Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “VENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

Endovascular Treatment of Two Pseudoaneurysms Originating From the Left Ventricle

A 67-year-old woman resented with an acute type A aortic dissection, which was treated surgically with aortic valve replacement as a composite graft with reimplantation of the coronary arteries. At the end of surgery, a left-ventricular venting catheter was placed through the apex and closed with a buffered suture. Consecutive computed tomography (CT) examinations verified a growing apex pseudoaneurysm. Communication between the ventricle and the pseudoaneurysm was successfully closed with an Amplatz septal plug by the transfemoral route. Follow-up CT showed an additional pseudoaneurysm, which also was successfully closed using the same method.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Changes in magma storage conditions following caldera collapse at Okataina Volcanic Center, New Zealand

Large silicic volcanic centers produce both small rhyolitic eruptions and catastrophic caldera-forming eruptions. Although changes in trace element and isotopic compositions within eruptions following caldera collapse have been observed at rhyolitic volcanic centers such as Yellowstone and Long Valley, much still remains unknown about the ways in which magma reservoirs are affected by caldera collapse. We present 238 U– 230 Th age, trace element, and Hf isotopic data from individual zircon crystals from four eruptions from the Okataina Volcanic Center, Taupo Volcanic Zone, New Zealand, in order to assess changes in trace element and isotopic composition of the reservoir following the 45-ka caldera-forming Rotoiti eruption. Our data indicate that (1) mixing of magmas derived from crustal melts and mantle melts takes place within the shallow reservoir; (2) while the basic processes of melt generation likely did not change significantly between pre- and post-caldera rhyolites, post-caldera zircons show increased trace element and isotopic heterogeneity that suggests a decrease in the degree of interconnectedness of the liquid within the reservoir following collapse; and (3) post-caldera eruptions from different vents indicate different storage times of the amalgamated melt prior to eruption. Furthermore, these data further suggest that the timescales needed to generate large volumes of eruptible melt may depend on the timescales needed to increase interconnectedness and achieve widespread homogenization throughout the reservoir.

230Th–238U↗

Volcano infrasound: progress and future directions

Over the past two decades (2000–2020), volcano infrasound (acoustic waves with frequencies less than 20 Hz propagating in the atmosphere) has evolved from an area of academic research to a useful monitoring tool. As a result, infrasound is routinely used by volcano observatories around the world to detect, locate, and characterize volcanic activity. It is particularly useful in confirming subaerial activity and monitoring remote eruptions, and it has shown promise in forecasting paroxysmal activity at open-vent systems. Fundamental research on volcano infrasound is providing substantial new insights on eruption dynamics and volcanic processes and will continue to do so over the next decade. The increased availability of infrasound sensors will expand observations of varied eruption styles, and the associated increase in data volume will make machine learning workflows more feasible. More sophisticated modeling will be applied to examine infrasound source and propagation effects from local to global distances, leading to improved infrasound-derived estimates of eruption properties. Future work will use infrasound to detect, locate, and characterize moving flows, such as pyroclastic density currents, lahars, rockfalls, lava flows, and avalanches. Infrasound observations will be further integrated with other data streams, such as seismic, ground- and satellite-based thermal and visual imagery, geodetic, lightning, and gas data. The volcano infrasound community should continue efforts to make data and codes accessible and to improve diversity, equity, and inclusion in the field. In summary, the next decade of volcano infrasound research will continue to advance our understanding of complex volcano processes through increased data availability, sensor technologies, enhanced modeling capabilities, and novel data analysis methods that will improve hazard detection and mitigation.

58 GEOSCIENCES↗

Isolated vesicles in submarine pumice: insights from the 2019 Volcano F eruption, Kingdom of Tonga

