Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “VIBRATION MEASUREMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

Space Qualification of Laser Diode Arrays

Laser instruments have great potential in enabling a new generation of remote-sensing scientific instruments. NASA s desire to employ laser instruments aboard satellites, imposes stringent reliability requirements under severe conditions. As a result of these requirements, NASA has a research program to understand, quantify and reduce the risk of failure to these instruments when deployed on satellites. Most of NASA s proposed laser missions have base-lined diode-pumped Nd:YAG lasers that generally use quasi-constant wave (QCW), 808 nm Laser Diode Arrays (LDAs). Our group has an on-going test program to measure the performance of these LDAs when operated in conditions replicating launch and orbit. In this paper, we report on the results of tests designed to measure the effect of vibration loads simulating launch into space and the radiation environment encountered on orbit. Our primary objective is to quantify the performance of the LDAs in conditions replicating those of a satellite instrument, determine their limitations and strengths which will enable better and more robust designs. To this end we have developed a systematic testing strategy to quantify the effect of environmental stresses on the optical and electrical properties of the LDA.

Troupaki, Elisavet↗

Subframe Burst Gating for Raman Spectroscopy in Combustion

We describe an architecture for spontaneous Raman scattering utilizing a frame-transfer CCD sensor operating in a subframe burst-gating mode to realize time-resolved combustion diagnostics. The technique permits all-electronic optical gating with microsecond shutter speeds 5 J.Ls) without compromising optical throughput or image fidelity. When used in conjunction with a pair of orthogonally polarized excitation lasers, the technique measures single-shot vibrational Raman scattering that is minimally contaminated by problematic optical background noise.

Kojima, Jun↗

Lessons in the Design and Characterization Testing of the Semi-Span Super-Sonic Transport (S4T) Wind-Tunnel Model

This paper focuses on some of the more challenging design processes and characterization tests of the Semi-Span Super-Sonic Transport (S4T)-Active Controls Testbed (ACT). The model was successfully tested in four entries in the National Aeronautics and Space Administration Langley Transonic Dynamics Tunnel to satisfy the goals and objectives of the Fundamental Aeronautics Program Supersonic Project Aero-Propulso-Servo-Elastic effort. Due to the complexity of the S4T-ACT, only a small sample of the technical challenges for designing and characterizing the model will be presented. Specifically, the challenges encountered in designing the model include scaling the Technology Concept Airplane to model scale, designing the model fuselage, aileron actuator, and engine pylons. Characterization tests included full model ground vibration tests, wing stiffness measurements, geometry measurements, proof load testing, and measurement of fuselage static and dynamic properties.

Source record↗

Interference-free optical detection for Raman spectroscopy

An architecture for spontaneous Raman scattering (SRS) that utilizes a frame-transfer charge-coupled device (CCD) sensor operating in a subframe burst gating mode to realize time-resolved combustion diagnostics is disclosed. The technique permits all-electronic optical gating with microsecond shutter speeds (<5 .mu.s), without compromising optical throughput or image fidelity. When used in conjunction with a pair of orthogonally-polarized excitation lasers, the technique measures time-resolved vibrational Raman scattering that is minimally contaminated by problematic optical background noise.

Nguyen, Quang-Viet↗

Experimental Validation of the Dynamic Inertia Measurement Method to Find the Mass Properties of an Iron Bird Test Article

This presentation describes the DIM method and how it measures the inertia properties of an object by analyzing the frequency response functions measured during a ground vibration test (GVT). The DIM method has been in development at the University of Cincinnati and has shown success on a variety of small scale test articles. The NASA AFRC version was modified for larger applications.

dynamic structural analysis↗

Testing and Validation of the Dynamic Interia Measurement Method

This presentation describes the DIM method and how it measures the inertia properties of an object by analyzing the frequency response functions measured during a ground vibration test (GVT). The DIM method has been in development at the University of Cincinnati and has shown success on a variety of small scale test articles. The NASA AFRC version was modified for larger applications.

