Bench Scale Testing of Next Generation Hollow Fiber Membrane Modules

This project seeks to develop a next generation membrane material (PI-2) for application in Air Liquide’s (AL) hybrid process. Combining the cold membrane operation with an integrated CO 2 Compression and Purification Unit (CPU) significantly reduces the overall cost of CO 2 capture. The proposed work will accelerate the membrane bundle fabrication, scale-up and performance validation of this new material. The proposed novel membrane development, combined with the results of the previous Cold Membrane Project, will provide the best opportunity for AL to meet the long term development targets of the DOE with respect to timing, cost, and performance for CO 2 capture. Our previous field test program (DE-FE0013163) showed promising results for the hybrid process utilizing the existing commercial AL membrane bundles (PI-1 material). The project work has also shown the potential for significant improvements through initial laboratory tests with the novel material (PI-2). The initial PI-2 results show a step-change in membrane permeance. This will enable further reduction in the cost of CO 2 capture by reducing the number of membrane modules and associated equipment in the system. In order to capture this value, however, the new material needs to be validated by field testing of large bundles, representative of commercial production. Lastly, a comprehensive evaluation of novel hybrid processes and costs needs to be completed to ensure optimal use of this improved material performance. The current project seeks to develop this next generation membrane to TRL 5 (approximately 600 - 1,000 Nm3/h flue gas, 350 - 600 scfm, 0.2 - 0.3 MWe equivalent). Air Liquide manufacturing methodology will be applied to fabricate prototype (4”) membrane modules from PI-2 material. Once the manufacturing methods prove reliable with the new material, and performance is demonstrated in line with expectation, 6” commercial scale bundles will be fabricated. Recognizing that a low cost membrane solution by itself may not meet DOE’s LCOE target for CO 2 capture, we will also perform simulation studies of novel hybrid processes in combination with the next generation membrane technology. This approach has the best potential for exceeding the DOE targets. The best evaluation of the new commercial units will be performance testing under real flue gas at the NCCC. Finally, a rigorous TEA, which incorporates the novel process studies and field performance, will be completed.

36 MATERIALS SCIENCE↗

High Altitude Electromagnetic Pulse Testing of Photovoltaic Modules

This report details the test setup, process, and results for radiated susceptibility testing of multicrystalline silicon photovoltaic (PV) modules as part of the EMP-Resilient Electric Grid Grand Challenge Laboratory Directed Research and Development (LDRD) project at Sandia National Laboratories. Testing was conducted over October 10-17, 2019, where 8 photovoltaic modules were exposed to E1 transient pulses with peak field levels up to 100 kV/m. Modules were terminated in a resistive load representing connected components. State of health testing conducted via I-V curve tracing of the photovoltaic modules showed no observable loss of device function due to large electric field transients. Differential mode currents were measured on the order of 10's of amps for up to a microsecond following the radiated field pulse. Common mode currents took the form of a damped sinusoid with a maximum peak of 10's to 100's of amps with a resonance near 60 MHz.

14 SOLAR ENERGY↗

Report on Oak Ridge National Laboratory Testing of Ambient Cure TransPowr E3X®

A key to industry acceptance of a new technology is extensive validation in field trials. The Powerline Conductor Accelerated Test facility (PCAT) at Oak Ridge National Laboratory (ORNL) is specifically designed to evaluate the performance and reliability of novel overhead conductor and conductor instrumentation under field conditions. The facility is set up to capture large amounts of data during testing. General Cable used the ORNL PCAT facility to validate the performance of TransPowr® with Ambient Cure E3X™ Technology—a standard overhead conductor with a high emissivity, low absorptivity ambient cure surface coating. Extensive testing has demonstrated a significant improvement in conductor performance across a wide range of operating temperatures with respect to uncoated conductor of the same type, indicating that E3X Technology can provide a reduction in temperature, a reduction in sag, and an increase in ampacity when applied to the surface of any overhead conductor. This report provides results of that testing.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Swab Tensile Testing and Procedures

This tensile test is to mimic the worst-case scenario of the swab being caught on an obstruction when being pulled out of the nasopharyngeal space. It is to determine how much tensile force the swab can withstand without breaking. A variety of different swabs (different materials and different geometries) were tested using the protocol outlined in Section 2 (Tensile Testing Procedure). Not all of the swabs were pre-treated using the Autoclave. For those swabs that were pre-treated using the Autoclave, the tensile tests were performed within 6 hours of completion of the Autoclave pre-treatment, unless otherwise noted. The FormLabs-USF and FormLabs-Northwell were printed at LLNL using FormLabs Surgical Grade V1 Resin on a Form 3B Printer. Results Summary: All FormLabs design and treatment variations (e.g. autoclaving and “aging”) had higher tensile strength compared commercial swabs. Autoclaving degraded the tensile strength. “Aging” after autoclaving improved the tensile strength. “Aging” without autoclaving degraded the tensile strength. No differences were observed in tensile strength with different autoclaving protocols. No significant differences were observed in tensile strength for different batches.

