Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Vertex”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

Simplex‐based model for nanoparticle grain identification in four‐dimensional scanning transmission electron microscopy data

Grain identification in polycrystalline nanoparticles, for example, determining which crystal phases are present at each spatial location, is fundamental to materials characterisation. This is particularly challenging when grains overlap extensively, as commonly occurs in four-dimensional scanning transmission electron microscopy (4D-STEM) datasets. We propose a simplex-based model (SBM) in which each simplex vertex represents the diffraction pattern (DP) of a pure grain, and the simplex edges and interior represent overlapping grains. Our SBM grain identification algorithm operates on the Bragg disk (BD) data matrix distilled from the 4D-STEM data to identify the grain membership at each scan position, together with a BD feature matrix whose columns represent the DPs for each constituent grain, which is important for identifying the crystal structure of each grain. We solve the model using a two-stage algorithm. In Stage 1, we adapt a linear mixing algorithm to estimate an initial BD feature matrix whose columns represent DPs of potentially overlapping grains. Our Stage 2 algorithm incorporates sparsity considerations to transform the initial BD feature matrix so that its columns represent DPs of pure grains. Using simulated datasets with various grain configurations, we demonstrate that SBM recovers both the BD feature matrix and membership maps more accurately than existing methods, even when a grain lacks any pure region and completely overlaps with other grains.

4D-STEM segmentation↗

Experimental and Numerical Analysis of Additively Manufactured Inconel 718 Coupons With Lattice Structure

Abstract In the present paper, two lattice geometries suitable for near surface and double wall cooling were developed and tested. The first type of unit cell consisted of six ligaments of 0.5 mm diameter joined at a common vertex near the middle. The second type of unit cell was derived from the first type by adding four mutually perpendicular ligaments in the middle plane. Two lattice configurations, referred to as L1 and L2, respectively, were obtained by repeating the corresponding unit cell in streamwise and spanwise directions in an inline fashion. Test coupons consisting of these lattice geometries embedded inside rectangular cooling channel with dimensions of 2.54 mm height, 38.07 mm width, and 38.1 mm in length were fabricated using Inconel 718 powder and selective laser sintering (SLS) process. The heat transfer and pressure drop performance was then evaluated using steady-state tests with constant wall temperature boundary condition and for channel Reynolds number ranging from 2800 to 15,000. The lattices depicted a higher heat transfer compared with a smooth channel and both the heat transfer and pressure drop increased with a decrease in the porosity from L1 to L2. Steady-state conjugate numerical results revealed formation of prominent vortical structures in the inter-unit cell spaces, which diverted the flow toward the top end wall and created an asymmetric heat transfer between the two end walls. In conclusion, these lattice structures provided an augmented heat transfer while favorably redistributing the coolant within channel.

Engineering↗

A hybrid electron and photon IMRT planning technique that lowers normal tissue integral patient dose using standard hardware

Purpose: To present a mixed electron and photon IMRT planning technique using electron beams with an energy range of 6-22 MeV and standard hardware that minimizes integral dose to patients for targets as deep as 7.5 cm. Methods: Ten brain cases, two lung, a thyroid, an abdominal, and a parotid case were planned using two planning techniques: a photon-only IMRT (IMRT) versus a mixed modality treatment (E + IMRT) that includes an enface electron beam and a photon IMRT portion that ensures a uniform target coverage. The electron beam is delivered using a regular cutout placed in an electron cone. The electron energy was chosen to provide a good trade-off between minimizing integral dose and generating a uniform, deliverable plan. The authors choose electron energies that cover the deepest part of PTV with the 65%-70% isodose line. The normal tissue integral dose, the dose for ring structures around the PTV, and the volumes of the 75%, 50%, and 25% isosurfaces were used to compare the dose distributions generated by the two planning techniques. Results: The normal tissue integral dose was lowered by about 20% by the E + IMRT plans compared to the photon-only IMRT ones for most studied cases. With the exception of lungs, the dose reduction associated to the E + IMRT plans was more pronounced further away from the target. The average dose ratio delivered to the 0-2 cm and the 2-4 cm ring structures for brain patients for the two planning techniques were 89.6% and 70.8%, respectively. The enhanced dose sparing away from the target for the brain patients can also be observed in the ratio of the 75%, 50%, and 25% isodose line volumes for the two techniques, which decreases from 85.5% to 72.6% and further to 65.1%, respectively. For lungs, the lateral electron beams used in the E + IMRT plans were perpendicular to the mostly anterior/posterior photon beams, generating much more conformal plans. Conclusions: The authors proved that even using the existing electron delivery hardware, a mixed electron/photon planning technique (E + IMRT) can decrease the normal tissue integral dose compared to a photon-only IMRT plan. Different planning approaches can be enabled by the use of an electron beam directed toward organs at risk distal to the target, which are still spared due the rapid dose fall-off of the electron beam. Examples of such cases are the lateral electron beams in the thoracic region that do not irradiate the heart and contralateral lung, electron beams pointed toward kidneys in the abdominal region, or beams treating brain lesions pointed toward the brainstem or optical apparatus. For brain, electron vertex beams can also be used without irradiating the whole body. Since radiation retreatments become more and more common, minimizing the normal tissue integral dose and the dose delivered to tissues surrounding the target, as enabled by E + IMRT type techniques, should receive more attention.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-C-18A-04: 3D Markerless Registration of Lung Based On Coherent Point Drift: Application in Image Guided Radiotherapy

