the variation in the EPID response over air gaps ranging from 60 to 40 cm to within 2.5%. The scattering properties of the EPID with changing field size for the unflattened beam agree with those measured for a flattened beam to within 2%. Due to the minimal variation in the energy spectrum of the unflattened beam with the distance from the central axis, it was expected and experimentally found that the profile shape of the unflattened beam changes minimally with increasing phantom thickness. For an unflattened beam, EPID measured profiles with and without a phantom in the beam agree to within 2% using confidence limits. The difference between EPID and ionization chamber profiles measured at a depth of 5 cm in water is reduced compared to a flattened beam and remains unchanged with increasing phantom thickness. A difference of 4% was found between EPID profiles and the corresponding profiles measured with an ionization chamber measured in water over a range of phantom thickness. A calibration procedure was developed to convert EPID images to the equivalent absolute dose in water, at the EPID plane. A gamma evaluation was performed comparing the calibrated EPID images to dose measured with an ionization chamber array for rectangular fields and an IMRT segment. The fields were situated on axis and at 5 cm off axis with and without a 25 cm thick phantom in the beam. The gamma evaluation criteria of 3% and 3 mm were met within the field, for all fields examined. This study concludes that a-Si EPIDs are suitable dosimeters for IMRT treatments using unflattened photon beams with the advantage that the characteristics of the unflattened beam result in a reduction in the number of measurements necessary to calibrate an a-Si EPID as a transit dosimeter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of high-vacuum planar magnetron sputtering using an advanced magnetic field geometry

A permanent magnet in a new magnetic field geometry (namely, with the magnetization in the radial direction) was fabricated and used for high-vacuum planar magnetron sputtering using Penning discharge. Because of the development of this magnet, the discharge current and deposition rate were increased two to three times in comparison with the values attainable with a magnet in the conventional geometry. This improvement was because the available space for effective discharge of the energetic electrons for the ionization increased because the magnetic field distribution increased in both the axial and radial directions of discharge.

42 ENGINEERING↗

Study of space charge in the ICARUS T600 detector

The accumulation of positive ions, produced by ionizing particles crossing Liquid Argon Time Projection Chambers (LAr-TPCs), may generate distortions of the electric drift field affecting the track reconstruction of the ionizing events. These effects could become relevant for large LAr-TPCs operating at surface or at shallow depth, where the detectors are exposed to a copious flux of cosmic rays. We report a detailed study of such possible field distortions in the ICARUS T600 LAr-TPC has been performed analyzing a sample of cosmic muon tracks recorded with one T600 module operated at surface in 2001. The maximum track distortion turns out to be of few mm in good agreement with the prediction by a numerical calculation. As a cross-check, the same analysis has been performed on a cosmic muon sample recorded during the ICARUS T600 run at the LNGS underground laboratory, where the cosmic ray flux was suppressed by a factor $\sim 10^6$ by 3400 m water equivalent shielding. No appreciable distortion has been observed, confirming that the effects measured on surface are actually due to ion space charge.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Physical Conditions of Eta Car Complex Environment Revealed From Photoionization Modeling

The very massive star, Eta Carinae, is enshrouded in an unusual complex environment of nebulosities and structures. The circumstellar gas gives rise to distinct absorption and emission components at different velocities and distances from the central source(s). Through photoionization modeling, we find that the radiation field from the more massive B-star companion supports the low ionization structure throughout the 5.54 year period. The radiation field of an evolved O-star is required to produce the higher ionization . emission seen across the broad maximum. Our studies utilize the HST/STIS data and model calculations of various regimes from doubly ionized species (T= 10,000K) to the low temperature (T = 760 K) conditions conductive to molecule formation (CH and OH). Overall analysis suggests the high depletion in C and O and the enrichment in He and N. The sharp molecular and ionic absorptions in this extensively CNO - processed material offers a unique environment for studying the chemistry, dust formation processes, and nucleosynthesis in the ejected layers of a highly evolved massive star.

Verner, E. M.↗