Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “coverage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

Comparison of Methods to Reduce Dose to Swallowing-Related Structures in Head and Neck Cancer

Introduction: Emerging data suggest that reduction of dose to the larynx and pharyngeal constrictor may lower the risk of swallowing complications such as long-term gastrostomy dependence and aspiration. Organ avoidance becomes difficult when the primary tumor or involved nodes are present at the level of the larynx. Materials and Methods: Fifteen patients with Stage III-IV squamous cell carcinoma of the head and neck with high-dose target volume at the level of the larynx (but not involving the glottic larynx) were planned with whole-field IMRT (WF-IMRT), as well as a low anterior neck field dynamically matched to an IMRT plan (D-SCLV). Plans were compared with respect to coverage of targets and sparing of normal tissues including the larynx, inferior pharyngeal constrictor (IPC), parotid, and cord. Results: There was no significant difference between the two techniques in coverage of the high- or intermediate-dose planning target volumes (PTVs). Coverage of the elective nodal PTV was inferior with the D-SCLV technique, with a mean of 96.5% vs. 86.3% of the volume receiving the prescription dose (p = 0.001) compared with WF-IMRT plans. However, the D-SCLV technique significantly reduced mean dose to the larynx (43.7 vs. 46.7 Gy, p = 0.05) and IPC (39.1 vs. 46.1 Gy, p = 0.002). There was no significant difference in dose to the parotid or cord. Conclusion: Given the steep dose responses seen in studies examining the association between swallowing toxicity and dose to the larynx and IPC, dose reductions using the D-SCLV technique may be clinically significant.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Value of Combined PET/CT for Radiation Planning in CT-Guided Percutaneous Interstitial High-Dose-Rate Single-Fraction Brachytherapy for Colorectal Liver Metastases

Purpose: To determine the additional value of fluorodeoxyglucose-positron emission tomography (PET) for clinical target volume definition in the planning of computed tomography (CT)-guided interstitial brachytherapy for liver metastases. Patients and Methods: A total of 19 patients with liver metastases from colorectal cancer treated in 25 sessions were included in the present study. All patients had undergone fluorodeoxyglucose-PET for patient evaluation before interstitial CT-guided brachytherapy. A contrast-enhanced CT scan of the upper abdomen was obtained for radiation planning. The clinical target volume (CTV) was defined by a radiation oncologist and radiologist. After registration of the CT scan with the PET data set, the target volume was defined again using the fusion images. Results: PET revealed one additional liver lesion that was not visible on CT. The median CT-CTV (defined using CT and magnetic resonance imaging) was 68 cm{sup 3} (range 4-260). The PET/CT-CTV (median, 78 cm{sup 3}; range, 4-273) was significantly larger, with a median gain of 24.5% (interquartile range, 2.1-71.5%; p = .022). An increased CTV was observed in 15 cases and a decrease in 6; in 4 cases, the CT-CTV and PET/CT-CTV were equal. Incomplete dose coverage of PET/CT-CTVs was indicative of early local progression (p = .004); however, CT-based radiation plans did not show significant differences in the local control rates when stratified by dose coverage. Conclusion: Retrospective implementation of fluorodeoxyglucose-PET for CTV specification for CT-guided brachytherapy for colorectal liver metastases revealed a significant change in the CTVs. Additional PET-positive tumor regions with incomplete dose coverage could explain unexpected early local progression.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Automated Weekly Replanning for Intensity-Modulated Radiotherapy of Cervix Cancer