Purpose: This study evaluated a new probabilistic non-rigid registration method called coherent point drift for real time 3D markerless registration of the lung motion during radiotherapy. Method: 4DCT image datasets Dir-lab (www.dir-lab.com) have been used for creating 3D boundary element model of the lungs. For the first step, the 3D surface of the lungs in respiration phases T0 and T50 were segmented and divided into a finite number of linear triangular elements. Each triangle is a two dimensional object which has three vertices (each vertex has three degree of freedom). One of the main features of the lungs motion is velocity coherence so the vertices that creating the mesh of the lungs should also have features and degree of freedom of lung structure. This means that the vertices close to each other tend to move coherently. In the next step, we implemented a probabilistic non-rigid registration method called coherent point drift to calculate nonlinear displacement of vertices between different expiratory phases. Results: The method has been applied to images of 10-patients in Dir-lab dataset. The normal distribution of vertices to the origin for each expiratory stage were calculated. The results shows that the maximum error of registration between different expiratory phases is less than 0.4 mm (0.38 SI, 0.33 mm AP, 0.29 mm RL direction). This method is a reliable method for calculating the vector of displacement, and the degrees of freedom (DOFs) of lung structure in radiotherapy. Conclusions: We evaluated a new 3D registration method for distribution set of vertices inside lungs mesh. In this technique, lungs motion considering velocity coherence are inserted as a penalty in regularization function. The results indicate that high registration accuracy is achievable with CPD. This method is helpful for calculating of displacement vector and analyzing possible physiological and anatomical changes during treatment.

60 APPLIED LIFE SCIENCES↗

Evaluation of potential internal target volume of liver tumors using cine-MRI

Purpose: Four-dimensional computed tomography (4DCT) is widely used for evaluating moving tumors, including lung and liver cancers. For patients with unstable respiration, however, the 4DCT may not visualize tumor motion properly. High-speed magnetic resonance imaging (MRI) sequences (cine-MRI) permit direct visualization of respiratory motion of liver tumors without considering radiation dose exposure to patients. Here, the authors demonstrated a technique for evaluating internal target volume (ITV) with consideration of respiratory variation using cine-MRI. Methods: The authors retrospectively evaluated six patients who received stereotactic body radiotherapy (SBRT) to hepatocellular carcinoma. Before acquiring planning CT, sagittal and coronal cine-MRI images were acquired for 30 s with a frame rate of 2 frames/s. The patient immobilization was conducted under the same condition as SBRT. Planning CT images were then acquired within 15 min from cine-MRI image acquisitions, followed by a 4DCT scan. To calculate tumor motion, the motion vectors between two continuous frames of cine-MRI images were calculated for each frame using the pyramidal Lucas–Kanade method. The target contour was delineated on one frame, and each vertex of the contour was shifted and copied onto the following frame using neighboring motion vectors. 3D trajectory data were generated with the centroid of the contours on sagittal and coronal images. To evaluate the accuracy of the tracking method, the motion of clearly visible blood vessel was analyzed with the motion tracking and manual detection techniques. The target volume delineated on the 50% (end-exhale) phase of 4DCT was translated with the trajectory data, and the distribution of the occupancy probability of target volume was calculated as potential ITV (ITV {sub Potential}). The concordance between ITV {sub Potential} and ITV estimated with 4DCT (ITV {sub 4DCT}) was evaluated using the Dice’s similarity coefficient (DSC). Results: The distance between blood vessel positions determined with motion tracking and manual detection was analyzed. The mean and SD of the distance were less than 0.80 and 0.52 mm, respectively. The maximum ranges of tumor motion on cine-MRI were 2.4 ± 1.4 mm (range, 1.0–5.0 mm), 4.4 ± 3.3 mm (range, 0.8–9.4 mm), and 14.7 ± 5.9 mm (range, 7.4–23.4 mm) in lateral, anterior–posterior, and superior–inferior directions, respectively. The ranges in the superior–inferior direction were larger than those estimated with 4DCT images for all patients. The volume of ITV {sub Potential} was 160.3% ± 13.5% (range, 142.0%–179.2%) of the ITV {sub 4DCT}. The maximum DSC values were observed when the cutoff value of 24.7% ± 4.0% (range, 20%–29%) was applied. Conclusions: The authors demonstrated a novel method of calculating 3D motion and ITV {sub Potential} of liver cancer using orthogonal cine-MRI. Their method achieved accurate calculation of the respiratory motion of moving structures. Individual evaluation of the ITV {sub Potential} will aid in improving respiration management and treatment planning.

