Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “depth”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

Integrating the PanDA Workload Management System with the Vera C. Rubin Observatory

The Vera C. Rubin Observatory will produce an unprecedented astronomical data set for studies of the deep and dynamic universe. Its Legacy Survey of Space and Time (LSST) will image the entire southern sky every three to four days and produce tens of petabytes of raw image data and associated calibration data over the course of the experiment’s run. More than 20 terabytes of data must be stored every night, and annual campaigns to reprocess the entire dataset since the beginning of the survey will be conducted over ten years. The Production and Distributed Analysis (PanDA) system was evaluated by the Rubin Observatory Data Management team and selected to serve the Observatory’s needs due to its demonstrated scalability and flexibility over the years, for its Directed Acyclic Graph (DAG) support, its support for multi-site processing, and its highly scalable complex workflows via the intelligent Data Delivery Service (iDDS). PanDA is also being evaluated for prompt processing where data must be processed within 60 seconds after image capture. This paper will briefly describe the Rubin Data Management system and its Data Facilities (DFs). Finally, it will describe in depth the work performed in order to integrate the PanDA system with the Rubin Observatory to be able to run the Rubin Science Pipelines using PanDA.

79 ASTRONOMY AND ASTROPHYSICS↗

Three-omega thermal-conductivity measurements with curved heater geometries

The three-omega method, a powerful technique to measure the thermal conductivity of nanometer-thick films and the interfaces between them, has historically employed straight conductive wires to act as both heaters and thermometers. When investigating stochastically prepared samples such as two-dimensional materials and nanomembranes, residue and excess material can make it difficult to fit the required millimeter-long straight wire on the sample surface. There are currently no available criteria for how diverting three-omega heater wires around obstacles affects the validity of the thermal measurement. In this Letter, we quantify the effect of the wire curvature by performing three-omega experiments with a wide range of frequencies using both curved and straight heater geometries on SiO 2 /Si samples. When the heating wire is curved, we find that the measured Si substrate thermal conductivity changes by only 0.2%. Similarly, we find that wire curvature has no significant effect on the determination of the thermal resistance of an ~65 nm SiO 2 layer, even for the sharpest corners considered here, for which the largest measured ratio of the thermal penetration depth of the applied thermal wave to radius of curvature of the heating wire is 4.3. This result provides useful design criteria for three-omega experiments by setting a lower bound for the maximum ratio of the thermal penetration depth to wire radius of curvature.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Magnetic reconnection and kinetic waves generated in the Earth's quasi-parallel bow shock

Magnetic reconnection in quasi-parallel shocks, relevant to the Earth’s bow shock, is studied by means of two-dimensional full particle-in-cell simulations. As the Alfvénic Mach number increases, the propagation direction of the waves excited in the transition region changes, and the shock becomes more turbulent with more reconnection sites. In the higher Mach number shock, abundant electron-only reconnection sites are generated with scales on the order of the ion skin depth or less. Non-reconnecting current sheets can also generate electron jets and energy dissipation can occur there as well. However, non-reconnecting current sheets with the magnetic field reversal typically show a smaller energy dissipation rate than reconnecting current sheets. In the shock transition region, two types of waves are responsible for driving reconnection: one has a wavelength around three ion skin depths (d i ), and the other has a wavelength less than 1 d i . Here, electron and ion distribution functions show that in regions where the former type of waves is excited, there are two ion beams and a single-peaked electron distribution. In contrast, in regions where the latter type of waves is excited, there are multiple electron and ion beams. The waves propagating obliquely to the magnetic field bend the magnetic field lines, and magnetic reconnection occurs where oppositely directed field lines come into contact.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Defect suppression in wet-treated etched-and-regrown nonpolar m-plane GaN vertical Schottky diodes: A deep-level optical spectroscopy analysis

