Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “charging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

Data mining of plug-in electric vehicles charging behavior using supply-side data

This paper aims to better understand the charging patterns of plug-in electric vehicles (PEVs) and identify factors that may significantly impact PEVs’ charging behavior. We collected 189,864 supply-side charging session data over 13 months from 821 charging stations in Illinois from ChargePoint. Through descriptive and regression analyses, we characterize the distributions of key charging behavior indicators, including charging location, dwell time, and battery start state of charge (SOC), and quantify the impacts of closely related factors on these charging behaviors. In this work, we find that: (1) PEVs are more likely to charge in the morning at multifamily commercial locations with a lower start SOC compared with single family residential locations; (2) Weekday and morning sessions are more likely to utilize workplace charging and have shorter dwell time compared with weekend and afternoon sessions; (3) Single family residential area and locations with Levels 1/2 chargers have a higher start SOC and longer dwell time compared with other locations and DC fast chargers (DCFCs). These findings provide policy insights to identify potential time and locations to incentivize PEVs for grid services, as well as identify critical location categories for further charging infrastructure investment to better reduce range anxiety and promote PEV adoption.

33 ADVANCED PROPULSION SYSTEMS↗

Understanding particle size effect on fast-charging behavior of graphite anode using ultra-thin-layer electrodes

Extreme fast charging (≤ 15 min) of lithium-ion batteries is highly desirable to accelerate mass-market adoption of electric vehicles. However, significant capacity fading, as well as safety issues due to the lithium plating caused by the fast charging rate, limit its implementation. In this study, we investigated the fast-charging capability of graphite materials with various particle sizes. To eliminate the Li + ion concentration gradient effect across the thickness of the electrode, ultra-thin-layer graphite electrodes were developed to investigate the "real" fast-charging capability of graphite at the particle level. Electrochemical assessments as well as microscopic characterizations revealed that smaller particles exhibited superior fast-charging performance, featuring enhanced capacity reversibility, faster charging rate, and less lithium plating under the same fast-charging conditions. It is shown that small-particle graphite (mean radius of 3.3 μm) could withstand a 4C charge (to 80 % state-of-charge) without plating, with minimal plating occurring at 6C. Thicker particles exhibited plating at lower C-rates. Since the experimental data could not directly explain whether intra-particle diffusion limitations or interfacial reaction limitations dominated the plating mechanism, the pseudo-2-dimensional model was used to evaluate the most likely plating mechanism. The model suggested that particle-level diffusion is the dominant mechanism contributing to plating at high rates. Finally, this work provides comprehensive insights into the particle size effects on fast-charging capability, offering a better understanding of fast-charging behavior and valuable guidance for designing optimal electrode architecture for high-rate lithium-ion batteries.

25 ENERGY STORAGE↗

Electrifying New York City Ride-Hailing fleets: An examination of the need for public fast charging

This report assesses the scale of public fast charging needed to electrify approximately 20,000 vehicles across the yellow cab and for-hire segments in New York City. The analysis considers real-world trip data in conjunction with driver home locations, overnight charging access rates, driver schedules, and more. Outcomes indicate that the existing charging network in New York City is not adequate even in the most optimistic scenario; 1,054 150-kW ports are required when 15% of drivers have access to overnight charging, whereas 367 150-kW ports are needed when 100% of drivers have access. Results also indicate that although charging is demanded in areas nearby high trip demand, fast charging ports are also demanded in areas near driver residences as a supplement for home charging in scenarios with limited overnight charging access. These findings motivate investment into both overnight charging and public fast charging to meet the charging demands of ride-hailing fleets.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Techno-economic and environmental assessment of solar-based electrical vehicles charging stations integrated with hydrogen production

