Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “drops”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

Further Examinations of Bimodal SLD Ice Accretion in the NASA Icing Research Tunnel

An ice shape database has been created to document ice accretions on a 72-inch chord NACA 23012 airfoil model resulting from an exposure to a Supercooled Large Drop (SLD) icing cloud with a bimodal drop size distribution. The ice shapes created were documented with photographs, laser scanned surface measurements over a section of the model span, and measurement of the ice mass over the same section of each accretion. The icing conditions used in the test matrix were based upon previously measured ice shapes on the same model to connect the current database to previously measured information. Ice shapes resulting from the bimodal distribution as well as from equivalent mono-modal drop size distributions were obtained and compared. Results indicate that the ice shapes resulting from the bimodal drop size distributions had higher mass and volume values than their mono-modal distribution equivalents as well as having icing limits that extended further back on the chord of the model.

Aircraft↗

Validation of Heat Transfer Correlations in Line Chill-Down Tests of Cryogenic Fluid in SINDA/FLUINT

Line chill-down is an important process in cryogenic tank propellant management, storage, and usage Complex flow dynamics during these processes: boiling heat transfer (film, transition, and nucleate) Understanding boiling phenomena can lead to efficient line chill-down systems that use less propellant, propellant stored, reducing cost for space missions Line Chill-down heat transfer was modelled using SINDA/FLUINT version 5.8 (SF) Multiple chill-down tests were modelled using: heat transfer correlations readily available in SF using HTN/HTC TIES heat transfer empiricisms developed by the University of Florida (UF) based on a series of liquid nitrogen chill-down tests using SF HTU TIES Chill-down tests modelled: liquid nitrogen tests conducted by the University of Florida horizontal flow, upward flow, and downward flow (Reynolds Numbers ranging 850-231,000)liquid hydrogen tests conducted by NASA Glenn Research Center vertical upward flow (Reynolds Number range of 18,400 - 433,000)The flow rate was measured far downstream of the test section, near the system exit. Where to set the flow rate? SF was highly sensitive, and sometime unstable, setting the test flow rate downstream (the outlet) of the test section model and setting the test pressure upstream (the inlet) of the test section model higher flow rate oscillations at the entrance of the model's test section SF was more stable setting the test flow rate upstream (than the downstream flow rate set case)test pressure was used as an inlet (SF plenum) to set the thermodynamic state (temperature and quality) coming into the system setting the appropriate downstream pressure was the unknown. The pressure drops predicted by SF for the downstream set flow rate boundary condition were much smaller than test section measured pressure drops. The multiphase pressure drop correlations used internally in SF may need to be adjusted. Models with an upstream flow rate set assumed a pressure drop that was small

cryogenic modeling↗

Predicted Ice Shape Formations on a Boundary Layer Ingesting Engine Inlet

Computational ice shapes were generated on the boundary layer ingesting engine nacelle of the D8 Double Bubble aircraft. The computations were generated using LEWICE3D, a well-known CFD icing post processor. A 50-bin global drop diameter discretization was used to capture the collection efficiency due to the direct impingement of water onto the engine nacelle. These discrete results were superposed in a weighted fashion to generate six drop size distributions that span the Appendix C and O regimes. Due to the presence of upstream geometries, i.e. the fuselage nose, the trajectories of the water drops are highly complex. Since the ice shapes are significantly correlated with the collection efficiency, the upstream fuselage nose has a significant impact on the ice accretion on the engine nacelle. These complex trajectories are caused by the ballistic nature of the particles and are thus exacerbated as particle size increases. Shadowzones are generated on the engine nacelle, and due to the curvature of the nose of the aircraft the shadowzone boundary moves from lower inboard to upper outboard as particle size increases. The largest particle impinging one the engine nacelle from the 50-bin discretization was the 47 um drop diameter. As a result, the MVD greater than 40 um Appendix O conditions were characterized by extremely low collection efficiency on the engine nacelle for these direct impingement simulations.

