Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “bits”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

SU-D-BRC-07: System Design for a 3D Volumetric Scintillation Detector Using SCMOS Cameras

Purpose: The purpose of this project is to build a volumetric scintillation detector for quantitative imaging of 3D dose distributions of proton beams accurately in near real-time. Methods: The liquid scintillator (LS) detector consists of a transparent acrylic tank (20×20×20 cm{sup 3}) filled with a liquid scintillator that when irradiated with protons generates scintillation light. To track rapid spatial and dose variations in spot scanning proton beams we used three scientific-complementary metal-oxide semiconductor (sCMOS) imagers (2560×2160 pixels). The cameras collect optical signal from three orthogonal projections. To reduce system footprint two mirrors oriented at 45° to the tank surfaces redirect scintillation light to cameras for capturing top and right views. Selection of fixed focal length objective lenses for these cameras was based on their ability to provide large depth of field (DoF) and required field of view (FoV). Multiple cross-hairs imprinted on the tank surfaces allow for image corrections arising from camera perspective and refraction. Results: We determined that by setting sCMOS to 16-bit dynamic range, truncating its FoV (1100×1100 pixels) to image the entire volume of the LS detector, and using 5.6 msec integration time imaging rate can be ramped up to 88 frames per second (fps). 20 mm focal length lens provides a 20 cm imaging DoF and 0.24 mm/pixel resolution. Master-slave camera configuration enable the slaves to initiate image acquisition instantly (within 2 µsec) after receiving a trigger signal. A computer with 128 GB RAM was used for spooling images from the cameras and can sustain a maximum recording time of 2 min per camera at 75 fps. Conclusion: The three sCMOS cameras are capable of high speed imaging. They can therefore be used for quick, high-resolution, and precise mapping of dose distributions from scanned spot proton beams in three dimensions.

60 APPLIED LIFE SCIENCES↗

SU-D-BRB-05: Quantum Learning for Knowledge-Based Response-Adaptive Radiotherapy

Purpose: There is tremendous excitement in radiotherapy about applying data-driven methods to develop personalized clinical decisions for real-time response-based adaptation. However, classical statistical learning methods lack in terms of efficiency and ability to predict outcomes under conditions of uncertainty and incomplete information. Therefore, we are investigating physics-inspired machine learning approaches by utilizing quantum principles for developing a robust framework to dynamically adapt treatments to individual patient’s characteristics and optimize outcomes. Methods: We studied 88 liver SBRT patients with 35 on non-adaptive and 53 on adaptive protocols. Adaptation was based on liver function using a split-course of 3+2 fractions with a month break. The radiotherapy environment was modeled as a Markov decision process (MDP) of baseline and one month into treatment states. The patient environment was modeled by a 5-variable state represented by patient’s clinical and dosimetric covariates. For comparison of classical and quantum learning methods, decision-making to adapt at one month was considered. The MDP objective was defined by the complication-free tumor control (P{sup +}=TCPx(1-NTCP)). A simple regression model represented state-action mapping. Single bit in classical MDP and a qubit of 2-superimposed states in quantum MDP represented the decision actions. Classical decision selection was done using reinforcement Q-learning and quantum searching was performed using Grover’s algorithm, which applies uniform superposition over possible states and yields quadratic speed-up. Results: Classical/quantum MDPs suggested adaptation (probability amplitude ≥0.5) 79% of the time for splitcourses and 100% for continuous-courses. However, the classical MDP had an average adaptation probability of 0.5±0.22 while the quantum algorithm reached 0.76±0.28. In cases where adaptation failed, classical MDP yielded 0.31±0.26 average amplitude while the quantum approach averaged a more optimistic 0.57±0.4, but with high phase fluctuations. Conclusion: Our results demonstrate that quantum machine learning approaches provide a feasible and promising framework for real-time and sequential clinical decision-making in adaptive radiotherapy.

60 APPLIED LIFE SCIENCES↗

SU-F-I-70: Investigation of Gafchromic EBT3 Film Energy Dependence Using Proton, Photon, and Electron Beams

