The Cryogenic Underground Observatory for Rare Events: Status and Prospects

The Cryogenic Underground Observatory for Rare Events (CUORE) is a large-scale double beta decay experiment utilizing cryogenic bolometers that is currently being commissioned at the Gran Sasso National Laboratory (LNGS) in Italy. Its primary focus is to search for the neutrino-less double beta decay of 130Te with a projected sensitivity to Majorana neutrino masses near the inverted mass hierarchy region. The detector is composed of 988 5x5x5-cm 3 TeO 2 crystals of natural isotopic composition arranged in 19 towers of 52 crystals each, all housed in a common dilution refrigerator. A single CUORE-like tower, CUORE-0, was assembled and operated as a stand-alone detector for a period of approximately two years. In this report, the results from CUORE-0 and the current status and physics potential of CUORE are presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Cryogenic Instrumentation at ProtoDUNE

The cryogenic instrumentation of ProtoDUNE successfully operated during the first run of the experiment, providing a comprehensive monitoring of the cryostats, the cryogenics system and the detectors. It includes devices to measure the liquid argon level, the electron lifetime, the temperature of the liquid and gas argon, the pressure inside the cryostat and the contamination of the gas argon, as well as cameras to inspect the most critical detector elements. These systems and their performance are reviewed, and a few aspects of their future upgrade discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improving Cathode Testing with a High-Gradient Cryogenic Normal Conducting RF Photogun

Future electron accelerator applications such as X-ray free electron lasers and colliders are dependent on significantly increasing beam brightness. With the observation that linac beam manipulation’s best preservation of max brightness is at the cathode, we are incentivized to create an environment where we can study how to achieve the highest possible photogun brightness. In order to do so, we intend to extract beams from high-brightness photocathodes with the highest achievable accelerating gradients we can manage in a klystron-powered radiofrequency (RF) photogun. We utilize here cryogenic normal conducting cavities to achieve ultra-high gradients via limitation of breakdown rates (BDR). The low temperatures should also reduce cathode emittance by reducing the mean transverse energy (MTE) of electrons near the photoemission threshold. To this end, we have designed and produced a new CrYogenic Brightness-Optimized Radiofrequency Gun (CYBORG) for use in a new beamline at UCLA. We will introduce the enabling RF and photoemission physics as a primer for the new regime of high field low temperature cathodes we intend to enter. We further report the current status of the beamline commissioning, including the cooling of the photogun to 100 K, and producing 0.5 MW of RF feed power, which corresponds to cathode accelerating fields in the range of 80–90 MV/m. We further plan iterative improvements to both to 77 K and 1 MW corresponding to our ultimate goal >120 MV/m. Our discussion will include future beamline tests and the consideration of the initial realization of an ultra-high-gradient photoinjector concept.

Lawler, Gerard Emile (ORCID:0000000160113435)↗

Investigating Helium Bubble Nucleation and Growth through Simultaneous In-Situ Cryogenic, Ion Implantation, and Environmental Transmission Electron Microscopy

Palladium can readily dissociate molecular hydrogen at its surface, and rapidly accept it onto the octahedral sites of its face-centered cubic crystal structure. This can include radioactive tritium. As tritium β-decays with a half-life of 12.3 years, He-3 is generated in the metal lattice, causing significant degradation of the material. Helium bubble evolution at high concentrations can result in blister formation or exfoliation and must therefore be well understood to predict the longevity of materials that absorb tritium. A hydrogen over-pressure must be applied to palladium hydride to prevent hydrogen from desorbing from the metal, making it difficult to study tritium in palladium by methods that involve vacuum, such as electron microscopy. Recent improvements in in-situ ion implantation Transmission Electron Microscopy (TEM) allow for the direct observation of He bubble nucleation and growth in materials. In this work, we present results from preliminary experiments using the new ion implantation Environmental TEM (ETEM) at the University of Huddersfield to observe He bubble nucleation and growth, in-situ, in palladium at cryogenic temperatures in a hydrogen environment. After the initial nucleation phase, bubble diameter remained constant throughout the implantation, but bubble density increased with implantation time. β-phase palladium hydride was not observed to form during the experiments, likely indicating that the cryogenic implantation temperature played a dominating role in the bubble nucleation and growth behavior.

36 MATERIALS SCIENCE↗

Cryogenic testing of the 2.1 GHz five-cell superconducting RF cavity with a photonic band gap coupler cell

We present results from cryogenic tests of the multi-cell superconducting radio frequency (SRF) cavity with a photonic band gap (PBG) coupler cell. Achieving high average beam currents is particularly desirable for future light sources and particle colliders based on SRF energy-recovery-linacs (ERLs). Beam current in ERLs is limited by the beam break-up instability, caused by parasitic higher order modes (HOMs) interacting with the beam in accelerating cavities. A PBG cell incorporated in an accelerating cavity can reduce the negative effect of HOMs by providing a frequency selective damping mechanism, thus allowing significantly higher beam currents. The multi-cell cavity was designed and fabricated of niobium. Two cryogenic (vertical) tests were conducted. The high unloaded Q-factor was demonstrated at a temperature of 4.2 K at accelerating gradients up to 3 MV/m. The measured value of the unloaded Q-factor was 1.55 × 10<8>, in agreement with prediction.

43 PARTICLE ACCELERATORS↗

Feed-thru flange is useful in vacuum applications to cryogenic temperatures

Feed-thru flange seals inner and outer walls of high vacuum test chambers. It is used in vacuum applications at both cryogenic and higher than cryogenic temperatures. A damaged flange can still be used for partial vacuum, noncryogenic applications in conjunction with an appropriate rubber seal.

Yager, S. P.↗

Concept for cryogenic liquid reclamation system

Cryogenic liquid reclamation system is used as an add-on unit to the nitrogen system of environmental test laboratories to salvage liquid nitrogen presently being treated as waste. The system may be installed indoors or outdoors provided the gas boiled off from the cryogenic liquid is vented to the outside.

Daderian, S. M.↗

Handbook of cryogenic data in graphic form

Handbook of Cryogenic Data is written in graphic form and concentrates extensive data on common materials of construction and properties of fluids frequently encountered in designing cryogenic systems. All data are presented in the British system of units.

Loeb, M. B.↗

Cryogenic seal concept for static and dynamic conditions

Seal rings reduce cryogenic pump seal leakage under static and dynamic conditions. The rings are fitted into annular diaphragms, which are affected by cryogenic pressure and temperature, to move against a mating ring, to increase seal-bearing loads under static conditions.

De Gaetano, E. A.↗

A study of cryogenic container thermodynamics during propellant transfer. Volume 2 - Final engineering report

This report describes the results of a study of cryogenic container thermodynamics during propellant transfer. The purpose of this study is to provide analytical and empirical descriptions of the transient phenomena occurring in cryogenic transfer lines and receive tanks during initial propellant transfer. A further basic objective is to identify those conditions which give rise to the possibility of tank implosion, and to establish the procedures and/or systems necessary to eliminate this possibility.

R M Vernon↗

Control for maintaining constant level of a cryogenic liquid

Pressure formed as the cryogenic liquid vaporizes is used to pump new cryogenic liquid from a storage reservoir. Changes in volume of a gas resulting from changes in temperature actuate a valve which either replenishes the depleted liquid in the vessel or vents the evolving gas to the atmosphere.

Liberotti, J.↗

Cryogenic pressure transducer

Cryogenic pressure transducer utilizes a diaphragm which is electron beam welded to a fitting. This assembly is then heliarc welded to the main body of the transducer. The transducer requires no damping oil and thus is capable of operating at both cryogenic and high temperatures.

Hendrix, J. M.↗