59 BASIC BIOLOGICAL SCIENCES↗

SRNL Coulometer for LANL - SRNL-Testing 2020 (Final Report)

SRNL fabricated two coulometers that have been delivered to LANL. All testing for electrical components is performed by R&D engineering and the results are attached to this report. Instrument testing for the first instrument was completed on August 2018 and installation at LANL was completed February 2019. This report addresses testing performed at FH Analytical Laboratory for the second instrument that arrived at LANL on June 5th, 2020. The testing is performed using Plutonium working standards. The instrument was kept in a radiologically clean area. The component calibration of the second LANL coulometer was completed in SRNL Building 723-A.

47 OTHER INSTRUMENTATION↗

Validation of pooling strategies of clinical COVID-19 samples for more efficient diagnostic testing

Pooling of COVID-19 clinical samples can offer significant reduction in reagents, time, and labor needed to test large numbers of clinical samples. Especially for testing asymptomatic and return-towork/ school cases, where the prevalence of COVID-19 may be relatively low, large groups of clinical samples can be classified as negative with a single test, with no need to test every sample individually. LANL has performed validation for two different pooling strategies to assess diagnostic assay sensitivity in pooled samples compared to the clinical positive sample alone. (1) Pooling study - Determine diagnostic assay sensitivity in pooled samples with ratios of 1:5, 1:10, 1:20, and 1:30 positive to negative clinical samples. (2) Reloading study - Determine diagnostic assay sensitivity in reloading of multiple clinical samples through a Qiagen column in 5x, 10, and 20x sample volumes (1 positive plus 4, 9, and 19 negative samples).

59 BASIC BIOLOGICAL SCIENCES↗

FY20 Update on Brine Availability Test in Salt. Revision 4

This report summarizes the 2020 fiscal year (FY20) status of the borehole heater test in salt funded by the US Department of Energy Office of Nuclear Energy (DOE-NE) Spent Fuel and Waste Science & Technology (SFWST) campaign. This report satisfies SFWST level-two milestone number M2SF-20SNO10303032. This report is an update of an August 2019 level-three milestone report to present the final as-built description of the test and the first phase of operational data (BATS la, January to March 2020) from the Brine Availability Test in Salt (BATS) field test.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

2020 LANL Contributions to the BATS Test in WIPP

The DOE Office of Nuclear Energy (DOE-NE) repository research and development program seeks to provide a sound technical basis for multiple viable disposal options, increase confidence in the robustness of generic disposal concepts, and develop science and engineering tools needed to support disposal concept implementation. Sandia, Los Alamos, and Lawrence Berkeley National labs are conducting research into salt, which includes the Brine Availability Test in Salt (BATS) field test at the Waste Isolation Pilot Plant (WIPP), a DOE Office of Environmental Management facility. BATS is leveraging the existing infrastructure associated with the WIPP to advance science informing generic disposal concepts. BATS is an ongoing heated borehole experiment being conducted in the WIPP underground. The goal of this experiment is to reduce the uncertainty associated with spent nuclear fuel disposition in geologic salt formations. The BATS experiments is designed to accomplish this by increasing our understanding of brine migration in salt, assessing damaged zones from mining and drilling, simulating a post-closure environment, confirming salt properties, and providing data for model validation. Phased testing for generic salt repository R&D was proposed in 2015. Subsequently, borehole thermal testing was developed as a first step in this process. This document summarizes the work conducted on the BATS experiment during fiscal year 2020 with an emphasis on the contributions by Los Alamos National Lab.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Cylinder Test