Purpose: The adoption of intensity-modulated radiotherapy (IMRT) to treat cervical malignancies has been limited in part by complex organ and tumor motion during treatment. This study explores the limits of a highly adaptive, small-margin treatment scenario to accommodate this motion. In addition, the dosimetric consequences of organ and tumor motion are modeled using a combination of deformable registration and fractional dose accumulation techniques. Methods and Materials: Thirty-three cervix cancer patients had target volumes and organs-at-risk contoured on fused, pretreatment magnetic resonance-computed tomography images and weekly magnetic resonance scans taken during treatment. The dosimetric impact of interfraction organ and target motion was compared for two hypothetical treatment scenarios: a 3-mm margin plan with no replanning, and a 3-mm margin plan with an automated replan performed on the updated weekly patient geometry. Results: Of the 33 patients, 24 (73%) met clinically acceptable target coverage (98% of the clinical target volume receiving at least 95% of the prescription dose) using the 3-mm margin plan without replanning. The range in dose to 98% of the clinical target volume across all patients was 7.9% of the prescription dose if no replanning was performed. After weekly replanning, this range was tightened to 2.6% of the prescription dose and all patients met clinically acceptable target coverage while maintaining organ-at-risk dose sparing. Conclusions: The dosimetric impact of anatomical motion underscores the challenges of applying IMRT to treat cervix cancer. An appropriate adaptive strategy can ensure target coverage for small-margin IMRT treatments and maintain favorable organ-at-risk dose sparing.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Proton Therapy for Malignant Pleural Mesothelioma After Extrapleural Pleuropneumonectomy

Purpose: To perform comparative planning for intensity-modulated radiotherapy (IMRT) and proton therapy (PT) for malignant pleural mesothelioma after radical surgery. Methods and Materials: Eight patients treated with IMRT after extrapleural pleuropneumonectomy (EPP) were replanned for PT, comparing dose homogeneity, target volume coverage, and mean and maximal dose to organs at risk. Feasibility of PT was evaluated regarding the dose distribution with respect to air cavities after EPP. Results: Dose coverage and dose homogeneity of the planning target volume (PTV) were significantly better for PT than for IMRT regarding the volume covered by >95% (V95) for the high-dose PTV. The mean dose to the contralateral kidney, ipsilateral kidney, contralateral lung, liver, and heart and spinal cord dose were significantly reduced with PT compared with IMRT. After EPP, air cavities were common (range, 0-850 cm{sup 3}), decreasing from 0 to 18.5 cm{sup 3}/day. In 2 patients, air cavity changes during RT decreased the generalized equivalent uniform dose (gEUD) in the case of using an a value of < - 10 to the PTV2 to <2 Gy in the presence of changing cavities for PT, and to 40 Gy for IMRT. Small changes were observed for gEUD of PTV1 because PTV1 was reached by the beams before air. Conclusion: Both PT and IMRT achieved good target coverage and dose homogeneity. Proton therapy accomplished additional dose sparing of most organs at risk compared with IMRT. Proton therapy dose distributions were more susceptible to changing air cavities, emphasizing the need for adaptive RT and replanning.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effects of Setup Errors and Shape Changes on Breast Radiotherapy

Purpose: The purpose of the present study was to quantify the robustness of the dose distributions from three whole-breast radiotherapy (RT) techniques involving different levels of intensity modulation against whole patient setup inaccuracies and breast shape changes. Methods and Materials: For 19 patients (one computed tomography scan and five cone beam computed tomography scans each), three treatment plans were made (wedge, simple intensity-modulated RT [IMRT], and full IMRT). For each treatment plan, four dose distributions were calculated. The first dose distribution was the original plan. The other three included the effects of patient setup errors (rigid displacement of the bony anatomy) or breast errors (e.g., rotations and shape changes of the breast with respect to the bony anatomy), or both, and were obtained through deformable image registration and dose accumulation. Subsequently, the effects of the plan type and error sources on target volume coverage, mean lung dose, and excess dose were determined. Results: Systematic errors of 1-2 mm and random errors of 2-3 mm (standard deviation) were observed for both patient- and breast-related errors. Planning techniques involving glancing fields (wedge and simple IMRT) were primarily affected by patient errors ({approx}6% loss of coverage near the dorsal field edge and {approx}2% near the skin). In contrast, plan deterioration due to breast errors was primarily observed in planning techniques without glancing fields (full IMRT, {approx}2% loss of coverage near the dorsal field edge and {approx}4% near the skin). Conclusion: The influences of patient and breast errors on the dose distributions are comparable in magnitude for whole breast RT plans, including glancing open fields, rendering simple IMRT the preferred technique. Dose distributions from planning techniques without glancing open fields were more seriously affected by shape changes of the breast, demanding specific attention in partial breast planning techniques.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dosimetric Comparison of Three-Dimensional Conformal Proton Radiotherapy, Intensity-Modulated Proton Therapy, and Intensity-Modulated Radiotherapy for Treatment of Pediatric Craniopharyngiomas