In this work, steady-state photocapacitance (SSPC) was conducted on nonpolar m-plane GaN n-type Schottky diodes to evaluate the defects induced by inductively coupled plasma (ICP) dry etching in etched-and-regrown unipolar structures. An ~10× increase in the near-midgap Ec – 1.9 eV level compared to an as-grown material was observed. Defect levels associated with regrowth without an etch were also investigated. The defects in the regrown structure (without an etch) are highly spatially localized to the regrowth interface. Subsequently, by depth profiling an etched-and-regrown sample, we show that the intensities of the defect-related SSPC features associated with dry etching depend strongly on the depth away from the regrowth interface, which is also reported previously. A photoelectrochemical etching (PEC) method and a wet AZ400K treatment are also introduced to reduce the etch-induced deep levels. A significant reduction in the density of deep levels is observed in the sample that was treated with PEC etching after dry etching and prior to regrowth. An ~2× reduction in the density of Ec – 1.9 eV level compared to a reference etched-and-regrown structure was observed upon the application of PEC etching treatment prior to the regrowth. The PEC etching method is promising for reducing defects in selective-area doping for vertical power switching structures with complex geometries.

36 MATERIALS SCIENCE↗

Experiments and simulations of isochorically heated warm dense carbon foam at the Texas Petawatt Laser

An experimental and simulation study of warm dense carbon foams at ambient density (n e ~10 21 cm –3 ) is presented. This study of isochorically heated foams is motivated by their potential application in carbon-atmosphere white-dwarf envelopes, where there are modeling uncertainties due to the equation of state. The foams are heated on an approximately picosecond time scale with a laser-accelerated proton beam. The cooling and expansion of the heated foams can be modeled with appropriately initialized radiation-hydrodynamics codes; xRAGE code is used in this work. The primary experimental diagnostic is the streaked optical pyrometer, which images a narrow band of radiation from the rear surface of the heated material. Presented are xRAGE modeling results for both solid aluminum targets and carbonized resorcinol-formaldehyde foam targets, showing that the foam appears to cool slowly on the pyrometer because of partial transparency. So that simulations of cooling foam are processed properly, it is necessary to account for finite optical depth in the photosphere calculation, and the methods for performing that calculation are presented in depth.

36 MATERIALS SCIENCE↗

Probing thermal conductivity of subsurface, amorphous layers in irradiated diamond

In this study, we report on the thermal conductivity of amorphous carbon generated in diamond via nitrogen ion implantation (N 3+ at 16.5 MeV). Here, transmission electron microscopy techniques demonstrate amorphous band formation about the longitudinal projected range, localized approximately 7 μm beneath the sample surface. While high-frequency time-domain thermoreflectance measurements provide insight into the thermal properties of the near-surface preceding the longitudinal projected range depth, a complimentary technique, steady-state thermoreflectance, is used to probe the thermal conductivity at depths which could not otherwise be resolved. Through measurements with a series of focusing objective lenses for the laser spot size, we find the thermal conductivity of the amorphous region to be approximately 1.4 W m –1 K –1 , which is comparable to that measured for amorphous carbon films fabricated through other techniques.

36 MATERIALS SCIENCE↗

Detrimental effects and mitigation of the joint feature in double shell implosion simulations

Double shell capsules provide an attractive option in inertial confinement fusion experiments due to their potential for achieving a low-convergence, robust burn. However, these designs suffer from symmetry degradation and accompanying reduced fuel confinement due to the currently necessary joint between the two hemispheres of the outer shell. Here, the gap widens as a result of the excess ablation pressure produced by x rays that penetrate the joint during the drive phase, and this perturbation grows and imprints onto the inner shell during the collision. xRAGE Eulerian radiation-hydrodynamic simulations predict significant reductions in deuterium–tritium fusion yields compared to joint-less simulations when the depth of the outer joint is increased, whereas the performance is less sensitive to the depth of the inner gap. Here we examine the technique of plating the insides of the outer gap with a high-Z material to mitigate the impact of this feature. Gold-plating in quantities comparable to or exceeding the “missing” outer shell mass shows promise toward restoring both implosion symmetry and yield closer to the joint-less levels, and synthetic diagnostics suggest that high-energy x-ray radiographs can capture this shape retention of the inner and outer shells in experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dynamic thermal behavior of polycrystalline LaB 6 hollow cathodes

