Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Time resolved imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

Soft x-ray images of the Laser Entrance Hole of NIC Hohlraums (paper, HTPD2012)

Hohlraums at the National Ignition Facility convert laser energy into a thermal x-radiation drive, which implodes the capsule, thus compressing the fuel. The x-radiation drive is measured with a low resolution, time-resolved x-ray spectrometer that views the hohlraum's laser entrance hole (LEH) at 37{sup o} to the hohlraum axis. This measurement has no spatial resolution. To convert this to the drive inside the hohlraum, the area and fraction of the measured x-radiation which comes from the region inside the hohlraum must be known. The size of the LEH is measured with the time integrated Static X-ray Imager (SXI) which view the LEH at 18{sup o} to the hohlraum axis. A soft x-ray image has been added to the SXI to measure the fraction of x-radiation inside the LEH's Clear Aperture in order to correct the measured radiation. A multilayer mirror plus filter selects an x-ray band centered at 870 eV, near the x-ray energy peak of a 300 eV blackbody. Results from this channel and corrections to the x-radiation drive are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Accessing Martian Fluvial and Lacustrine Sediments by Landing in Holden Crater, Margaritifer Sinus

Rover missions to the surface of Mars after MER 2003, are likely to be centered around focused geologic field mapping. One objective with high priority in selecting landing sites for these missions will be to characterize the nature, spatial distribution, internal structure, composition, and depositional history of exposed sedimentary layered deposits by visiting a number of distributed outcrops identified previously (and with a high degree of certainty) from orbit. These deposits may contain prebiotic material, even fossil organisms, but their primary value will be to enable an assessment of the planet's climate at the time they were emplaced. High resolution imaging from a mobile rover will enable the detailed study of these deposits over a wide area, their internal structure and mineralogy at distributed localities, and could resolve biologically-derived structures (such as stromatolite-like textures) if they are present. With the addition of a spectrometer, it should be possible to ascertain the presence of carbonates, sulfates, organics, water (liquid, frost, and bound water), as well as a variety of silicate minerals in the context of the collected imagery. Such a mission approach is directly relevant to future exploration of Mars, because it provides the geologic context comparable to what a field geologist visiting a site for the first time would acquire. Rover missions after MER will likely have much better targeting and hazard avoidance landing systems, enabling access to planimetrically-challenged sites of high scientific interest. These vehicles will also likely have greater mobility than MER, capable of driving greater distances in a shorter amount of time. Many scientists and mission planners have realized the need to design a rover whose mobility can be comparable to the dimensions of its 3-sigma landing error ellipse.

Parker, T. J.↗

Performance testing of the iX Cameras iSpeed 727 high-speed camera

This work evaluated the iX Cameras iSpeed 727, a commercial CMOS-based continuous- recording high-speed camera. Various parameters of importance in the scheme of accurate time-resolved measurements and photonic quantification have been measured under controlled conditions on the bench, using state-of-the-art instrumentation. We will detail the procedures and results of the tests laid out to measure sensor sensitivity, linearity, signal-to-noise ratio and image lag. We also looked into the electronic shutter performance and accuracy, as exposure time is of particular interest to high-speed imaging. The results of the tests show that this camera matches or exceeds the performance of competing units in most aspects, but that, as is the case for other high-speed camera systems, corrections are necessary to make full use of the image data from a quantitative perspective.

