Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “detect and avoid”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

How gravitational lensing helps γ-ray photons avoid γ – γ absorption

We investigate potential γ – γ absorption of γ-ray emission from blazars arising from inhomogeneities along the line of sight, beyond the diffuse Extragalactic Background Light (EBL). As plausible sources of excess γ – γ opacity, we consider (1) foreground galaxies, including cases in which this configuration leads to strong gravitational lensing, (2) individual stars within these foreground galaxies, and (3) individual stars within our own galaxy, which may act as lenses for microlensing events. We found that intervening galaxies close to the line of sight are unlikely to lead to significant excess γ – γ absorption. This opens up the prospect of detecting lensed gamma-ray blazars at energies above 10 GeV with their gamma-ray spectra effectively only affected by the EBL. The most luminous stars located either in intervening galaxies or in our galaxy provide an environment in which these gamma-rays could, in principle, be significantly absorbed. However, despite a large microlensing probability due to stars located in intervening galaxies, γ-rays avoid absorption by being deflected by the gravitational potentials of such intervening stars to projected distances ({sup i}mpact parameters{sup )} where the resulting γ – γ opacities are negligible. Thus, neither of the intervening excess photon fields considered here, provide a substantial source of excess γ – γ opacity beyond the EBL, even in the case of very close alignments between the background blazar and a foreground star or galaxy.

79 ASTRONOMY AND ASTROPHYSICS↗

Recoil-Implantation Of Multiple Radioisotopes Towards Wear Rate Measurements And Particle Tracing In Prosthetic Joints

This study demonstrates a new method of radioisotope labeling of ultra-high molecular weight polyethylene inserts in prosthetic joints for wear studies. The radioisotopes {sup 97}Ru, {sup 100}Pd, {sup 100}Rh, and {sup 101m}Rh are produced in fusion evaporation reactions induced by {sup 12}C ions in a {sup 92}Zr target foil. The fusion products recoil-implant into ultra-high molecular weight polyethylene plugs, machined to fit into the surface of the inserts. During laboratory simulations of the joint motion, a wear rate of the labeled polyethylene may be measured and the pathways of wear debris particles can be traced by detecting characteristic gamma-rays. The concentration profiles of the radioisotopes extend effectively uniformly from the polyethylene surface to a depth of about 4 {mu}m. The multiplicity of labeling and the use of several gamma-ray lines aids with avoiding systematic measurement uncertainties. Two polyethylene plugs were labeled and one was fitted into the surface of the tibial insert of a knee prosthesis, which had been worn in. Actuation over close to 100,000 cycles with a 900 N axial load and a 24 deg. flexion angle removed (14{+-}1)% of the gamma-ray activity from the plug. Most of this activity dispersed into the serum lubricant identifying this as the important debris pathway. Less than 1% activity was transferred to the femoral component of the prosthesis and the measured activity on the tibial tray was insignificant. Assuming uniform wear across the superior surface of the insert, a wear rate of (12{+-}3) mm{sup 3}/Megacycle was determined. This is consistent with wear rate measurements under similar conditions using other techniques.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

THE CHANDRA VARIABLE GUIDE STAR CATALOG

Variable stars have been identified among the optical-wavelength light curves of guide stars used for pointing control of the Chandra X-ray Observatory. We present a catalog of these variable stars along with their light curves and ancillary data. Variability was detected to a lower limit of 0.02 mag amplitude in the 4000-10000 A range using the photometrically stable Aspect Camera on board the Chandra spacecraft. The Chandra Variable Guide Star Catalog (VGUIDE) contains 827 stars, of which 586 are classified as definitely variable and 241 are identified as possibly variable. Of the 586 definite variable stars, we believe 319 are new variable star identifications. Types of variables in the catalog include eclipsing binaries, pulsating stars, and rotating stars. The variability was detected during the course of normal verification of each Chandra pointing and results from analysis of over 75,000 guide star light curves from the Chandra mission. The VGUIDE catalog represents data from only about 9 years of the Chandra mission. Future releases of VGUIDE will include newly identified variable guide stars as the mission proceeds. An important advantage of the use of space data to identify and analyze variable stars is the relatively long observations that are available. The Chandra orbit allows for observations up to 2 days in length. Also, guide stars were often used multiple times for Chandra observations, so many of the stars in the VGUIDE catalog have multiple light curves available from various times in the mission. The catalog is presented as both online data associated with this paper and as a public Web interface. Light curves with data at the instrumental time resolution of about 2 s, overplotted with the data binned at 1 ks, can be viewed on the public Web interface and downloaded for further analysis. VGUIDE is a unique project using data collected during the mission that would otherwise be ignored. The stars available for use as Chandra guide stars are generally 6-11 mag and are commonly spectral types A and later. Due to the selection of guide stars entirely for positional convenience, this catalog avoids the possible bias of searching for variability in objects where it is to be expected. Statistics of variability compared to spectral type indicate the expected dominance of A-F stars as pulsators. Eclipsing binaries are consistently 20%-30% of the detected variables across all spectral types.