60 APPLIED LIFE SCIENCES↗

SU-F-R-27: Use Local Shape Descriptor Based On Geodesic Distance to Predict Survival in Non-Small Cell Lung Cancer After Radiotherapy

Purpose: The shape of the Positron Emission Tomography (PET) image represents the heterogeneity of tumor growth in various directions, and thus could be associated with tumor malignancy. We have proposed a median geodesic distance (MGD) to represent the local complexity of the shape and use a normalized MGD (NMGD) to quantify the shape, and found a potential correlation of NMGD to survival in a 20-patient pilot study. This study was to verify the finding in a larger patient cohort. Methods: Geodesic distance of two vertices on a surface is defined as the shortest path on the surface connecting the two vertices. The MGD was calculated for each vertex on the surface to display the local complexity of the shape. The NMGD was determined as: NMGD = 100*standard deviation(MGDs)/mean(MGDs). We applied the NMGD to 40 NSCLC patients who were enrolled in prospective PET image protocols and received radiotherapy. Each patient had a pre-treatment PET scan with the resolution of 4mm*4mm*5mm. Tumors were contoured by a professional radiation oncologist and triangulation meshes were built up based on the contours. Results: The mean and standard deviation of NMGD was 6.4±3.0. The OS was 33.1±16.9 months for low NMGD group, and 15.4±15.6 months for the high NMGD group. The low NMGD group had significant better OS than the high NMGD group (p=0.0013). Conclusion: NMGD could be used as a shape biomarker to predict survival and the MGD could be combined with image texture in future to increase prediction accuracy. This study was supported by Award Number 1R01CA166948 from the NIH and National Cancer Institute.

60 APPLIED LIFE SCIENCES↗

SU-F-I-46: Optimizing Dose Reduction in Adult Head CT Protocols While Maintaining Image Quality in Postmortem Head Scans

Purpose: To optimize adult head CT protocol by reducing dose to an appropriate level while providing CT images of diagnostic quality. Methods: Five cadavers were scanned from the skull base to the vertex using a routine adult head CT protocol (120 kVp, 270 mA, 0.75 s rotation, 0.5 mm × 32 detectors, 70.8 mGy CTDIvol) followed by seven reduced-dose protocols with varying combinations of reduced tube current, reduced rotation time, and increased detectors with CTDIvol ranging from 38.2 to 65.6 mGy. Organ doses were directly measured with 21 OSL dosimeters placed on the surface and implanted in the head by a neurosurgeon. Two neuroradiologists assessed grey-white matter differentiation, fluid space, ventricular size, midline shift, brain mass, edema, ischemia, and skull fractures on a three point scale: (1) Unacceptable, (2) Borderline Acceptable, and (3) Acceptable. Results: For the standard scan, doses to the skin, lens of the eye, salivary glands, thyroid, and brain were 37.55 mGy, 49.65 mGy, 40.67 mGy, 4.63 mGy, and 27.33 mGy, respectively. Two cadavers had cerebral edema due to changing dynamics of postmortem effects, causing the grey-white matter differentiation to appear less distinct. Two cadavers with preserved grey-white matter received acceptable scores for all image quality features for the protocol with a CTDIvol of 57.3 mGy, allowing organ dose savings ranging from 34% to 45%. One cadaver allowed for greater dose reduction for the protocol with a CTDIvol of 42 mGy. Conclusion: Efforts to optimize scan protocol should consider both dose and clinical image quality. This is made possible with postmortem subjects, whose brains are similar to patients, allowing for an investigation of ideal scan parameters. Radiologists at our institution accepted scan protocols acquired with lower scan parameters, with CTDIvol values closer to the American College of Radiology’s (ACR) Achievable Dose level of 57 mGy.