42 ENGINEERING↗

Low dose tomographic fluoroscopy: 4D intervention guidance with running prior

Purpose: Today's standard imaging technique in interventional radiology is the single- or biplane x-ray fluoroscopy which delivers 2D projection images as a function of time (2D+T). This state-of-the-art technology, however, suffers from its projective nature and is limited by the superposition of the patient's anatomy. Temporally resolved tomographic volumes (3D+T) would significantly improve the visualization of complex structures. A continuous tomographic data acquisition, if carried out with today's technology, would yield an excessive patient dose. Recently the authors proposed a method that enables tomographic fluoroscopy at the same dose level as projective fluoroscopy which means that if scanning time of an intervention guided by projective fluoroscopy is the same as that of an intervention guided by tomographic fluoroscopy, almost the same dose is administered to the patient. The purpose of this work is to extend authors' previous work and allow for patient motion during the intervention.Methods: The authors propose the running prior technique for adaptation of a prior image. This adaptation is realized by a combination of registration and projection replacement. In a first step the prior is deformed to the current position via affine and deformable registration. Then the information from outdated projections is replaced by newly acquired projections using forward and backprojection steps. The thus adapted volume is the running prior. The proposed method is validated by simulated as well as measured data. To investigate motion during intervention a moving head phantom was simulated. Real in vivo data of a pig are acquired by a prototype CT system consisting of a flat detector and a continuously rotating clinical gantry.Results: With the running prior technique it is possible to correct for motion without additional dose. For an application in intervention guidance both steps of the running prior technique, registration and replacement, are necessary. Reconstructed volumes based on the running prior show high image quality without introducing new artifacts and the interventional materials are displayed at the correct position.Conclusions: The running prior improves the robustness of low dose 3D+T intervention guidance toward intended or unintended patient motion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Particle Streak Velocimetry of Supersonic Nozzle Flows

A novel velocimetry technique to probe the exhaust flow of a laboratory scale combustor is being developed. The technique combines the advantages of standard particle velocimetry techniques and the ultra-fast imaging capabilities of a streak camera to probe high speed flows near continuously with improved spatial and velocity resolution. This "Particle Streak Velocimetry" technique tracks laser illuminated seed particles at up to 236 picosecond temporal resolution allowing time-resolved measurement of one-dimensional flows exceeding 2000 m/s as are found in rocket nozzles and many other applications. Developmental tests with cold nitrogen have been performed to validate and troubleshoot the technique with supersonic flows of much lower velocity and without background noise due to combusting flow. Flow velocities on the order of 500 m/s have been probed with titanium dioxide particles and a continuous-wave laser diode. Single frame images containing multiple streaks are analyzed to find the average slope of all incident particles corresponding to the centerline axial flow velocity. Long term objectives for these tests are correlation of specific impulse to theoretical combustion predictions and direct comparisons between candidate green fuels and the industry standard, monomethylhydrazine, each tested under identical conditions.

Willits, J. D.↗

Modification of carbon nanotubes with fluorinated ionic liquid for improving processability of fluoro-ethylene-propylene

Fluorinated ionic liquid (F-IL), 1-(3-perfluorooctylpropyl)-3-methylimidazolium bis(perfluoroethylsufonyl)amine, had been successfully prepared and employed to modify multi-wall carbon nanotubes (MWCNTs) for improving the processability of fluoro-ethylene-propylene (FEP). The thermally decomposed temperature of F-IL was higher than 350 °C measured by thermal gravimetric analysis (TGA) which indicated that the fluorinated ionic liquid could be suitable for melting blend with FEP (blending at 290 °C) by a twin-screw extruder. Through “cation-π” interaction between the imidazolium cation of F-IL and the graphene surface of MWCNTs, MWCNTs can be modified with F-IL and used as nanofillers to improve the dispersity of MWCNTs in fluorocopolymer FEP verified by SEM images of the FEP nanocomposite. The structural characterization and mechanical property of FEP nanocomposite during the deformation were investigated by tensile experiments and simultaneous time-resolved wide-angle X-ray diffraction (WAXD) and small-angle X-ray scattering (SAXS) techniques.

36 MATERIALS SCIENCE↗

In Situ Time-Resolved X-ray Scattering Study of Isotactic Polypropylene in Additive Manufacturing

In this study, we used a specially designed apparatus, which collects simultaneous temperature and X-ray scattering data, to perform in situ measurements of the filament during MatEx 3D printing. The data show that the MatEx 3D printing extrusion process provides sufficient shear to form shish-kebab structures, which initially nucleate at the filament surface and spread into the filament core. Time-resolved measurements show that the kebab component near the surface relaxes after deposition of the second filament and enhances chain diffusion across the interface. SEM images indicate near complete interfacial merging of the filaments, which results in excellent mechanical properties.