In 1941 G.I. Taylor proposed the cylinder test as an experiment to determine the properties of explosive products. The test consists of a hollow metal cylinder containing an unreacted cylindrical charge of explosives. The charge is detonated at one end of the cylinder and, as the detonation wave propagates, the product gas expands behind it. As the product gas is produced, the pressure acting on the metal increases and begins to push the walls outward. Consider the time at which the detonation wave has reached the halfway point between the two ends of the cylinder. In front of the wave nothing has changed and the metal tube has the same initial radius. Behind the wave, the radius of the tube has expanded. The farther behind the wave a section of tube is, the larger its radius has become. The longer the wall is exposed to the pressurized gas, the more it expands, so that the radius is largest where the detonation was initiated. The metal most commonly used for this experiment is soft copper. Its material properties are well known and soft copper is also easy to shape with precision machining. During the cylinder test the radial expansion of the cylinder is measured over time and this data is used to determine the amount of work applied to the cylinder wall by the product gas as a function of time. Since volume increases in this problem, the time dependence can be seen as a volume dependence. The volume dependent work yields a path in thermodynamic space. The cylinder test experiment can be modeled using simulation. The simulation gives you the answer, but it cannot tell you why. The goal of the proposed work is to use analytic analysis methods to give insight into the simulation solution.

36 MATERIALS SCIENCE↗

NRIC EBR-II Test Bed Pre-Conceptual Design Report

Authorized by the Nuclear Energy Innovation Capabilities Act (NEICA), the National Reactor Innovation Center (NRIC) provides private sector technology developers access to strategic infrastructures and assets for commercial nuclear energy research, development, demonstration, and deployment activities. The mission is to support a timely and cost-effective path to the licensing and commercialization of new nuclear energy systems. To meet these needs, NRIC is developing two test beds at Idaho National Laboratory (INL). The ZPPR Test bed (ZTB) and the EBR-II Test bed (ETB). The EBR-II test bed will support the demonstration of systems that operate at less than 10 MWt. The baseline objective is for the EBR-II Dome to act as a safety significant containment structure capable of siting reactors that utilize Safeguards Category 4 material for operations. The major areas addressed in the pre-conceptual design include: • Installation of an access door • Electrical Power • Heat Removal • Ventilation in the Dome • Module handling system Along with the design for ETB a concept of operations (COP) has also been developed. The COP is intended to facilitate a common understanding of ideas, challenges, and issues. As systems continue to evolve in complexity System Engineers and Project Directors will utilize the COP to develop and sustain a common vision of the system for stakeholders.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

FOSWEC dynamics and controls test report

This report describes the testing of a model scale wave energy converter. This device, which uses two aps that pivot about a central platform when excited by waves, has a natural frequency within the range of the waves by which it is excited. The primary goal of this test was to assess the degree to which previously developed modeling, experimentation, and control design methods could be applied to a broad range of wave energy converter designs. Testing was conducted to identify a dynamic model for the impedance and excitation behavior of the device. Using these models, a series of closed loop tests were conducted using a causal impedance matching controller. This report provides a brief description of the results, as well as a summary of the device and ex- perimental design. The results show that the methods applied to this experimental device perform well and should be broadly applicable.

16 TIDAL AND WAVE POWER↗

Preliminary Test Design and Plan for a Canister Deposition Field Demonstration

This report provides a high-level test plan for deploying three commercial 32PTH2 spent nuclear fuel (SNF) canisters inside NUHOMS Advanced Horizontal Storage Modules (AHSM) from Orano (formerly Transnuclear Inc.). The details contained in this report represent the best designs and approaches explored for testing as of this publication. Given the rapidly developing nature of this test program, some of these plans may change to accommodate new objectives or adapt in response to conflicting requirements. The goal of the testing is to collect highly defensible and detailed surface deposition measurements from the surface of dry storage systems in a marine coastal environment to guide chloride-induced stress corrosion crack (CISCC) research. To facilitate surface sampling, the otherwise highly prototypic dry storage systems will not contain SNF but rather will be electrically heated to mimic the thermal-hydraulic environment. Instrumentation throughout the canister, storage module, and environment will provide an extensive amount of information for the use of model validation. Manual sampling over a comprehensive portion of the canister surface at regular time intervals will offer a high-fidelity quantification of the conditions experienced in a harsh yet realistic environment.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The Grey Zone Test Range Integrated Urban Simulation Environment

