Overflow Juncture Flow Computations Compared with Experimental Data

NASA’s Transformational Tools and Technologies Project (T(cu.) is supporting a substantial effort to investigate the formation and origin of separation bubbles found on wing-body juncture zones: the Juncture Flow experiment. The first phase of the Juncture Flow experiment, performed in NASA Langley’s 14- by 22-Foot Subsonic Tunnel, has been completed. This paper documents the CFD analysis done in conjunction with the experiment. Comparisons between CFD simulations and wind tunnel experimental results will be shown. Oil flow results, surface pressure cuts, velocity profiles, and Reynolds stress profiles will be compared. Preliminary results analyzing the effect of grid resolution, wind tunnel walls, and turbulence models on the above data will be presented. The results are not meant to be a validation study, but more as an evaluation of the current status of Reynolds averaged Navier Stokes (RANS) CFD simulations.

Lee, Henry C.↗

Prospects for Nonlinear Laser Diagnostics in the Jet Noise Laboratory

Two experiments were conducted to test whether optical methods, which rely on laser beam coherence, would be viable for off-body flow measurement in high-density, compressible-flow wind tunnels. These tests measured the effects of large, unsteady density gradients on laser diagnostics like laser-induced thermal acoustics (LITA). The first test was performed in the Low Speed Aeroacoustics Wind Tunnel (LSAWT) of NASA Langley Research Center's Jet Noise Laboratory (JNL). This flow facility consists of a dual-stream jet engine simulator (with electric heat and propane burners) exhausting into a simulated flight stream, reaching Mach numbers up to 0.32. A laser beam transited the LSAWT flow field and was imaged with a high-speed gated camera to measure beam steering and transverse mode distortion. A second, independent test was performed on a smaller laboratory jet (Mach number < 1.2 and mass flow rate < 0.1 kg/sec). In this test, time-averaged LITA velocimetry and thermometry were performed at the jet exit plane, where the effect of unsteady density gradients is observed on the LITA signal. Both experiments show that LITA (and other diagnostics relying on beam overlap or coherence) faces significant hurdles in the high-density, compressible, and turbulent flow environments similar to those of the JNL.

Herring, Gregory C.↗

Approach to establishing the effect of aeroelasticity on aerodynamic characteristics of the space shuttle orbiter

The static aeroelastic effects on the longitudinal stability and elevon/aileron effectiveness of the space transportation system (STS) Space Shuttle orbiter were estimated by a simplified approach called the elevon torsional stiffness (ETS) method. This method employs rigid model wind tunnel test results to predict aeroelastic effects. Lateral/directional stability and rudder effectiveness were based on results of a wind tunnel test in which a flexible tail model was used. Comparisons with selective flight data are made in this paper. Results of correlations with flight data (although limited at the present time) verify the predicted aeroelastic effects for the orbiter. The orbiter's structural characteristics are such that the effects of aeroelasticity, whether estimated using analytical techniques or simplified methods, do not appear to affect the vehicle performance to any great extent. The large amount of scatter in the flight-extracted data made verification of the aeroelastic corrections very difficult. Generally, the simplified elevon torsional stiffness method provided better correlation with flight test results than he analytical method and reduced the verification effort and cost.

Schlosser, D. C.↗

Comparison of analytical and wind-tunnel results for flutter and gust response of a transport wing with active controls

Two flutter suppression control laws wre designed and tested on a low speed aeroelastic model of a DC-10 derivative wing. Both control laws demontrated increases in flutter speed in excess of 25 percent above the passive wing flutter speed. In addition, one of the control laws was effective in reducing loads due to turbulence generated in the wind tunnel. The effect of variations in gain and phase on the closed-loop performance was measured and is compared with predictions. In general, both flutter and gust response predictions agree reasonably well with experimental data.

Abel, I.↗

Analysis of a six-component, flow-through, strain-gage, force balance used for hypersonic wind tunnel models with scramjet exhaust flow simulation

