Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “calibrated”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

Utah FORGE: Wells 16A(78)-32 and 16B(78)-32 Extended Circulation Test Data - August and September 2024

The dataset includes data collected during an extended circulation test conducted at the Utah FORGE site between August 8 and September 5, 2024. It provides uncorrected, raw digital data from the test, along with calibration information and a final report detailing the test procedures and corrections. The data is bundled in a single .zip file containing both field calibration and test data. Files include manual calibration data for temperature, pressure, and flow meters, as well as uncorrected, time-stamped measurements recorded in 30-second intervals, such as wellhead pressures, flow rates, and temperatures for wells 16A(78)-32 and 16B(78)-32. Additionally, the final report offers insights into the test methodology and provides guidelines on how to apply field calibrations to correct the raw Pason data.

15 GEOTHERMAL ENERGY↗

AWSD Reactive Burn Model for High Explosive LX‐14

ABSTRACT The results of an Arrhenius–Wescott–Stewart–Davis (AWSD) reactive flow calibration for the HMX‐based high explosive LX‐14 are presented. The parameters in the AWSD model are calibrated to experimental thermodynamic and gas gun data and to computational results from thermochemical calculations. There is no experimental rate stick data available for LX‐14; therefore, scaled experimental results from other PBX‐based high explosives are used in the calibration to fill this gap in data. Strong agreement is observed between the calibrated AWSD model and experimental data for LX‐14, including validation data that were not used in the calibration procedure. The developed model more accurately describes experimental shock‐to‐detonation results compared to several other reactive flow models for LX‐14 from the literature. The presented results illustrate that the AWSD model is capable of quantitatively describing the reactive burn of LX‐14.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Long-term measurements in a mixed-grass prairie reveal a change in soil organic carbon recalcitrance and its environmental sensitivity under warming

Soil respiration, the major pathway for ecosystem carbon (C) loss, has the potential to enter a positive feedback loop with the atmospheric CO2 due to climate warming. For reliable projections of climate-carbon feedbacks, accurate quantification of soil respiration and identification of mechanisms that control its variability are essential. Process-based models simulate soil respiration as functions of belowground C input, organic matter quality, and sensitivity to environmental conditions. However, evaluation and calibration of process-based models against the long-term in situ measurements are rare. Here, we evaluate the performance of the Terrestrial ECOsystem (TECO) model in simulating total and heterotrophic soil respiration measured during a 16-year warming experiment in a mixed-grass prairie; calibrate model parameters against these and other measurements collected during the experiment; and explore whether the mechanisms of C dynamics have changed over the years. Calibrating model parameters against observations of individual years substantially improved model performance in comparison to pre-calibration simulations, explaining 79–86% of variability in observed soil respiration. Interannual variation of the calibrated model parameters indicated increasing recalcitrance of soil C and changing environmental sensitivity of microbes. Overall, we found that (1) soil organic C became more recalcitrant in intact soil compared to root-free soil; (2) warming offset the effects of increasing C recalcitrance in intact soil and changed microbial sensitivity to moisture conditions. Furthermore, these findings indicate that soil respiration may decrease in the future due to C quality, but this decrease may be offset by warming-induced changes in C cycling mechanisms and their responses to moisture conditions.

59 BASIC BIOLOGICAL SCIENCES↗

A macro-micro approach for identifying crystal plasticity parameters for necking and failure in nickel-based alloy haynes 282

Here, this work develops a two-scales macro-micro approach to address the challenge in calibrating crystal plasticity microstructural models when samples undergo necking prior to fracture. The crystal plasticity models are crucial for predicting the materials’ plastic deformation and failure at the microstructure level, identifying the materials’ intrinsic properties as well as investigating the microstructure-properties relationships. However, after necking occurs, the experimentally measured stress-strain curves fail to reflect the materials ‘true’ stress-strain behavior and cannot be directly fitted into crystal plasticity models. The proposed macro-micro approach employs a top-down strategy to address this challenge, which has been studied with experimental tests on precipitation-strengthened Ni-based superalloy Haynes® 282®. In this approach, a macro rate-dependent anisotropic plasticity model with Voce-type hardening and Rice-Tracey damage law is first utilized to model the deformation and failure of the tensile bar, and calibrated by matching the stress-strain curves, necking strain, and reduction of area. Especially, to match the testing results under different applied strain rates, the rate-sensitivity parameter m and saturation stress in the elasticity model are modified to incorporate dependence on the local strain rate. Then, the ‘true’ stress-strain behaviors are extracted from the necking zone of the macro-model, which are used to calibrate a micro-model with explicit microstructures and governed by an extended crystal plasticity law. The consistency between the micro-model and macro-model are enforced during calibration. The calibration outcomes from the crystal plasticity model elucidate the materials intrinsic properties for slip, hardening, and failure, which is vital for further investigations into the microstructure-properties relationship and for accurate prediction of the material behavior under various test and service conditions.