No reliable method can distinguish between subaerial and submarine pumice, but recent work shows that highly vesicular (total porosity, φ > 65%) submarine pumice from the 2012 Havre and 2021 Fukutoku Oka-no-Ba eruptions contains abundant isolated porosity (connectivity, C < 0.6). This differs from textural measurements of subaerial pumice with similarly high vesicularities, where high connectivities (C > 0.8) are often measured. To investigate the implications of this under-studied texture for bubble nucleation, growth, and coalescence dynamics at submarine eruptions, we analyze the textural characteristics of rafted pumice clasts from the 2019 submarine eruption of Volcano F, located along the Tonga-Kermadec Arc. We examined clasts collected while floating near the vent (50–200 km) and distally on the shores of Fiji (900 km). Using helium pycnometry and X-ray tomography (XRT), we quantified porosity and connectivity in 45 pumice lapilli, classifying them by vesicle macrotexture and edge morphology. Microvesicular clasts, the majority of which have breadcrust and cauliflower textures, exhibit the lowest connectivities (C = 0.61 ± 0.2), while macrovesicular clasts have high connectivities with C ~ 1. We propose that isolated porosity abundance varies according to clast location in the eruption column post-fragmentation. Microvesicular clasts erupted on the edges of the column and experienced high levels of seawater ingestion and subsequent quenching of the entire clast. Macrovesicular clasts, in contrast, erupted in the center of the eruption column and were thus thermally insulated, allowing magmatic bubbles in the molten pumice to nucleate, grow, and coalesce for longer. Our results and interpretation imply that low connectivity, microvesicular clasts preserve pre and syn-eruptive bubble processes at the 2019 Volcano F eruption.

Permeability↗

Comparative Study of Novel Fluorescent Cyanine Nucleotides: Hybridization Analysis of Labeled PCR Products Using a Biochip

This study investigated the synthesis and substrate properties of Cy5-labeled dUTP derivatives with different substituents, linkers between the dye unit and pyrimidine heterocycle and fluorophore charges. Fluorescently labeled nucleoside triphosphates were studied as substrates using multiplex PCR with Taq and Vent (exo-) DNA polymerases, the typical representatives of the A and B polymerase families. The efficiency of nucleotide incorporation during PCR was assessed with a multi-parameter hybridization analysis using a diagnostic DNA microarray. The hybridization analysis indirectly estimates the incorporation efficiency of dye-labeled nucleotides in multiplex PCR. Our results demonstrated higher efficiencies of substrates with electrically neutral dyes than electropositive and electronegative Cy5 residues.

60 APPLIED LIFE SCIENCES↗

RDX solubility in TNT at high temperatures

The solubility of RDX (hexahydro-1,3,5-tri-nitro-1,3,5-triazine) in TNT (2,4,6-trinitrotoluene) at elevated temperatures is required to accurately predict the response of Comp-B 3 (60:40 RDX:TNT) during accidents involving fire. As the temperature increases, the TNT component melts, the RDX partially dissolves in the liquid TNT, and the remaining RDX melts (203 °C) as the Comp-B thermally ignites. In the current work, we used a differential scanning calorimeter (DSC) to estimate the solubility of RDX in TNT at the melting point of RDX. Most DSC measurements of Comp-B 3 do not show an RDX melt endotherm. The absence of an endotherm associated with the RDX melt has been interpreted as RDX being completely dissolved in TNT before reaching the melting point. Here, we have observed that the endotherm is not absent, but is masked by exothermic reactions occurring at these elevated temperatures. We have inhibited the exothermic reactions by venting our DSC samples and measuring the RDX melt endotherm in our Comp-B 3 samples at about 203 °C. Using the measured heat flow associated with the RDX melt and the latent melting enthalpy of RDX, we have approximated the solubility of RDX in TNT to be roughly 50–100 g RDX per 100 g TNT . The broad range is based on corrections for exothermic reactions occurring as the RDX melts.

42 ENGINEERING↗

Spatio-temporal changes in CO2 emissions during the second ZERT injection, August-September 2008

This study reports the first field test of a multi-channel, auto-dilution, steady-state, soil-CO2 flux monitoring system being developed to help understand the pathways by which fugitive CO2 from a geologic sequestration site migrates to the surface. The test was conducted from late August through mid-October 2008 at the Zero Emissions Research and Technology (ZERT) project site located in Bozeman, MT. Twenty steady-state and five non-steady-state flux chambers were installed in a 10x15 m area, one boundary of which was directly above a shallow (2-m depth) horizontal injection well located 0.5 m below the water table. A total flux of 52 kg CO2 d-1.was injected into the well for 13 days and the efflux from the soil was monitored by the chambers before, during, and for 33 days after the injection. The results showed a rapid increase in soil efflux once injection started, with maximal values reached within 3-7 d in most chambers. Efflux returned to background levels within a similar time period after injection ceased. A radial efflux pattern was observed to at least 2 m from the injection well, and evidence for movement of the CO2 plume during the injection, presumably due to groundwater flow, was seen. The steady-state chambers yielded very stable data, but 3- to 5-fold higher fluxes than the non-steady-state chambers. The higher fluxes were attributed to vacuum induced in the steady-state chambers by narrow vent tubes. High winds resulted in significant decreases in measured soil CO2 efflux, presumably by enhancing efflux from soil outside the chambers.