Lanthanum hexaboride (LaB6) hollow cathodes have demonstrated a capability for long life operation, which is critical to many space exploration missions. Thermal characterization of LaB6 hollow cathodes has revealed lower than expected electron emitter temperatures when the cathode reaches a steady state. This phenomenon is observed at discharge currents ranging from 5 to 35 A and xenon mass flow rates of 5–25 SCCM in cathodes with three different orifice diameters. Thus, the currently accepted value of the work function for polycrystalline LaB 6 , 2.67 eV, does not describe well the emission characteristics of LaB6 hollow cathodes operating with internal gas discharges at a steady state. We use empirically measured temperatures combined with a model of the hollow cathode emitter and xenon discharge to estimate the value of the work function, yielding a value ranging from 2.1 to 2.44 eV. This lower work function value implies that LaB6 hollow cathodes are expected to have even longer lifetimes than previously anticipated, further establishing them as a more suited alternative to other conventional cathode technologies for the task of long duration travel. Direct measurements of the work function as a function of depth on a hollow cathode emitter using x-ray photoelectron spectroscopy and ion beam milling indicate that the work function decreases with depth. We postulate several mechanisms that could explain the observed work function enhancement. Altogether, our results have important implications to the design, study approach, and operation of LaB 6 cathodes and potentially other cathodes with hollow configuration. Finally, our work opens the question of why the work function is reduced upon interaction with Xe plasma.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A simple numerical method for evaluating heat dissipation from curved wires with periodic applied heating

In many situations, the dual-purpose heater/thermometer wires used in the three-omega method – one of the most precise and sensitive techniques for measuring the thermal conductivity of thin films and interfaces – must include bends and curves to avoid obstructions on the surface of a sample. Although the three-omega analysis assumes that the heating wire is infinitely long and straight, recent experimental work has demonstrated that in some cases curved-wire geometries can be used without introducing detectable systematic error. We describe a general numerical method that can be used to calculate the temperature of three-omega heating wires with arbitrary wire geometries. Furthermore, this method provides experimentalists with a simple quantitative procedure for calculating how large the systematic error caused by a particular wire asymmetry will be. We show calculations of two useful cases: a straight wire with a single bend of arbitrary angle and a wire that forms a circle. We find that the amplitude of the in-phase temperature oscillations near a wire that forms a circle differs from the prediction using the analytic straight-line source solution by <12%, provided that the thermal penetration depth is less than ten times the radius of curvature of the wire path. The in-phase temperature amplitude 1.5 wire widths away from a 90° bend in a wire is within 11% of the straight-line source prediction for all penetration depths greater than the wire width. Our calculations indicate that the straight-line source solution breaks down significantly when the wire bend angle is less than 45°.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Realizing crack-free high-aluminum-mole-fraction AlGaN on patterned GaN beyond the critical layer thickness

Wide-bandgap III-nitride heterostructures are required for a variety of device applications. However, this alloy system has a large lattice constant and thermal expansion coefficient mismatch that limits the alloy composition and layer thickness for many heteroepitaxial device structures. Consequently, various methods have been devised to allow the heteroepitaxial growth of AlInGaN heterostructures to accommodate this inherent strain. In this work, we describe a non-planar-growth approach that enables the deposition of crack-free high-Al-mole-fraction Al x Ga 1-x N on patterned GaN/sapphire templates and bulk GaN substrates with large-area mesas. We have studied the effects of the patterned mesa width, the mesa etch depth, and the gap between the mesas on the heteroepitaxy of Al x Ga 1-x N superlattices with an average Al molar fraction 0.11 < x¯ < 0.21 and non-planar overgrowth growth thicknesses up to 3.5 μm. Similar to the planar growth approach, increasing the thickness and Al mole fraction of the Al x Ga 1-x N superlattices leads to surface cracking when exceeding the critical layer thickness. However, limiting the mesa dimension in one direction enables strain mitigation and drastically increases the critical layer thickness. Additionally, larger etch depths of the mesas increase the Al alloy composition and thickness for crack-free AlGaN heteroepitaxy whereas the gap in between the mesas seems to have no crucial influence. We demonstrate that the Al alloy composition and layer thicknesses of such heterostructures can be increased far beyond the critical layer thickness for planar growth and demonstrate the growth of a crack-free full AlxGa 1-x N/GaN quantum-well laser heterostructure designed for operation at ~370 nm.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The mechanism behind the high radiation tolerance of Fe-Cr alloys