With the growing interest in adopting both commercial and residential electric vehicles (EVs) utilizing green renewable energy, the techno-economic assessment of EV charging stations with solar energy is a critical aspect of the transition to sustainable transportation. However, battery storage capacity for variable solar energy production is becoming increasingly less cost-effective due to the higher Lithium price. Complementing solar energy production and battery storage, the potential of combining green hydrogen fuel energy integration with solar energy for EV charging stations can provide a sustainable alternative to reach carbon-free transportation. This research aims to assess the technical and economic viability of grid-connected Photovoltaic (PV)-based EV charging stations across Kentucky based on existing EV load profiles. The study considers different PV system sizes, locations, orientations, and the impact of net metering policies and electricity tariffs on the profitability of the PV systems. Further, using excess PV energy, Lithium-Ion batteries will be charged, which will be assessed considering the techno-economic and environmental impacts of green EV charging stations. To further enhance green renewable energy production, we also investigated the feasibility of on-grid PV-based EV charging stations with Lithium-Ion batteries charged during low tariff periods. In comparison with these scenarios, we studied the potential benefits of integrating green hydrogen energy production using excess solar energy with and without governmental incentives. Furthermore, we assess the environmental impact of these green EV charging stations across Kentucky. Our study indicates that EV stations across Kentucky have similar techno-economic feasibility with insignificant deviation in the levelized cost of electricity, payback period, and PV energy fraction with/without Li-Ion batteries. However, with green hydrogen production, the marginal H 2 production cost indicates the first scenario (on-grid PV energy charging) is the most significant, roughly 10 USD/Kg, which is similar to 1.5 times higher than the second (charging during low-tariff periods) and the third scenarios (power grid to satisfy the demand deficit - approximately 6.5 USD/Kg). From the environmental perspective, the second scenario would be a good option for either hybrid EV/H 2 or EV charging stations in Kentucky, factoring in the hydrogen production cost and the carbon footprint.

08 HYDROGEN↗

Modeling charging behavior of battery electric vehicle drivers: A cumulative prospect theory based approach

The behavior of drivers in charging a battery electric vehicle (BEV) can be influenced by psychological factors such as personality and risk preference. This paper proposes a cumulative prospect theory (CPT) based modeling framework to describe the charging behavior of BEV drivers. CPT captures an individual’s attitude and preference toward risk in the decision-making process. A BEV mass-market scenario is constructed using the 2017 National Household Travel Survey (NHTS) data. This work applies the CPT-based charging behavior model to study the battery state-of-charge (SOC) when drivers decide to charge their vehicles, charging timing and location choices, and charging power demand profile under the mass-market scenario. In addition, sensitivity analyses are used to examine the drivers’ risk attitudes and public charger network coverage. BEV drivers who reflect a higher degree of risk-seeking tend to charge vehicles at a lower SOC. Some home charging shifts to workplace and public charging as the public charger network expands, but home charging still plays the most significant role in BEV use. The power demand from public chargers increases critically with BEV expansion and has a larger impact on the power grid. The time-of-use (TOU) electricity rate can shift peak power demand to off-peak periods from midnight to early morning.

2017 National Household Travel Survey (NHTS)↗

Learning-based demand-supply-coupled charging station location problem for electric vehicle demand management

We present a learning-based, demand-supply-coupled optimization model for the charging station location problem (CSLP), aiming to integrate the concept of electric vehicle (EV) charging demand management into the planning of charging infrastructures. In stage one, a gradient boosting-based learning model is developed to predict the charging demand of a charging station based on 15 defined features. Next, in stage two, a demand–supply-coupled CSLP model is developed to optimize the total charging usage rates of both existing and newly selected charging stations. We design a gradient-based stochastic spatial search algorithm to solve the proposed model. A case study with 6-year charging event data from Kansas City Missouri is performed. Results show that the proposed method can generate satisfactory charging demand predictions, and can increase charging usage rates by 14%, outperforming two benchmark approaches. Furthermore, the results of this research are poised to guide agencies in identifying optimal locations for new charging stations.

