Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “beam diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

Optical Stochastic Cooling Program at Fermilab's Integrable Optics Test Accelerator

Beam cooling enables an increase of peak and average luminosities and significantly expands the discovery potential of colliders. Optical Stochastic Cooling (OSC) is a high-bandwidth cooling technique that will advance the present state-of-the-art, stochastic-cooling rate by more than three orders of magnitude. A proof-of-principle demonstration with protons or heavy ions involves prohibitive costs, risks and technological challenges; however, exploration of OSC with electrons is a cost-effective alternative for studying the beam-cooling physics, optical systems and diagnostics. The ability to demonstrate OSC was a key requirement in the design of Fermilab's Integrable Optics Test Accelerator (IOTA) ring. The IOTA program will explore the physics and technology of OSC in amplified and non-amplified configurations. We also plan to investigate the cooling and manipulation of a single electron stored in the ring. The OSC apparatus is currently being fabricated, and installation will begin in the fall of 2019. In this contribution, we will describe the IOTA OSC program, the upcoming passive-OSC experimental runs and ongoing preparations for an amplified-OSC experiment

43 PARTICLE ACCELERATORS↗

Optical Stochastic Cooling Program at Fermilab's Integrable Optics Test Accelerator

Beam cooling enables an increase of peak and average luminosities and significantly expands the discovery potential of colliders. Optical Stochastic Cooling (OSC) is a high-bandwidth cooling technique that will advance the present state-of-the-art, stochastic-cooling rate by more than three orders of magnitude. A proof-of-principle demonstration with protons or heavy ions involves prohibitive costs, risks and technological challenges; however, exploration of OSC with electrons is a cost-effective alternative for studying the beam-cooling physics, optical systems and diagnostics. The ability to demonstrate OSC was a key requirement in the design of Fermilab's Integrable Optics Test Accelerator (IOTA) ring. The IOTA program will explore the physics and technology of OSC in amplified and non-amplified configurations. We also plan to investigate the cooling and manipulation of a single electron stored in the ring. The OSC apparatus is currently being fabricated, and installation will begin in the fall of 2019. In this contribution, we will describe the IOTA OSC program, the upcoming passive-OSC experimental runs and ongoing preparations for an amplified-OSC experiment.

43 PARTICLE ACCELERATORS↗

Can we estimate plasma density in ICP driver through electrical parameters in RF circuit?

To avoid regular maintenance, invasive plasma diagnostics with probes are not included in the inductively coupled plasma (ICP) based ITER Neutral Beam (NB) source design. Even non-invasive probes like optical emission spectroscopic diagnostics are also not included in the present ITER NB design due to overall system design and interface issues. As a result, negative ion beam current through the extraction system in the ITER NB negative ion source is the only measurement which indicates plasma condition inside the ion source. However, beam current not only depends on the plasma condition near the extraction region but also on the perveance condition of the ion extractor system and negative ion stripping. Nevertheless, inductively coupled plasma production region (RF driver region) is placed at distance (∼ 30cm) from the extraction region. Due to that, some uncertainties are expected to be involved if one tries to link beam current with plasma properties inside the RF driver. Plasma characterization in source RF driver region is utmost necessary to maintain the optimum condition for source operation. In this paper, a method of plasma density estimation is described, based on density dependent plasma load calculation.

43 PARTICLE ACCELERATORS↗

High Intensity Source of He Negative Ions

He- ion can be formed by an attachment of additional electron to the excited metastable 23S1 He atom. Electron affinity in this metastable He- ion is A=0.08 eV with excitation energy 19.8 eV. Production of He- ions is difficult because the formation probability is very small but destruction probability is very high. Efficiency of He- ions generation was improved by using of an alkali vapor targets for charge exchange He- sources. Low current He- beams were used in tandem accelerators for research and technological diagnostics (Rutherford scattering). The development of high-intensity high-brightness arc-discharge ion sources at the Budker Institute of Nuclear Physics (BINP) has opened up an opportunity for efficient production of more intense and more brighter He- beam which can be used for alpha particles diagnostics in a fusion plasma and for realization of a new type of a polarized 3He? ion source. This report discusses the high intense He- beams production and a polarized 3He? ion source based on the large difference of extra-electron auto-detachment lifetimes of the different 3He? ion hyperfine states.