36 MATERIALS SCIENCE↗

Nondestructive measurements of residual 235 U mass of Israeli Research Reactor-1 fuel using the Advanced Experimental Fuel Counter

In 2018, a measurement campaign took place with participants from Los Alamos National Laboratory (LANL), the Nuclear Research Centre-Negev (NRCN) and Soreq Nuclear Research Center (SNRC) at the Israeli Research Reactor-1 (IRR-1) in which 14 of the reactor’s used fuel assemblies (FAs) with varied amount of depletion were measured with the nondestructive assay instrument Advanced Experimental Fuel Counter (AEFC). Designed for safeguards purposes, the AEFC measures both neutrons emitted from the FA (passive neutrons) and fission neutrons induced by an external neutron source (in this experiment, 252 Cf). Signals recorded with the AEFC include total neutron count rates (Singles), time-correlated neutron count rates (Doubles), and total gamma-ray count rates. The 235 U content of the FAs was previously assessed by two independent methods: (1) measurement of the transparency of the FA to low-energy gamma rays from an activated rhenium source (rhenium gamma transmission, or the RGT method) and (2) calculation of the 30-year burnup history of the core using detailed three-dimensional Monte-Carlo core depletion calculations. The results from the FAs that had been measured via the RGT method were used to construct the calibration curves, which translate the AEFC count rates to 235 U mass. Then, the calibration was evaluated using AEFC measurements of six additional FAs that were not measured via the RGT method. From the results, it was determined the Doubles calibration curve was more reliable than that of the Singles and follows a simple second-order polynomial fit for the whole range of residual 235 U mass content, albeit with larger statistical uncertainty. Detailed uncertainties quantification was conducted for both the AEFC Singles and Doubles. This includes the analysis of statistical uncertainties, calibration uncertainty, and random uncertainties due to the sensitivity of the AEFC to several sources of uncertainty, namely the FA position, FA orientation, interrogation source position, and ambient pool temperature. Finally, an overall total uncertainty of 6 g of 235 U is estimated for the Singles and Doubles, which is mainly due to calibration uncertainty (for the Singles) and statistical uncertainty (for the Doubles), and which constitutes 3%–6% of the 235 U total mass in the FAs, depending on their level of depletion.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

RELAP5-3D validation studies based on the High Temperature Test facility

In the spring and summer of 2019, experiments were conducted at the High Temperature Test Facility (HTTF) that form the basis of an upcoming high-temperature gas-cooled reactor (HTGR) thermal hydraulics (T/H) benchmark. HTTF is an integral effects test facility for HTGR T/H modeling validation. This paper presents RELAP5-3D models of two of those experiments: PG-27, a pressurized conduction cooldown (PCC); and PG-29, a depressurized conduction cooldown (DCC). These models used the RELAP5-3D model of HTTF originally developed by Paul Bayless as a starting point. The sensitivity analysis and uncertainty quantification code, RAVEN was used to perform calibration studies for the steady-state portion of PG-27. Here we developed four PG-27 calibrations based on steady-state conditions. These calibrations all used an effective thermal conductivity equal to 36 % of the measured thermal conductivity, but they differed with respect to the frictional pressure drops and radial conduction models. These models all captured the trends in steady-state temperature distributions and transient temperature behavior well. All four calibrations show room for improvement in predicting the transient temperature rise. The smallest error in temperature rise during the transient was a 21 % underprediction, and the largest was a 48 % underprediction. The errors in transient temperature rise are largely a result of a mismatch in power density between the RELAP5-3D model and the experiment due to the location of active heater rods along the boundary between heat structures in the model. The best of these calibrations was applied to PG-29 to model the DCC. Once again, temperatures during the transient were underpredicted but trends in temperature were captured. The RELAP5-3D model captured trends in the data but could not reproduce measured temperatures exactly. This result is not attributed to deficiencies in the experimental data or to RELAP5–3D itself. Rather, this result likely arises due to the some of the assumptions and decisions made when the RELAP5-3D model was first developed, prior to the execution of HTTF experiments. An agreement in prediction of temperature trends but challenges reproducing HTTF temperatures within measurement uncertainty is consistent with previous analyses of HTTF in the literature. Future RELAP5-3D validation activities centered around HTTF may be able to provide greater insight into the code’s capabilities for HTGR modeling with a more finely nodalized model.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Planck 2018 results: III. High frequency instrument data processing and frequency maps