Porter, Christopher↗

A Simple Thermoelectric Droplet Generator

A new design for a droplet generator capable of producing single droplets is presented. The design relies on thermoelectric heating to vaporize water at the interface between a droplet and a blunt syringe tip. While other designs require careful tuning to produce drops of varying size, this technique enables the simple creation of droplets of any size within a range. The design is of simple construction and can be completed with off-the-shelf components, and relies on resistive heating to vaporize water at or near the droplet-nozzle interface and release the droplets. We demonstrated that the design can be used to produce droplets as small as 110 µm or as large as 2 mm. Drop size is limited by the geometry of the nozzle since water must wet the tip of the nozzle and hang under gravity. Our experiments showed that released droplets have relatively small disturbances introduced by the release mechanism when compared to competing techniques. These disturbances were intermittently observed as the voltage, pulse width, and drop size were changed, and optimal settings were determined for the smallest drop sizes produced.

Andrew Work↗

Pressure Gradient and Gas Hold-Up in Two-Phase Flows through Porous Media in Microgravity

Single and two-phase flow through porous media are encountered on ground and in space in numerous applications related to life support systems, fuel cells, chemical/materials processing and transporting nutrients to plants. These systems operate differently in the microgravity environment encountered in space travel because the density differences no longer cause the phases to separate or “drain” under the body force of gravity. In the absence of gravity, the interfacial or capillary forces play a more significant role in determining the operational variables such as phase distribution, liquid holdup, and pressure drop especially when the liquid inertia and viscous forces are at minimum. Lower liquid flow rates in air-water two-phase flows represent the case for most of the space processes that depend on two-phase flows in porous media. The Packed Bed Reactor Experiment (PBRE) was developed and flown on the International Space Station (ISS) by NASA to extend a series of fundamental studies of gas-liquid flows through porous media. The goal of the this series of flight experiments (PBRE-1 and PBRE-2) is to better understand the hydrodynamics of two phase flows in porous media in flow regimes dominated by inertia and viscous effects and understanding the role of the interfacial forces and their role in determining the flow dynamics. The flight experiments were preceded by a series of low gravity experiments performed on the low gravity aircraft. These experiments led to the development of a semi-empirical two-phase pressure drop and flow pattern transition in support of a number of reactor beds planned for water reclamation processes onboard of the international space station. The PBRE flight experiment was designed to deliver a wide range of tightly controlled gas (nitrogen) and liquid (water) flows to one of two interchangeable test sections differing only in the type of internal packing material. In this presentation, we describe the PBRE-2 experiment and present preliminary low gravity data on pressure drop and gas hold-up and compare with semi-empirical model pressure drop predictions.

Brian Motil↗

Design and Technology Maturation of the Stratospheric Projectile Experiment of Entry Dynamics