Purpose: Cranial irradiation in pediatric patients is associated with serious long-term adverse effects. We sought to determine whether both three-dimensional conformal proton radiotherapy (3D-PRT) and intensity-modulated proton therapy (IMPT) compared with intensity-modulated radiotherapy (IMRT) decrease integral dose to brain areas known to harbor neuronal stem cells, major blood vessels, and other normal brain structures for pediatric patients with craniopharyngiomas. Methods and Materials: IMRT, forward planned, passive scattering proton, and IMPT plans were generated and optimized for 10 pediatric patients. The dose was 50.4 Gy (or cobalt Gy equivalent) delivered in 28 fractions with the requirement for planning target volume (PTV) coverage of 95% or better. Integral dose data were calculated from differential dose-volume histograms. Results: The PTV target coverage was adequate for all modalities. IMRT and IMPT yielded the most conformal plans in comparison to 3D-PRT. Compared with IMRT, 3D-PRT and IMPT plans had a relative reduction of integral dose to the hippocampus (3D-PRT, 20.4; IMPT, 51.3%{sup Asterisk-Operator }), dentate gyrus (27.3, 75.0%{sup Asterisk-Operator }), and subventricular zone (4.5, 57.8%{sup Asterisk-Operator }). Vascular organs at risk also had reduced integral dose with the use of proton therapy (anterior cerebral arteries, 33.3{sup Asterisk-Operator }, 100.0%{sup Asterisk-Operator }; middle cerebral arteries, 25.9%{sup Asterisk-Operator }, 100%{sup Asterisk-Operator }; anterior communicating arteries, 30.8{sup Asterisk-Operator }, 41.7%{sup Asterisk-Operator }; and carotid arteries, 51.5{sup Asterisk-Operator }, 77.6{sup Asterisk-Operator }). Relative reduction of integral dose to the infratentorial brain (190.7{sup Asterisk-Operator }, 109.7%{sup Asterisk-Operator }), supratentorial brain without PTV (9.6, 26.8%{sup Asterisk-Operator }), brainstem (45.6, 22.4%{sup Asterisk-Operator }), and whole brain without PTV (19.4{sup Asterisk-Operator }, 34.4%{sup Asterisk-Operator }) were recorded with the use of proton therapy. ({sup Asterisk-Operator }Differences were significant based on Friedman's test with Bonferroni-Dunn correction, {alpha} = 0.05) Conclusions: The current study found that proton therapy was able to avoid excess integral radiation dose to a variety of normal structures at all dose levels while maintaining equal target coverage. Future studies will examine the clinical benefits of these dosimetric advantages.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effect of Radiotherapy Techniques (IMRT vs. 3D-CRT) on Outcome in Patients With Intermediate-Risk Rhabdomyosarcoma Enrolled in COG D9803-A Report From the Children's Oncology Group

Purpose: To compare the dosimetric parameters of intensity-modulated radiotherapy (IMRT) and three-dimensional conformal radiotherapy (3D-CRT) in patients with intermediate-risk rhabdomyosarcoma and to analyze their effect on locoregional control and failure-free survival (FFS). Methods and Materials: The study population consisted of 375 patients enrolled in the Children's Oncology Group protocol D9803 study, receiving IMRT or 3D-CRT. Dosimetric data were collected from 179 patients with an available composite plan. The chi-square test or Fisher's exact test was used to compare the patient characteristics and radiotherapy parameters between the two groups. The interval-to-event outcomes were estimated using the Kaplan-Meier method and compared using log-rank tests. Cox proportional hazards regression analysis was used to examine the effect of the treatment technique on FFS after adjusting for primary site and risk group. Results: The median follow-up time was 5.7 and 4.2 years for patients receiving 3D-CRT and IMRT, respectively. No differences in the 5-year failure of locoregional control (18% vs. 15%) or FFS (72% vs. 76%) rates were noted between the two groups. Multivariate analysis revealed no association between the two techniques and FFS. Patients with primary tumors in parameningeal sites were more likely to receive IMRT than 3D-CRT. IMRT became more common during the later years of the study. Patients receiving IMRT were more likely to receive >50 Gy, photon energy of {<=}6 MV, and >5 radiation fields than those who received 3D-CRT. The coverage of the IMRT planning target volume by the prescription dose was improved compared with the coverage using 3D-CRT with similar target dose heterogeneity. Conclusions: IMRT improved the target dose coverage compared with 3D-CRT, although an improvement in locoregional control or FFS could not be demonstrated in this population. Future studies comparing the integral dose to nontarget tissue and late radiation toxicity between the two groups are warranted.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Postoperative Radiotherapy in Prostate Cancer: The Case of the Missing Target