60 APPLIED LIFE SCIENCES↗

SU-F-T-76: Total Skin Electron Therapy: An-End-To-End Examination of the Absolute Dosimetry with a Rando Phantom

Purpose: To examine and validate the absolute dose for total skin electron therapy (TSET) through an end-to-end test with a Rando phantom using optically stimulated luminescent dosimeters (OSLDs) and EBT3 radiochromic films. Methods: A Varian Trilogy linear accelerator equipped with the special procedure 6 MeV HDTSe- was used to perform TSET irradiations using a modified Stanford 6-dual-field technique. The absolute dose was calibrated using a Markus ion chamber at a reference depth of 1.3cm at 100 cm SSD with a field size of 36 × 36 cm at the isocenter in solid water slabs. The absolute dose was cross validated by a farmer ion chamber. Then the dose rate in the unit of cGy/Mu was calibrated using the Markus chamber at the treatment position. OSLDs were used to independently verify the dose using the calibrated dose rate. Finally, a patient treatment plan (200 cGy/cycle) was delivered in the QA mode to a Rando phantom, which had 16 pairs of OSLDs and EBT3 films taped onto its surface at different anatomical positions. The doses recorded were read out to validate the absolute dosimetry for TSET. Results: The OSLD measurements were within 7% agreement with the planned dose except the shoulder areas, where the doses recorded were 23% lower on average than those of the planned. The EBT3 film measurements were within 10% agreement with the planned dose except the shoulder and the scalp vertex areas, where the respective doses recorded were 18% and 14% lower on average than those of the planned. The OSLDs gave more consistent dose measurements than those of the EBT3 films. Conclusion: The absolute dosimetry for TSET was validated by an end-to-end test with a Rando phantom using the OSLDs and EBT3 films. The beam calibration and monitor unit calculations were confirmed.

60 APPLIED LIFE SCIENCES↗

SU-F-T-208: An Efficient Planning Approach to Posterior Fossa Tumor Bed Boosts Using Proton Pencil Beam Scanning in Fixed-Beam Room

Purpose: A fixed-beam room could be underutilized in a multi-room proton center. We investigated the use of proton pencil beam scanning (PBS) on a fixed-beam as an alternative for posterior fossa tumor bed (PF-TB) boost treatments which were usually treating on a gantry with uniform scanning. Methods: Five patients were treated with craniospinal irradiation (CSI, 23.4 or 36.0 Gy(RBE)) followed by a PF-TB boost to 54 Gy(RBE) with proton beams. Three PF-TB boost plans were generated for each patient: (1) a uniform scanning (US) gantry plan with 4–7 posterior fields shaped with apertures and compensators (2) a PBS plan using bi-lateral and vertex fields with a 3-mm planning organ-at-risk volume (PRV) expansion around the brainstem and (3) PBS fields using same beam arrangement but replacing the PRV with robust optimization considering a 3-mm setup uncertainty. Results: A concave 54-Gy(RBE) isodose line surrounding the brainstem could be achieved using all three techniques. The mean V95% of the PTV was 99.7% (range: 97.6% to 100%) while the V100% of the PTV ranged from 56.3% to 93.1% depending on the involvement of the brainstem with the PTV. The mean doses received by 0.05 cm{sup 3} of the brainstem were effectively identical: 54.0 Gy(RBE), 53.4 Gy(RBE) and 53.3 Gy(RBE) for US, PBS optimized with PRV, and PBS optimized with robustness plans respectively. The cochlea mean dose increased by 23% of the prescribed boost dose in average from the bi-lateral fields used in the PBS plan. Planning time for the PBS plan with PRV was 5–10 times less than the US plan and the robustly optimized PBS plan. Conclusion: We have demonstrated that a fixed-beam with PBS can deliver a dose distribution comparable to a gantry plan using uniform scanning. Planning time can be reduced substantially using a PRV around the brainstem instead of robust optimization.

