Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Tomography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

Nonstationary phase boundary estimation in electrical impedance tomography using unscented Kalman filter

In this paper, an effective nonstationary phase boundary estimation scheme in electrical impedance tomography is presented based on the unscented Kalman filter. The inverse problem is treated as a stochastic nonlinear state estimation problem with the nonstationary phase boundary (state) being estimated online with the aid of unscented Kalman filter. This research targets the industrial applications, such as imaging of stirrer vessel for detection of air distribution or detecting large air bubbles in pipelines. Within the domains, there exist 'voids' having zero conductivity. The design variables for phase boundary estimation are truncated Fourier coefficients. Computer simulations and experimental results are provided to evaluate the performance of unscented Kalman filter in comparison with extended Kalman filter to show a better performance of the unscented Kalman filter approach.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Nonlinear regularization techniques for seismic tomography

The effects of several nonlinear regularization techniques are discussed in the framework of 3D seismic tomography. Traditional, linear, l{sub 2} penalties are compared to so-called sparsity promoting l{sub 1} and l{sub 0} penalties, and a total variation penalty. Which of these algorithms is judged optimal depends on the specific requirements of the scientific experiment. If the correct reproduction of model amplitudes is important, classical damping towards a smooth model using an l{sub 2} norm works almost as well as minimizing the total variation but is much more efficient. If gradients (edges of anomalies) should be resolved with a minimum of distortion, we prefer l{sub 1} damping of Daubechies-4 wavelet coefficients. It has the additional advantage of yielding a noiseless reconstruction, contrary to simple l{sub 2} minimization ('Tikhonov regularization') which should be avoided. In some of our examples, the l{sub 0} method produced notable artifacts. In addition we show how nonlinear l{sub 1} methods for finding sparse models can be competitive in speed with the widely used l{sub 2} methods, certainly under noisy conditions, so that there is no need to shun l{sub 1} penalizations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Expectation propagation for nonlinear inverse problems – with an application to electrical impedance tomography

In this paper, we study a fast approximate inference method based on expectation propagation for exploring the posterior probability distribution arising from the Bayesian formulation of nonlinear inverse problems. It is capable of efficiently delivering reliable estimates of the posterior mean and covariance, thereby providing an inverse solution together with quantified uncertainties. Some theoretical properties of the iterative algorithm are discussed, and the efficient implementation for an important class of problems of projection type is described. The method is illustrated with one typical nonlinear inverse problem, electrical impedance tomography with complete electrode model, under sparsity constraints. Numerical results for real experimental data are presented, and compared with that by Markov chain Monte Carlo. The results indicate that the method is accurate and computationally very efficient.

97 MATHEMATICS AND COMPUTING↗

A partially reflecting random walk on spheres algorithm for electrical impedance tomography

In this work, we develop a probabilistic estimator for the voltage-to-current map arising in electrical impedance tomography. This novel so-called partially reflecting random walk on spheres estimator enables Monte Carlo methods to compute the voltage-to-current map in an embarrassingly parallel manner, which is an important issue with regard to the corresponding inverse problem. Our method uses the well-known random walk on spheres algorithm inside subdomains where the diffusion coefficient is constant and employs replacement techniques motivated by finite difference discretization to deal with both mixed boundary conditions and interface transmission conditions. We analyze the global bias and the variance of the new estimator both theoretically and experimentally. Subsequently, the variance of the new estimator is considerably reduced via a novel control variate conditional sampling technique which yields a highly efficient hybrid forward solver coupling probabilistic and deterministic algorithms.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Uranium Isotopic Ratio Measurements of U3O8 Reference Materials by Atom Probe Tomography

We report results of measurements of isotopic ratios obtained with atom probe tomography on U3O8 reference materials certified for their isotopic abundances of uranium. The results show good agreement with the certified values. High backgrounds due to tails from adjacent peaks complicate the measurement of the integrated peak areas as well as the fact that only oxides of uranium appear in the spectrum, the most intense of which is doubly charged. In addition, lack of knowledge of other instrumental parameters, such as the dead time, may bias the results. Isotopic ratio measurements can be performed at the nanometer-scale with the expectation of sensible results. The abundance sensitivity and mass resolving power of the mass spectrometer are not sufficient to compete with magnetic-sector instruments but are not far from measurements made by ToF-SIMS of other isotopic systems. The agreement of the major isotope ratios is more than sufficient to distinguish most anthropogenic compositions from natural.