79 ASTRONOMY AND ASTROPHYSICS↗

Two-Color Ultrafast Photoexcited Scanning Tunneling Microscopy

We report on two-color two-photon photoexcitation of a metal surface driven by ultrafast laser pulses and detected with a scanning tunneling microscope (STM) tip as a proximate anode. Results are presented for two cases: (i) where the tip is retracted from the surface far enough to prohibit tunneling, and (ii) where the tip is within tunneling range of the surface. A delay-modulation technique is implemented to isolate the two-color photoemission from concurrent one-color two-photon photoemission and provide subpicosecond time-resolved detection. When applied with the tip in tunneling range, this approach effectively isolates the two-photon photoexcited current signal from the conventional tunneling current and enables subpicosecond time-resolved detection of the photoexcited surface electrons. The advantage of the two-color approach is highlighted by comparison with the one-color case where optical interference causes thermal modulation of the STM tip length, resulting in tunneling current modulations that are orders of magnitude larger than the current due to photoexcitation of surface electrons. By completely eliminating this interference, and thereby avoiding thermal modulation of the STM tip length, the two-color approach represents an important step toward the ultimate goal of simultaneous subnanometer and subpicosecond measurements of surface electron dynamics by ultrafast-laser-excited STM.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Detection of Digital Elevation Model Errors Using X-band Weather Radar

Flight in Instrument Meteorological Conditions requires pilots to manipulate flight controls while referring to a Primary Flight Display. The Primary Flight Display indicates aircraft attitude along with, in some cases, many other state variables such as altitude, speed, and guidance cues. Synthetic Vision Systems have been proposed that overlay the traditional information provided on Primary Flight Displays onto a scene depicting the location of terrain and other geo-spatial features.Terrain models used by these displays must have sufficient quality to avoid providing misleading information. This paper describes how X-band radar measurements can be used as part of a monitor, and/or maintenance system, to quantify the integrity of terrain models that are used by systems such as Synthetic Vision. Terrain shadowing effects, as seen by the radar, are compared in a statistical manner against estimated shadow feature elements extracted from the stored terrain model from the perspective of the airborne observer. A test statistic is defined that enables detection of errors as small as the range resolution of the radar. Experimental results obtained from two aircraft platforms hosting certified commercial-off-the-shelf X-band radars test the premise and illustrate its potential.

Young, Steven D.↗

Short Time Scale Stability Monitoring of GOES-16 Visible Channels by Utilizing Daily Inter-Calibration Events with both VIIRS and MODIS Sensors

