Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TIME SIGNAL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

Prototypes of self-powered radiation detectors employing intrinsic high-energy current

Purpose: The authors experimentally investigate the effect of direct energy conversion of x-rays via selfpowered Auger- and photocurrent, potentially suitable to practical radiation detection and dosimetry in medical applications. Experimental results are compared to computational predictions. The detector the authors consider is a thin-film multilayer device, composed of alternating disparate electrically conductive and insulating layers. This paper focuses on the experiments while a companion paper introduces the fundamental concepts of high-energy current (HEC) detectors. Methods: The energy of ionizing radiation is directly converted to detector signal via electric current induced by high-energy secondary electrons generated in the detector material by the incident primary radiation. The HEC electrons also ionize the dielectric and the resultant charge carriers are selfcollected due to the contact potential of the disparate electrodes. Thus, an electric current is induced in the conductors in two different ways without the need for externally applied bias voltage or amplification. Thus, generated signal in turn is digitized by a data acquisition system. To determine the fundamental properties of the HEC detector and to demonstrate its feasibility for medical applications, the authors used a planar geometry composed of multilayer microstructures. Various detectors with up to seven conducting layers with different combinations of materials (250 μm Al, 35 μm Cu, 100 μm Pb) and air gaps (100 μm) were exposed to nearly plane-parallel 60–120 kVp x-ray beams. For the experimental design and verification, the authors performed coupled electron–photon radiation transport computations. The detector signal was measured using a commercial data acquisition system with 24 bits dynamic range, 0.4 fC sensitivity, and 0.9 ms sampling time. Results: Measured signals for the prototype detector varied depending on the number of layers, material type, and incident photon energy, and it was in the range of 30–150 nA/cm{sup 2} for unit air kerma (1 Gy), which is viable for practical applications. The experiments had an excellent agreement with the computations. Within the examined range of 60–120 kVp, the energy dependence of the HEC (normalized to the x-ray tube output) was relatively small. Conclusions: Based on the experimental results for 100 ms sampling time, it would be possible to measure the time dependence of x-ray beams for x-ray tube current of 0.1 mA or higher. Significant advantages of the HEC device are that generation of its signal does not require external power supply, it can be made in any size and shape, including flexible curvilinear forms, and it is inexpensive. It remains to be determined, which of the potential applications in medical dosimetry (both in vivo and external), or radiation protection would benefit from such selfpowered detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dynamic programming based time-delay estimation technique for analysis of time-varying time-delay

A new time-delay estimation (TDE) technique based on dynamic programming is developed to measure the time-varying time-delay between two signals. The dynamic programming based TDE technique provides a frequency response five to ten times better than previously known TDE techniques, namely, those based on time-lag cross-correlation or wavelet analysis. Effects of frequency spectrum, signal-to-noise ratio, and amplitude of time-delay on response of the TDE technique (represented as transfer function) are studied using simulated data signals. The transfer function for the technique decreases with increase in noise in signal; however it is independent of signal spectrum shape. The dynamic programming based TDE technique is applied to the beam emission spectroscopy diagnostic data to measure poloidal velocity fluctuations, which led to the observation of theoretically predicted zonal flows in high-temperature tokamak plasmas.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Laser-Induced Fluorescence of Xe I and Xe II in Ambipolar Plasma Flow

Laser-induced fluorescence diagnostic technique is applied here to probe xenon neutrals and single-charged ions in an ambipolar plasma source. A single tunable diode laser is employed for pumping both following transitions: 6s 2 [1/2] 1 0 -6p 2 [3/2] 1 0 (centered at 834.68 nm; air) and 5d[4] 7/2 -6p[3] 5/2 (centered at 834.72 nm; air), for Xe I and Xe II detection, respectively. The corresponding decay states are 6s[3/2] 1 0 and 6s[2] 3/2 leading to fluorescence signal at 473.415 and 541.915 nm, respectively. A detailed description of the experimental setup along with time-averaged fluorescence signals are presented, demonstrating the possible application of the above adjacent pumping wavelengths in xenon ambipolar plasmas for probing both ions and neutrals under various operating conditions. Furthermore a comprehensible discussion to what extent the registered laser-induced fluorescence signals mirror velocity distribution functions is realized, following hyperfine splitting and isotopic shift analysis.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Particle size and velocity measurement by laser anemometry

The use of a forward scattering Laser Anemometer system for the measurement of particle diameters larger than the fringe spacing is investigated. A systematic calibration experiment demonstrates a direct relationship between signal amplitude and particle diameter for transparent particles between 30 microns and 240 microns in diameter. A light scattering analysis confirms these measurements and indicates how the range of particles which can be measured using the peak (mean) signal depends on the optical arrangement and particle properties. On the basis of this work a real time Laser Anemometer signal processor is modified so that the peak of the mean of each signal can be measured. A method of correcting data for the effect of particles which do not go through the center of the measurement volume is derived. Good agreement is found between particle size distributions measured in sprays by using the Laser Anemometer and size distributions measured by collecting the particles on a slide and using an image analysis computer.