43 PARTICLE ACCELERATORS↗

SU-F-T-561: Energy Dependence of a Scintillation Detector

Purpose: To investigate the response and dose rate dependence of a scintillation detector over a wide energy range. Methods: The energy dependence of W1 scintillation detector was tested with: 1) 50–225 keV beams generated by an animal irradiator, 2) a Leksell Gamma Knife Perfexion Co-60 source, 3) 6MV, 6FFF, 10FFF and 15MV photon beams, and 4) 6–20MeV electron beams from a linac. Calibrated linac beams were used to deliver 100 cGy to the detector at dmax in water under reference conditions. The gamma-knife measurement was performed in solid water (100 cGy with 16mm collimator). The low energy beams were calibrated with an ion chamber in air (TG-61), and the scintillation detector was placed at the same location as the ionization chamber during calibration. For the linac photon and electron beams, dose rate dependence was tested for 100–2400 and 100–800 MU/min. Results: The scintillation detector demonstrated strong energy dependence in the range of 50–225keV. The measured values were lower than the delivered dose and increased as the energy increased. Therapeutic photon beams showed energy independence with variations less than 1%. Therapeutic electron beams displayed the same sensitivity of ∼2–3% at their corresponding dmax depths. The change in dose-rate of photon and electron beams within the therapeutic energy range did not affect detector output (<0.5%). Measurements acquired with the gamma knife showed that the output data agreed with the delivered dose up to 3%. Conclusion: W1 scintillation detector output has a strong energy dependence in the diagnostic and orthovoltage energy range. Therapeutic photon beams exhibited energy independence with no observable dose-rate dependence. This study may aid in the implementation of a scintillation detector in QA programs by providing energy calibration factors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Application of dynamic displacement current for diagnostics of subnanosecond breakdowns in an inhomogeneous electric field

The breakdown of different air gaps at high overvoltages in an inhomogeneous electric field was investigated with a time resolution of up to 100 ps. Dynamic displacement current was used for diagnostics of ionization processes between the ionization wave front and a plane anode. It is demonstrated that during the generation of a supershort avalanche electron beam (SAEB) with amplitudes of {approx}10 A and more, conductivity in the air gaps at the breakdown stage is ensured by the ionization wave, whose front propagates from the electrode of small curvature radius, and by the dynamic displacement current between the ionization wave front and the plane electrode. The amplitude of the dynamic displacement current measured by a current shunt is 100 times greater than the SAEB. It is shown that with small gaps and with a large cathode diameter, the amplitude of the dynamic displacement current during a subnanosecond rise time of applied pulse voltage can be higher than 4 kA.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

OPERATIONAL EXPERIENCE WITH FAST FIBER-OPTIC BEAM LOSS MONITORS FOR THE ADVANCED PHOTON SOURCE STORAGE RING SUPERCONDUCTING UNDULATORS

Fast fiber-optic (FFO) beam loss monitors (BLMs) installed with the first two superconducting undulators (SCUs) in the Advanced Photon Source storage ring have proven to be a useful diagnostic for measuring deposited charge (energy) during rapid beam loss events. The first set of FFOBLMs were installed outside the cryostat of the short SCU, a 0.33-m long device, above and below the beam centerline. The second set are mounted with the first 1.1-mlong SCU within the cryostat, on the outboard and inboard sides of the vacuum chamber. The next 1.1-m-long SCU is scheduled to replace the short SCU later in 2016 and will be fitted with FFOBLMs in a manner similar to original 1.1-m device. The FFOBLMs were employed to set timing and voltage for the abort kicker (AK) system. The AK helps to prevent quenching of the SCUs during beam dumps [1] by directing the beam away from the SC magnet windings. The AK is triggered by the Machine Protection System (MPS). In cases when the AK fails to prevent quenching, the FFOBLMs show that losses often begin before detection by the MPS.