60 APPLIED LIFE SCIENCES↗

SU-F-T-394: Impact of PTV Margins With Taking Into Account Shape Variation On IMRT Plans For Prostate Cancer

Purpose: The purpose of this study was to investigate the impact of planning target volume (PTV) margins with taking into consideration clinical target volume (CTV) shape variations on treatment plans of intensity modulated radiation therapy (IMRT) for prostate cancer. Methods: The systematic errors and the random errors for patient setup errors in right-left (RL), anterior-posterior (AP), and superior-inferior (SI) directions were obtained from data of 20 patients, and those for CTV shape variations were calculated from 10 patients, who were weekly scanned using cone beam computed tomography (CBCT). The setup error was defined as the difference in prostate centers between planning CT and CBCT images after bone-based registrations. CTV shape variations of high, intermediate and low risk CTVs were calculated for each patient from variances of interfractional shape variations on each vertex of three-dimensional CTV point distributions, which were manually obtained from CTV contours on the CBCT images. PTV margins were calculated using the setup errors with and without CTV shape variations for each risk CTV. Six treatment plans were retrospectively made by using the PTV margins with and without CTV shape variations for the three risk CTVs of 5 test patients. Furthermore, the treatment plans were applied to CBCT images for investigating the impact of shape variations on PTV margins. Results: The percentages of population to cover with the PTV, which satisfies the CTV D98 of 95%, with and without the shape variations were 89.7% and 74.4% for high risk, 89.7% and 76.9% for intermediate risk, 84.6% and 76.9% for low risk, respectively. Conclusion: PTV margins taking into account CTV shape variation provide significant improvement of applicable percentage of population (P < 0.05). This study suggested that CTV shape variation should be taken consideration into determination of the PTV margins.

60 APPLIED LIFE SCIENCES↗

SU-F-T-406: Verification of Total Body Irradiation Commissioned MU Lookup Table Accuracy Using Treatment Planning System for Wide Range of Patient Sizes

Purpose: To verify the accuracy of total body irradiation (TBI) measurement commissioning data using the treatment planning system (TPS) for a wide range of patient separations. Methods: Our institution conducts TBI treatments with an 18MV photon beam at 380cm extended SSD using an AP/PA technique. Currently, the monitor units (MU) per field for patient treatments are determined using a lookup table generated from TMR measurements in a water phantom (75 × 41 × 30.5 cm3). The dose prescribed to an umbilicus midline point at spine level is determined based on patient separation, dose/ field and dose rate/MU. One-dimensional heterogeneous dose calculations from Pinnacle TPS were validated with thermoluminescent dosimeters (TLD) placed in an average adult anthropomorphic phantom and also in-vivo on four patients with large separations. Subsequently, twelve patients with various separations (17–47cm) were retrospectively analyzed. Computed tomography (CT) scans were acquired in the left and right decubitus positions from vertex to knee. A treatment plan for each patient was generated. The ratio of the lookup table MU to the heterogeneous TPS MU was compared. Results: TLD Measurements in the anthropomorphic phantom and large TBI patients agreed with Pinnacle calculated dose within 2.8% and 2%, respectively. The heterogeneous calculation compared to the lookup table agreed within 8.1% (ratio range: 1.014–1.081). A trend of reduced accuracy was observed when patient separation increases. Conclusion: The TPS dose calculation accuracy was confirmed by TLD measurements, showing that Pinnacle can model the extended SSD dose without commissioning a special beam model for the extended SSD geometry. The difference between the lookup table and TPS calculation potentially comes from lack of scatter during commissioning when compared to extreme patient sizes. The observed trend suggests the need for development of a correction factor between the lookup table and TPS dose calculations.