vibration tests↗

Characterization of CO Thermochemistry in Incident Shockwaves

Incident shock waves in pure CO have been characterized in the Electric Arc Shock Tube facility at NASA Ames Research Center. Spectrally and spatially resolved emission spectra characterize radiative signatures from CO in the VUV (Vacuum Ultra-Violet) and mid-infrared and atomic carbon and C2 in the visible. CO absorption of a single vibrational line is also measured with a tunable diode laser. The experimental data analyzed here are at a pressure of 0.25 Torr in the driven section and span a shock velocity range from 3.4-9.5 km/s. The emission and absorption signals are analyzed to extract temperature relaxation behind the shock which is used to derive the rate of CO dissociation. The emission spectra are compared to results using different kinetic parameters for CO dissociation and C2 dissociation and exchange. Different rates from the literature are found to match the data from 3.4-6.6 km/s and 6.6-9.5 km/s. Areas for improvement in CO and C2 radiation modeling are suggested on the basis of the analysis.

Entry↗

Spectroscopic On-Line Monitoring for Process Control and Safeguarding of Radiochemical Streams in Nuclear Fuel Reprocessing Facilities

The current book chapter presents preliminary work toward the use of spectroscopic on-line monitoring for process control and safeguarding of radiochemical streams. Raman spectroscopy was demonstrated as a method for determining U(VI), nitrate, and nitric acid, while visible-near-infrared (vis-NIR) spectroscopy was demonstrated as a method for determining Pu(IV), Np(V), U(VI) and Nd(III). This method has been established using fuel reprocessing solution stimulants under dynamic flow conditions and on commercial spent nuclear fuel samples. Partial least squares (PLS) models for each analyte were prepared, and the fits of the data presented. A brief review of literature relevant to the use of vibrational spectroscopy and physicochemical measurements for process monitoring of nuclear fuel solutions is reported.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Data Challenges in Multi-Sensor Data Science System for Monitoring a Solvent Extraction Process

Idaho National Laboratory (INL) is maintaining and gaining knowledge into the nuclear fuel cycle by building a test bed to allow researchers the opportunity to study nuclear fuel processing operations. This includes studying solvent extraction processes that use centrifugal contactors. As part of INL’s mission, the goal of this project is to develop a system that utilizes non-traditional measurement sources such as vibration, acoustics, current, light, flow, and temperature in conjunction with data-based, machine learning techniques that will allow for signal discovery. This multisensory data can support the development of safeguards by design, provide operator process awareness, and discover process anomalies. This poster will highlight some of the data collection and analytics challenges for the multi-sensor system as well as the mitigation strategies to build a robust system. Additionally, some preliminary data from the first testing campaign will be shown to help illustrate the data needs of the system.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Preliminary Results of a Multi-Sensor Data Science System for Monitoring a Solvent Extraction Process

Idaho National Laboratory is building a test bed to allow researchers the opportunity to study nuclear fuel processing operations. This includes studying the solvent extraction process and the use of centrifugal contactors. The goal of this project is to develop a system that utilizes non-traditional measurement sources such as vibration, acoustics, current, color, flow, and temperature in conjunction with data-based, machine learning techniques that will allow for signal discovery. This multi-sensor data supports the development of safeguards by design, provides operator process awareness, and aids in the discovery of process anomalies. This paper highlights some of the preliminary results from initial data collection campaigns and shares some of the lessons learned.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Nitrogen Vacancy Centers in Diamond for Stress Sensing Applications: Theory and Experiments