Purpose: Postoperative radiotherapy (XRT) increases survival in high-risk prostate cancer patients. Approximately 50% of patients on long-term follow-up relapse despite adjuvant XRT and the predominant site of failure remains local. Four consensus guidelines define postoperative clinical target volume (CTV) in prostate cancer. We explore the possibility that inadequate CTV coverage is an important cause of local failure. This study evaluates the utility of preoperative magnetic resonance imaging (MRI) in defining prostate bed CTV. Methods and Materials: Twenty prostate cancer patients treated with postoperative XRT who also had preoperative staging MRI were included. The four guidelines were applied and the CTVs were expanded to create planning target volumes (PTVs). Preoperative MRIs were fused with postoperative planning CT scans. MRI-based prostate and gross visible tumors were contoured. Three-dimensional (3D) conformal four- and six-field XRT plans were developed and dose-volume histograms analyzed. Subtraction analysis was conducted to assess the adequacy of prostate/gross tumor coverage. Results: Gross tumor was visible in 18 cases. In all 20 cases, the consensus CTVs did not fully cover the MRI-defined prostate. On average, 35% of the prostate volume and 32% of the gross tumor volume were missed using six-field 3D treatment plans. The entire MRI-defined gross tumor volume was completely covered in only two cases (six-field plans). The expanded PTVs did not cover the entire prostate bed in 50% of cases. Prostate base and mid-zones were the predominant site of inadequate coverage. Conclusions: Current postoperative CTV guidelines do not adequately cover the prostate bed and/or gross tumor based on preoperative MRI imaging. Additionally, expanded PTVs do not fully cover the prostate bed in 50% of cases. Inadequate CTV definition is likely a major contributing factor for the high risk of relapse despite adjuvant XRT. Preoperative imaging may lead to more accurate CTV definition, which should result in further improvements in survival for patients with high-risk prostate cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Generalizable Class Solutions for Treatment Planning of Spinal Stereotactic Body Radiation Therapy

Purpose: Spinal stereotactic body radiation therapy (SBRT) continues to emerge as an effective therapeutic approach to spinal metastases; however, treatment planning and delivery remain resource intensive at many centers, which may hamper efficient implementation in clinical practice. We sought to develop a generalizable class solution approach for spinal SBRT treatment planning that would allow confidence that a given plan provides optimal target coverage, reduce integral dose, and maximize planning efficiency. Methods and Materials: We examined 91 patients treated with spinal SBRT at our institution. Treatment plans were categorized by lesion location, clinical target volume (CTV) configuration, and dose fractionation scheme, and then analyzed to determine the technically achievable dose gradient. A radial cord expansion was subtracted from the CTV to yield a planning CTV (pCTV) construct for plan evaluation. We reviewed the treatment plans with respect to target coverage, dose gradient, integral dose, conformality, and maximum cord dose to select the best plans and develop a set of class solutions. Results: The class solution technique generated plans that maintained target coverage and improved conformality (1.2-fold increase in the 95% van't Riet Conformation Number describing the conformality of a reference dose to the target) while reducing normal tissue integral dose (1.3-fold decrease in the volume receiving 4 Gy (V{sub 4Gy}) and machine output (19% monitor unit (MU) reduction). In trials of planning efficiency, the class solution technique reduced treatment planning time by 30% to 60% and MUs required by {approx}20%: an effect independent of prior planning experience. Conclusions: We have developed a set of class solutions for spinal SBRT that incorporate a pCTV metric for plan evaluation while yielding dosimetrically superior treatment plans with increased planning efficiency. Our technique thus allows for efficient, reproducible, and high-quality spinal SBRT treatment planning.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Whole Brain Irradiation With Hippocampal Sparing and Dose Escalation on Multiple Brain Metastases: A Planning Study on Treatment Concepts