36 MATERIALS SCIENCE↗

Multi-energy SXR cameras for magnetically confined fusion plasmas (invited)

A compact multi-energy soft x-ray camera has been developed for time, energy and space-resolved measurements of the soft-x-ray emissivity in magnetically confined fusion plasmas. Multi-energy soft x-ray imaging provides a unique opportunity for measuring, simultaneously, a variety of important plasma properties (T e , n Z , ΔZ eff , and n e,fast ). The electron temperature can be obtained by modeling the slope of the continuum radiation from ratios of the available brightness and inverted radial emissivity profiles over multiple energy ranges. Impurity density measurements are also possible using the line-emission from medium- to high-Z impurities to separate the background as well as transient levels of metal contributions. As a result, this technique should be explored also as a burning plasma diagnostic in-view of its simplicity and robustness.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

X-Ray Studies of Delphi Diesel Injection Systems

This CRADA explored the performance of two different models of Delphi diesel injectors. For each injector, the valve needle motion was imaged from two lines of sight at three different injection pressures to characterize its 3D motion. The needle lift was quite repeatable, and followed the expected trend of faster lift with higher injection pressure. In addition, it was observed that the maximum lift increased with injection pressure, even after the valve reached its mechanical limit, indicating that the increased fuel pressure was causing compression or bending of the needle. The off-axis motion of the needle was found to be significant in both measurement planes, though it was very repeatable from one injection event to the next. The effect of ambient pressure on the needle motion was explored at an injection pressure of 400 bar, with ambient pressure up to 15 bar. No effect of the elevated ambient pressure on the needle lift was observed. High-speed x-ray imaging of the spray as it first emerges from the injector nozzle was performed in order to characterize the near-nozzle morphology and breakup of the spray. While imaging was successful at low ambient pressure, the contrast of the images was reduced at high ambient pressures, and quantitative measurements of the morphology were precluded. The near-nozzle fuel distributions were measured using time-resolved x-ray radiography for three injection pressures at an ambient pressure of 33 bar. Increasing injection pressure caused the fuel distribution to narrow, as measured by the Full Width at Half Maximum of the mass distributions. The fuel distributions were quantified for the two injectors at each measurement condition, quantifying the impact that each experimental parameter has on the near-nozzle fuel and air mixture preparation.

42 ENGINEERING↗

DITAC FASPAX / ASIC Development [Slides]

FASPAX is an integrating detector with wide dynamic range and high burst frame rate. The detector uses in-pixel analog storage to acquire a burst of images at frame rates of up to 13 MHz, with further provision for user-defined timing schemes. The detector allows the synchrotron light source time-resolved community to access the machine's designed temporal resolution for particular fill patterns.

43 PARTICLE ACCELERATORS↗

Landslides in Valles Marineris, Mars

The morphology of the landslides in the Martian equatorial troughs, the geologic structure of the troughs, the time of emplacement, the similarity to terrestrial landslides, and the origin and mechanism of transport are analyzed. About 35 large landslides well-resolved on Viking images were examined, and it is found that the major landslides cover 31,000 sq km of the trough floors, and individual slides range in area from 40 to 7000 sq km. The morphologic variations of the landslides can be attributed mainly to their degree of confinement on trough floors. Many prominent landslides appear to be of similar age and were emplaced after a major faulting that dropped the trough floors. Most sliding occurred after the created scarps were dissected into spurs, gullies, and tributary canyons. Emplacement of the landslides approximately coincided with a late episode of major eruptive activity of the Tharsis volcanoes, and it is suggested that the slides may have originated as gigantic mudflows with slump blocks at their heads. The large size of many landslides is due to the fault scarps as high as 7 km on which they formed in the absence of vigorous fluvial erosion. The landslides suggest that Mars is earthlike in some respects, which may be important for further evaluations.