60 APPLIED LIFE SCIENCES↗

A tracking system to calculate patient skin dose in real-time during neurointerventional procedures using a biplane x-ray imaging system

Purpose: Neurovascular interventional procedures using biplane fluoroscopic imaging systems can lead to increased risk of radiation-induced skin injuries. The authors developed a biplane dose tracking system (Biplane-DTS) to calculate the cumulative skin dose distribution from the frontal and lateral x-ray tubes and display it in real-time as a color-coded map on a 3D graphic of the patient for immediate feedback to the physician. The agreement of the calculated values with the dose measured on phantoms was evaluated. Methods: The Biplane-DTS consists of multiple components including 3D graphic models of the imaging system and patient, an interactive graphical user interface, a data acquisition module to collect geometry and exposure parameters, the computer graphics processing unit, and functions for determining which parts of the patient graphic skin surface are within the beam and for calculating dose. The dose is calculated to individual points on the patient graphic using premeasured calibration files of entrance skin dose per mAs including backscatter; corrections are applied for field area, distance from the focal spot and patient table and pad attenuation when appropriate. The agreement of the calculated patient skin dose and its spatial distribution with measured values was evaluated in 2D and 3D for simulated procedure conditions using a PMMA block phantom and an SK-150 head phantom, respectively. Dose values calculated by the Biplane-DTS were compared to the measurements made on the phantom surface with radiochromic film and a calibrated ionization chamber, which was also used to calibrate the DTS. The agreement with measurements was specifically evaluated with variation in kVp, gantry angle, and field size. Results: The dose tracking system that was developed is able to acquire data from the two x-ray gantries on a biplane imaging system and calculate the skin dose for each exposure pulse to those vertices of a patient graphic that are determined to be in the beam. The calculations are done in real-time with a typical graphic update time of 30 ms and an average vertex separation of 3 mm. With appropriate corrections applied, the Biplane-DTS was able to determine the entrance dose within 6% and the spatial distribution of the dose within 4% compared to the measurements with the ionization chamber and film for the SK150 head phantom. The cumulative dose for overlapping fields from both gantries showed similar agreement. Conclusions: The Biplane-DTS can provide a good estimate of the peak skin dose and cumulative skin dose distribution during biplane neurointerventional procedures. Real-time display of this information should help the physician manage patient dose to reduce the risk of radiation-induced skin injuries.

60 APPLIED LIFE SCIENCES↗

Emergent magnetic monopole dynamics in macroscopically degenerate artificial spin ice

Magnetic monopoles, proposed as elementary particles that act as isolated magnetic south and north poles, have long attracted research interest as magnetic analogs to electric charge. In solid-state physics, a classical analog to these elusive particles has emerged as topological excitations within pyrochlore spin ice systems. We present the first real-time imaging of emergent magnetic monopole motion in a macroscopically degenerate artificial spin ice system consisting of thermally activated Ising-type nanomagnets lithographically arranged onto a pre-etched silicon substrate. A real-space characterization of emergent magnetic monopoles within the framework of Debye-Hückel theory is performed, providing visual evidence that these topological defects act like a plasma of Coulomb-type magnetic charges. In contrast to vertex defects in a purely two-dimensional artificial square ice, magnetic monopoles are free to evolve within a divergence-free vacuum, a magnetic Coulomb phase, for which features in the form of pinch-point singularities in magnetic structure factors are observed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Crystal structure of Rb{sub 2}[Ti(VO{sub 2}){sub 3}(PO{sub 4}){sub 3}]

The crystal structure of the new compound Rb{sub 2}[Ti(VO{sub 2}){sub 3}(PO{sub 4}){sub 3}] obtained by hydrothermal synthesis in the RbCl-TiPO{sub 4}-V{sub 2}O{sub 5}-B{sub 2}O{sub 3}-H{sub 2}O system (a = 13.604(2) A, c = 9.386(2) A, sp. gr. P6cc, Z = 4, {rho}{sub calcd} = 3.32 g/cm{sup 3}) has been studied by X-ray diffraction (Xcalibur-S-CCD diffractometer, R = 0.038). It is shown that the isotypism of Rb{sub 2}[Ti(VO{sub 2}){sub 3}(PO{sub 4}){sub 3}] and Cs{sub 2}[Ti(VO{sub 2}){sub 3}(PO{sub 4}){sub 3}] is caused by the flexibility of a mixed anionic framework composed of phosphorus tetrahedra, vanadium five-vertex polyhedra, and titanium octahedra (bases of the crystal structures of these compounds). The topological correlations between the structures of titanium-vanadyl phosphates and benitoite and beryl silicates are analyzed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