Purpose: To investigate the energy dependence of Gafchromic EBT3 film over a range of clinically used proton, photon and electron energies. Methods: Proton beam energies of 117 and 204 MeV, corresponding respectively to ranges in water of 10 cm and 27 cm from a Mevion S250 double scatter system unit were used. Electron energies of 6 and 20 MeV and photon energies of 6 and 18 MV from a Varian Clinac 21EX Linac were used. Two pieces of film (5×5 cm{sup 2}) were irradiated sequentially for doses of 100, 500, and 1000 cGy for all energies and modalities. Films were placed on the central beam axis for a 10×10 cm{sup 2} field size in the middle of spread out Bragg peak (SOBP) for proton and in respective dmax for photon and electron energies. Films were scanned on a flatbed Epson Expression 10000 XL scanner on the central region of the scanning window using 48-bit, 300 dpi, and landscape orientation after 48 hours post-irradiation of film to account for optical density (OD) stabilization. Film analysis of the red channel was performed using ImageJ 1.48v (National Institutes of Health). Results: The energy dependency of EBT3 among all energies and modalities for all doses studied was small within measurement uncertainties (1σ = ± 4.1%). The mean net OD in red channel for films receiving the same dose in the same energy modality had standard deviations within 0.9% for photons, 4.9% for electrons and 1.8% for protons. It was observed that film pieces were activated during proton irradiation, e.g., 7 mR/hr at surface after 30 minutes of irradiation, lasting for 2 hours post irradiation. Conclusion: EBT3 energy dependency was evaluated for clinically used proton, photon, and electron energies. The film self-activation may have contributed to fog and negligible dose.

60 APPLIED LIFE SCIENCES↗

SU-F-T-180: Evaluation of a Scintillating Screen Detector for Proton Beam QA and Acceptance Testing

Purpose: To test the performance of a commercial scintillating screen detector for acceptance testing and Quality Assurance of a proton pencil beam scanning system. Method: The detector (Lexitek DRD 400) has 40cm × 40cm field, uses a thin scintillator imaged onto a 16-bit scientific CCD with ∼0.5mm resolution. A grid target and LED illuminators are provided for spatial calibration and relative gain correction. The detector mounts to the nozzle with micron precision. Tools are provided for image processing and analysis of single or multiple Gaussian spots. Results: The bias and gain of the detector were studied to measure repeatability and accuracy. Gain measurements were taken with the LED illuminators to measure repeatability and variation of the lens-CCD pair as a function with f-stop. Overall system gain was measured with a passive scattering (broad) beam whose shape is calibrated with EDR film placed in front of the scintillator. To create a large uniform field, overlapping small fields were recorded with the detector translated laterally and stitched together to cover the full field. Due to the long exposures required to obtain multiple spills of the synchrotron and very high detector sensitivity, borated polyethylene shielding was added to reduce direct radiation events hitting the CCD. Measurements with a micro ion chamber were compared to the detector’s spot profile. Software was developed to process arrays of Gaussian spots and to correct for radiation events. Conclusion: The detector background has a fixed bias, a small component linear in time, and is easily corrected. The gain correction method was validated with 2% accuracy. The detector spot profile matches the micro ion chamber data over 4 orders of magnitude. The multiple spot analyses can be easily used with plan data for measuring pencil beam uniformity and for regular QA comparison.

60 APPLIED LIFE SCIENCES↗

SU-F-T-583: Comparison of EBT3 Radiochromic Film Densitometry with Narrow Bandwidth LED Source in Point, Slot and Full Aperture Geometries

Purpose: Film densitometers optimized for radiochromic EBT3 film are not commercially available and flatbed document scanners are limited by broad spectral overlap of the red green and blue channels and polarization effects. Non-polarized, narrow bandwith, intensity stabilized light emitting diode (LED) light sources were constructed and transmission measurements compared for point, slot and full aperture geometries. Methods: LED’s with 10 nm bandwidths were focused to 1 mm spots for point scanning. The LED’s back-illuminated a 6 mm diameter diffuser near the focal point of a 25 cm diameter Fresnel lens for slot and full aperture transmission imaging. Films were located at the aperture plane, 15 cm from the lens and imaged with a 16 bit digital camera with 50 mm lens. Sheets, 10×8 cm, were irradiated to 25 Gy with a 4×4 cm 6 MV photon beam. Transmission measurements with a 633nm, linearly polarized laser were used as lowacceptance angle reference geometry. Results: LED intensity stabilized to <1% within one minute of startup. The useful transmission range increased as the acceptance angle decreased, laser(∼2%)> spot(∼3%)> slot(∼5%)> full aperture(∼10%). The Fresnel lens introduced a 4-fold polarization symmetry that increased radially causing a 2% change in transmission at 10 cm from the optic axis for EBT3 film. Polarized spot densitometer and laser transmission were similar. Conclusion: Spectrally filtered LED sources were effective for transmission measurements of radiochromic films. Because of polarization sensitivity of EBT3 film, the scanning spot geometry is the most general for measuring unpolarised transmission of larger film sizes, ie > 15×15 cm. Due to EBT3 film scatter, spot scanning should provide the most accurate profiles of high dose gradients, for a given acceptance angle. The spot scanning densitometer provided useful transmission to ∼5, 25, >25 Gy with 635, 590 and 530 nm light respectively.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