The CERES project relies on MODIS, VIIRS and geostationary (GEO) imager retrieved cloud properties to compute surface fluxes and convert CERES and GEO radiances into TOA fluxes. The CERES TOA and surface fluxes need to be of climate quality and any anomaly or discontinuity in the calibration of the MODIS, VIIRS, GEO radiances need to be mitigated or avoided. Due to the nature of the CERES instrument calibration, there is a lag time of 3 months before the processing of the CERES product. This allows the CERES team to investigate any unforeseen problems in the input datasets or GEO calibration discontinuities or anomalies before processing. The CERES geostationary imager calibration team is developing a daily monitoring system of GEO, MODIS and VIIRS visible channel radiances in order to detect any day to day discontinuities as part of the CERES/GEO coincident ray-matching calibration efforts. a GEO discontinuity can be detected using two MODIS and 2 VIIRS sensors simultaneously, thus increasing the sampling greatly over a single GEO/LEO radiance pairs. This method is being automated and has already detected three erroneous radiometric calibration events, which were verified with the GOES-16 event log page. One advantage of daily monitoring is that the time period needed to verify calibration drifts is reduced and the confidence to detect even smaller magnitudes of the calibration drift is increased over monthly monitoring. By utilizing Terra and Aqua MODIS and NPP and NOAA20 VIIRS imagers to inter-calibrate GOES-16, the GOES-16 calibration can be referenced to anyone of these imagers. If the CERES project transitions between the Aqua-MODIS imager to the NOAA20 VIIRS imager, the NOAA-20 VIIRS imager can be radiometrically scale to Aqua-MODIS calibration, thus avoiding a GOES-16 calibration discontinuity.

David Robert Doelling↗

Is a Short-Interval Postradiation Mammogram Necessary After Conservative Surgery and Radiation in Breast Cancer?

Purpose: To examine, in a retrospective study, whether the initial posttreatment mammogram offers any benefit to patients. Methods and Materials: Patients were selected who had radiation after breast-conservation therapy from 1995 through 2005 and had follow-up mammography at University of California-Los Angeles (UCLA) within 1 year of completing radiotherapy. Results of the initial follow-up mammogram were analyzed to determine the yield of this initial mammogram. Results: Between 1995 and 2005, 408 patients treated with breast-conserving therapy and radiation had follow-up mammograms at UCLA within 1 year of completion of radiation. Median age at radiation completion was 56.9 years. Median interval between radiation and the initial mammogram was 3.1 months. Ten patients were found to have suspicious findings on the initial postradiation mammogram, prompting biopsy, but only 2 were found to have recurrent cancer. None of those lesions were palpable. In both cases the recurrences were ductal carcinoma in situ. Thus, the yield of the initial postoperative mammogram as compared with physical examination findings is estimated at 0.49 recurrences detected per 100 mammograms performed (95% confidence interval 0.059-1.759). Conclusions: The yield of the initial postradiation mammography at UCLA seems to be low, and only noninvasive carcinomas were found. Our data support the rationale to avoid the initial short-interval postradiation mammography and evaluate patients at 12 months.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Real-Time Verification of a High-Dose-Rate Iridium 192 Source Position Using a Modified C-Arm Fluoroscope

Purpose: High-dose-rate (HDR) brachytherapy misdeliveries can occur at any institution, and they can cause disastrous results. Even a patient's death has been reported. Misdeliveries could be avoided with real-time verification methods. In 1996, we developed a modified C-arm fluoroscopic verification of an HDR Iridium 192 source position prevent these misdeliveries. This method provided excellent image quality sufficient to detect errors, and it has been in clinical use at our institutions for 20 years. The purpose of the current study is to introduce the mechanisms and validity of our straightforward C-arm fluoroscopic verification method. Methods and Materials: Conventional X-ray fluoroscopic images are degraded by spurious signals and quantum noise from Iridium 192 photons, which make source verification impractical. To improve image quality, we quadrupled the C-arm fluoroscopic X-ray dose per pulse. The pulse rate was reduced by a factor of 4 to keep the average exposure compliant with Japanese medical regulations. The images were then displayed with quarter-frame rates. Results: Sufficient quality was obtained to enable observation of the source position relative to both the applicators and the anatomy. With this method, 2 errors were detected among 2031 treatment sessions for 370 patients within a 6-year period. Conclusions: With the use of a modified C-arm fluoroscopic verification method, treatment errors that were otherwise overlooked were detected in real time. This method should be given consideration for widespread use.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Replication-competent human adenovirus 11p vectors can propagate in Vero cells