33 ADVANCED PROPULSION SYSTEMS↗

Particle size effects in particle-particle triboelectric charging studied with an integrated fluidized bed and electrostatic separator system

Fundamental studies of triboelectric charging of granular materials via particle-particle contact are challenging to control and interpret because of foreign material surfaces that are difficult to avoid during contacting and measurement. The measurement of particle charge itself can also induce charging, altering results. Here, we introduce a completely integrated fluidized bed and electrostatic separator system that charges particles solely by interparticle interactions and characterizes their charge on line. Particles are contacted in a free-surface fluidized bed (no reactor walls) with a well-controlled fountain-like flow to regulate particle-particle contact. The charged particles in the fountain are transferred by a pulsed jet of air to the top of a vertically-oriented electrostatic separator consisting of two electrodes at oppositely biased high voltage. The free-falling particles migrate towards the electrodes of opposite charge and are collected by an array of cups where their charge and size can be determined. We carried out experiments on a bidisperse size mixture of soda lime glass particles with systematically varying ratios of concentration. Results show that larger particles fall close to the negative electrode and smaller particles fall close to the positive electrode, consistent with theory and prior experiments that larger particles charge positively and smaller particles charge negatively. The segregation of particles by charge for one of the size components is strongest when its collisions are mostly with particles of the other size component; thus, small particles segregate most strongly to the negative sample when their concentration in the mixture is small (and analogous results occur for the large particles). Furthermore, we find additional size segregation due to granular flow, whereby the fountain becomes enriched in larger particles as the smaller particles are preferentially expelled from the fountain.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Interpretable Machine Learning for Characterizing Electric Vehicle Charging Behavior: Insights from Real-World Data

As electric vehicle (EV) adoption rises globally, concerns about the impact on aging electrical grids grow, particularly regarding the charging behavior of EV drivers. This study analyzes real-world driving and charging data from Ford battery electric vehicles (BEVs) collected between 2018 and 2019 to develop interpretable models that characterize charging behavior and quantify influencing factors. Prior research has relied on assumptions regarding driver behavior, often overlooking actual charging patterns. By employing generalized linear mixed models (GLMMs), this work offers insights into how various elements, such as next trip distance and state of charge (SOC), influence charging decisions. The dataset comprises over three million park-trip pairs from 1,997 vehicles, revealing that features related to driving behavior significantly dictate charging behavior, while infrastructure and regional factors have lesser impacts. The findings suggest that existing simulation models may oversimplify EV charging behavior assumptions. This work utilizes real-world EV driving and charging data to train interpretable models that describe charging behavior and quantify the factors most associated with how drivers use charging infrastructure. This research underscores the need for interpretable, data-driven methodologies to inform future EV infrastructure planning and grid management.

29 - ENERGY PLANNING, POLICY AND ECONOMY↗

Distribution System V1G PEV Charging Impacts Report

Plug-in Electric Vehicles (PEVs) are a clean form of transportation that will require a new control paradigm between the energy supply and the transportation sectors as PEV adoption continues to grow. Meeting the projected PEV energy demands will require implementing PEV / grid integration methods beyond charging PEVs at incentivized times. MATLAB was used to simulate the daily vehicle trip demands and charging processes of hundreds of PEVs. The National Household Travel Survey (NHTS) data was used as the source of vehicle travel data, and EV Project provided measured PEV charging data to calibrate the PEV population models. GridLAB-D analyses used a prototypical feeder and PEV population models to evaluate residential PEV V1G (unidirectional) charging in multiple locations, V1G PEV distribution feeder impacts, Time-Of-Use (TOU) rate effects on PEV charging, and charging control methods. The key findings were: optimized charging using California TOU rates could result in savings of over $20 per month for non-TOU program participants; non-TOU participants consume 30-40% of PEV charging energy; about 50% of PEV drivers have their transportation fuel bill reduced by 50 dollars per month; 6.6kW charging will cause distribution transformer power limits to be exceeded on prototypical feeders if the household PEV adoption rate reaches 0.75 PEVs per home; distribution feeder loading is proportional to PEV charging rate; a method was devised to remotely identify when residential transformer overloads occur using changes in PEV charging rate; and the low-cost TOU period is composed of a distribution of PEVs needing small, medium and larger energy needs that can be more effectively shifted as groups to mitigate the TOU peak power and enable a higher PEV adoption rate per household without overloading distribution transformers.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Inventory of Public Key Cryptography in US Electric Vehicle Charging