Purpose: To develop a new treatment planning strategy in patients with multiple brain metastases. The goal was to perform whole brain irradiation (WBI) with hippocampal sparing and dose escalation on multiple brain metastases. Two treatment concepts were investigated: simultaneously integrated boost (SIB) and WBI followed by stereotactic fractionated radiation therapy sequential concept (SC). Methods and Materials: Treatment plans for both concepts were calculated for 10 patients with 2-8 brain metastases using volumetric modulated arc therapy. In the SIB concept, the prescribed dose was 30 Gy in 12 fractions to the whole brain and 51 Gy in 12 fractions to individual brain metastases. In the SC concept, the prescription was 30 Gy in 12 fractions to the whole brain followed by 18 Gy in 2 fractions to brain metastases. All plans were optimized for dose coverage of whole brain and lesions, simultaneously minimizing dose to the hippocampus. The treatment plans were evaluated on target coverage, homogeneity, and minimal dose to the hippocampus and organs at risk. Results: The SIB concept enabled more successful sparing of the hippocampus; the mean dose to the hippocampus was 7.55 {+-} 0.62 Gy and 6.29 {+-} 0.62 Gy, respectively, when 5-mm and 10-mm avoidance regions around the hippocampus were used, normalized to 2-Gy fractions. In the SC concept, the mean dose to hippocampus was 9.8 {+-} 1.75 Gy. The mean dose to the whole brain (excluding metastases) was 33.2 {+-} 0.7 Gy and 32.7 {+-} 0.96 Gy, respectively, in the SIB concept, for 5-mm and 10-mm hippocampus avoidance regions, and 37.23 {+-} 1.42 Gy in SC. Conclusions: Both concepts, SIB and SC, were able to achieve adequate whole brain coverage and radiosurgery-equivalent dose distributions to individual brain metastases. The SIB technique achieved better sparing of the hippocampus, especially when a10-mm hippocampal avoidance region was used.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Adaptive/Nonadaptive Proton Radiation Planning and Outcomes in a Phase II Trial for Locally Advanced Non-small Cell Lung Cancer

Purpose: To analyze dosimetric variables and outcomes after adaptive replanning of radiation therapy during concurrent high-dose protons and chemotherapy for locally advanced non-small cell lung cancer (NSCLC). Methods and Materials: Nine of 44 patients with stage III NSCLC in a prospective phase II trial of concurrent paclitaxel/carboplatin with proton radiation [74 Gy(RBE) in 37 fractions] had modifications to their original treatment plans after re-evaluation revealed changes that would compromise coverage of the target volume or violate dose constraints; plans for the other 35 patients were not changed. We compared patients with adaptive plans with those with nonadaptive plans in terms of dosimetry and outcomes. Results: At a median follow-up of 21.2 months (median overall survival, 29.6 months), no differences were found in local, regional, or distant failure or overall survival between groups. Adaptive planning was used more often for large tumors that shrank to a greater extent (median, 107.1 cm{sup 3} adaptive and 86.4 cm{sup 3} nonadaptive; median changes in volume, 25.3% adaptive and 1.2% nonadaptive; P<.01). The median number of fractions delivered using adaptive planning was 13 (range, 4-22). Adaptive planning generally improved sparing of the esophagus (median absolute decrease in V{sub 70}, 1.8%; range, 0%-22.9%) and spinal cord (median absolute change in maximum dose, 3.7 Gy; range, 0-13.8 Gy). Without adaptive replanning, target coverage would have been compromised in 2 cases (57% and 82% coverage without adaptation vs 100% for both with adaptation); neither patient experienced local failure. Radiation-related grade 3 toxicity rates were similar between groups. Conclusions: Adaptive planning can reduce normal tissue doses and prevent target misses, particularly for patients with large tumors that shrink substantially during therapy. Adaptive plans seem to have acceptable toxicity and achieve similar local, regional, and distant control and overall survival, even in patients with larger tumors, vs nonadaptive plans.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Dosimetric Impact of Prostate Rotations During Electromagnetically Guided External-Beam Radiation Therapy