With the great demand for high radiation tolerant materials for advanced nuclear energy technologies, Fe-Cr alloys are at the forefront with long standing validated performance. Yet, the real mechanism behind their high radiation resistance is in question and understanding the effect of varying Cr percentage is a grand challenge limiting further improvements. Here we applied depth resolved atomic scale probe of defects to uncover the real mechanism on how Cr improves radiation resistance and explain the controversial impact of increasing Cr percentage. By combining depth-resolved positron annihilation lifetime spectroscopy and Doppler broadening spectroscopy we investigated the effect of Cr alloying on the formation and evolution of atomic size clusters induced by ion irradiation in Fe. We also used atom probe tomography to investigate the possible presence of Cr clusters or a’ phase with high Cr composition. The study reveals that the well-known resistance to radiation in Fe-Cr alloys arises from the stabilization of vacancy clusters around Cr atoms which act as sinks for radiation-induced defects. Thus, Cr atoms do not provide a direct sink for interstitials; rather defect complexes for that consist of Cr atoms and vacancies in turn act as sinks for irradiation-induced vacancies and interstitials. Most importantly, we find that lower amounts of Cr create smaller, uniformly distributed defect clusters that act as efficient sinks for radiation damage, but larger quantities of Cr form a defect structure that is less homogenous in size and spatial distribution, resulting in less efficient damage recombination. No evidence of phase a’ was found before or after irradiation, which indicates that it does not contribute to the observed radiation tolerance.

36 MATERIALS SCIENCE↗

Effect of thermal oxidation on helium implanted 316L stainless steel

The effect of thermal oxide layer on He implanted 316L stainless steel was studied to evaluate experimentally how thermal oxidation affects the diffusion and distribution of He in the material. In the case of thermal oxidation of a He implanted sample, with an increase in oxidation time, the max swelling height increases logarithmically as a function of time and finally saturates for all samples except for the lowest dose of implanted He. Concerning TEM results, two void regions are identified. Similar to the calculation, the total irradiated depth was around 250 nm and the large void region was formed around 100–150 nm depth. On the other hand, the small void region was observed immediately under oxide layer from the thermal oxidation. In contrast, there were no voids in the altered zone near the metal/oxide interface in the non-thermal oxidized/He implanted sample. This description of the phenomena was justified using the Kirkendall effect and the Point Defect Model.

36 MATERIALS SCIENCE↗

Two-dimensional spin systems in PECVD-grown diamond with tunable density and long coherence for enhanced quantum sensing and simulation

Systems of spins engineered with tunable density and reduced dimensionality enable a number of advancements in quantum sensing and simulation. Defects in diamond, such as nitrogen-vacancy (NV) centers and substitutional nitrogen (P1 centers), are particularly promising solid-state platforms to explore. However, the ability to controllably create coherent, two-dimensional spin systems and characterize their properties, such as density, depth confinement, and coherence, is an outstanding materials challenge. We present a refined approach to engineer dense (≳1 ppm ∙ nm), 2D nitrogen, and NV layers in diamond using delta-doping during plasma-enhanced chemical vapor deposition epitaxial growth. We employ both traditional materials techniques, e.g., secondary ion mass spectrometry, alongside NV spin decoherence-based measurements to characterize the density and dimensionality of the P1 and NV layers. We find P1 densities of 5–10 ppm ∙ nm, NV densities between 1 and 3.5 ppm ∙ nm tuned via electron irradiation dosage, and depth confinement of the spin layer down to 1.6 nm. We also observe high (up to 0.74) ratios of NV to P1 centers and reproducibly long NV coherence times, dominated by dipolar interactions with the engineered P1 and NV spin baths.