This paper presents the High Frequency Instrument (HFI) data processing procedures for the Planck 2018 release. Major improvements in mapmaking have been achieved since the previous Planck 2015 release, many of which were used and described already in an intermediate paper dedicated to the Planck polarized data at low multipoles. These improvements enabled the first significant measurement of the reionization optical depth parameter using Planck-HFI data. This paper presents an extensive analysis of systematic effects, including the use of end-to-end simulations to facilitate their removal and characterize the residuals. The polarized data, which presented a number of known problems in the 2015 Planck release, are very significantly improved, especially the leakage from intensity to polarization. Calibration, based on the cosmic microwave background (CMB) dipole, is now extremely accurate and in the frequency range 100-353 GHz reduces intensity-to-polarization leakage caused by calibration mismatch. The Solar dipole direction has been determined in the three lowest HFI frequency channels to within one arc minute, and its amplitude has an absolute uncertainty smaller than 0.35 μK, an accuracy of order 10 -4 . This is a major legacy from the Planck HFI for future CMB experiments. The removal of bandpass leakage has been improved for the main high-frequency foregrounds by extracting the bandpass-mismatch coefficients for each detector as part of the mapmaking process; these values in turn improve the intensity maps. This is a major change in the philosophy of "frequency maps", which are now computed from single detector data, all adjusted to the same average bandpass response for the main foregrounds. End-to-end simulations have been shown to reproduce very well the relative gain calibration of detectors, as well as drifts within a frequency induced by the residuals of the main systematic effect (analogue-to-digital convertor non-linearity residuals). Using these simulations, we have been able to measure and correct the small frequency calibration bias induced by this systematic effect at the 10 -4 level. There is no detectable sign of a residual calibration bias between the first and second acoustic peaks in the CMB channels, at the 10 -3 level.

79 ASTRONOMY AND ASTROPHYSICS↗

The SRG/eROSITA All-Sky Survey: Dark Energy Survey year 3 weak gravitational lensing by eRASS1 selected galaxy clusters

Context. Number counts of galaxy clusters across redshift are a powerful cosmological probe if a precise and accurate reconstruction of the underlying mass distribution is performed – a challenge called mass calibration. With the advent of wide and deep photometric surveys, weak gravitational lensing (WL) by clusters has become the method of choice for this measurement. Aims. We measured and validated the WL signature in the shape of galaxies observed in the first three years of the Dark Energy Survey (DES Y3) caused by galaxy clusters and groups selected in the first all-sky survey performed by SRG (Spectrum Roentgen Gamma)/eROSITA (eRASS1). These data were then used to determine the scaling between the X-ray photon count rate of the clusters and their halo mass and redshift. Methods. We empirically determined the degree of cluster member contamination in our background source sample. The individual cluster shear profiles were then analyzed with a Bayesian population model that self-consistently accounts for the lens sample selection and contamination and includes marginalization over a host of instrumental and astrophysical systematics. To quantify the accuracy of the mass extraction of that model, we performed mass measurements on mock cluster catalogs with realistic synthetic shear profiles. This allowed us to establish that hydrodynamical modeling uncertainties at low lens redshifts (z < 0.6) are the dominant systematic limitation. At high lens redshift, the uncertainties of the sources’ photometric redshift calibration dominate. Results. With regard to the X-ray count rate to halo mass relation, we determined its amplitude, its mass trend, the redshift evolution of the mass trend, the deviation from self-similar redshift evolution, and the intrinsic scatter around this relation. Conclusions. The mass calibration analysis performed here sets the stage for a joint analysis with the number counts of eRASS1 clusters to constrain a host of cosmological parameters. We demonstrate that WL mass calibration of galaxy clusters can be performed successfully with source galaxies whose calibration was performed primarily for cosmic shear experiments, opening the way for the cluster cosmological exploitation of future optical and NIR surveys like Euclid and LSST.