Lucchitta, B. K.↗

Measurements of the Flow in the Vicinity of an Additively Manufactured Turbine Leading-Edge Using X-Ray Particle Tracking Velocimetry

X-ray particle tracking velocimetry (PTV) is performed, for the first time, to measure the velocity field inside a leading-edge of a turbine blade made by laser-additive-manufacturing (LAM) process. The traditional showerhead holes were replaced by a porous matrix in the leading-edge. The flow through such a leading-edge piece cannot be faithfully recreated by traditional prototype testing methods due to the surface roughness and imperfections caused by LAM process. Hence, direct measurement is the only option. However, it is difficult to measure flow inside such pieces with traditional velocimetry measurements due to the existence of metallic walls. Moreover, small internal size and high flow speeds call for a measurement technique with high spatial and temporal resolutions. To address these issues, we performed time-resolved X-ray PTV using the Advanced Photon Source (APS) synchrotron facility at the Argonne National Laboratory (ANL). A hydraulic system was constructed to run water, mixed with seeding particles, through the leading-edge piece. A high-speed camera captured the images of the seeding particles, which were later processed to create particle tracks. The time-averaged velocity field showed distinct pairs of vortices located in front of the porous outlet inside the leading-edge piece. The inlet channel showed reversed flow due to partial obstruction by the porous inlet of the test piece. Such knowledge of the flow field inside a leading-edge of a turbine blade will help us to design better cooling paths leading to higher cooling efficiency and increased life-span of a turbine blade.

42 ENGINEERING↗

2D image of local density and magnetic fluctuations from line-integrated interferometry-polarimetry measurements

Combined polarimetry-interferometry capability permits simultaneous measurement of line-integrated density and Faraday effect with fast time response (∼1 μs) and high sensitivity. Faraday effect fluctuations with phase shift of order 0.05° associated with global tearing modes are resolved with an uncertainty ∼0.01°. For physics investigations, local density fluctuations are obtained by inverting the line-integrated interferometry data. The local magnetic and current density fluctuations are then reconstructed using a parameterized fit of the polarimetry data. Reconstructed 2D images of density and magnetic field fluctuations in a poloidal cross section exhibit significantly different spatial structure. Combined with their relative phase, the magnetic-fluctuation-induced particle transport flux and its spatial distribution are resolved.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

NO TRANSITION DISK? INFRARED EXCESS, PAH, H{sub 2}, AND X-RAYS FROM THE WEAK-LINED T TAURI STAR DoAr 21

As part of a program to understand disk dispersal and the interplay between circumstellar disks and X-ray emission, we present new high-resolution mid-infrared (IR) imaging, high-resolution optical spectroscopy, and Chandra grating X-ray spectroscopy of the weak-lined T Tauri star DoAr 21. DoAr 21 (age <10{sup 6} yr and mass {approx}2.2 M {sub sun} based on evolutionary tracks) is a strong X-ray emitter, with conflicting evidence in the literature about its disk properties. It shows weak but broad Halpha emission (reported here for the first time since the 1950s); polarimetric variability; polycyclic aromatic hydrocarbon (PAH) and H{sub 2} emission; and a strong, spatially resolved 24 {mu}m excess in archival Spitzer photometry. Gemini sub-arcsecond-resolution 9-18 {mu}m images show that there is little or no excess mid-IR emission within 100 AU of the star; the excess emission is extended over several arcseconds and is quite asymmetric. The extended emission is bright in the ultraviolet (UV)-excited lambda = 11.3 {mu}m PAH emission feature. A new high-resolution X-ray grating spectrum from Chandra shows that the stellar X-ray emission is very hard and dominated by continuum emission; it is well fit by a multi-temperature thermal model, typical of hard coronal sources, and shows no evidence of unusually high densities. A flare during the X-ray observation shows a temperature approaching 10{sup 8} K. We argue that the far-UV emission from the transition region is sufficient to excite the observed extended PAH and continuum emission, and that the H{sub 2} emission may be similarly extended and excited. While this extended emission may be a disk in the final stages of clearing, it also could be more akin to a small-scale photodissociation region than a protoplanetary disk, highlighting both the very young ages (<10{sup 6} yr) at which some stars are found without disks and the extreme radiation environment around even late-type pre-main-sequence stars.