The supersonic and transonic dynamic stability of blunt-body reentry vehicles currently poses large risks in all of NASA’s ongoing entry missions (MSR SRL, MSR EES, and Dragonfly). These projects have allocated millions of dollars to testing and modeling efforts to buy down risk by using the current state-of-the-art (SoA) facilities at NASA’s disposal. While these facilities have heritage in supplying dynamics data to reentry missions, their availability is severely limited – particularly with the high number of concur-rent projects requesting simultaneous testing– and are costly when considering the science density per dollar. None of the current SoA facility methodologies allow the test model to have the dynamics fully develop through a flight relevant free-stream profile and as such require extrapolations with resultant high uncertainties in order to relate the test dynamics to flight expectations. SPEED is a NASA Ames Center Innovation Fund (CIF) project that is developing a highly tailorable and cost-effective test methodology to better assess the dynamic stability of blunt-body reentry vehicles via a stratospheric balloon flight. This is accomplished by dropping a suite of instrumented capsules from a stratospheric balloon to gain a statistically relevant dataset of scaled reentry vehicles in mission relevant free-flight conditions. This presentation will walk through how the test methodology is being implemented specifically for the Mars Sample Return (MSR) Earth Entry System (EES) geometry in an awarded Flight Opportunities Program (FOP) test flight in early CY24. SPEED Application to MSR: SPEED consists of three main mechanical systems: the Drop Platform, the Projectile, and the test Capsule. SPEED is being developed as a set of guidelines and recommendations for how to test with the proposed Concept of Operations (Conops) since the specific design parameters will vary depending on the specific project’s reference trajectory and entry vehicle design. As such, this presentation will walk through the development time-line as shown in Fig. 2. This is meant to serve as a blueprint for further missions as desired. Mechanical and Avionics Design. The SPEED test platform designed for the MSR-EES capsule geometry with nominal entry parameters has the ability to carry 10 Capsules to altitude instrumented with: 1. 3-Axis Accelerometer 2. IMU 3. Gyroscope 4. Magnetometer 5. Pressure Transducer cruciform 6. Uplook and Horizon Cameras To package the avionics/instrumentation suite, the capsule is approximately 1’ in diameter with the Outer Mold Line (OML) centroid-scaled from the full EES design. The internal volume is gutted and custom-shaped to fit the desired instrumentation suite, as well as to allow for the positioning of ballast mass such that the Center of Gravity is analogous to the flight vehicle. All structural components in the Capsule and Projectile are 3D printed, which significantly reduces the cost of each flight unit to around $1500 including all instrumentation, avionics, and structural components. Flight Conops. The test Capsule is accelerated to the desired altitude and Mach number while stowed in the Projectile, a missile-like vehicle consisting of steel ballast in the nose, a low-drag OML, and an Ejection Mechanism to reliably release the Capsule into the free-flow supersonic conditions. For the MSR-EES design, the capsule employs ~3kg of ballast mass at the nose to accelerate the 1.25kg test Capsule to ~Mach 1.7 at 23km altitude. This requires an initial release altitude of 40km, the quoted limit of a 80kg payload by the FOP-contracted balloon provider. Once the Ejection Mechanism avionics detect the proper conditions, the spring-loaded Ejection Mechanism will release and – guided by the sabot – expose the test Capsule to the desired test conditions for ~5 seconds of free-flight in the supersonic/transonic regimes. Dynamics in the subsonic regime will also be captured with the instrumentation suite with post-flight recovery operations aimed at recovering the high-G-load capable SD cards after the planned hard impact landings. Testing and Development: In the few months the SPEED project has worked the development of MSR-EES flight test, the team has performed lab and drone based testing which this presentation will overview. After the first design phase, the team fabricated Engineering Demonstration Units (EDUs) of all subsystems to perform validation testing shown in Fig. 5. After validation was completed on the subsystem level, a drone-drop test was performed at the recreational flight ceiling of 400ft altitude to assess the SPEED systems in a flight environment. Parameters such as in-flight stability, hard impact landing performance, and avionics performance were quantified and qualified. The FY23 CIF will culminate in a helicopter drop test aboard an Air National Guard Blackhawk. This will prepare the team for the CY24 FOP stratospheric balloon flight that should provide the final verification to begin offering the test platform for mission support. Focus of Presentation: This presentation will outline the technology maturation path of the SPEED implementation to the MSR-EES capsule baseline as well as the details regarding the mechanical system, avionics and instrumentation, and flight operations. Note that a complementary presentation is being submitted for a methodology overview of the SPEED test platform, introducing the testing technique and benefits as well as the full application space of the technology.

pitch damping coefficient↗

Laser-Processed Condensing Heat Exchanger for Space Applications

In sizing a condensing heat exchanger for space life support systems, there is a limit to allowable pressure drop along with a required vapor recuperation rate. This sizing is performed by using known heat transfer and pressure drop correlations in a numerical model. Dimpling the surface of an air-liquid channeled heat exchanger increases the convective heat transfer rate however creates difficulties within the numerical model as the flat plate correlations are no longer accurate. To increase the fidelity of the numerical model used for sizing the heat exchanger Computational Fluid Dynamics (CFD) with an SST k-ω turbulence model was performed on a periodic portion of the heat exchanger. Through CFD modeling a heat flux and pressure drop was measured across the heat exchanger channel, this information was used to create a localized Nusselt number that was incorporated into the numerical model along with a more accurate pressure drop due to the dimpled surface. Additionally, through modeling the heat exchanger after manufacturing and assembly in Computer Aided Drafting (CAD) software there was an increase in the measurement accuracy of geometric features which was incorporated into the numerical model for further increase in fidelity.

heat exchanger↗

Atmospheric, Non-Combusting Droplet Sizing and Spray Imaging Results From a Non-Proprietary Aero Gas Turbine Engine Pressure Swirl Atomizer using Shadowgraphy and Planar Laser Scatter

Members from industry and federal agencies of the United States have developed a collaborating group focused on improving the understanding of the atomization processes common to gas turbine engines. The group is aimed on providing high quality data using x-ray diagnostics in the internal geometry and the near-field dense spray as well as optical diagnostics in the visible spectrum, downstream of the nozzle. This paper reports results from one of the two non-proprietary injectors designs from the group: the primary-secondary injector. In particular, we characterize the spray from only the primary, pressure-swirl atomizing circuit using water through the nozzle. We observed Sauter mean diameter decreased with increased water pressure drop across the nozzle. SMD was also collected at three axial distances and showed decreased size with distance from the nozzle. Planar laser sheet droplet scattering provided qualitative assessment of the spray. Higher water pressure drops provided better atomization than lower pressure drops. The addition of swirling air flow through the injector alleviates and improves the atomization quality, particularly at the lower water pressure drops.