The use of continuous cell lines derived from the African green monkey kidney (AGMK) has led to major advances in virus vaccine development. However, to date, these cells have not been used to facilitate the creation of human adenoviruses because most human adenoviruses undergo abortive infections in them. Here, we report the susceptibility of AGMK-derived cells to adenovirus 11p (Ad11p) infection. First, we showed that CD46 molecules, which act as receptors for Ad11p, are expressed in AGMK cells. We then monitored Ad11p replication by measuring GFP expression as an indicator of viral transcription. We found that AGMK-derived cells were as capable as carcinoma cells at propagating full-length replication-competent Ad11p (RCAd11p) DNA. Of the AGMK cell lines tested, Vero cells had the greatest capacity for adenovirus production. Thus, AGMK cells can be used to evaluate RCAd11p-mediated gene delivery, and Vero cells can be used for the production of RCAd11pGFP vectors at relatively high yields. - Highlights: • Africa green monkey cell lines were monitored for human adenovirus 11p GFP vector infection. • Human CD46 molecules were detectable in these monkey cell lines. • Adenovirus 11p GFP vector can be propagated in Vero cells increases the safety of Ad11p-based vectors for clinical trials. • To use Vero cells for preparation of Ad11p vector avoids the potential inclusion of oncogenes from tumor cells.

60 APPLIED LIFE SCIENCES↗

PLUTINO DETECTION BIASES, INCLUDING THE KOZAI RESONANCE

Because of their relative proximity within the trans-Neptunian region, the plutinos (objects in the 3:2 mean-motion resonance with Neptune) are numerous in flux-limited catalogs, and well-studied theoretically. We perform detailed modeling of the on-sky detection biases for plutinos, with special attention to those that are simultaneously in the Kozai resonance. In addition to the normal 3:2 resonant argument libration, Kozai plutinos also show periodic oscillations in eccentricity and inclination, coupled to the argument of perihelion ({omega}) oscillation. Due to the mean-motion resonance, plutinos avoid coming to pericenter near Neptune's current position in the ecliptic plane. Because Kozai plutinos are restricted to certain values of {omega}, perihelion always occurs out of the ecliptic plane, biasing ecliptic surveys against finding these objects. The observed Kozai plutino fraction f{sub koz}{sup obs} has been measured by several surveys, finding values between 8% and 25%, while the true Kozai plutino fraction f{sub koz}{sup true} has been predicted to be between 10% and 30% by different giant planet migration simulations. We show that f{sub koz}{sup obs} varies widely depending on the ecliptic latitude and longitude of the survey, so debiasing to find the true ratio is complex. Even a survey that covers most or all of the sky will detect an apparent Kozai fraction that is different from f{sub koz}{sup true}. We present a map of the on-sky plutino Kozai fraction that would be detected by all-sky flux-limited surveys. This will be especially important for the Panoramic Survey Telescope and Rapid Response System and Large Synoptic Survey Telescope projects, which may detect large numbers of plutinos as they sweep the sky. f{sub koz}{sup true} and the distribution of the orbital elements of Kozai plutinos may be a diagnostic of giant planet migration; future migration simulations should provide details on their resonant Kozai populations.

79 ASTRONOMY AND ASTROPHYSICS↗

Retrieval of Aerosol Optical Depth in Vicinity of Broken Clouds from Reflectance Ratios: Sensitivity Study

We conducted a sensitivity study to better understand the potential of a new method for retrieving aerosol optical depth (AOD) under partly cloudy conditions. This method exploits reflectance ratios in the visible spectral range and provides an effective way to avoid three-dimensional (3D) cloud effects. The sensitivity study is performed for different observational conditions and random errors in input data. The results of the sensitivity study suggest that this ratio method has the ability to detect clear pixels even in close proximity to clouds. Such detection does not require a statistical analysis of the two-dimensional (2D) horizontal distribution of reflected solar radiation, and thus it could be customized for operational retrievals. In comparison with previously suggested approaches, the ratio method has the capability to increase the "harvest" of clear pixels. Similar to the traditional Independent Pixel Approximation (IPA), the ratio method has a low computational cost for retrieving AOD. In contrast to the IPA method, the ratio method provides much more accurate estimations of the AOD values under broken cloud conditions: pixel-based and domain-averaged estimations of errors in AOD are about 25% and 10%, respectively. Finally, both the ratio-based cloud screening and the accuracy of domain-averaged ratio-based AOD values do not suffer greatly when 5% random errors are introduced in the reflectances.