Electric vehicles (EVs) and charging infrastructure are networked systems, which employ high-level communications in support of charging and grid service decisions. Public key cryptography (PKC) underlies much of the security and privacy protections of the information exchange. We are entering a new epoch where quantum computing threats must be seriously considered. A sufficiently large quantum computer, so named Cryptographically Relevant Quantum Computer (QRQC), will be able to perform the mathematical operations to efficiently attack the underpinnings of traditional PKC, thus jeopardizing the digital foundations for trust, communications security, and data security. Estimates suggest a QRQC can break public key encryption and digital signatures in the manner of tens to hundreds of hours, compared to traditional computing that would demand more than 10 18 years in a brute force-style attack. A consensus belief of quantum theorists, quantum experimenters, and cryptographers suggest that the quantum threat will be likely realized in the next twenty years. To address the threat, post-quantum cryptography, which is cryptosystems that are designed to be secure against both traditional and quantum computing threats, must be adopted. Migration from traditional PKC to quantum-resilient cryptography is a global undertaking and likely represents the largest transition in computing history. The nascent state of EV public key infrastructure, combined with limited adoption of the vehicle secure charging features, presents an opportunity to establish a preference for quantum-resistant cryptography as a step on the migration path. Delays will stunt the efforts as rapidly accelerating EVs sales and huge infrastructure investments will create large growing bases of long-lived vehicles and infrastructure. Migration preparations can commence while NIST continues the process to standardize post-quantum cryptography (PQC), which are quantum-resilient algorithms designed to be secure against traditional and quantum computing threats. The first step in preparing EV charging is to identify the presence of traditional public key cryptography algorithms and applications. With this objective in mind, this report is intended to advise the vehicle manufacturers, charging station manufacturers, charging station operators, charge network providers and other EV charging stakeholders with information on traditional PKC application and the potential risks when PKC becomes insecure. This report, the first in a series of reports discussing the topics existing at the confluence of post-quantum cryptography adoption and EV charging, identifies traditional public key applications employed and identifies potential consequences of leaving EV charging infrastructure vulnerable to quantum computing. The focus remains squarely on the of EV charging and infrastructure with respect to PKC and is believed by the authors to complement the NIST SP 1800-38 Migration to Post-Quantum Cryptography. While the report is centered on infrastructure, there are implications to vehicles.

33 ADVANCED PROPULSION SYSTEMS↗

Advancing Grid Resilience through Smart Charge Management: Findings from Maryland’s Pilot