optical diagnostics↗

NASA Glenn Icing Research Tunnel: 2014 Cloud Calibration Procedure and Results

The results of the December 2013 to February 2014 Icing Research Tunnel full icing cloud calibration are presented. The calibration steps included establishing a uniform cloud and conducting drop size and liquid water content calibrations. The goal of the calibration was to develop a uniform cloud, and to generate a transfer function from the inputs of air speed, spray bar atomizing air pressure and water pressure to the outputs of median volumetric drop diameter and liquid water content. This was done for both 14 CFR Parts 25 and 29, Appendix C ('typical' icing) and soon-to-be released Appendix O (supercooled large drop) conditions.

liquid water content↗

NASA Glenn Icing Research Tunnel: 2014 Cloud Calibration

The results of the December 2013 to February 2014 Icing Research Tunnel full icing cloud calibration are being presented to the SAE AC-9C committee, as represented in the 2014 cloud calibration report. The calibration steps included establishing a uniform cloud and conducting drop size and liquid water content calibrations. The goal of the calibration was to develop a uniform cloud, and to generate a transfer function from the inputs of air speed, spray bar atomizing air pressure and water pressure to the outputs of median volumetric drop diameter and liquid water content. This was done for both 14 CFR Parts 25 and 29, Appendix C (typical icing) and soon-to-be released Appendix O (supercooled large drop) conditions.

drop size↗

Electric field variations during substorms: OGO-6 measurements

The OGO-6 electric field measurements make it clear that the general pattern of high latitude electric fields in magnetic time-invariant latitude coordinates is not highly variable and that when unusual variations, or field distributions, occur they are relatively isolated in time and spatial extent. Thus, electric field changes on a global scale cannot, in general, be evoked as a direct cause of substorms. Polar traverses along the 18(h) to 6(h) magnetic time meridian show that the sum of potential drops across the evening auroral belt and morning auroral belt approximately equals the potential drop across the polar cap. The integrated polar cap potential drop ranges from 20 to 100 keV and values in the center of this range are most common under conditions of moderate magnetic disturbance. Roughly near 18(h) magnetic local time, a latitudinally narrow strip at the transition between auroral belt and polar cap fields exhibits unusually large field fluctuations immediately following the sudden onset of a negative bay at later magnetic local times. It appears likely that this spatially isolated correlation is related to an effect rather than a cause of substorm enhancement.

Heppner, J. P.↗

Static aerodynamic characteristics of the S-IC booster/GAC H-33 orbiter launch vehicle configuration

This test at the trisonic tunnel was divided into two parts. The first part utilized the H-33 orbiter with drop tanks and cradle mounted on an S-IC booster with 75 square-foot fins oriented 45 deg off the horizontal and vertical reference planes. Runs were initially made to determine the optimum incidence angle to be used for the remainder of the tests. The angle so determined was 0 degrees. Additional testing was performed with drop tanks removed, orbiter vertical tail removed, drop tanks and orbiter wing removed, booster fins removed and booster fins located in the horizontal and vertical reference planes. The second part utilized the H-33 orbiter and cradle only, sting mounted on a strain gage balance. These data were used in conjunction with test number 504 (orbiter alone on balance) to determine cradle effects.

Sims, J. F.↗

Fluorescence activated cell sorting.

An instrument has been developed for sorting biological cells. The cells are rendered differentially fluorescent and incorporated into a small liquid stream illuminated by a laser beam. The cells pass sequentially through the beam, and fluorescent light from the cells gives rise to electrical signals. The stream is broken into a series of uniform size drops downstream of the laser. The cell signals are used to give appropriate electrostatic charges to drops containing the cells. The drops then pass between two charged plates and are deflected to appropriate containers. The system has proved capable of providing fractions containing large numbers of viable cells highly enriched in a particular functional type.

Bonner, W. A.↗

Comparative cut-bar thermal conductivity apparatus.