36 MATERIALS SCIENCE↗

Laser material interactions in tamped materials on picosecond time scales in aluminum

Here, a 100 ps laser is used to probe the pressure generation, depth of the non-solid ablator, and the non-linear optical effects through tamper materials. Samples consisted of an aluminum ablator with tampers of sapphire and coverslip glass. In general, the sapphire tamped sample achieves higher pressures at lower laser intensities as compared to the coverslip glass tamped sample. Attempts to model the details of this set of experimental data with standard available radiation coupled hydrodynamic codes make clear that more physics is needed in these simulations to accurately predict the impact of the tamper material on the pressure generation and the depth of non-solid aluminum.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Analytical model for laser-induced transient grating measurements of thermal diffusivity in non-opaque materials

The thermal transport and elastic properties of materials are often measured using the laser-induced transient grating spectroscopy (TGS) technique. The analysis of the TGS signal usually involves fitting well-known expressions, derived assuming the limiting cases of opaque or transparent materials, to the measured data. In this paper, the system of thermoelastic equations is analytically solved for an isotropic homogeneous material assuming finite laser penetration depth, which is an important consideration when the penetration depth is on the order of the acoustic wavelength. The need to use such a solution is discussed and compared to the expression for opaque material. The solution is benchmarked against TGS signal measured on single-crystal silicon with {100} surface orientation and is found to significantly improve the accuracy of the calculated thermal diffusivity as compared to using the expression for opaque material.

36 MATERIALS SCIENCE↗

Temperature effects on the nanoscale thermoelastic response of a SiO2 membrane

We crossed two femtosecond extreme ultraviolet (EUV) pulses on a 100 nm thick amorphous membrane of SiO2, generating transient gratings (TGs) of light intensity with 84 nm spatial periodicity. The EUV TG excitation gave rise to the efficient generation of Lamb waves (LWs) and of a temperature grating, whose dynamics was studied at two different initial sample temperatures, 50 and 300 K. The short penetration depth of the EUV excitation pulses turned into a strong non-uniformity in the actual temperature as a function of the depth from the sample surface. At the lowest temperature, the LW frequencies presented a sizable shift in time due to the thermal equilibration along the membrane thickness. The analysis of the EUV TG waveforms allowed us to determine the decay time of the thermal grating and the sound attenuation coefficient, both found in reasonable agreement with the literature. The results show how EUV TG can provide information of non-equilibrium thermoelastic dynamics in thin membranes transparent to optical radiation.

Materials Science↗

Experiments and gyrokinetic simulations of the nonlinear interaction between spinning magnetized plasma pressure filaments

A set of experiments using controlled, skin depth-sized plasma pressure filaments in close proximity have been carried out in a large linear magnetized plasma device. Two- and three-filament configurations have been used to determine the scale of cross field nonlinear interaction. When the filaments are separated by a distance of approximately five times the size of a single filament or less, a significant transfer of charge and energy occurs, leading to the generation of inter-filament electric fields. This has the effect of rotating the filaments and influencing the merging dynamics. Nonlinear gyrokinetic simulations using seeded filaments confirm the presence of unstable drift-Alfvén modes driven by the steep electron temperature gradient. When the filaments are within a few collisionless electron skin depths (separations twice the size of a single filament), the unstable perturbations drive the convective mixing of the density and temperature and rearrange the gradients such that they maximize in the region surrounding the filament bundle.

Sydora, R. D. (ORCID:0000000192543149)↗

Development and characterization of a laser-gated, high resolution x-ray radiography platform for high energy density experiments using toroidally bent crystals

Bent crystal x-ray imagers are a well-established diagnostic tool to study high energy density (HED) objects by acquiring two-dimensional x-ray radiographs. Often, studying these HED objects requires very high spatial resolution, which is limited by astigmatism when using spherically bent crystals. By using toroidal-shaped crystals instead, astigmatism can be reduced and the overall spatial resolution of the instrument improved. Here, the development and characterization of a laser-gated x-ray radiography platform at the National Ignition Facility using a toroidal crystal is presented. This includes measurements of the spatial and temporal profile, which is determined by the x-ray source. In conclusion, to properly validate the reduced astigmatism, a new multi-plane grid approach was implemented, which, for the first time, allows a depth of field measurement, alignment verification and x-ray source size estimate in a single shot, demonstrating the current platform’s capability to provide sub-10 μm resolution over a 0.9 mm depth of field with a temporal resolution of 110 ps.

Crystal optics↗