This report presents research findings from a four-year Smart Charge Management (SCM) pilot program conducted by Maryland’s largest electric utilities—Baltimore Gas and Electric (BGE), Potomac Electric Power Company (Pepco), and Delmarva Power & Light (DPL)—to evaluate strategies for optimizing electric vehicle (EV) charging loads and enhancing grid stability. Supported by the U.S. Department of Energy (DOE), Argonne National Laboratory collaborated with all project partners and examined the effectiveness of Time-of-Use (TOU) and Load Balancing (LB) strategies in managing peak demand, deferring costly infrastructure upgrades, and reducing grid constraints at the feeder level. Using charging data from over 4,600 EV drivers, the study analyzed SCM’s impact on the distribution systems of BGE and Pepco, which consists of over 2000 feeders. Unlike prior research that focused on system-wide trends or synthetic feeders, this analysis offers granular, feeder-level insights based on real-world operational data. It highlights how transformer density, load profiles, and infrastructure constraints influence smart charging performance. Results show feeder-level conditions play a crucial role in SCM effectiveness, with most feeders benefiting more from LB, while TOU-based SCM may be sufficient for others. By 2035, LB reduced peak charging loads by 27% on average, compared to 23% under TOU-based SCM, though some feeders saw reductions exceeding 35%, while others experienced minimal impact. Feeders with higher transformer utilization and limited capacity benefited more from LB, which more effectively distributed charging demand during off-peak hours. Beyond reducing grid constraints, SCM offers long-term operational and financial benefits. By shifting EV charging demand strategically, utilities can optimize asset utilization, delay infrastructure investments, and enhance grid performance. In terms of infrastructure upgrade deferrals, at the feeder level, LB consistently reduced peak charging loads and resulting infrastructure upgrade costs, particularly in high EV enrollment areas, decreasing the number of overloaded transformers by up to 35%, while TOU-based SCM achieved 20-30% reductions depending on feeder characteristics. At the system level, LB has the potential to defer total upgrade costs by $\$$186 million for BGE, compared to $\$$159 million under TOU-based SCM. For Pepco, TOU-based SCM performed slightly better, deferring upgrade costs by $\$$30 million, compared to $\$$29 million under LB. Section 4.5 reviews some of the system differences between BGE and Pepco. However, as EV adoption scales, TOU-based SCM will introduce secondary peak charging loads, reinforcing the need for more advanced, adaptive SCM approaches to prevent new grid challenges. As EV adoption continues to grow, feeder-level managed charging strategies will be essential for mitigating grid stress, improving infrastructure efficiency, and maintaining energy affordability for consumers. This report provides critical insights for utilities, Public Utility Commissions (PUCs), and state agencies on the role of feeder-specific smart charging in infrastructure planning, policy development, and grid modernization. The findings underscore the importance of tailored, data-driven SCM solutions that align with local grid conditions, ensuring a resilient, cost-effective transition to increasing EV adoption while safeguarding distribution system performance.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Challenges of Fast Charging for Electric Vehicles and the Role of Red Phosphorous as Anode Material: Review

Electric vehicles (EVs) are being endorsed as the uppermost successor to fuel-powered cars, with timetables for banning the sale of petrol-fueled vehicles announced in many countries. However, the range and charging times of EVs are still considerable concerns. Fast charging could be a solution to consumers’ range anxiety and the acceptance of EVs. Nevertheless, it is a complicated and systematized challenge to realize the fast charging of EVs because it includes the coordinated development of battery cells, including electrode materials, EV battery power systems, charging piles, electric grids, etc. This paper aims to serve as an analysis for the development of fast-charging technology, with a discussion of the current situation, constraints and development direction of EV fast-charging technologies from the macroscale and microscale perspectives of fast-charging challenges. If the problem of fast-charging can be solved, it will satisfy consumers’ demand for 10-min charging and accelerate the development of electric vehicles. This paper summarized the development statuses, issues, and trends of the macro battery technology and micro battery technology. It is emphasized that to essentially solve the problem of fast charging, the development of new battery materials, especially anode materials with improved lithium ion diffusion coefficients, is the key. Finally, it is highlighted that red phosphorus is one of the most promising anodes that can simultaneously satisfy the double standards of high-energy density and fast-charging performance to a maximum degree.