New isoformula potassium borosilicates with different zeolite frameworks: Monoclinic centrosymmetric boroleucite K(BSi{sub 2})O{sub 6} and chiral KBSi{sub 2}O{sub 6}

The structures of new isoformula potassium borosilicates, obtained under hydrothermal conditions, namely, the monoclinic modification of the cubic boroleucite K(BSi{sub 2})O{sub 6} (space group P2{sub 1}/a), which was previously unknown, and chiral KBSi{sub 2}O{sub 6} (space group P2{sub 1}2{sub 1}2{sub 1})) are studied. A framework is formed both in the monoclinic and orthorhombic new structure in which each two tetrahedra share a vertex, as is typical of silicate frameworks. Since the two compounds have the same chemical formula, they could be spoken of as polymorphic modifications, but they are essentially different in structure: in the orthorhombic phase, the B and Si atoms are distributed over the tetrahedra in an ordered fashion, whereas B together with Si occupy statistically all tetrahedra in the monoclinic modification of boroleucite. The frameworks of both compounds are similar, although the framework is slightly denser in the orthorhombic borosilicate. Large rings consisting of six, seven, or eight tetrahedra determine the zeolite type of the frameworks, whose voids accommodate K atoms.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Structural conditionality of the piezoelectric properties of langasite family crystals

The atomic displacements upon isomorphic substitutions in crystals of the langasite family have been analyzed. The thermal parameters are determined and the probability density function of atoms is analyzed. Local potential energy minima are found which can be occupied by atoms under external effects. The contributions of cations in all four independent crystallographic positions and anions in all three such positions to the piezoelectric properties are established. One specific structural feature is the constant (at isomorphic substitutions) or possible (under external effects) but always opposite displacements of two cations along symmetry axis 2. Large cations in eight-vertex polyhedra make the main contribution to the piezoelectric properties. The cations in the tetrahedra on symmetry axis 2 weaken these properties. The cations in the octahedra in the origin of coordinates and in the tetrahedra on symmetry axes 3 only slightly affect the piezoelectricity.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Ordering of cations in the voids of the anionic framework of the crystal structure of catapleiite

The pseudohexagonal crystal structure of the mineral catapleiite Na{sub 1.5}Ca{sub 0.2}[ZrSi{sub 3}(O,OH){sub 9}] {center_dot} 2(H{sub 2}O,F) from the Zhil'naya Valley in the central part of the Khibiny alkaline massif (Kola Peninsula, Russia) is studied by X-ray diffraction (XCalibur-S diffractometer, R = 0.0346): a = 20.100(4), b = 25.673(5), and c = 14.822(3) A; space group Fdd2, Z = 32, and {rho}{sub calcd} = 2.76 g/cm{sup 3}. Fluorine atoms substituting part of H{sub 2}O molecules in open channels of the crystal structure have been found for the first time in the catapleiite composition by microprobe analysis. The pattern of distribution of Na and Ca atoms over the voids of the mixed anionic framework consisting of Zr-octahedra and three-membered rings of Si-tetrahedra accounts for the pronounced pseudoperiodicity along the a and c axes of the pseudohexagonal unit cell and for the lowering of crystal symmetry to the orthorhombic one. It is shown that part of the hydrogen atoms of water molecules is statistically disordered; their distribution correlates with the pattern of the population of large eight-vertex polyhedra by Na and Ca atoms.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Crystal-structure refinement of zirconium-rich eudialyte and its place among calcium-poor eudialyte-group minerals

The repeated refinement of the crystal structure of zirconium-rich eudialyte based on the X-ray diffraction data set collected earlier revealed new structural features. The trigonal unit-cell parameters are a = 14.222(3) A, c = 30.165(5) A, V = 5283.9 A{sup 3}. The refinement resulted in the reduction of the R factor from 0.045 (2347F > 4{sigma}(F)) to 0.035 (3124F > 3{sigma}(F)). It was found that the ordering of Ca and Fe in six-membered rings leads to the lowering of the symmetry to R3. An excess amount of zirconium (more than three atoms per symmetrically independent unit) is located in the M2 microregion in square and five-vertex polyhedral positions. However, this amount is insufficient to be dominant, and the deficiency of zirconium is compensated for by sodium atoms. Based on the new data, zirconium-rich eudialyte can be assigned to the oneillite subtype, being a zirconium-rich and aluminum variety of raslakite.

36 MATERIALS SCIENCE↗