Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Unit Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

Advancing Platooning with ADAS Control Integration and Assessment Test Results

The application of cooperative adaptive cruise control (CACC) to heavy-duty trucks known as truck platooning has shown fuel economy improvements over test track ideal driving conditions. However, there are limited test data available to assess the performance of CACC under real-world driving conditions. As part of the Cummins-led U.S. Department of Energy Funding Opportunity Announcement award project, truck platooning with CACC has been tested under real-world driving conditions and the results are presented in this paper. First, real-world driving conditions are characterized with the National Renewable Energy Laboratory’s Fleet DNA database to define the test factors. The key test factors impacting long-haul truck fuel economy were identified as terrain and highway traffic with and without advanced driver-assistance systems (ADAS). Track and on-highway testing guided by SAE J1321 procedures were conducted to assess truck platooning operation under the characterized real-world driving conditions. On-highway testing is done on a route in Indiana representing operation of long-haul Class 8 trucks in the United States. The road includes low-, medium-, and high-grade segments. The highway test results of a two-truck platooning configuration indicate considerable fuel-saving reduction comparing to the test track data collected under ideal driving conditions. The test data indicate that platooning could lead to increases in fuel consumption during traffic or high-grade portions of the route, causing reduction of the overall fuel saving on the road comparing to test track results. However, integration of ADAS features on the lead truck during on-road tests leads to significant improvement of fuel saving for both trucks in CACC operation.

ADAS↗

Discretization limits of lattice‐Boltzmann methods for studying immiscible two‐phase flow in porous media

Summary Digital images of porous media often include features approaching the image resolution length scale. The behavior of numerical methods at low resolution is therefore important even for well‐resolved systems. We study the behavior of the Shan‐Chen (SC) and Rothman‐Keller (RK) multicomponent lattice‐Boltzmann models in situations where the fluid‐fluid interfacial radius of curvature and/or the feature size of the medium approaches the discrete unit size of the computational grid. Various simple, small‐scale test geometries are considered, and a drainage test is also performed in a Bentheimer sandstone sample. We find that both RK and SC models show very high ultimate limits: in ideal conditions the models can simulate static fluid configuration with acceptable accuracy in tubes as small as three lattice units across for RK model (six lattice units for SC model) and with an interfacial radius of curvature of two lattice units for RK and SC models. However, the stability of the models is affected when operating in these extreme discrete limits: in certain circumstances the models exhibit behaviors ranging from loss of accuracy to numerical instability. We discuss the circumstances where these behaviors occur and the ramifications for larger‐scale fluid displacement simulations in porous media, along with strategies to mitigate the most severe effects. Overall we find that the RK model, with modern enhancements, exhibits fewer instabilities and is more suitable for systems of low fluid‐fluid miscibility. The shortcomings of the SC model seem to arise predominantly from the high, strongly pressure‐dependent miscibility of the two fluid components.

Li, Zhe↗

Completion Report for Model Evaluation Well ER-11-2: Corrective Action Unit 98: Frenchman Flat

Model Evaluation Well ER-11-2 was drilled for the U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office in support of Nevada Environmental Management Operations at the Nevada National Security Site (formerly known as the Nevada Test Site). The well was drilled in August 2012 as part of a model evaluation program in the Frenchman Flat area of Nye County, Nevada. The primary purpose of the well was to provide detailed geologic, hydrogeologic, chemical, and radionuclide data that can be used to test and build confidence in the applicability of the Frenchman Flat Corrective Action Unit flow and transport models for their intended purpose. In particular, this well was designed to provide data to evaluate the uncertainty in model forecasts of contaminant migration from the upgradient underground nuclear test PIN STRIPE, conducted in borehole U-11b in 1966. Well ER-11-2 will provide information that can be used to refine the Phase II Frenchman Flat hydrostratigraphic framework model if necessary, as well as to support future groundwater flow and transport modeling. The main 31.1-centimeter (cm) hole was drilled to a total depth of 399.6 meters (m). A completion casing string was not set in Well ER-11-2. However, a piezometer string was installed in the 31.1-cm open hole. The piezometer is composed of 7.3-cm stainless-steel tubing hung on 6.0-cm carbon-steel tubing via a crossover sub. The piezometer string was landed at 394.5 m, for monitoring the lower tuff confining unit. Data collected during and shortly after hole construction include composite drill cuttings samples collected every 3.0 m, various geophysical logs, water quality (including tritium and other test-related radionuclides) measurements, and water level measurements. The well penetrated 42.7 m of Quaternary and Tertiary alluvium and 356.9 m of Tertiary volcanic rock. The water-level measured in the piezometer string on September 25, 2012, was 353.8 m below ground surface. No tritium above levels detectable by field methods were encountered in this hole. No well development or hydrologic testing was conducted in this well immediately after completion, and future well development, sampling, and hydrologic testing planned for this well will be limited due to the diameter of the piezometer string. The stratigraphy, general lithology, and the water level are as expected, but the section of geology encountered is higher than expected due to faulting. No tritium above the minimum detection limit of the field equipment was detected because the target aquifer (the Topopah Spring aquifer) at Well ER-11-2 is structurally higher than expected and thus unsaturated.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Process with Decoupled Absorber Kinetics and Solvent Regeneration through Membrane Dewatering and In-Column Heat Transfer (Final Report)