54 ENVIRONMENTAL SCIENCES↗

A MULTI-COLOR OPTICAL SURVEY OF THE ORION NEBULA CLUSTER. I. THE CATALOG

We present U, B, V, I broadband, 6200 A TiO mediumband, and H{alpha} narrowband photometry of the Orion Nebula Cluster (ONC) obtained with the WFI imager at the ESO/MPI 2.2 telescope at La Silla Observatory. The nearly simultaneous observations cover the entire ONC in a field of about 34 x 34 arcmin. They enable us to determine stellar colors avoiding the additional scatter in the photometry induced by stellar variability typical of pre-main-sequence stars. We identify 2612 point-like sources in the I band; 58%, 43%, and 17% of them are also detected in V, B, and U, respectively. 1040 sources are identified in the H{alpha} band. In this paper we present the observations, the calibration techniques adopted, and the resulting catalog. We show the derived color-magnitude diagram of the population and discuss the completeness of our photometry. We define a spectrophotometric TiO index that takes into account the fluxes in the V, I, and TiO bands. Comparing it with spectral types of ONC members in the literature, we find a correlation between the index and the spectral type valid for M-type stars, which is accurate to better than 1 spectral subclass for M3-M6 types and better than 2 spectral subclasses for M0-M2 types.. This allows us to newly classify 217 stars. In a similar way, we subtract from our H{alpha} photometry the photospheric continuum at its wavelength, deriving calibrated line excess for the full sample. This represents the largest H{alpha} star catalog obtained to date on the ONC. This data set enables a full re-analysis of the properties of the pre-main-sequence population in the Orion Nebula Cluster to be presented in an accompanying paper.

79 ASTRONOMY AND ASTROPHYSICS↗

The ZZ' kinetic mixing in the light of the recent direct and indirect dark matter searches

Several constructions, of stringy origins or not, generate abelian gauge extensions of the Standard Model (SM). Even if the particles of the SM are not charged under this extra U'(1), one cannot avoid the presence of a kinetic mixing between U'(1) and the hypercharge U{sub Y}(1). In this work, we constraint drastically this kinetic mixing, taking into account the recent experimental data from accelerator physics, direct detection and indirect detection of dark matter. We show that the region respecting WMAP and experimental constraints is now very narrowed along the pole line where M{sub Z{sub D}} ≅ 2m{sub DM}, Z{sub D} being the gauge boson associated to the extra U'(1)

79 ASTRONOMY AND ASTROPHYSICS↗

Optimizing Facility Operations by Applying Machine Learning to the Army Reserve Enterprise Building Control System (Final Report)

Thousands of U.S. Department of Defense (DoD) buildings have building automation systems (BASs) and/or advanced meters. Although these systems have a wealth of data, performance optimization requires time and expertise to review and act on that information. Machine learning (ML) can provide automated and actionable insights to controls operators. This demonstration implemented proven ML methods on the Army Reserve Enterprise Building Control System. ML refers to algorithms that “learn” from data and improve their performance on a given task over time. In the buildings domain these tasks range from predicting future energy consumption, to identifying operational issues before faults occur, to optimizing control decisions. To learn, ML requires input data, which – for buildings – typically consists of instrument data such as energy consumption data and subsystem controls information such as set-point temperatures, and context data consisting of information such as the physical location of the building, the area of the building, and the weather. ML models use the relationships learned from the input data to make predictions with new, previously unseen, data. The team was able to investigate and successfully implement the following ML use cases: labeling consumption data as anomalous or non-anomalous; baseline whole-building load prediction (unknown fault status); fault detection (validation not possible); and site prioritization for energy-related projects. Due to the constraints of the project, interventions were not able to be implemented during the demonstration; therefore, assessments of operational cost savings and maintenance avoided could not be performed. The project has been presented at two leading national building conferences and two additional publications to peer-reviewed journals are currently in preparation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