Purpose: To study the impact of daily rotations and translations of the prostate on dosimetric coverage during radiation therapy (RT). Methods and Materials: Real-time tracking data for 26 patients were obtained during RT. Intensity modulated radiation therapy plans meeting RTOG 0126 dosimetric criteria were created with 0-, 2-, 3-, and 5-mm planning target volume (PTV) margins. Daily translations and rotations were used to reconstruct prostate delivered dose from the planned dose. D{sub 95} and V{sub 79} were computed from the delivered dose to evaluate target coverage and the adequacy of PTV margins. Prostate equivalent rotation is a new metric introduced in this study to quantify prostate rotations by accounting for prostate shape and length of rotational lever arm. Results: Large variations in prostate delivered dose were seen among patients. Adequate target coverage was met in 39%, 65%, and 84% of the patients for plans with 2-, 3-, and 5-mm PTV margins, respectively. Although no correlations between prostate delivered dose and daily rotations were seen, the data showed a clear correlation with prostate equivalent rotation. Conclusions: Prostate rotations during RT could cause significant underdosing even if daily translations were managed. These rotations should be managed with rotational tolerances based on prostate equivalent rotations.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Robustness Against Interfraction Prostate Movement in Scanned Ion Beam Radiation Therapy

Purpose: To assess the robustness of scanned ion beam treatment plans against the interfraction internal target motion and evaluate the limits of validity of target-based isocenter realignment for prostate cancer radiation therapy. Methods and Materials: For 12 prostate patients, scanned beam carbon ion treatment plans were prepared using 2 lateral opposed beams and the raster scanning technique with different clinical target volume (CTV) to planning target volume (PTV) margins (2-10 mm). Internal target motion of 2-15 mm in anteroposterior (AP), superoinferior (SI), and left-to-right (LR) directions was simulated by displacing the CTV contours with respect to the computed tomography data. The plans were recalculated with and without target-based isocenter realignment and the CTV coverage was assessed. Results: For CTV shifts within the applied planning margin, the CI-98% is greater than 98.0%, both with and without isocenter realignment. Without realignment, because of the sharp lateral gradients, the CI-98% shows rapid fall as soon as the target shift exceeds the applied planning margin for all displacement directions. With isocenter realignment, the coverage improves notably for shifts in AP and SI directions and the CI-98% is restored to >95.0% for plans optimized with a 2-mm margin, >97% with a 3-mm margin, and >98% with larger margins. For large corrections, predominately in AP direction, cold spots in the CTV may occur. Their magnitude is dependent on the patients' individual anatomies. Conclusions: Within the physiological limits of internal prostate movement, target-based isocenter realignment results in improved CTV coverage for shifts in AP and SI directions exceeding the applied planning margin. Assuming optimal patient setup reproducibility (eg, immobilization, setup error correction, patient preparation protocols), hence negligible interfraction bone and soft-tissue variations, changes in traversed densities resulting from target-based realignment applied with a reduced planning margin do not induce significant dose deterioration in most of the cases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Scrotal Irradiation in Primary Testicular Lymphoma: Review of the Literature and In Silico Planning Comparative Study

We examined adjuvant irradiation of the scrotum in primary testicular lymphoma (PTL) by means of a literature review in MEDLINE, a telephone survey among Dutch institutes, and an in silico planning comparative study on scrotal irradiation in PTL. We did not find any uniform adjuvant irradiation technique assuring a safe planning target volume (PTV) coverage in published reports, and the definition of the clinical target volume is unclear. Histopathologic studies of PTL show a high invasion rate of the tunica albuginea, the epididymis, and the spermatic cord. In retrospective studies, a prescribed dose of at least 30 Gy involving the scrotum is associated with best survival. The majority of Dutch institutes irradiate the whole scrotum without using a planning computed tomography scan, with a single electron beam and a total dose of 30 Gy. The in silico planning comparative study showed that all evaluated approaches met a D{sub 95%} scrotal dose of at least 85% of the prescription dose, without exceeding the dose limits of critical organs. Photon irradiation with 2 oblique beams using wedges resulted in the best PTV coverage, with a mean value of 95% of the prescribed dose, with lowest maximum dose. Adjuvant photon or electron irradiation of the whole scrotum including the contralateral testicle with a minimum dose of 30 Gy is recommended in PTL. Computed tomography-based radiation therapy treatment planning with proper patient positioning and position verification guarantees optimal dose coverage.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of Various Online Strategies to Account for Interfractional Variations for Pancreatic Cancer