The thermal effects of simulant gas injection and aerodynamic heating at the model's surface on the measurements of a non-watercooled, flow through balance were investigated. A stainless steel model of a hypersonic air breathing propulsion cruise missile concept (HAPCM-50) was used to evaluate this balance. The tests were conducted in the 20-inch Mach 6 wind tunnel at NASA-Langley. The balance thermal effects were evaluated at freestream Reynolds numbers ranging from .5 to 7 x 10(exp 6) ft and angles of attack between -3.5 to 5 deg at Mach 6. The injection gases considered included cold air, hot air, and a mixture of 50 percent Argon and 50 percent Freon-12. The stagnation temperatures of the cold air, hot air, and Ar-Fr(12) reached 111, 214, and 283 F, respectively within the balance. A bakelite sleeve was inserted into the inner tube of the balance to minimize the thermal effects of these injection gases. Throughout the tests, the normal force, side force, yaw moment, roll moment, and pitching moment balance measurements were unaffected by the balance thermal effects of the injection gases and the wind tunnel flow. However, the axial force (AF) measurement was significantly affected by balance heating. The average zero shifts in the AF measurements were 1.9, 3.8, and 5.9 percent for cold air, hot air, and Ar-Fr(12) injection, respectively. The AF measurements decreased throughout these tests which lasted from 70 to 110 seconds. During the cold air injection tests, the AF measurements were accurate up to at least ten seconds after the model was injected into the wind tunnel test section. For the hot air and Ar-Fr(12) tests, the AF measurements were accurate up to at least five seconds after model injection.

Kniskern, Marc W.↗

Effectiveness of spoilers on the GA(W)-1 airfoil with a high performance Fowler flap

Two-dimensional wind-tunnel tests were conducted to determine effectiveness of spoilers applied to the GA(W)-1 airfoil. Tests of several spoiler configurations show adequate control effectiveness with flap nested. It is found that providing a vent path allowing lower surface air to escape to the upper surface as the spoiler opens alleviates control reversal and hysteresis tendencies. Spoiler cross-sectional shape variations generally have a modest influence on control characteristics. A series of comparative tests of vortex generators applied to the (GA-W)-1 airfoil show that triangular planform vortex generators are superior to square planform vortex generators of the same span.

Wentz, W. H., Jr.↗

Prepared comment on the cone transition Reynolds number data correlation study

A sharp, smooth, 10-deg-included-angle cone was tested on twenty-one major wind tunnels of the United States and Western Europe to obtain correlation data on the effect of acoustic disturbances in wind tunnel flow on boundary layer transition Reynolds number. The cone is planned to be flight tested in order to obtain a basis of reference for the wind tunnel data over a nominal range of Mach numbers from 0.4 to approximately 2.0. Wind tunnel data obtained over a Mach number range from 0.2 to 4.6 are broadly characterized according to wind tunnel test section geometry and, in turn, to the types of acoustic disturbances associated with the geometry.

Dougherty, N. S., Jr.↗

Hypersonic Boundary-Layer Stability Experiments on a Flared-Cone Model at Angle of Attack in a Quiet Wind Tunnel

An experimental investigation of the effects of angle of attack on hypersonic boundary-layer stability on a flared-cone model was conducted in the low-disturbance Mach-6 Nozzle-Test Chamber Facility at NASA Langley Research Center. This unique facility provided a 'quiet' flow test environment which is well suited for stability experiments because the low levels of freestream 'noise' minimize artificial stimulation of flow-disturbance growth. Surface pressure and temperature measurements documented the adverse-pressure gradient and transition-onset location. Hot-wire anemometry diagnostics were applied to identify the instability mechanisms which lead to transition. In addition, the mean flow over the flared-cone geometry was modeled by laminar Navier-Stokes computations. Results show that the boundary layer becomes more stable on the windward ray and less stable on the leeward ray relative to the zero-degree angle-of-attack case. The second-mode instability dominates the transition process at a zero-degree angle of attack, however, on the windward ray at an angle of attack this mode was completely stabilized. The less-dominant first-mode instability was slightly destabilized on the windward ray. Non-linear mechanisms such as saturation and harmonic generation are identified from the flow-disturbance bispectra.

Doggett, Glen P.↗

Scanning tunneling microscopy study of the antiferromagnetic topological insulator MnBi 2 Se 4

Topological insulators with intrinsic magnetic ordering such as MnBi 2 Se 4 have been predicted to host many exotic topological phenomena including dissipationless edge states and magnetoelectric effects. Here we use scanning tunneling microscopy to study the surface of MnBi 2 Se 4 epitaxial thin films. Large scale topographic images show steps between van der Waals layers and screw dislocations. While we find the Se-termination predominant on the surface, areas attributed to Bi-termination are found at the edges of small islands in as-grown films, or in larger areas upon removal of surface capping. Here, we compare these terminations through an analysis of step heights, atomic resolution images and tunneling spectroscopy. Tunneling spectra on the Se-termination reveals semiconducting behavior, with an apparent bandgap of >0.18eV that depends on the tip height. In contrast, tunneling spectra of the Bi-termination appears gapless, which could be an indication of dangling bond states on the surface. In both cases, a hexagonal 3.9Å lattice is observed that is consistent with the expected crystal structure.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Numerical Evaluation of Icing Effects on a Natural Laminar Flow Airfoil