TU-AB-BRC-10: Modeling of Radiotherapy Linac Source Terms Using ARCHER Monte Carlo Code: Performance Comparison of GPU and MIC Computing Accelerators

Purpose: (1) To perform phase space (PS) based source modeling for Tomotherapy and Varian TrueBeam 6 MV Linacs, (2) to examine the accuracy and performance of the ARCHER Monte Carlo code on a heterogeneous computing platform with Many Integrated Core coprocessors (MIC, aka Xeon Phi) and GPUs, and (3) to explore the software micro-optimization methods. Methods: The patient-specific source of Tomotherapy and Varian TrueBeam Linacs was modeled using the PS approach. For the helical Tomotherapy case, the PS data were calculated in our previous study (Su et al. 2014 41(7) Medical Physics). For the single-view Varian TrueBeam case, we analytically derived them from the raw patient-independent PS data in IAEA’s database, partial geometry information of the jaw and MLC as well as the fluence map. The phantom was generated from DICOM images. The Monte Carlo simulation was performed by ARCHER-MIC and GPU codes, which were benchmarked against a modified parallel DPM code. Software micro-optimization was systematically conducted, and was focused on SIMD vectorization of tight for-loops and data prefetch, with the ultimate goal of increasing 512-bit register utilization and reducing memory access latency. Results: Dose calculation was performed for two clinical cases, a Tomotherapy-based prostate cancer treatment and a TrueBeam-based left breast treatment. ARCHER was verified against the DPM code. The statistical uncertainty of the dose to the PTV was less than 1%. Using double-precision, the total wall time of the multithreaded CPU code on a X5650 CPU was 339 seconds for the Tomotherapy case and 131 seconds for the TrueBeam, while on 3 5110P MICs it was reduced to 79 and 59 seconds, respectively. The single-precision GPU code on a K40 GPU took 45 seconds for the Tomotherapy dose calculation. Conclusion: We have extended ARCHER, the MIC and GPU-based Monte Carlo dose engine to Tomotherapy and Truebeam dose calculations.

60 APPLIED LIFE SCIENCES↗

TU-D-207B-02: Delta-Radiomics: The Prognostic Value of Therapy-Induced Changes in Radiomics Features for Stage III Non-Small Cell Lung Cancer Patients

Purpose: To determine how radiomics features change during radiation therapy and whether those changes (delta-radiomics features) can improve prognostic models built with clinical factors. Methods: 62 radiomics features, including histogram, co-occurrence, run-length, gray-tone difference, and shape features, were calculated from pretreatment and weekly intra-treatment CTs for 107 stage III NSCLC patients (5–9 images per patient). Image preprocessing for each feature was determined using the set of pretreatment images: bit-depth resample and/or a smoothing filter were tested for their impact on volume-correlation and significance of each feature in univariate cox regression models to maximize their information content. Next, the optimized features were calculated from the intratreatment images and tested in linear mixed-effects models to determine which features changed significantly with dose-fraction. The slopes in these significant features were defined as delta-radiomics features. To test their prognostic potential multivariate cox regression models were fitted, first using only clinical features and then clinical+delta-radiomics features for overall-survival, local-recurrence, and distant-metastases. Leave-one-out cross validation was used for model-fitting and patient predictions. Concordance indices(c-index) and p-values for the log-rank test with patients stratified at the median were calculated. Results: Approximately one-half of the 62 optimized features required no preprocessing, one-fourth required smoothing, and one-fourth required smoothing and resampling. From these, 54 changed significantly during treatment. For overall-survival, the c-index improved from 0.52 for clinical factors alone to 0.62 for clinical+delta-radiomics features. For distant-metastases, the c-index improved from 0.53 to 0.58, while for local-recurrence it did not improve. Patient stratification significantly improved (p-value<0.05) for overallsurvival and distant-metastases when delta-radiomics features were included. The delta-radiomics versions of autocorrelation, kurtosis, and compactness were selected most frequently in leave-one-out iterations. Conclusion: Weekly changes in radiomics features can potentially be used to evaluate treatment response and predict patient outcomes. High-risk patients could be recommended for dose escalation or consolidation chemotherapy. This project was funded in part by grants from the National Cancer Institute (NCI) and the Cancer Prevention Research Institute of Texas (CPRIT).