Dooling, J.↗

Controllable optical emission spectroscopy diagnostic system for analysis of process chemistries

Optical emission spectroscopy (OES) diagnostics have been employed for many years in plasma etch end point detection schemes. Unfortunately some newer process systems have much lower optical emission or limited optical access. To overcome such limitations, an OES diagnostic system making use of variable e-beam has been developed. That system is described and initial experimental results are presented. A strong correlation is observed between the optical emission intensity and e-beam current, a measurable electrical parameter. This correlation offers means to normalize optical signal and to be used as a feedback input to the electronics that control the plasma source. In addition there is a measurable response from the different lines due to energy of the electrons, indicating a new degree of freedom in the diagnostic that can be tapped for more precise analysis of end point.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

PERFORMANCE OF THE DIAGNOSTICS FOR NSLS-II LINAC COMMISSIONING

The National Synchrotron Light Source II (NSLS-II) is a state of the art 3-GeV third generation light source currently under construction at Brookhaven National Laboratory. The NSLS-II injection system consists of a 200 MeV linac, a 3-GeV booster synchrotron and associated transfer lines. The transfer lines not only provide a means to deliver the beam from one machine to another, they also provide a suite of diagnostics and utilities to measure the properties of the beam to be delivered. In this paper we discuss the suite of diagnostics that will be used to commission the NSLS-II linac and measure the beam properties. The linac to booster transfer line can measure the linac emittance with a three screens measurement or a quadrupole scan. Energy and energy spread are measured in a dispersive section. Total charge and charge uniformity are measured with wall current monitors in the linac and transformers in the transfer line. We show that the performance of the diagnostics in the transfer line will be sufficient to ensure the linac meets its specifications and provides a means of trouble shooting and studying the linac in future operation.

200 MeV linac↗

A flexible proton beam imaging energy spectrometer (PROBIES) for high repetition rate or single-shot high energy density (HED) experiments (invited)

The PROBIES diagnostic is a new, highly flexible, imaging and energy spectrometer designed for laser-accelerated protons. The diagnostic can detect low-mode spatial variations in the proton beam profile while resolving multiple energies on a single detector or more. When a radiochromic film stack is employed for “single-shot mode,” the energy resolution of the stack can be greatly increased while reducing the need for large numbers of films; for example, a recently deployed version allowed for 180 unique energy measurements spanning ~3 to 75 MeV with <0.4 MeV resolution using just 20 films vs 180 for a comparable traditional film and filter stack. When utilized with a scintillator, the diagnostic can be run in high-rep-rate (>Hz rate) mode to recover nine proton energy bins. Here, we also demonstrate a deep learning-based method to analyze data from synthetic PROBIES images with greater than 95% accuracy on sub-millisecond timescales and retrained with experimental data to analyze real-world images on sub-millisecond time-scales with comparable accuracy.

3D printing↗

Beam measurements using visible synchrotron light at NSLS2 storage ring

Visible Synchrotron Light Monitor (SLM) diagnostic beamline has been designed and constructed at NSLS2 storage ring, to characterize the electron beam profile at various machine conditions. Due to the excellent alignment, SLM beamline was able to see the first visible light when beam was circulating the ring for the first turn. The beamline has been commissioned for the past year. Besides a normal CCD camera to monitor the beam profile, streak camera and gated camera are used to measure the longitudinal and transverse profile to understand the beam dynamics. Measurement results from these cameras will be presented in this paper. A time correlated single photon counting system (TCSPC) has also been setup to measure the single bunch purity.

43 PARTICLE ACCELERATORS↗

Beam Meassurements Using Visible Synchrotron Light at NSLSII Storage Ring

Visible Synchrotron Light Monitor (SLM) diagnostic beamline has been designed and constructed at NSLS2 storage ring, to characterize the electron beam profile at various machine conditions. Thanks for the excellent alignment, SLM beamline was able to see the first visible light when beam was circulating the ring for the first turn. The beamline has been commissioned for the past year. Besides a normal CCD camera to monitor the beam profile, streak camera and gated camera are used to measure the longitudinal and transverse profile to understand the beam dynamics. Measurement results from these cameras will be present in this paper. A time correlated single photon counting system (TCSPC) has been setup and measures the single bunch purity using visible light, preliminary TCSPC measurement result will be presented as well.