continuous monitoring↗

Benchmark study of the DTU OWC chamber with both two-way and one-way absorption

This paper reports on a benchmark study based on small-scale (1:50) measurements of a single, oscillating water column chamber mounted sideways in a long flume. The geometry of the OWC chamber is extracted from a barge-like, attenuator-type floating concept “KNSwing” with 40 chambers targeted for deployment in the Danish part of the North Sea. In addition to traditional two-way energy extraction we also consider one-way energy extraction with passive venting and compare chamber response, pressures and total absorbed energy between the two methods. A blind study was established for the numerical modeling, with participants applying several implementations of weakly nonlinear potential flow theory and commercial Navier–Stokes solvers (CFD). Both compressible and incompressible models were used for the air phase. Potential flow calculations predict more energy absorption near the chamber resonance for one-way absorption than for two-way absorption, but the opposite is found from the experimental measurements. This outcome is mainly attributed to energy losses in the experimental passive valve system, but this conclusion must be confirmed by better experimental measurements. Modeling the one-way valve in CFD proved to be very challenging and only one team was able to provide results which were generally closer to the experiments. The study illustrates the challenges associated with both numerical and experimental analysis of OWC chambers. Air compressibility effects were not found to be important at this scale, even with the large volume of additional air used for the one-way case.

16 TIDAL AND WAVE POWER↗

Vacuum-assisted extrusion to reduce internal porosity in large-format additive manufacturing

Large-scale 3D printing of polymer composite structures has gained popularity and seen extensive use over the last decade. Much of the research related to improving the mechanical properties of 3D-printed parts has focused on exploring new materials and optimizing print parameters to improve geometric control and minimize voids between printed beads. However, porosity at the microstructural level (within the printed bead) has been much less studied although it is almost universally observed at levels of 4 %-10 % when using fiber reinforced materials. This study introduces a vacuum-assist approach that minimizes internal porosity by removing ambient air from the interstitial space between pellets in the hopper and acts as a negative pressure vent for gases that evolve during the initial stages of single-screw extrusion. Vacuum-assisted extrusion was able to reduce porosity below 2 % across a wide range of processing parameters, moisture content, fiber reinforcements, and printing platforms. Specifically, when printing on a large-format extruder (Strangpresse Model-30), the vacuum-assisted extrusion reduced internal porosity by 35–75 % compared to conventional non-vacuum extrusion, and only pores with length scale > 2 microns are affected. The success of this approach prompted the design of a patent-pending continuous vacuum hopper relevant for large-scale 3D printing on commercial systems.

36 MATERIALS SCIENCE↗

Simulation of Thermal Stratification in BWR Suppression Pools with One Dimensional Modeling Method

The suppression pool in a boiling water reactor (BWR) plant not only is the major heat sink within the containment system, but also provides the major emergency cooling water for the reactor core. In several accident scenarios, such as a loss-of-coolant accident and extended station blackout, thermal stratification tends to form in the pool after the initial rapid venting stage. Accurately predicting the pool stratification phenomenon is important because it affects the peak containment pressure; the pool temperature distribution also affects the NPSHa (available net positive suction head) and therefore the performance of the Emergency Core Cooling System and Reactor Core Isolation Cooling System pumps that draw cooling water back to the core. Current safety analysis codes use zero dimensional (0-D) lumped parameter models to calculate the energy and mass balance in the pool; therefore, they have large uncertainties in the prediction of scenarios in which stratification and mixing are important. While three-dimensional (3-D) computational fluid dynamics (CFD) methods can be used to analyze realistic 3-D configurations, these methods normally require very fine grid resolution to resolve thin substructures such as jets and wall boundaries, resulting in a long simulation time. For mixing in stably stratified large enclosures, the BMIX++ code (Berkeley mechanistic MIXing code in C++) has been developed to implement a highly efficient analysis method for stratification where the ambient fluid volume is represented by one-dimensional (1-D) transient partial differential equations and substructures (such as free or wall jets) are modeled with 1-D integral models. This allows very large reductions in computational effort compared to multi-dimensional CFD modeling. One heat-up experiment performed at the Finland POOLEX facility, which was designed to study phenomena relevant to Nordic design BWR suppression pool including thermal stratification and mixing, is used for validation. Comparisons between the BMIX++, GOTHIC, and CFD calculations against the POOLEX experimental data are discussed in detail.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Operator learning for energy-efficient building ventilation control with computational fluid dynamics simulation of a real-world classroom