Purpose: To identify practical techniques to address the large interfractional variations for pancreas irradiation by comparing various used/proposed online strategies. Methods and Materials: The daily computed tomography (CT) images acquired using a respiration-gated in-room CT (CTVision; Siemens) for 10 pancreatic cancer patients treated with image guided radiation therapy (IGRT) were analyzed. The contours of the pancreas and organs at risk on each daily CT set were generated by populating from the planning CT using a deformable registration tool (ABAS; Elekta) with manual editing. Nine online strategies were considered: (1) standard IGRT (ie, IGRT with 0-mm additional margin [AM]); (2) IGRT with 2-mm AM; (3) IGRT with 5-mm AM; (4) IGRT with plan renormalized to maintain 95% planning target volume (PTV) coverage; (5) full-scale reoptimization; (6) reoptimization starting from the original plan; (7) segment aperture morphing (SAM) from the original plan, based on PTV shape change; (8) SAM plus segment weight optimization; and (9) reoptimization starting from the SAM plan. One-way analysis of variance was applied to plan qualities for the 9 strategies to assess statistical significance in difference. Results: The 3 IGRT strategies (1-3) lead to either inadequate PTV coverage or higher doses to critical structures, indicating that the additional margins alone are not adequate to account for the changes. The full-scale reoptimization results in the best plan but requires the delineation of several structures, which is time consuming. The SAM strategy (7) was the fastest one, because it requires delineating only 1 structure (target), and its plan quality was comparable to that for the full-scale reoptimization. Conclusion: Online replanning strategies can lead to either reduced organs-at-risk dose and/or improved target coverage as compared with the current practice of IGRT. The SAM-based online replanning is comparable to full-scale reoptimization and is efficient for practical use.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Intrafraction Prostate Translations and Rotations During Hypofractionated Robotic Radiation Surgery: Dosimetric Impact of Correction Strategies and Margins

Purpose: To investigate the dosimetric impact of intrafraction prostate motion and the effect of robot correction strategies for hypofractionated CyberKnife treatments with a simultaneously integrated boost. Methods and Materials: A total of 548 real-time prostate motion tracks from 17 patients were available for dosimetric simulations of CyberKnife treatments, in which various correction strategies were included. Fixed time intervals between imaging/correction (15, 60, 180, and 360 seconds) were simulated, as well as adaptive timing (ie, the time interval reduced from 60 to 15 seconds in case prostate motion exceeded 3 mm or 2° in consecutive images). The simulated extent of robot corrections was also varied: no corrections, translational corrections only, and translational corrections combined with rotational corrections up to 5°, 10°, and perfect rotational correction. The correction strategies were evaluated for treatment plans with a 0-mm or 3-mm margin around the clinical target volume (CTV). We recorded CTV coverage (V{sub 100%}) and dose-volume parameters of the peripheral zone (boost), rectum, bladder, and urethra. Results: Planned dose parameters were increasingly preserved with larger extents of robot corrections. A time interval between corrections of 60 to 180 seconds provided optimal preservation of CTV coverage. To achieve 98% CTV coverage in 98% of the treatments, translational and rotational corrections up to 10° were required for the 0-mm margin plans, whereas translational and rotational corrections up to 5° were required for the 3-mm margin plans. Rectum and bladder were spared considerably better in the 0-mm margin plans. Adaptive timing did not improve delivered dose. Conclusions: Intrafraction prostate motion substantially affected the delivered dose but was compensated for effectively by robot corrections using a time interval of 60 to 180 seconds. A 0-mm margin required larger extents of additional rotational corrections than a 3-mm margin but resulted in lower doses to rectum and bladder.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Impact of Intrafraction and Residual Interfraction Effect on Prostate Proton Pencil Beam Scanning