Atom Probe Tomography↗

In situ observation of the deformation and fracture of an alumina-alumina ceramic-matrix composite at elevated temperature using x-ray computed tomography

The deformation and fracture of a 0/90° Nextel 720 mullite fibre / alumina matrix ceramic-matrix composite material has been observed by in situ synchrotron x-ray computed micro-tomography at ambient temperature and at 1100 °C. A three-point loading configuration was used and samples were loaded monotonically until final fracture. Here, the flexural strength was found to be unaffected by temperature. 3D visualisation of the microstructure showed fracture occurred by propagation of internal cracks at stresses close to the flexural strength. Shear fractures propagated across fibre bundles that were oriented perpendicular to the flexural stress at both room temperature and 1100 °C. At the higher temperature, an additional failure mode of delamination was observed, that may arise from relaxation of thermal residual stresses and creep.

36 MATERIALS SCIENCE↗

Cone Beam Computed Tomography: The Challenges and Strategies in Its Application for Dose Accumulation

Online image guidance using cone beam computed tomography (CBCT) has greatly improved the geometric precision of radiotherapy. Changes in anatomy are common during a course of fractionated treatment, resulting in dose deviation from the planned distribution. There is increased interest in performing dose accumulation to compute the actual delivered dose and to adapt the treatment when necessary. This can be achieved by delineating the volume of interest and by generating “dose of the day” through dose computation on the CBCT. However, the image quality and the accuracy of the CT number of CBCT are deemed to be inferior to fan beam CT, which increases the uncertainty associated in this process. A review of literature was conducted to assess the reliability of and to examine strategies for overcoming the challenges in using CBCT for volume delineation and dose computation. The review demonstrates that the uncertainty varies across body sites, and different strategies have been recommended to generate comparable results to images from CT simulators. This facilitates a better understanding of the potential and the limitation of using CBCT for dose accumulation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effective Dose and Effective Risk from Post–Single Photon Emission Computed Tomography Imaging of the Lumbar Spine

Planar bone scans play an important role in the staging and monitoring of malignancy and metastases. Metastases in the lumbar spine are associated with significant morbidity; therefore, accurate diagnosis is essential. Supplementary imaging after planar bone scans is often required to characterize lesions; however, this is associated with additional radiation dose. This article provides information on the comparative effective dose and effective risk from supplementary lumbar spine radiographs, low-dose computed tomography (LDCT), and diagnostic CT (DCT).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Sparsity Prior Computed Tomography Reconstruction Using a Nonstandard Simultaneous X-ray Acquisition Model

In this article we systematically evaluate the performance of several state-of-the-art, sparsity prior computed tomography (CT) reconstruction algorithms, using a nonstandard simultaneous x-ray acquisition method. Sparsity prior is an efficient strategy in CT reconstruction, relying on iterative algorithms such as the algebraic reconstruction technique to produce a crude reconstruction, based on which sparse approximation is performed. The simultaneous x-ray acquisition model ensures rapid capture of x-rays; however, it captures a significantly fewer number of attenuation measurements, and the projections are nonuniform. We propose a weighted average filter in the reconstruction framework to ensure better quality reconstruction by minimizing the effect of nonuniform projections. The performance of the state-of-the-art algorithms is analyzed with and without weighted averaging before sparse approximation, in simulated and real environments. Experiments in the simulated environment are conducted with and without the presence of noise. From the results, it is evident that sparsity prior algorithms are capable of producing cross-sectional reconstruction using the simultaneous x-ray acquisition model, and better reconstruction quality is achievable with the incorporation of weighted averaging in the reconstruction framework.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Informing Patients About the Cancer Induction Risk of Undergoing Computed Tomography Imaging: The Radiographers' Perspective

In the midst of debates about the actual risk posed from computed tomography (CT) imaging, there is a general consensus that patients have a right to information. Despite this, communication of the potential cancer induction risk from CT scans is poor, leading to poor patient awareness. Without adequate awareness of any significant risks patients might be deprived of the opportunity to take part in their own care and, therefore, the opportunity for patient-centered care is missed. The aims of this study were to determine whether CT radiographers provide patients with information about cancer induction risks from CT scans and the rationale for their practices.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Impact of California Computed Tomography Dose Legislation: Survey of Radiologists

Highly publicized accounts of radiation overdose from computed tomography (CT) in both children and adults prompted legislation in California regulating CT dose. The purpose of this study was to determine the impact of the law (codified in Senate Bill [SB] 1237) on California radiologist practice patterns and understanding of CT dose.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

From Computed Tomography–Guided to Magnetic Resonance Imaging–Guided Intracavitary Brachytherapy for Cervical Cancer: What Do the Key Stakeholders Have to Say about the Transition?

International brachytherapy consortiums are advocating for the incorporation of magnetic resonance imaging (MRI) into the cervical brachytherapy process as a standard-of-care. Although some evaluations have been performed to quantify the effect on procedural time, little is known about the views and experiences of key stakeholders during the transition from computed tomography to MR-guided brachytherapy. This qualitative research project explored insights from key stakeholders related to a change in the gynaecologic brachytherapy process.

62 RADIOLOGY AND NUCLEAR MEDICINE↗