79 ASTRONOMY AND ASTROPHYSICS↗

AWSD reactive flow model for PBX 9404

An Arrhenius–Wescott–Stewart–Davis (AWSD) reactive flow model for high explosive PBX 9404 is developed. We specifically calibrate an AWSD model for PBX 9404 by fitting equations of state for reactants and detonation products to the results of thermochemical calculations and to experimental data from multiple sources. The calibrated equations of state are then coupled with an Arrhenius rate law based on shock temperature that describes the reaction progress during PBX 9404 detonation. The parameter values in the rate law are calibrated to experimental gas-gun data and diameter effect results. The results of the calibrated AWSD model are in strong agreement with available experimental data for PBX 9404. A similar level of agreement between predicted and experimental results is observed when the calibrated model is validated on data that were not used in the model parameterization procedure. Our results illustrate that the AWSD model is capable of accurately describing the many important properties and observables in the reactive burn of PBX 9404. Because of the historical significance of PBX 9404 in high explosives research and its current use in aging studies, this work provides an important model of a legacy material, which can be used to make comparisons to new high explosive formulations.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Robust and scalable uncertainty estimation with conformal prediction for machine-learned interatomic potentials

Abstract Uncertainty quantification (UQ) is important to machine learning (ML) force fields to assess the level of confidence during prediction, as ML models are not inherently physical and can therefore yield catastrophically incorrect predictions. Established a-posteriori UQ methods, including ensemble methods, the dropout method, the delta method, and various heuristic distance metrics, have limitations such as being computationally challenging for large models due to model re-training. In addition, the uncertainty estimates are often not rigorously calibrated. In this work, we propose combining the distribution-free UQ method, known as conformal prediction (CP), with the distances in the neural network’s latent space to estimate the uncertainty of energies predicted by neural network force fields. We evaluate this method (CP+latent) along with other UQ methods on two essential aspects, calibration, and sharpness, and find this method to be both calibrated and sharp under the assumption of independent and identically-distributed (i.i.d.) data. We show that the method is relatively insensitive to hyperparameters selected, and test the limitations of the method when the i.i.d. assumption is violated. Finally, we demonstrate that this method can be readily applied to trained neural network force fields with traditional and graph neural network architectures to obtain estimates of uncertainty with low computational costs on a training dataset of 1 million images to showcase its scalability and portability. Incorporating the CP method with latent distances offers a calibrated, sharp and efficient strategy to estimate the uncertainty of neural network force fields. In addition, the CP approach can also function as a promising strategy for calibrating uncertainty estimated by other approaches.

74 ATOMIC AND MOLECULAR PHYSICS↗

Evaluating Probabilistic Deep Learning Methods for Uncertainty Quantification of Precipitation Bias Correction

Climate models often exhibit biases in their precipitation predictions, particularly underestimating high-intensity events and overestimating low precipitation. Deep learning approaches offer promising solutions, but their epistemic uncertainty associated with a deep learning–based bias correction method has not previously been quantified for reliable downstream climate impact studies. While methods for capturing the epistemic uncertainty in deep learning frameworks exist, there is currently no consensus on the best method. In this work, we compare three uncertainty quantification (UQ) methods—Deep Ensembles (DEns), Monte Carlo Dropout (MCD), and Flipout—by assessing the reliability of their uncertainty estimates using standard measures such as sharpness and calibration. These UQ methods are applied to an existing deep learning precipitation bias correction model known as UFNet: a coupled U-Net and fully connected neural network. The methods utilized to assess the models’ uncertainties are 1) calibration, which ensures that the expected probabilities of the model align with reality and 2) sharpness, which is a measure of the precision of the model’s probabilistic predictions. Of the three UQ methods evaluated, the DEns and MCD methods demonstrated the best-calibrated performance (expected calibration error of 0.36 and 0.35, respectively), compared to Flipout (0.58). In contrast, Flipout had the sharpest predictions and the highest metric performance in bias correcting precipitation—especially for higher-order moments such as kurtosis with a spatial correlation of 72% compared to 32% and 55% spatial correlation for DEns and MCD, respectively. Of the three UQ methods, MCD was found to be the most suitable method for UQ purposes based on its calibration, sharpness, and computational requirements.