60 APPLIED LIFE SCIENCES↗

Tunable and laser-reconfigurable 2D heterocrystals obtained by epitaxial stacking of crystallographically incommensurate Bi 2 Se 3 and MoS 2 atomic layers

Vertical stacking is widely viewed as a promising approach for designing advanced functionalities using two-dimensional (2D) materials. Combining crystallographically commensurate materials in these 2D stacks has been shown to result in rich new electronic structure, magnetotransport, and optical properties. In this context, vertical stacks of crystallographically incommensurate 2D materials with well-defined crystallographic order are a counterintuitive concept and, hence, fundamentally intriguing. We show that crystallographically dissimilar and incommensurate atomically thin MoS 2 and Bi 2 Se 3 layers can form rotationally aligned stacks with long-range crystallographic order. Our first-principles theoretical modeling predicts heterocrystal electronic band structures, which are quite distinct from those of the parent crystals, characterized with an indirect bandgap. Experiments reveal striking optical changes when Bi 2 Se 3 is stacked layer by layer on monolayer MoS 2 , including 100% photoluminescence (PL) suppression, tunable transmittance edge (1.1→0.75 eV), suppressed Raman, and wide-band evolution of spectral transmittance. Disrupting the interface using a focused laser results in a marked the reversal of PL, Raman, and transmittance, demonstrating for the first time that in situ manipulation of interfaces can enable “reconfigurable” 2D materials. We demonstrate submicrometer resolution, “laser-drawing” and “bit-writing,” and novel laser-induced broadband light emission in these heterocrystal sheets.

36 MATERIALS SCIENCE↗

Provably secure and high-rate quantum key distribution with time-bin qudits

The security of conventional cryptography systems is threatened in the forthcoming era of quantum computers. Quantum key distribution (QKD) features fundamentally proven security and offers a promising option for quantum-proof cryptography solution. Although prototype QKD systems over optical fiber have been demonstrated over the years, the key generation rates remain several orders of magnitude lower than current classical communication systems. In an effort toward a commercially viable QKD system with improved key generation rates, we developed a discrete-variable QKD system based on time-bin quantum photonic states that can generate provably secure cryptographic keys at megabit-per-second rates over metropolitan distances. We use high-dimensional quantum states that transmit more than one secret bit per received photon, alleviating detector saturation effects in the superconducting nanowire single-photon detectors used in our system that feature very high detection efficiency (of more than 70%) and low timing jitter (of less than 40 ps). Our system is constructed using commercial off-the-shelf components, and the adopted protocol can be readily extended to free-space quantum channels. In conclusion, the security analysis adopted to distill the keys ensures that the demonstrated protocol is robust against coherent attacks, finite-size effects, and a broad class of experimental imperfections identified in our system.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Witnessing eigenstates for quantum simulation of Hamiltonian spectra

The efficient calculation of Hamiltonian spectra, a problem often intractable on classical machines, can find application in many fields, from physics to chemistry. We introduce the concept of an “eigenstate witness” and, through it, provide a new quantum approach that combines variational methods and phase estimation to approximate eigenvalues for both ground and excited states. This protocol is experimentally verified on a programmable silicon quantum photonic chip, a mass-manufacturable platform, which embeds entangled state generation, arbitrary controlled unitary operations, and projective measurements. Both ground and excited states are experimentally found with fidelities >99%, and their eigenvalues are estimated with 32 bits of precision. We also investigate and discuss the scalability of the approach and study its performance through numerical simulations of more complex Hamiltonians. This result shows promising progress toward quantum chemistry on quantum computers.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Attention to quantum complexity

The imminent era of error-corrected quantum computing demands robust methods to characterize quantum state complexity from limited, noisy measurements. We introduce the Quantum Attention Network (QuAN), a classical artificial intelligence (AI) framework leveraging attention mechanisms tailored for learning quantum complexity. Inspired by large language models, QuAN treats measurement snapshots as tokens while respecting permutation invariance. Combined with our parameter-efficient miniset self-attention block, this enables QuAN to access high-order moments of bit-string distributions and preferentially attend to less noisy snapshots. We test QuAN across three quantum simulation settings: driven hard-core Bose-Hubbard model, random quantum circuits, and toric code under coherent and incoherent noise. QuAN directly learns entanglement and state complexity growth from experimental computational basis measurements, including complexity growth in random circuits from noisy data. In regimes inaccessible to existing theory, QuAN unveils the complete phase diagram for noisy toric code data as a function of both noise types, highlighting AI’s transformative potential for assisting quantum hardware.