Energy-efficient ventilation control plays an important role in reducing building energy consumption while ensuring occupant health and comfort. While Computational Fluid Dynamics (CFD) simulations provide detailed and physically accurate representations of indoor airflow, their high computational cost limits their use in real-time building control. In this work, we present a neural operator learning framework that combines the physical accuracy of CFD with the computational efficiency of machine learning to enable building ventilation control with the high-fidelity fluid dynamics models. Our method jointly optimizes the airflow supply rates and vent angles to reduce energy use and adhere to air quality constraints. We train an ensemble of neural operator transformer models to learn the mapping from building control actions to airflow fields using high-resolution CFD data. This learned neural operator is then embedded in an optimization-based control framework for building ventilation control. Experimental results show that our approach achieves significant energy savings compared to maximum airflow rate control, rule-based control, as well as data-driven control methods using spatially averaged CO 2 prediction and deep learning–based reduced-order models, while consistently maintaining safe indoor air quality. These results highlight the practicality and scalability of our method in maintaining energy efficiency and indoor air quality in real-world buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Direct molecular diffusion and micro-mixing for rapid dewatering of LiBr solution

A slow molecular diffusion rate often limits the desorption process of an absorbate molecule from a liquid absorbent. To enhance the desorption rate, the absorbent is often boiled to increase the liquid vapor interfacial area. However, the growth of bubbles generated during the nucleate boiling process still remains mass-diffusion limited. Here, it is shown that a desorption rate higher than that of boiling can be achieved, if the vapor absorbent interface is continuously replenished with the absorbate-rich solution to limit the concentration boundary layer growth. The study is conducted in a LiBr-water-solution, in which the water molecules' diffusion rate is quite slow. The manipulation of the vapor solution interface concentration distribution is enabled by the mechanical confinement of the solution flow within microchannels, using a hydrophobic vapor-venting membrane and the implementation of microstructures on the flow channel's bottom wall. The microstructures stretch and fold the laminar streamlines within the solution film and produce vortices. The vortices continuously replace the concentrated solution at the vapor solution interface with the water-rich solution brought from the bottom and middle of the flow channel. The physics of the process is described using a combination of experimental and numerical studies. Published by Elsevier Ltd.

Bigham, S↗

Energy efficient indoor VOC air cleaning with activated carbon fiber (ACF) filters

This study explores the potential environmental and energy benefits of using activated carbon fiber (ACF) filters for air cleaning in HVAC systems. The parallel aims for the air cleaning system were to enable reduced indoor exposures to volatile organic compounds (VOCs) and to simultaneously allow reduced rates and energy consumption for outdoor-air ventilation. We evaluated the use of ACF media to adsorb VOCs from indoor air during repeated simulated 12-hour to 24-hour periods of occupancy. In a cyclic regeneration process, VOCs were desorbed from the ACF media and vented outdoors to enable the next cycle of air cleaning. The VOC removal efficiency of the ACF media was measured using a 9.5-cm 2 ACF specimen exposed to a mixture of VOCs that included toluene, benzene, o-xylene, 1-butanol, limonene, undecane and formaldehyde at 29 °C and 30 percent relative humidity. The concentrations of these model pollutants upstream of the ACF media were in the range 20 to 30 ppb, to simulate realistic conditions. Velocities through the ACF media were typical of those in normal particle filter systems (~ 0.5 m s -1 ). Initial tests were conducted to develop a modified multi-component Freundlich isotherm and estimate the maximum adsorption capacity of the media, which was determined to be 90 mg VOC per gram of ACF. Three different ACF regeneration methods were explored using relatively cleaner outdoor air under ambient conditions, with this air humidified, and with the filter heated. It was found that heating the ACF media to ~150 °C by circulation of a DC current through the fibers for a short period (15 minutes) yielded the best VOC removal results, allowing for subsequent consistent removal efficiencies of 70-80 percent for most VOCs. Regeneration with unheated outdoor air was also effective and used less energy (subsequent removal efficiency was 50-60 percent for most VOCs). ACF did not perform as well in eliminating formaldehyde, for which a maximum removal of 25-30 percent was achieved with heated regeneration. A mass balance model indicated that the combination of ACF air cleaning and a 50percent reduction in ventilation will decrease indoor concentrations of VOCs by 60 percent to 80 percent and reduce formaldehyde concentrations by 12 percent to 40 percent. Energy modeling indicated the potential to reduce the energy required for heating and cooling of ventilation air by 35 percent to almost 50 percent.