Bayesian methods↗

Total metals & anion concentration data; Slate River floodplain, Crested Butte, CO; May 2020-September 2020

This data package includes processed and undiluted measurements for metal and anion concentrations from pore water (groundwater) samples from the Slate River floodplain of Crested Butte, CO, a focus field site for the SLAC Floodplain Hydro-Biogeochemistry SFA. The data was generated as part of the work targeting the overarching research question for the SLAC SFA: How do ubiquitous subsurface interfaces mediate molecular-scale biogeochemical processes and groundwater quality in floodplains and watersheds? Samples were collected between May and September of 2020. These measurements were all recorded at the Arizona Laboratory for Emerging Contaminants (ALEC) at the University of Arizona located in Tucson, AZ. Groundwater samples were extracted from a network of installed rhizon (Rhizosphere Research Products, part no. 19.60.21F, 0.6 micrometer mesh size) and piezometer wells within the river floodplain. All water samples were shaded from sun exposure during extraction from the subsurface and preserved at 4C until measured at ALEC.Analysis by ICP-MS:Measurements for total metals were made on the Agilent 7700x ICP-MS (for total metals) – Agilent Technologies, Santa Clara, CA.The analytical QA/QC protocol was adapted from US EPA Method 200.8 for analysis by ICP-MS. Calibration standards were prepared from multi-element stock solution (Sigma-Aldrich Multielement standard solution for ICP, St. Louis, MO) using matrix matched to sample solutions (either 2% HCl or HNO3 from AriStar Plus,grade acids from VWR Scientific). Calibration curves include at least 7 points with correlation coefficients > 0.995. The QC protocol includes a continuing calibration blank (CCB), a continuing calibration verification (CCV) solution and at least one quality control sample (QCS) to be analyzed just after calibration and again after every 12 samples and at the completion of the run. The QCS solutions are from an independent source, such as NIST SRM 1643e - Trace Elements in Water, or QCS solutions from High Purity Standards (Charleston, SC). Acceptable QC responses must be between 90 and 110% of the certified value. An internal standard (Rh) is added via on-line addition into the sample line using a mixing tee.Analysis by Ion Chromatography (Anions):The protocol follows Method 4110 in Standard Methods for Examination of Water and Wastewater.The instrument used is the Thermo Scientific Dionex ICS-6000 using AS+AG22 column set for anion analysis with isocratic method using sodium carbonate eluent. Detection is by chemical suppression of eluent conductivity. Quality control solutions and mixed analyte standards purchased from Inorganic Ventures, Christiansburg, VA.All files are in csv format.

54 ENVIRONMENTAL SCIENCES↗

Total metals, sulfur and organic carbon data; Slate River floodplain, Crested Butte, CO; March 2021-October 2021