33 ADVANCED PROPULSION SYSTEMS↗

Deep Dielectric Charging of Spacecraft Polymers by Energetic Protons

The majority of research in the field of spacecraft charging concentrates on electron charging effects with little discussion of charging by protons. For spacecraft orbiting in the traditional LEO and GEO environments this emphasis on electrons is appropriate since energetic electrons are the dominant species in those orbits. But for spacecraft in orbits within the inner radiation belts or for interplanetary and lunar space probes, proton charging (center dot) effects may also be of concern. To examine bulk spacecraft charging effects in these environments several typical highly insulating spacecraft polymers were exposed to energetic protons (center dot) with energies from 1 Me V to lO Me V to simulate protons from the solar wind and from solar energetic proton events. Results indicate that effects in proton charged dielectrics are distinctly different than those observed due to electron charging. In most cases, the positive surface potential continued to increase for periods on the order of minutes to a day, followed by long time scale decay at rates similar to those observed for electron charging. All samples charged to positive potentials with substantially lower magnitudes than for equivalent electron doses. Possible explanations for the different behavior of the measured surface potentials from proton irradiation are discussed; these are related to the evolving internal charge distribution from energy dependent electron and proton transport, electron emission, charge migration due to dark current and radiation induced conductivity, and electron capture by embedded protons.

radiation induced conductivity↗

Developing extreme fast charge battery protocols – A review spanning materials to systems

Extreme fast charging (XFC) has become a focal research point in the lithium-battery community over the last several years. As adoption of electric vehicles increases, fast charging has become a key driver in enhancing consumer recharge experience. Recently, the research community has made significant improvements in developing charge protocols to support XFC. New charge protocol designs derived using a combination of advanced, physically derived models, and electrochemical and secondary characterization methods, increase charge acceptance and decrease aging. By coordinating these methods and modifying protocols to account for different material constraints, including lithium plating and cathode particle degradation, novel charge protocols have increased the energy accepted during charging by over 25% in 10 min and increased the charge acceptance prior to a constant-voltage step by approximately 3x. Here, we review several charge-protocol advances, aging factors which are enhanced by XFC and advances which will enable adoption of XFC capable vehicles. These advances include implementing machine learning and other detection algorithms to reduce and classify lithium plating, which is known to significantly degrade cell performance and reduce cell life. The review concludes by discussing full-system fast charge requirements, including electric vehicle service equipment needs for implementing XFC protocols.

25 ENERGY STORAGE↗

Charged anisotropic matter with linear or nonlinear equation of state

Ivanov pointed out substantial analytical difficulties associated with self-gravitating, static, isotropic fluid spheres when pressure explicitly depends on matter density. Simplifications achieved with the introduction of electric charge were noticed as well. We deal with self-gravitating, charged, anisotropic fluids and get even more flexibility in solving the Einstein-Maxwell equations. In order to discuss analytical solutions we extend Krori and Barua's method to include pressure anisotropy and linear or nonlinear equations of state. The field equations are reduced to a system of three algebraic equations for the anisotropic pressures as well as matter and electrostatic energy densities. Attention is paid to compact sources characterized by positive matter density and positive radial pressure. Arising solutions satisfy the energy conditions of general relativity. Spheres with vanishing net charge contain fluid elements with unbounded proper charge density located at the fluid-vacuum interface. Notably the electric force acting on these fluid elements is finite, although the acting electric field is zero. Net charges can be huge (10{sup 19}C) and maximum electric field intensities are very large (10{sup 23}-10{sup 24} statvolt/cm) even in the case of zero net charge. Inward-directed fluid forces caused by pressure anisotropy may allow equilibrium configurations with larger net charges and electric field intensities than those found in studies of charged isotropic fluids. Links of these results with charged strange quark stars as well as models of dark matter including massive charged particles are highlighted. The van der Waals equation of state leading to matter densities constrained by cubic polynomial equations is briefly considered. The fundamental question of stability is left open.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Electric Vehicles at Scale (EVs@Scale) Laboratory Consortium Deep-Dive Technical Meetings: High Power Charging (HPC) Summary Report