Sensing of stress under high elevated environmental conditions with high resolution has critical importance for range of applications including earth’s subsurface scanning and geological CO2 storage monitoring. Using first principles density functional theory (DFT) approach combined with the theoretical modelling of low energy Hamiltonian, here we investigate a novel approach to detect unprecedented level of pressure by taking advantage of solid-state electron’s spin of Nitrogen vacancy (NV) centers in nanodiamond. We computationally explore the effect of strain on the defect band edges and band gaps by varying the lattice parameters of diamond supercell hosting a single NV center. A low energy Hamiltonian is developed that includes effect of stress on the energy level of ±1 spin manifold at the ground state. By quantifying the energy level shift and split, we predict the pressure sensing of up to 0.3 MPa/√Hz. We show superiority of the quantum sensing over traditional optical sensing techniques by discussing our results from DFT and theoretical modelling for the frequency shift per unit pressure. The proposed quantum stress sensing could be useful to measure earth’s subsurface vibrations. Our results open avenues for development of sensing technology with a high sensitivity and resolution under extreme pressure conditions that potentially has a wider applicability than existing pressure sensing technologies.

Paudel, Hari P.↗

Development of High Stability Supports for NSLS-II RF BPMS

The NSLS-II Light Source being built at Brookhaven National Laboratory is expected to provide submicron stability of the electron orbit in the storage ring in order to fully utilize the very small emittances of the electron beam. This requires high stability supports for BPM pickup electrodes located near insertion device sources. Here we provide details for the design and development of these supports as well as measurement of thermal and vibrational stability of a prototype support.

43 PARTICLE ACCELERATORS↗

Apparatus and methods for determining at least one characteristic of a proximate environment

Methods and an apparatus for determining at least one characteristic of an environment are disclosed. A vibrational energy may be imparted into an environment and a magnitude of damping of the vibrational energy may be measured and at least one characteristic of the environment may be determined. Particularly, a vibratory source may be operated and coupled to an environment. At least one characteristic of the environment may be determined based on a shift in at least one steady-state frequency of oscillation of the vibratory source. An apparatus may include at least one vibratory source and a structure for positioning the at least one vibratory source proximate to an environment. Further, the apparatus may include an analysis device for determining at least one characteristic of the environment based at least partially upon shift in a steady-state oscillation frequency of the vibratory source for the given impetus.

47 OTHER INSTRUMENTATION↗

Frequency‐Locked Wireless Multifunctional Surface Acoustic Wave Sensors

Abstract Surface acoustic waves (SAWs) have shown great potential for developing sensors for structural health monitoring (SHM) and lab‐on‐a‐chip (LOC) applications. Existing SAW sensors mainly rely on measuring the frequency shifts of high‐frequency (e.g., >0.1 GHz) resonance peaks. This study presents frequency‐locked wireless multifunctional SAW sensors that enable multiple wireless sensing functions, including strain sensing, temperature measurement, water presence detection, and vibration sensing. These sensors leverage SAW resonators on piezoelectric chips, inductive coupling‐based wireless power transmission, and, particularly, a frequency‐locked wireless sensing mechanism that works at low frequencies (e.g., <0.1 GHz). This mechanism locks the input frequency on the slope of a sensor's reflection spectrum and monitors the reflection signal's amplitude change induced by the changes of sensing parameters. The proof‐of‐concept experiments show that these wireless sensors can operate in a low‐power active mode for on‐demand wireless strain measurement, temperature sensing, and water presence detection. Moreover, these sensors can operate in a power‐free passive mode for vibration sensing, with results that agree well with laser vibrometer measurements. It is anticipated that the designs and mechanisms of the frequency‐locked wireless SAW sensors will inspire researchers to develop future wireless multifunctional sensors for SHM and LOC applications.

Bo, Luyu↗

N2-broadening in the HCl vibrational fundamental - Temperature dependence between 160 and 296 K

Measurements were conducted of the N2-broadening coefficients in the vibrational fundamental line of HCl at 160, 182, 216, 255, and 296 K. It is found that the N2 broadening of rovibrational lines in the -6 to +6 range is well described by a simple power-law dependence on temperature. The temperature-interpolation of these results is noted to be in good agreement with previous low-temperature studies.