36 MATERIALS SCIENCE↗

Magnetized Electron Source for JLEIC Electron Cooler

Bunched-beam electron cooling is a key feature of all proposed designs of the future electron-ion collider, and a requirement for achieving the specified collision luminosity. For the Jefferson Lab Electron Ion Collider (JLEIC), fast cooling of ion beams will be accomplished via so-called 'magnetized cooling' implemented using a recirculator ring that employs an energy recovery linac. In this contribution, we describe the production of magnetized electron beam using a compact 300 kV DC high voltage photogun with an inverted insulator geometry and alkali-antimonide photocathodes. Beam magnetization was assessed using a modest diagnostic beamline that includes YAG view screens for measuring the rotation angle of the electron beamlet passing through a narrow upstream slit. Magnetization characterization including drift emittance were measured for various gun bias voltages and laser spot sizes at the photocathode using 532 nm lasers with DC and RF time structure. With magnetized beam, photocathode lifetime at currents up to 28 mA CW was measured and high bunch charge up to 700 pC was demonstrated.

Mamun, Md Abdullah↗

Characterization of cross-section correction to charge exchange recombination spectroscopy rotation measurements using co- and counter-neutral-beam views

Measurements of rotation using charge exchange recombination spectroscopy can be affected by the energy dependence of the charge exchange cross section. On DIII-D, the associated correction to the rotation can exceed 100 km/s at high temperatures. In reactor-relevant low rotation conditions, the correction can be several times larger than the actual plasma rotation and therefore must be carefully validated. New chords have been added to the DIII-D CER diagnostic to view the counter-neutral-beam line. The addition of these views allows determination of the toroidal rotation without depending on detailed atomic physics calculations, while also allowing experimental characterization of the atomic physics. A database of rotation comparisons from the two views shows that the calculated cross-section correction can adequately describe the measurements, although there is a tendency for 'overcorrection'. In cases where accuracy better than about 15% is desired, relying on calculation of the cross-section correction may be insufficient.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Charge Diagnostics for Laser Plasma Accelerators

The electron energy dependence of a scintillating screen (Lanex Fast) was studied with sub-nanosecond electron beams ranging from 106 MeV to 1522 MeV at the Lawrence Berkeley National Laboratory Advanced Light Source (ALS) synchrotron booster accelerator. The sensitivity of the Lanex Fast decreased by 1% per 100 MeV increase of the energy. The linear response of the screen against the charge was verified with charge density and intensity up to 160 pC/mm{sup 2} and 0.4 pC/ps/mm{sup 2}, respectively. For electron beams from the laser plasma accelerator, a comprehensive study of charge diagnostics has been performed using a Lanex screen, an integrating current transformer, and an activation based measurement. The charge measured by each diagnostic was found to be within {+-}10%.

43 PARTICLE ACCELERATORS↗

Characteristics of a He{sup -} Beam Produced in Lithium Vapor

A test stand for the proof of principle experiments of He{sup 0} beam production has been constructed aiming at development of an alpha particle diagnostic system in next generation fusion reactors. The characteristics of a He{sup -} beam produced in Lithium vapor has been studied. With an increase in the vapor pressure in the cell, mitigation of space charge in a He{sup +} beam and bunching of a He{sup -} beam which travels part of the way with the He{sup +} beam have been observed.

43 PARTICLE ACCELERATORS↗

Measurement of ion beam profiles in a superconducting linac with a laser wire

A laser wire ion beam profile monitor system has been developed at the Spallation Neutron Source accelerator complex. The laser wire system uses a single laser source to measure the horizontal and vertical profiles of a pulsed hydrogen ion (H{sup -}) beam along a 230 m long superconducting linac, which accelerates H{sup -} from 200 MeV to 1 GeV. In this paper, we describe the laser optics requirement for the system, the performance of the profile measurement, and the effects of laser parameters on the measurement reliability. The result provides a practical guideline for the development of a large-scale, operational, laser-based diagnostics in accelerator facilities.

43 PARTICLE ACCELERATORS↗