Construction details, error analysis, and typical data for a rapid comparative device for thermal conductivity measurements are presented. The apparatus consists of a comparative cut-bar arrangement contained in a bell-jar. The cylinder shaped specimen is placed between two ARMCO-iron meter bars of the same diameter. The upper bar is equipped with a heater, while the lower one is terminated in a heat sink. The temperature gradient along the bars is measured with a series of copper/constantan microthermocouples, spot welded to them. The assembly is held together by loading the bars to a desired pressure, via a pneumatic cylinder. Contact resistance at the boundaries between the specimen and the meter bars is minimized by using a Hg/In/Ga alloy film at the interface and sufficient loading force. The gradients determined for the meter bars then may be extrapolated to the boundaries yielding the temperature drop along the specimen. Using two different length specimens, the magnitude of the temperature drop across the interface can be computed, or the true gradient along the specimen can be obtained from the difference in overall temperature drops and lengths.

Gaal, P. S.↗

Electric fields in the magnetosphere.

Two techniques, tracking the motions of Ba(+) clouds and measuring the differences in floating potential between symmetric double probes, have been highly successful in: (1) demonstrating the basic convective nature of magnetospheric electric fields, (2) mapping the global patterns of convection at upper ionosphere levels, and (3) revealing the physics of electric currents in the ionosphere and the importance of magnetosphere-ionosphere feedback in altering the imposed convection. The basic pattern of anti-solar convection across the polar cap and night toward day convection in both the evening and morning sectors at auroral belt latitudes persists at all levels of activity. The dawn-dusk potential drop across the polar cap (anti-solar convection) ranges from 20 to 100 kilovolts with the most typical values in the center of this range. The sum of morning and evening (night toward day convection) potential drops in the adjacent auroral belts roughly equals the polar cap drop in the opposite sense as expected.

Heppner, J. P.↗

Some injector element detail effects on screech in hydrogen-oxygen rockets

An experimental investigation was conducted to learn more about how the specific details of a concentric tube injection element affect the screech characteristics of a hydrogen-oxygen rocket engine. The four variables investigated were (1) impingement angle, (2) oxidizer tube blunt base thickness, (3) oxidizer tube recess and extension, and (4) oxidizer tube-annulus concentricity. Tests were made using a 27.34-cm (10.77-in.) diameter heat sink combustor at nominally 300-psia chamber pressure. All of the test variables were investigated using a 157 element circular pattern injector. Additional oxidizer tube recess tests were made with a 421 element hexagonal pattern injector. Tests were conducted over the oxidant-fuel ratio range of 4 to 6. Stability evaluation for each configuration was made using the hydrogen temperature rating technique. Several element configurations were also cold flow tested using nitrogen and water as simulants. The element detail changes resulted in changes in hydrogen injector pressure drop even though the physical injection area was constant for all similar tests in both hot firing and cold flow tests. These changes in injector pressure drop produced changes in combustion stability. The data were correlated with a modified version of a previously reported injection area ratio correlation. By interpreting changes in injector pressure drop as changes in injector hydrogen flow resistance, the data were compared with a hydrogen flow response stability model and were found to be in agreement.

Hannum, N. P.↗

Viscous pour point of microquantities of fluid lubricants

A method is described involving the measurement of the viscous desolidification (pour) point of wax-free lubricant fluids. This method is especially useful for pour point testing of experimental quantities, since only six to sixteen drops of the oil are required for a single determination (automatically performed in duplicate) with nearly full recovery of the sample. The technique consists of: (1) rapidly freezing a small, predetermined amount of the oil on the side of a small test tube to form a frozen drop of given dimensions; (2) immersing duplicates of the charged and stoppered tubes into a cold bath; and (3) measuring the temperature when the drop front has moved a predetermined distance as the bath warms up.

Gardos, M. N.↗

The effects of notch filters on the correlation properties of a PN signal

With wideband pseudo-noise (PN) communications systems, it is sometimes desirable to supplement the inherent interference rejection capabilities by adding notch filters to attenuate relatively narrowband interference. This correspondence presents an investigation of the effects of notch filters on the performance of PN correlation receivers. A theoretical analysis of the correlation drop due to filter distortion has been conducted and confirmed by experimentation. Additional measurements and analysis have established the trade-off between correlation drop and interference suppression as a function of interference bandwidth. A typical result is that by incurring a penalty of a 1-dB drop in correlation peak, interfering signals having bandwidths of 2 to 3% of the PN chip rate can be attenuated by 25 dB.

Sussman, S. M.↗