Sandia National Laboratories is part of the government test and evaluation team for the Defense Advanced Research Projects Agency Collection and Monitoring via Planning for Active Situational Scenarios program. The program is designed to better understand competition in the area between peace and conventional conflict when adversary actions are subtle and difficult to detect. For the purposes of test and evaluation, Sandia conducted a range of activities for the program: creation of the Grey Zone Test Range; design of the data stream for a user experiment conducted with U.S. Indo-Pacific Command; design, implementation, and execution of the formal evaluation; and analysis and summary of the evaluation results. This report details Sandia's activities and provides additional information on the Grey Zone Test Range urban simulation environment developed to evaluate the performer technologies.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

PHELIX Shallow Cassette Liner Performance Tests 1 and 2 Post-Shot Simulation Report

PHELIX shallow cassette liner performance Tests 1 (PHELIX No. 151) and 2 (PHELIX No. 156) were conducted on August 07, 2020, and September 16, 2020, respectively. The primary purpose for these tests was to assess liner performance within the new shallow cassette PHELIX design configuration. Specific goals included: (1) an assessment of liner performance in terms of velocity and symmetry (both axial and azimuthal), and (2) an assessment of our ability to accurately predict liner performance. Test 1 was conducted with a driving potential of 70 kV. Test 2 was conducted with a driving potential of 75 kV.

42 ENGINEERING↗

Dip leg plug formation evaluation and abatement testing in support of the H-Canyon accelerated basin de-inventory

As requested in the Technical Task Request (TTR), the Savannah River National Laboratory (SRNL) performed testing on the current typical bubbler dip leg design used in the H-Area Canyon (HCA). The TTR has a functional classification of General Services. Testing was initiated to ascertain if the plugging described in the TTR could be reproduced and, if so, to obtain general metrics on the resulting plugging dynamics, and evaluate possible mitigating methods, including design changes and cleaning/purging protocols. The bubblers were to be suspended in a simulant typical of H-Canyon solutions containing aluminum nitrate and silica at a temperature of 25°C using a nominal bubbler air flowrate of 7.5 SCFH. Emphasis was placed on minimizing equipment changes necessary to accomplish the mitigations, as equipment changes in the existing facility would be costly. Testing evolved into four (4) phases, concluding that plugging could indeed be reproduced (believed to be attributed to localized evaporation and bridging of crystals in the dip legs). During testing, plug formation information was obtained, including time, pressure, and temperature traces leading to plugging were defined; solution compositions leading to plugging were determined, and various physical characteristics (visual and mechanical) of the crystallized plug were obtained.

42 ENGINEERING↗

Test Plan for Investigation of Hydrogen Generation in SNF Canisters

This report presents a test plan to investigate radiolytic hydrogen generation in spent nuclear fuel (SNF) canisters containing Zr-based cladding materials. The initial primary contributor to the generation of radiolytic hydrogen is estimated to be the residual physisorbed water on the ZrO 2 film, post-dry out. Over the longer term the primary hydrogen source is associated with the aluminum hydroxides and water vapor. The proposed testing to be conducted in FY22 would consist of lab-scale testing on non-radioactive surrogates of oxidized ZIRLO tubing and unalloyed zirconium using a miniature steel canister (“mini-canister") designed to allow intermittent, in-situ sampling of the canister gas during irradiation. The mini-canister approach for irradiation with in-situ monitoring system was used in a recent and on-going study [McNamara and Verst, 2020a & 2020b; Verst et al., 2021] to measure radiolytic hydrogen generation from aluminum SNF cladding surrogate materials. This proposed testing will form part of the overall materials performance evaluation of the commercial SNF-in-canister system and is part of the technical bases for their continued safe dry storage

08 HYDROGEN↗

RAVEN regression tests' description

Regression tests for the Python RAVEN framework are found in raven/tests/framework. There is a hierarchy of folders with tests collected by similar testing. Every test is described in a special XML node (< TestInfo >) within the < Simulation > block.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

COVID-19 Testing R&D (Final Report)

Eleven Labs within the US Department of Energy (DOE), National Virtual Biotechnology Laboratory (NVBL), came together as a team to address significant R&D gaps in COVID-19 testing. Beginning in March 2020, the NVBL COVID Testing Team developed an R&D agenda, worked with DOE and other agencies to set priorities, and collaborated to deliver timely results. Priority was given to quick implementation as well as development of novel capabilities for immediate and evolving pandemic needs without placing additional burden on operational performers. Priority elements capitalized on DOE National Laboratory strengths and expertise. The Team delivered: testing and evaluation that enabled decisions on testing options, forwardleaning approaches to prepare for future scale-up needs, and models and experiments that supported prioritization of diagnostic and therapeutic candidates.