79 ASTRONOMY AND ASTROPHYSICS↗

Soft x-ray images of the laser entrance hole of ignition hohlraums

Hohlraums are employed at the national ignition facility to convert laser energy into a thermal x-radiation drive, which implodes a fusion capsule, thus compressing the fuel. The x-radiation drive is measured with a low spectral resolution, time-resolved x-ray spectrometer, which views the region around the hohlraum's laser entrance hole. This measurement has no spatial resolution. To convert this to the drive inside the hohlraum, the size of the hohlraum's opening ('clear aperture') and fraction of the measured x-radiation, which comes from this opening, must be known. The size of the clear aperture is measured with the time integrated static x-ray imager (SXI). A soft x-ray imaging channel has been added to the SXI to measure the fraction of x-radiation emitted from inside the clear aperture. A multilayer mirror plus filter selects an x-ray band centered at 870 eV, near the peak of the x-ray spectrum of a 300 eV blackbody. Results from this channel and corrections to the x-radiation drive are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cellular Oxygen and Nutrient Sensing in Microgravity Using Time-Resolved Fluorescence Microscopy

Oxygen and nutrient sensing is fundamental to the understanding of cell growth and metabolism. This requires identification of optical probes and suitable detection technology without complex calibration procedures. Under this project Microcosm developed an experimental technique that allows for simultaneous imaging of intra- and inter-cellular events. The technique consists of frequency-domain Fluorescence Lifetime Imaging Microscopy (FLIM), a set of identified oxygen and pH probes, and methods for fabrication of microsensors. Specifications for electronic and optical components of FLIM instrumentation are provided. Hardware and software were developed for data acquisition and analysis. Principles, procedures, and representative images are demonstrated. Suitable lifetime sensitive oxygen, pH, and glucose probes for intra- and extra-cellular measurements of analyte concentrations have been identified and tested. Lifetime sensing and imaging have been performed using PBS buffer, culture media, and yeast cells as a model systems. Spectral specifications, calibration curves, and probes availability are also provided in the report.

Szmacinski, Henryk↗

DETERMINING THE STRUCTURE OF SOLAR CORONAL LOOPS USING THEIR EVOLUTION

Despite significant progress in understanding the dynamics of the corona, there remain several unanswered questions about the basic physical properties of coronal loops. Recent observations from different instruments have yielded contradictory results about some characteristics of coronal loops, specifically as to whether the observed loops are spatially resolved. In this paper, we examine the evolution of coronal loops through two extreme-ultraviolet filters and determine if they evolve as a single cooling strand. We measure the temporal evolution of eight active region loops previously studied and found to be isothermal and resolved by Aschwanden and Nightingale. All eight loops appear in 'hotter' TRACE filter images (Fe XII 195 A) before appearing in the 'cooler' (Fe IX/Fe X 171 A) TRACE filter images. We use the measured delay between the two filters to calculate a cooling time and then determine if that cooling time is consistent with the observed lifetime of the loop. We do this twice: once when the loop appears (rise phase) and once when it disappears (decay phase). We find that only one loop appears consistent with a single cooling strand and hence could be considered to be resolved by TRACE. For the remaining seven loops, their observed lifetimes are longer than expected for a single cooling strand. We suggest that these loops could be formed of multiple cooling strands, each at a different temperature. These findings indicate that the majority of loops observed by TRACE are unresolved.

79 ASTRONOMY AND ASTROPHYSICS↗

A large field-of-view high-resolution hard x-ray microscope using polymer optics

Here, we present an effective approach using a matched pair of polymer-based condenser-objective lenses to build a compact full-field X-ray microscope with a high spatial resolution. A unique condenser comprising arrays of high-aspect-ratio prisms with equilateral cross-section is used for uniformly illuminating samples over a large field of view (FoV) from all angles, which match the acceptance of an objective made of interdigitated orthogonal rows of one-dimensional lenses. State-of-the-art Talbot grating interferometry used to characterize these lenses for the first time revealed excellent focusing properties and minimal wave-front distortions. Using a specific lens-pair designed for 20 keV X-rays, short-exposure times, and image registration with a cross-correlation technique, we circumvent vibrational instabilities to obtain distortion-free images with a uniform resolution of 240 nm (smallest resolvable line pair) over a large FoV, 80 × 80 µm 2 in extent. The results were contrasted with those collected under illumination using commercial two-dimensional parabolic lenses with a smaller FoV. This approach implemented on a diffractometer would enable diffraction-contrast or dark-field microscopy for fast observations of ‘mesoscopic’ phenomena in real space complementing reciprocal-space studies using diffraction on the same instrument.

47 OTHER INSTRUMENTATION↗