Chackerian, C., Jr.↗

Dynamic Capability of an Operating Stirling Convertor

The NASA John H. Glenn Research Center and the US Department of Energy are currently developing a Stirling convertor for use as an advanced spacecraft power system for future NASA deep-space missions. NASA Headquarters has recently identified the Stirling technology generator for potential use as the spacecraft power system for two of NASA's new missions, the Europa Orbiter and the Solar Probe missions (planned for launch in 2006 and 2007 respectively). As part of the development of this power system, a Stirling Technology Demonstration Convertor was vibration tested at NASA John H. Glenn Research Center to verify its survivability and capability of withstanding the harsh dynamic environment typically seen by the spacecraft when it is launched by an expendable launch vehicle. The Technology Demonstration Convertor was fully operational (producing power) during the random vibration testing. The output power of the convertor and other convertor performance indicators were measured during the testing, and these results are discussed in this paper. Numerous accelerometers and force gauges also were used to provide information on the dynamic characteristics of the Technology Demonstration Convertor and as an indication of any possible damage due to the vibration. These measurements will also be discussed in this paper. The vibration testing of the Stirling Technology Demonstration Convertor was extremely successful. The Technology Demonstration Convertor survived all its vibration testing with no structural damage or functional performance degradation. As a result of this testing, the Stirling convertor's capability to withstand vibration has been demonstrated, enabling its usage in future spacecraft power systems.

Goodnight, Thomas W.↗

Adsorption mechanism of alkyl hydroxamic acid onto bastnäsite: Fundamental steps toward rational collector design for rare earth elements

Rare earth element (REE) production is limited in part by inefficient strategies for beneficiation. Hydroxamic acid ligands are promising reagents for the selective flotation of bastnäsite [(Ce,La)FCO 3 ], a major REE ore mineral, but the mechanism and energetics of adsorption are not understood, interfering with the design of new, more efficient reagents. In this work, the adsorption of octyl hydroxamic acid onto bastnäsite was calculated using a combination of experimental and computational methods. In-situ attenuated total reflectance Fourier transform infrared (ATR-FTIR) spectroscopy revealed changes in the hydroxamate functional group vibrational frequencies, corresponding to chelation with cerium cations at the bastnäsite surface. The results indicate a monodentate chemisorption mechanism at low surface loading that changes to bidentate chemisorption at higher concentrations. This interpretation is supported by molecular vibrational frequency shifts calculated using density functional theory (DFT), and orientation of the hydrocarbon chain measured by sum frequency generation (SFG) vibrational spectroscopy. The binding enthalpies of octyl hydroxamic acid interacting with La and Ce-bastnäsite surfaces were measured using isothermal titration calorimetry (ITC) revealing a stronger coordinating ability with bastnäsite than with a common gangue mineral, calcite (CaCO 3 ). Because octyl hydroxamate favors monodentate adsorption at low surface coverages, the relative chelating strength of metal ions could be a poor predictor for selectivity under monolayer adsorption conditions. At higher surface loadings, where the bidentate mode of adsorption is active, selectivity is likely to be limited by increased flotation of gangue ores.

58 GEOSCIENCES↗

Experimental studies for determining human discomfort response to vertical sinusoidal vibration

A study was conducted to investigate several problems related to methodology and design of experiments to obtain human comfort response to vertical sinusoidal vibration. Specifically, the studies were directed to the determination of (1) the adequacy of frequency averaging of vibration data to obtain discomfort predictors, (2) the effect of practice on subject ratings, (3) the effect of the demographic factors of age, sex, and weight, and (4) the relative importance of seat and floor vibrations in the determination of measurement and criteria specification location. Results indicate that accurate prediction of discomfort requires knowledge of both the acceleration level and frequency content of the vibration stimuli. More importantly, the prediction of discomfort was shown to be equally good based upon either floor accelerations or seat accelerations. Furthermore, it was demonstrated that the discomfort levels in different seats resulting from similar vibratory imputs were equal. Therefore, it was recommended that criteria specifications and acceleration measurements be made at the floor location. The results also indicated that practice did not systematically influence discomfort responses nor did the demographic factors of age, weight, and sex contribute to the discomfort response variation.

Dempsey, T. K.↗