Electric vehicle (EV) adoption will change the composition of EV charging load to higher-power charging as more medium- (MD) and heavy-duty (HD) applications are electrified, and as all vocations, including light-duty (LD) vehicles, are capable of faster charging. These shifts provide the opportunity for high-power charging (HPC) and facility equipment to evolve and improve efficiency, cost, and space. High-Power Electric Vehicle Charging Hub Integration Platform (eCHIP) project designs and develops a high-power, interoperable charging experimental platform to research, develop, and demonstrate the integration approaches and technology solutions. The project addresses (1) interconnection and management of a grid-tied inverter; (2) development of a DC distribution system that is responsible for system energy management, interoperability, and DC protection; (3) modular DC/DC conversion for vehicle charging; (4) EV charging interface and DC/DC integration; and (5) smart charge control and vehicle-to-edge (vehicle-to-building [V2B], vehicle-to-everything [V2X]) capability. This summary presentation is the first technical progress output of the project. It provides insight for the first deep-dive technical meeting outputs in terms of research presentations and also includes summary of the discussions occurred in the follow-up breakout sessions. The summary presentation covers three technical areas: (1) HPC: State of the art power architectures and the design of the power electronics, (2) Modeling, energy management, and power control in the HPC station, and (3) Codes and standards work that are in line with the previous two topic areas.

ADVANCED PROPULSION SYSTEMS,POWER TRANSMISSION AND↗

Can Charge Transfer Across C─H⋅⋅⋅O Hydrogen Bonds Stabilize Oil Droplets in Water?

Oil-water emulsions resist aggregation due to the presence of negative charges at their surface that leads to mutual repulsion between droplets, but the molecular origin of oil charge is currently under debate. Although much evidence has suggested that ionic species must accumulate at the interface, an alternative perspective attributes the negative charge on the oil droplet to charge transfer of electron density from water to oil molecules. Although the charge transfer mechanism is consistent with the correct sign of oil charge, it is just as important to provide good estimates of the charge magnitude to explain emulsion stability and electrophoresis experiments. Here, we show using energy decomposition analysis that the amount of net flow of charge from water to oil is negligibly small due to nearly equal forward and backward charge transfer through weak oil-water interactions, such that oil droplets would be unstable and coalesce, contrary to experiment. The lack of charge transfer also explains why vibrational sum frequency scattering reports a blue shift in the oil C-H frequency when forming emulsions with water, which arises from Pauli repulsion due to localized confinement at the interface. Finally, unlike ions, neither charge transfer nor dynamic polarization can produce a finite conductivity needed to couple to electric fields that would explain electrophoretic mobility.

Zhao, Ruoqi↗

Thermal response of a series- and parallel-connected solar energy storage to multi-day charge sequences

The thermal response of a multi-tank thermal storage was studied under variable charge conditions. Tests were conducted on an experimental apparatus that simulated the thermal charging of the storage system by a solar collector over predetermined (prescribed) daylong periods. The storage was assembled from three standard 270 L hot-water storage tanks each charged through coupled, side-arm, natural convection heat exchangers which were connected in either a series- or parallel-flow configuration. Both energy storage rates and tank temperature profiles were experimentally measured during charge periods representative of two consecutive clear days or combinations of a clear and overcast day. During this time, no draw-offs were conducted. Of particular interest was the effect of rising and falling charge-loop temperatures and collector-loop flow rate on storage tank stratification levels. Results of this study show that the series-connected thermal storage reached high levels of temperature stratification in the storage tanks during periods of rising charge temperatures and also limited destratification during periods of falling charge temperature. This feature is a consequence of the series-connected configuration that allowed sequential stratification to occur in the component tanks and energy to be distributed according to temperature level. This effect was not observed in the parallel charge configuration. A further aspect of the study investigated the effect of increasing charge-loop flow rate on the temperature distribution within the series-connected storage and showed that, at high flow rates, the temperature distributions were found to be similar to those obtained during parallel charging. A disadvantage of both the high-flow series-connected and parallel-connected multi-tank storage is that falling charge-loop temperatures, which normally occur in the afternoon, tend to mix and destratify the storage tanks. (author)

14 SOLAR ENERGY↗