This data package includes processed and undiluted measurements for metal, sulfur and organic carbon concentrations from pore water (groundwater) samples from the Slate River floodplain of Crested Butte, CO, a focus field site for the SLAC Floodplain Hydro-Biogeochemistry SFA. The data was generated as part of the work targeting the overarching research question for the SLAC SFA: How do ubiquitous subsurface interfaces mediate molecular-scale biogeochemical processes and groundwater quality in floodplains and watersheds? Samples were collected between March and October of 2021. These measurements were all recorded at the Environmental Measurements Facility (EM-1) at Stanford University in Stanford, CA. Groundwater samples were extracted from a network of installed rhizon (Rhizosphere Research Products, part no. 19.60.21F, 0.6 micrometer mesh size) and piezometer wells within the river floodplain. All water samples were shaded from sun exposure during extraction from the subsurface and preserved at 2C until measured at EM-1.Analysis by ICP-MS:Measurements for total metals were performed on an inductively coupled plasma optical emission spectrometer (ICP-OES; iCAP 6300, Thermo Scientific, Cambridge, U.K.). Calibration standards were prepared from the mulit element stock solution (Sigma-Aldrich Multielement standard for ICP, St. Louis, MO) using matrix matched to sample solutions (2% HNO3). Calibration curves included 5 points with correlation coefficients of >0.99. The QC protocol includes a continuing calibration blank and quality control samples that are analyzed just after calibration and again every 20 samples and at the completion of the run. Acceptable QC responses must be between 90-110% of the certified value. Analysis by Total Organic Carbon:Dissolved organic carbon concentrations were quantified on a total organic carbon (TOC) analyzer (TOC-L, Shimadzu, Kyoto, Japan) running the NPOC method. Standard curves were developed using an Organic Carbon Standard from RICCA Chemical Company (Arlington,TX). A series of 4 to 6 standards were automatically diluted by the instrument in a concentration range that spans that of the samples. A blank sample was run just after the calibration curve and at the end of the run. A QC sample was run every 25 samples. Acceptable QC responses must be between 90-110% of the certified value.All files are in csv format.

54 ENVIRONMENTAL SCIENCES↗

Geodyn Material Library: Pseudocap models for dry porous tocks

This report describes the second edition of the Pseudocap Strength models for porous rocks implemented in GEODYN material library. The first model was developed in 2007 and calibrated for concrete. Then, the model parameters were calibrated based on triaxial tests reported for limestones and sandstones of various porosities. In these models some key parameters were chosen as functions of the reference porosity,Φ. Since then multiple modifications were implemented in the model, therefore, it has been recalibrated for some common porous materials such as limestones, sandstones, alluvium, tuffs and granite. Two types of models are described in this repot. The first type (called Pseudocap Model or PM) is for rocks from a specific location. Parameters were calibrated for several specific geologic materials. The second type (called Generic Pseudocap Model or GPM) is useful for the sites where only basic information (rock type, porosity) is available. Generic models include built-in correlations between porosities and other mechanical properties observed for certain rock types. The models of both types were validated by comparing not only to quasi-static triaxial tests for these materials but also to shock Hugoniot data and spherical explosion data for some materials. All models were derived in the frame of isotropic plasticity. They are designed to be used in explicit finite element/difference codes. Tangent stiffness tensor is not provided but can be calculated numerically for the model to be used in implicit finite element codes. For an isotropic material the stress can be decomposed into volumetric and deviatoric parts. The volumetric part is modeled using an Equation of state (EOS) which calculates the pressure and the bulk sound speed as functions of the internal specific energy and density. Here a simple, Mie-Gruneisen EOS is presented, but tabulated EOS (LEOS) provided by the library can be used as well. The stress is limited by the yield surface which depends on three invariants of the stress tensor and specific internal energy. In addition, to capture the strain-rate dependence a simple multiplier is used for the yield surface which depends on the equivalent plastic strain rate. The failure surface (the ultimate yield, Y f , defined later) is chosen in the Hoek-Brown form, commonly used in rock mechanics. It includes measurable parameters such as Unconfined Compressive Strength (UCS) as well as scale parameters characterizing the quality of the rock such as GSI (Geologic Strength Index). Thus, even though the model is calibrated for small samples it offers a way to extrapolate the strength to the field scale using geological characterization of the rock mass. The model captures effects of brittle-ductile transition in rocks by introducing a cap multiplier to the yield function. The rate of dilatancy (bulking) is proportional to the slope of the yield surface affected by the cap. Therefore, it takes place only at low confinements when the pressure is less than the brittle-ductile transition pressure, P BD . On the contrary, the porous compaction takes place at pressures higher than P BD . The cap moves as the porosity is compacted or new porosity is generated due to dilatancy. The porous compaction is modeled using an evolution equation which includes deviatoric stress so that the onset of compaction corresponds to the cap surface. The model captures effects of shear-enhanced compaction which is an important for porous rocks. Section 2 describes the modeling framework and Section 3 presents the model calibration procedure. Section 4 compares experimental data for various rocks versus model predictions. The model parameters used for this comparison are given in Appendix. The files with material constants are available with the latest GEODYN material library distribution.