Kim, Hyejin [Cornell Univ., Ithaca, NY (United Sta↗

Scaling the Ion Trap Quantum Processor

Trapped atomic ions are standards for quantum information processing, serving as quantum memories, hosts of quantum gates in quantum computers and simulators, and nodes of quantum communication networks. Quantum bits based on trapped ions enjoy a rare combination of attributes: They have exquisite coherence properties, they can be prepared and measured with nearly 100% efficiency, and they are readily entangled with each other through the Coulomb interaction or remote photonic interconnects. The outstanding challenge is the scaling of trapped ions to hundreds or thousands of qubits and beyond, at which scale quantum processors can outperform their classical counterparts in certain applications. We review the latest progress and prospects in that effort, with the promise of advanced architectures and new technologies, such as microfabricated ion traps and integrated photonics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Hunting for Majoranas

Over the past decade, there have been considerable efforts to observe non-abelian quasiparticles in novel quantum materials and devices. These efforts are motivated by the goals of demonstrating quantum statistics of quasiparticles beyond those of fermions and bosons and of establishing the underlying science for the creation of topologically protected quantum bits. In this Review, we focus on efforts to create topological superconducting phases that host Majorana zero modes. We consider the lessons learned from existing experimental efforts, which are motivating both improvements to present platforms and the exploration of new approaches. Although the experimental detection of non-abelian quasiparticles remains challenging, the knowledge gained thus far and the opportunities ahead offer high potential for discovery and advances in this exciting area of quantum physics.

Science & Technology - Other Topics↗

A Novel Approach to Realize of All Optical Frequency Encoded Dibit Based XOR and XNOR Logic Gates Using Optical Switches with Simulated Verification

Since last few decades optics has already proved its strong potentiality for conducting parallel logic, arithmetic and algebraic operations due to its super-fast speed in communication and computation. So many different logical and sequential operations using all optical frequency encoding technique have been proposed by several authors. Here, we have keened out all optical dibit representation technique, which has the advantages of high speed operation as well as reducing the bit error problem. Exploiting this phenomenon, we have proposed all optical frequency encoded dibit based XOR and XNOR logic gates using the optical switches like add/drop multiplexer (ADM) and reflected semiconductor optical amplifier (RSOA). Also the operations of these gates have been verified through proper simulation using MATLAB (R2008a).

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

On Quantitative Determination of the Degree of Independence of Qubit Transformation by a Quantum Gate or Channel

A multiqubit channel (quantum gate) is considered. A procedure of calculating the distance from the quantum-gate matrix to the subspace of matrices, which are tensor products of the transformation matrices of qubit subsystems, is proposed. The value of this distance indicates the degree of independence of transformation of these qubit subsystems. The proposed approach is considered as applied to waveguide implementation of quantum bits.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Cryptographic robustness of a quantum cryptography system using phase-time coding

A cryptographic analysis is presented of a new quantum key distribution protocol using phase-time coding. An upper bound is obtained for the error rate that guarantees secure key distribution. It is shown that the maximum tolerable error rate for this protocol depends on the counting rate in the control time slot. When no counts are detected in the control time slot, the protocol guarantees secure key distribution if the bit error rate in the sifted key does not exceed 50%. This protocol partially discriminates between errors due to system defects (e.g., imbalance of a fiber-optic interferometer) and eavesdropping. In the absence of eavesdropping, the counts detected in the control time slot are not caused by interferometer imbalance, which reduces the requirements for interferometer stability.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Performance of a quantum key distribution protocol with dual-rail displaced photon states

We propose a scheme for a quantum key distribution (QKD) protocol with dual-rail displaced photon states. Displaced single-photon states with different amplitudes carry bit values of code that may be extracted, while coherent states carry nothing and only provide an inconclusive outcome. A real resource of single photons is used, involving imperfections associated with experimental technique that result in a photon state with an admixture of the vacuum state. The protocol is robust against the loss of a single photon and the inefficiency of the detectors. Pulses with large amplitudes, unlike the conventional QKD relying on faint laser pulses, are used that may approximate it to standard telecommunication and may show resistance to eaves-dropping even in settings with high attenuation. Information leakage to the eavesdropper is determined from comparison of the output distributions of the outcomes with ideal ones that are defined by two additional parameters accessible to only those send the pulses. Robustness to some possible eavesdropping attacks is shown.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Controlled quantum key distribution with three-photon polarization-entangled states via the collective noise channel

Using three-photon polarization-entangled GHZ states or W states, we propose controlled quantum key distribution protocols for circumventing two main types of collective noise, collective dephasing noise, or collective rotation noise. Irrespective of the number of controllers, a three-photon state can generate a one-bit secret key. The storage technique of quantum states is dispensable for the controller and the receiver, and it therefore allows performing the process in a more convenient mode. If the photon cost in a security check is disregarded, then the efficiency theoretically approaches unity.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