"Isotopics by nuclides" tool performance in InterSpec

This report provides a performance summary of the “Isotopics by Nuclides” tool in InterSpec. The primary objective of the NA-241 FY25 project was the detection and characterization of non-homogeneous uranium samples. However, the tool also demonstrates effectiveness in determining the enrichment of homogeneous uranium or plutonium from single gamma spectra. This paper presents a subset of evaluated data to avoid distribution limitations while offering potential users’ insight into the tool's performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Atomic‐Resolution Imaging of Halide Perovskites Using Electron Microscopy

Abstract Atomic‐resolution imaging of halide perovskites (HPs) using transmission electron microscopy (TEM) is challenging because of the sensitivity of their structures to the electron beam. In this article, recent achievements in this area are reviewed, covering both all‐inorganic and organic–inorganic hybrid HPs, with an emphasis on the specific imaging conditions that have proven to be effective in avoiding electron beam‐induced structural damage. The discussion focusses on the total electron dose that HPs can bear before being damaged and the effects of different imaging modes, accelerating voltages, and temperatures. The crucial role of a direct‐detection electron‐counting camera in reducing the required electron dose is outlined, which is indispensable for imaging extremely sensitive organic–inorganic hybrid perovskites. In addition to reviewing published works, the results of initial attempts to perform atomic‐resolution elemental mapping for an all‐inorganic HP and image a hybrid HP using scanning TEM are introduced. The preparation of a TEM specimen from macroscopic crystals or devices of HPs, which is very important for practical applications but has not yet received attention, is also discussed. This article aims to provide guidance on the acquisition of atomic‐resolution TEM images of HPs and inspire the development of more imaging technologies for sensitive materials.

Song, Kepeng↗

Human adipose-derived mesenchymal stromal cells from face and abdomen undergo replicative senescence and loss of genetic integrity after long-term culture

Body fat depots are heterogeneous concerning their embryonic origin, structure, exposure to environmental stressors, and availability. Thus, investigating adipose-derived mesenchymal stromal cells (ASCs) from different sources is essential to standardization for future therapies. In vitro amplification is also critical because it may predispose cell senescence and mutations, reducing regenerative properties and safety. Here, we evaluated long-term culture of human facial ASCs (fASCs) and abdominal ASCs (aASCs) and showed that both met the criteria for MSCs characterization but presented differences in their immunophenotypic profile, and differentiation and clonogenic potentials. The abdominal tissue yielded more ASCs, and these had higher proliferative potential, but facial cells displayed fewer mitotic errors at higher passages. However, both cell types reduced clonal efficiency over time and entered replicative senescence around P12, as evaluated by progressive morphological alterations, reduced proliferative capacity, and SA-β-galactosidase expression. Loss of genetic integrity was detected by a higher proportion of cells showing nuclear alterations and γ-H2AX expression. Our findings indicate that the source of ASCs can substantially influence their phenotype and therefore should be carefully considered in future cell therapies, avoiding, however, long-term culture to ensure genetic stability.

60 APPLIED LIFE SCIENCES↗

Localization and Quantification of Trace-gas Fugitive Emissions Using a Portable Optical Spectrometer

We present a portable optical spectrometer for fugitive emissions monitoring of methane (CH4). The sensor operation is based on tunable diode laser absorption spectroscopy (TDLAS), using a 5 cm open path design, and targets the 2ν3 R(4) CH4 transition at 6057.1 cm-1 (1651 nm) to avoid cross-talk with common interfering atmospheric constituents. Sensitivity analysis indicates a normalized precision of 2.0 ppmv∙Hz-1/2, corresponding to a noise-equivalent absorption (NEA) of 4.4×10-6 Hz-1/2 and minimum detectible absorption (MDA) coefficient of αmin = 8.8×10-7 cm-1∙Hz-1/2. Our TDLAS sensor is deployed at the Methane Emissions Technology Evaluation Center (METEC) at Colorado State University (CSU) for initial demonstration of single-sensor based source localization and quantification of CH4 fugitive emissions. The TDLAS sensor is concurrently deployed with a customized chemi-resistive metal-oxide (MOX) sensor for accuracy benchmarking, demonstrating good visual correlation of the concentration time-series. Initial angle-of-arrival (AOA) results will be shown, and development towards source magnitude estimation will be described.

03 NATURAL GAS↗