This report summarizes the work conducted on project DE-FE0031604 where University of Kentucky Center for Applied Energy (UK CAER) has validated its intensified CO 2 capture process through substantial enhancements to the kinetics of the absorption process and energy reductions by absorber temperature profile modification, dewatering and heat integration technologies for achieving significant capital and operating cost reductions. To address DOE’s objective of improving post-combustion CO 2 capture technology and reducing associated cost, UK CAER employed an intensified process which combined three key aspects targeted at overcoming inherent limitations or barriers in the conventional CO 2 capture and desorption process. The process designed to be independent of the type of solvent used, included (1) the use of 3-D printed two-channel structured packing material to control the temperature profile and increase the CO 2 absorption rate in the absorber, (2) a zeolite membrane dewatering unit for dewatering of the carbon-rich solvent to decouple solvent concentration needs for CO 2 absorption and desorption, and (3) a rich-split feed with two-phase flow heat transfer prior to the stripper that provided a secondary point of vapor generation to provide energy savings in steam extraction and solvent regeneration. The project was executed over two budget periods. This involved testing of individual process components which included the advanced heat transfer packing and the dewatering membrane on UK CAER’s 30 liter per minute (L/min) CO 2 (3” Column) capture bench unit with simulated flue gas in the first budget period. Subsequent scaled-up testing of these components together with the split-feed configuration were also tested in UK CAER’s 0.1 MWth CO 2 capture unit with coal-derived flue gas in the second-budget period. Long term studies were done during this period to assess process and solvent performance over extended duration. Project partners Lawrence Livermore National Laboratory (LLNL) and Media & Process Technology (MPT) led the development efforts for the advanced packing material and dewatering membrane respectively. Data from the long term testing was used as input for an environmental, health and safety (EH&S) assessment for the process and scaled technology performed by ALL4 LLC. Trimeric Corporation also completed a techno-economic analysis (TEA) for the UK CAER technology which was compared to the DOE reference Case B12B. Tests on the 3” column capture unit showed that the advanced heat transfer packing could be used to lower the bulge temperature in the absorber, and this was also proven in the scaled testing in the 0.1 MWth CO 2 capture unit. The bulge temperature could be lowered by >10 °C, changing the temperature profile in the absorber, and showed potential to enhance absorption with the ability to tailor the profile to provide conditions suitable for a solvent’s properties and kinetics. Conditions for short term evaluation of a 19” zeolite dewatering membrane on the 3” column capture unit yielded desirable fluxes and sustained rejection rates of >80%. However, for the scaled testing of six membrane modules consisting of 21 parts of 31-inch-long membrane tubes in each bundle (surface area 0.3 m 2 ), over a more extended duration, similar rejection rates could not be achieved. With the split-feed of the rich stream to the stripper, improved heat recovery minimized waste heat exiting the top of the stripper. The stripper exhaust temperatures could be reduced by >10 °C; reducing the amount of water vaporization contributed to lowering the regeneration energy by ~ 15%. The energy benefit could be sustained from the long term monitoring of the solvent performance. The solvent properties were not significantly impacted over the long-term operations. The benefits of the UK CAER process demonstrated experimentally were mostly validated from the TEA comparing a commercial scale application of the technology to DOE reference Case B12B. The cost of CO 2 capture for the UK CAER technology was estimated to be ~$34.97/tonne of CO 2 captured; a reduction of 23% compared to Case B12B. The increase in cost of electricity was also shown to be 16% lower than that of Case B12B. The total parasitic demand was also shown to be 11% lower. The key drivers for the benefits are a result of the process intensification approaches employed in the UK CAER technology for enhanced solvent performance, effective heat recovery and improved energy performance. The EH&S assessment did not find any major environmental concerns or barriers to the full scale implementation of the technology.

20 FOSSIL-FUELED POWER PLANTS↗

TEAMER: Performance mapping of Re Vision's Persistance PTO

Contains datasets from experimental measurements that were used to validate Re Vision's Persistence PTO's efficiency and performance. These measurements were obtained using a dynamometer test bench setup. The data includes open-circuit voltage and loss measurements to validate machine characteristics, efficiency mapping tests to determine the generator's performance mapping, and efficiency mapping tests to determine the converter's efficiency over the feasible operating range. This data was collected between June 2023 and September 2023. The data was collected at the National Renewable Energy Laboratory's Flatirons Campus, Colorado, United States. The data was collected using NREL's 5-kW dynamometer test bench, equipped with a torque sensor and various voltage and current sensors fed to a dedicated data acquisition system. Units for the data are included in the data file headers for each data series. A text editor or spreadsheet software such as Excel is required to view the *.csv data. The data are also provided in *.mat files. To view data plots, a Matlab script with *.mat files are provided.

16 TIDAL AND WAVE POWER↗