As a part of CFD code validation efforts within the Icing Branch of NASA Glenn Research Center, computations were performed for natural laminar flow (NLF) airfoil, NLF-0414. with 6 and 22.5 minute ice accretions. Both 3-D ice castings and 2-D machine-generated ice shapes were used in wind tunnel tests to study the effects of natural ice is well as simulated ice. They were mounted in the test section of the Low Turbulence Pressure Tunnel (LTPT) at NASA Langley that the 2-dimensionality of the flow can be maintained. Aerodynamic properties predicted by computations were compared to data obtained through the experiment by the authors at the LTPT. Computations were performed only in 2-D and in the case of 3-D ice, the digitized ice shape obtained at one spanwise location was used. The comparisons were mainly concentrated on the lift characteristics over Reynolds numbers ranging from 3 to 10 million and Mach numbers ranging from 0.12 to 0.29. WIND code computations indicated that the predicted stall angles were in agreement with experiment within one or two degrees. The maximum lift values obtained by computations were in good agreement with those of the experiment for the 6 minute ice shapes and the minute 3-D ice, but were somewhat lower in the case of the 22.5 minute 2-D ice. In general, the Reynolds number variation did not cause much change in the lift values while the variation of Mach number showed more change in the lift. The Spalart-Allmaras (S-A) turbulence model was the best performing model for the airfoil with the 22.5 minute ice and the Shear Stress Turbulence (SST) turbulence model was the best for the airfoil with the 6 minute ice and also for the clean airfoil. The pressure distribution on the surface of the iced airfoil showed good agreement for the 6 minute ice. However, relatively poor agreement of the pressure distribution on the upper surface aft of the leading edge horn for the 22.5 minute ice suggests that improvements are needed in the grid or turbulence models.

Chung, James J.↗

An experimental investigation of dynamic ground effect

Sixty degree delta wing, F-106B, and XB-70 models with and without flap deflections were tested in static and dynamic ground effect in the 36 by 51 inch subsonic wind tunnel at the University of Kansas. Dynamic ground effect was measured with movable sting support. For flow visualization, a tufted wire grid was mounted on the movable sting behind the model. Tests results showed that the lift and drag increments in dynamic ground effect were always lower than the static values. Effect of the trailing-edge flap deflections on lift increments was slight. The fuselage reduced the lift increments at a given ground height. From flow visualization under static conditions, the vortex core was seen to enlarge as the ground approached.

Lee, Pai Hung↗

An experimental investigation of dynamic ground effect

A 60-degree delta wing, an F-106B, and an XB-70 model with and without flap deflections were tested in static and dynamic ground effect in the 36-by 51-inch subsonic wind tunnel at the University of Kansas. Dynamic ground effect was measured with movable sting support. For flow visualization, a tufted wire grid was mounted on the movable sting behind the model. Test results showed that lift and drag increments in dynamic ground effect were always lower than static values. Effect of the trailing edge flap deflections on lift increments was slight. The fuselage reduced the lift increments at a given ground height. From flow visualization under static conditions, the vortex core was seen to enlarge as the ground was approached.

Lee, Pai Hung↗

Experimental investigation of dynamic ground effect

A 60-degree delta wing, an F-106B, and an XB-70 model with and without flap deflections were tested in static and dynamic ground effect in the 36-by-51-inch subsonic wind tunnel at the University of Kansas. Dynamic ground effect was measured with movable sting support. For flow visualization, a tufted wire grid was mounted on the movable sting behind the model. Test results showed that lift and drag increments in dynamic ground effect were always lower than static values. Effect of the trailing edge flap deflections on lift increments was slight. The fuselage reduced the lift increments at a given ground height. From flow visualization under static conditions, the vortex core was seen to enlarge as the ground was approached.

Lee, Pai-Hung↗

The Langley 14- by 22-Foot Subsonic Tunnel: Description, Flow Characteristics, and Guide for Users

The Langley 14- by 22-foot Subsonic Tunnel is a closed circuit, single-return atmospheric wind tunnel with a test section that can be operated in a variety of configurations (closed, slotted, partially open, and open). The closed test section configuration is 14.5 ft high by 21.75 ft wide and 50 ft long with a maximum speed of about 338 ft/sec. The open test section configuration has a maximum speed of about 270 ft/sec, and is formed by raising the ceiling and walls, to form a floor-only configuration. The tunnel may be configured with a moving-belt ground plane and a floor boundary-layer removal system at the entrance to the test section for ground effect testing. In addition, the tunnel had a two-component laser velocimeter, a frequency modulated (FM) tape system for dynamic data acquisition, flow visualization equipment, and acoustic testing capabilities. Users of the 14- by 22-foot Subsonic Tunnel are provided with information required for planning of experimental investigations including test hardware and model support systems.

Gentry, Garl L., Jr.↗