Purpose: To quantitatively evaluate the impact of interplay effect and plan robustness associated with intrafraction and residual interfraction prostate motion for pencil beam scanning proton therapy. Methods and Materials: Ten prostate cancer patients with weekly verification CTs underwent pencil beam scanning with the bilateral single-field uniform dose (SFUD) modality. A typical field had 10-15 energy layers and 500-1000 spots. According to their treatment logs, each layer delivery time was <1 s, with average time to change layers of approximately 8 s. Real-time intrafraction prostate motion was determined from our previously reported prospective study using Calypso beacon transponders. Prostate motion and beam delivering sequence of the worst-case scenario patient were synchronized to calculate the “true” dose received by the prostate. The intrafraction effect was examined by applying the worst-case scenario prostate motion on the planning CT, and the residual interfraction effect was examined on the basis of weekly CT scans. The resultant dose variation of target and critical structures was examined to evaluate the interplay effect. Results: The clinical target volume (CTV) coverage was degraded because of both effects. The CTV D{sub 99} (percentage dose to 99% of the CTV) varied up to 10% relative to the initial plan in individual fractions. However, over the entire course of treatment the total dose degradation of D{sub 99} was 2%-3%, with a standard deviation of <2%. Absolute differences between SFUD, intensity modulate proton therapy, and one-field-per-day SFUD plans were small. The intrafraction effect dominated over the residual interfraction effect for CTV coverage. Mean dose to the anterior rectal wall increased approximately 10% because of combined residual interfraction and intrafraction effects, the interfraction effect being dominant. Conclusions: Both intrafraction and residual interfraction prostate motion degrade CTV coverage within a clinically acceptable level. One-field-per-day SFUD delivered twice is as robust as the bilateral SFUD plan treated daily over the course of treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Hypercellularity Components of Glioblastoma Identified by High b-Value Diffusion-Weighted Imaging

Purpose: Use of conventional magnetic resonance imaging (MRI) for target definition may expose glioblastomas (GB) to inadequate radiation dose coverage of the nonenhanced hypercellular subvolume. This study aimed to develop a technique to identify the hypercellular components of GB by using high b-value diffusion-weighted imaging (DWI) and to investigate its relationship with the prescribed 95% isodose volume (PDV) and progression-free survival (PFS). Methods and Materials: Twenty-one patients with GB underwent chemoradiation therapy post-resection and biopsy. Radiation therapy (RT) treatment planning was based upon conventional MRI. Pre-RT DWIs were acquired in 3 orthogonal directions with b-values of 0, 1000, and 3000 s/mm{sup 2}. Hypercellularity volume (HCV) was defined on the high b-value (3000 s/mm{sup 2}) DWI by a threshold method. Nonenhanced signified regions not covered by the Gd-enhanced gross tumor volume (GTV-Gd) on T1-weighted images. The PDV was used to evaluate spatial coverage of the HCV by the dose plan. Association between HCV and PFS or other clinical covariates were assessed using univariate proportional hazards regression models. Results: HCVs and nonenhanced HCVs varied from 0.58 to 67 cm{sup 3} (median: 9.8 cm{sup 3}) and 0.15 to 60 cm{sup 3} (median: 2.5 cm{sup 3}), respectively. Fourteen patients had incomplete dose coverage of the HCV, 6 of whom had >1 cm{sup 3} HCV missed by the 95% PDV (range: 1.01-25.4 cm{sup 3}). Of the 15 patients who progressed, 5 progressed earlier, within 6 months post-RT, and 10 patients afterward. Pre-RT HCVs within recurrent GTVs-Gd were 78% (range: 65%-89%) for the 5 earliest progressions but lower, 53% (range: 0%-85%), for the later progressions. HCV and nonenhanced HCV were significant negative prognostic indicators for PFS (P<.002 and P<.01, respectively). The hypercellularity subvolume not covered by the 95% PDV was a significant negative predictor for PFS (P<.05). Conclusions: High b-value DWI identifies the hypercellular components of GB and could aid in RT target volume definition. Future studies will allow us to investigate the role of high b-value DWI in identifying radiation boost volumes and diagnosing progression.

62 RADIOLOGY AND NUCLEAR MEDICINE↗