58 GEOSCIENCES↗

Development of a hybrid neural network and transfer learning model for optimized ICP-MS/MS operation

Correct function and calibration of instrumentation is a crucial assumption for any scientific experiment. One such instrument, tandem inductively coupled plasma mass spectrometer (ICP-MS/MS), has in-depth calibration settings that range across 30+ different parameters, making it difficult to determine optimal conditions without expertise and some degree of trial and error. Often, these settings are hand-tuned, a time-intensive process prone to local maxima and human error. While some automation is available, the automation also may favor local optimizations over a global optimum. In addition to these difficulties, day to day instrument variability can further complicate the calibration process. We propose a solution to this problem as a machine learning (ML) algorithm that learns how each parameter helps determine the calibration sensitivity across several elements, and re-weights parameters over time as instrument variability changes (e.g., a global neural network (NN) with a time-dependent transfer learning (TL) component). This model would be able to generate a surface of predicted calibration sensitivities and their respective parameters, and a simple multivariate algorithm would be able to pull out the optimum results with the settings associated with them. Here-in, we describe our initial findings in working towards this goal, including data extraction from historical files, exploratory data analysis, and some initial model building to better describe the data and the feasibility of our goal.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

NREL Pyrheliometer Comparisons: September 23 - September 28, 2023 (NPC-2023)

Accurate measurements of direct normal (beam) solar irradiance from pyrheliometers are important for developing and deploying solar energy conversion systems, for improving our understanding of Earth's energy budget for climate change studies, and for other science and technology applications involving solar flux. Providing these measurements places many demands on the quality system used by the operator of commercially available radiometers. Maintaining accurate radiometer calibrations that are traceable to an international standard is the first step in producing research-quality solar irradiance measurements. In 1977, the World Meteorological Organization (WMO) established the World Radiometric Reference (WRR) as the international standard for the measurement of direct normal solar irradiance (Frohlich 1991). The WRR is an internationally recognized, detector-based measurement standard determined by the collective performance of six electrically self-calibrated absolute cavity radiometers comprising the World Standard Group (WSG). Various countries, including the United States, have contributed these specialized radiometers to the Physikalisch-Meteorologisches Observatorium Davos - World Radiation Center (PMOD/WRC) to establish the WSG. As with all measurement systems, Absolute Cavity Radiometers (ACR) are subject to performance changes over time. Therefore, PMOD/WRC in Davos, Switzerland, hosts an quinquennial International Pyrheliometer Comparison (IPC) event for transferring the WRR to participating radiometers by invitation. The National Renewable Energy Laboratory (NREL) has represented the U.S. Department of Energy (DOE) in each IPC since 1980. And NREL has developed and maintained a select group of absolute cavity radiometers with direct calibration traceability to the WRR, and it uses these reference instruments to calibrate pyrheliometers and pyranometers using the International Organization for Standardization (ISO) 17025-accredited Broadband Outdoor Radiometer Calibration (BORCAL) process (Reda et al. 2008). To fill the gap between each IPC, NREL pyrheliometer comparisons (NPCs) are held annually at the Solar Radiation Research Laboratory (SRRL) in Golden, Colorado. Open to all ACR owners and operators, each NPC provides an opportunity to determine the unique WRR transfer factor (WRR-TF) for each participating pyrheliometer. By adjusting all subsequent pyrheliometer measurements by the appropriate WRR-TF, the solar irradiance data are traceable to the WRR.