54 ENVIRONMENTAL SCIENCES↗

Observations of airflow around a supertall curved building and its impact on temperature and humidity in Houston's urban center

Characterization of realistically shaped skyscrapers embedded in non-uniform neighbourhoods experiencing intricate weather patterns remains inadequately investigated. Aiming to close this gap, the Center for Multiscale Applied Sensing team deployed its mobile observatory in the street canyons around the curved Wells Fargo Plaza skyscraper in downtown Houston, TX. Three deployments allowed airflow observations under different inflow wind and thermodynamic stability conditions. Doppler lidar measurements reveal that when inflow hits the curved wall of the skyscraper, perpendicular canyons experience similar vortex configurations creating two windward and two leeward circulations. Windsond measurements support that buoyancy within the deep street canyons can generate thermal updrafts as strong as 2 m s -1 which is sufficient to overturn the mechanical downwash under gentle wind conditions. Canyons experiencing venting during the daytime were observed to be more thermodynamically stable at night while thermodynamically stable canyons during the day were observed to be more thermodynamically unstable at night owing to the accumulation of heat near street-level. Fourier decomposition of the vertical velocity measurements shows that in all cases flow exhibited high Reynolds numbers and was composed of turbulent eddies of predominantly 6 and 15 min periods. Here, this observational dataset provides insights to assess wind load, pedestrian comfort, urban air mobility, and natural ventilation and may be used as a benchmark for numerical model and wind tunnel studies attempting to represent realistically complex urban conditions.

54 ENVIRONMENTAL SCIENCES↗

Aspartate transformation at 200 °C with brucite [Mg(OH) 2 ], NH 3 , and H 2 : Implications for prebiotic molecules in hydrothermal systems

Hydrothermal systems may have been favorable environments for the evolution of prebiotic chemistry on early Earth due to the presence of chemical, temperature, and redox gradients that could promote the formation of biomolecules. However, the relevance of these environments in origins of life scenarios has been debated due to rapid decomposition of biologically essential species, such as amino acids, at high temperatures. Little is known about the reactivity of amino acids in the presence of mineral surfaces and reducing conditions, which reflect the geochemical complexities of environments such as serpentinite-hosted hydrothermal vents. We investigated the decomposition of 25 mM aspartate at 200 °C and 15.5 bars (P SAT ) in gold capsules both with and without brucite [Mg(OH) 2 ], a mineral product of serpentinization, and reducing conditions (NH 4 Cl and H 2(aq) ). Here we observed that the reaction products of aspartate vary significantly with the initial reaction conditions. Fluids containing aspartate only decomposed to fumarate, maleate, malate, acetate, and trace amounts of succinate and glycine. However, under reducing conditions, the main product was succinate (8 mM) and also approximately 1 mM total of the amino acids glycine, α-alanine, and β-alanine. The amount of α-alanine increased three-fold with brucite. Furthermore, we detected a two-fold decrease in the fumarate concentration, whereas total maleate concentration dramatically decreased over ten-fold and resulted in an overall increase in the trans/cis ratio of these deamination products of aspartate from 0.9 to 4.5 as a function of brucite loading. This net decrease in fumarate and maleate concentration and the five-fold increase in the trans/cis ratio might have been caused by a combination of a pH increase and the formation of magnesite due to increased Mg 2 + ion concentration. The results of this study provide evidence that the fundamental properties of a hydrothermal system, including mineral assemblages, reducing conditions, and dissolved species concentrations, will influence the fate of amino acids at high temperature.

58 GEOSCIENCES↗

Effects of position and frequency of obstacles on turbulent premixed propagating flames

This paper studies the effects of the number and location of solid obstacles on the rate of propagation of turbulent premixed flames. A vented explosion chamber is constructed where controlled premixed flames are ignited from rest to propagate past grids or baffles plates as well as other solid obstacles strategically positioned in the chamber. Laser Induced Fluorescence (LIF) is used to image OH which is used as an indicator of the reaction zone while pressure transducers are used to obtain pressure-time traces. Single grids or baffle plates located at different distances from the ignition source are tested. Two as well as three baffle plates are also investigated in varying configurations. It is found that while the peak overpressure increases with increasing number of grids or baffle plates, a limit is reached where the pressure starts to decrease. The location of the obstacles is found to have a significant effect on the overpressure and the flame structure. Higher overpressures are obtained when the baffle plates and obstacles are stacked closer together hence not allowing turbulence to decay. LIF images for OH show that the reaction zones become more contorted with increasing number of baffle plates in the flame path. (author)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