14 SOLAR ENERGY↗

Magnification Determination for AGHCF Metallographic Images

Metallographic images generated in the Alpha Gamma Hot Cell Facility (AGHCF) have been used for quantitative and qualitative characterization of irradiated metallic fuel pins. Individual high-magnification images (micrographs) contained in AGHCF file folders and experimental notebooks are in the form of polaroid photographs labeled with AGHCF identification number, magnification, and surface condition (as-polished or etched). Low magnification composite images (photomosaics) are also available for fuel cross sections, for radial strips from the fuel center to the cladding outer diameter, and for circumferential strips of the cladding and outer fuel region. The individual images do not have scale bars. Only a few of the composite images contain scale bars. The purpose of this work is to describe and apply methods for checking the magnification (50X to 500X) of individual images and for determining the magnification (~25X to ~100X) of composite images. The metallographic images used to verify and/or determine magnification were generated during the 1989 to 1993 timeframe for cross sections of U-10Zr/HT9 fuel rods irradiated in EBR-II and for cross sections of irradiated U-10Zr/HT9 fuel-rod samples following elevated-temperature tests conducted in the out-of-pile AGHCF Fuel Behavior Test Apparatus (FBTA). Procedures are documented in the AGHCF Operations Manual for preparation of metallographic samples, for calibration verification, and for constructing composites from individual images. Calibration verification of magnification was performed at least semiannually. One standard used for calibration verification was a glass slide with vertical lines indicating distances of 1 mm, 0.1 mm and 0.01mm. Guidance is provided in the current work for determining magnification from images of the standard. In addition to the periodic calibration verification, consistency checks are recommended to verify the magnification of images taken between the routine calibration verifications. For cladding samples with or without significant fuel-cladding chemical interaction (FCCI), images taken at different magnifications (e.g., 150X and 200X) of the unaffected cladding thickness can be compared. This process is independent of changes in cladding thickness due to swelling and creep. For images taken at only one magnification of cladding regions with no FCCI, the cladding thickness determined from the images may be compared to the nominal as-built cladding thickness (15.0 ± 0.5 mils for examples used in current work)). This procedure works best for cladding that has not experienced significant swelling and/or creep (e.g., ≤2% circumferential strain at the cladding outer surface). Composite images were constructed by pasting together higher magnification images and photographing the composite to generate a negative from which the hard-copy photograph was developed. The primary purpose of the composite images was to identify interesting areas of the fuel and cladding for imaging at higher magnification. However, procedures are recommended in the current work for determining composite magnifications to allow quantitative characterization of the fuel. Composites are not recommended for determining cladding thickness or FCCI depth because magnifications are too low (generally ≤110X) and image contrast is low. Fuel cross-section composites were created by pasting together 50X or 75X images. The nominal magnification for the photographed fuel cross-section composites is 25.4X. A more precise magnification can be determined by comparing the average cladding outer diameter measured from the composite to the average cladding outer diameter measured by profilometry. Radial-strip composites were constructed by pasting together high-magnification (150X or 250X) images. The nominal magnification of radial-strip composites photographs is about 100X. A more precise method for determining the magnification of radial strips is to compare the cladding thick

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Multiplexing and Demultiplexing Signals for Radiography Application Using the Discrete Fourier Transform

Our goal is to develop an X-ray phase-contrast imaging system that can provide excellent soft tissue contrast of phase, attenuation, and small-angle scatter. We propose to replace the common system of G0, G1, and G2 gradings with a biprism array to replace the G1 grading and introduce a novel X-ray tube designed to replace the motion of the phase stepping grading G2. The proposed X-ray tube uses temporal multiplexing to provide simultaneous virtual “electronic phase stepping.” In this work the discrete Fourier transform is used to separate from the composite measurement individual X-ray phase contrast measurements sampled at different frequencies. The method performs a discrete Fourier transform of a composite refence sequence to obtain using the frequency amplitudes calibration factors needed to extract the X-ray phase contrast measurement amplitudes from the composite image. The composite reference sequence is the sum of the individual sequences, at different frequencies, with amplitudes of one. The method takes the discrete Fourier transform of this composite reference sequence; whereby, the amplitude of each frequency component is compared with the total sum of its stand-alone sequence amplitude. A calibration factor is determined so that the amplitude of this composite reference frequency times the calibration factor must equal the total sum of the sequence amplitude—the zero-frequency amplitude of the discrete Fourier transform of its stand-alone sequence. To demultiplex the composite measured signal these calibration factors are multiplied by the amplitudes of the frequency components of the discrete Fourier transform of the composite X-phase-contrast measurement to obtain the amplitude of each frequency encoded measurement. Using these calibration factors, we demonstrate with the discrete Fourier transform in Mathematica the extraction of individual images from a composite image that one would expect obtaining from our proposed new X-ray phase contrast imaging system. We then demonstrate as an example how using images from X-ray phase contrast data one can calculate phase, attenuation and the dark field images using grading phase step data supplied to use from Microworks, GmbH in Karlsruhe, Germany.

42 ENGINEERING↗