Yule, A. J.↗

Microwave delay characteristics of Cassegrainian antennas

A technique is presented in which the time an RF signal is delayed in propagating through a Cassegrain antenna is determined. The technique utilizes the group delay time and the envelope delay time as found from the antenna transfer function. The calculations show that a focused antenna is basically a nondispersive device whose delay time may be found from an optics formula. Small subreflector displacements result in significant delay changes requiring calibrations for many applications.

Cha, A. G.↗

Development of a Rayleigh scattering system for temperature measurements in combustor flows

A dual line laser induced Rayleigh scattering system has been developed to be used in high temperature gas flows such as in combustors, and preliminary tests have been performed in a hot air jet. The qualification measurements included the collection and analysis of Rayleigh signal for time-resolved gas temperature over the two lines of a copper-vapor laser. The dual line signal collection technique is a feature to be used in detecting and discriminating the surface scattered laser light in the Rayleigh signal. Optical fibers are used to transmit the laser beam to the optical probe bench and to carry the collected signal from the bench to the housing of the signal sensors. Incident laser intensity at the probe volume is measured for both lines at each pulse of the laser. This information is used to normalize the signal. Good agreement has been obtained between the two line Rayleigh scattering and thermocouple results in the particle free co-flowing air jet.

Otugen, M. V.↗

Compact ion chamber based neutron detector

A directional neutron detector has an ion chamber formed in a dielectric material; a signal electrode and a ground electrode formed in the ion chamber; a neutron absorbing material filling the ion chamber; readout circuitry which is electrically coupled to the signal and ground electrodes; and a signal processor electrically coupled to the readout circuitry. The ion chamber has a pair of substantially planar electrode surfaces. The chamber pressure of the neutron absorbing material is selected such that the reaction particle ion trail length for neutrons absorbed by the neutron absorbing material is equal to or less than the distance between the electrode surfaces. The signal processor is adapted to determine a path angle for each absorbed neutron based on the rise time of the corresponding pulse in a time-varying detector signal.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improved time-frequency analysis of ASDEX Upgrade reflectometry data using the reassigned spectrogram technique

The spectrogram is one of the best-known time-frequency distributions suitable to analyze signals whose energy varies both in time and frequency. In reflectometry, it has been used to obtain the frequency content of FM-CW signals for density profile inversion and also to study plasma density fluctuations from swept and fixed frequency data. Being implemented via the short-time Fourier transform, the spectrogram is limited in resolution, and for that reason several methods have been developed to overcome this problem. Among those, we focus on the reassigned spectrogram technique that is both easily automated and computationally efficient requiring only the calculation of two additional spectrograms. In each time-frequency window, the technique reallocates the spectrogram coordinates to the region that most contributes to the signal energy. The application to ASDEX Upgrade reflectometry data results in better energy concentration and improved localization of the spectral content of the reflected signals. When combined with the automatic (data driven) window length spectrogram, this technique provides improved profile accuracy, in particular, in regions where frequency content varies most rapidly such as the edge pedestal shoulder.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Time-Frequency Analysis of the Dispersion of Lamb Modes

Accurate knowledge of the velocity dispersion of Lamb modes is important for ultrasonic nondestructive evaluation methods used in detecting and locating flaws in thin plates and in determining their elastic stiffness coefficients. Lamb mode dispersion is also important in the acoustic emission technique for accurately triangulating the location of emissions in thin plates. In this research, the ability to characterize Lamb mode dispersion through a time-frequency analysis (the pseudo-Wigner-Ville distribution) was demonstrated. A major advantage of time-frequency methods is the ability to analyze acoustic signals containing multiple propagation modes, which overlap and superimpose in the time domain signal. By combining time-frequency analysis with a broadband acoustic excitation source, the dispersion of multiple Lamb modes over a wide frequency range can be determined from as little as a single measurement. In addition, the technique provides a direct measurement of the group velocity dispersion. The technique was first demonstrated in the analysis of a simulated waveform in an aluminum plate in which the Lamb mode dispersion was well known. Portions of the dispersion curves of the AO, A I , So, and S2 Lamb modes were obtained from this one waveform. The technique was also applied for the analysis of experimental waveforms from a unidirectional graphite/epoxy composite plate. Measurements were made both along and perpendicular to the fiber direction. In this case, the signals contained only the lowest order symmetric and antisymmetric modes. A least squares fit of the results from several source to detector distances was used. Theoretical dispersion curves were calculated and are shown to be in good agreement with experimental results.

Prosser, W. H.↗

Time-Frequency Analysis of the Dispersion of Lamb Modes

Accurate knowledge of the velocity dispersion of Lamb modes is important for ultrasonic nondestructive evaluation methods used in detecting and locating flaws in thin plates and in determining their elastic stiffness coefficients. Lamb mode dispersion is also important in the acoustic emission technique for accurately triangulating the location of emissions in thin plates. In this research, the ability to characterize Lamb mode dispersion through a time-frequency analysis (the pseudo Wigner-Ville distribution) was demonstrated. A major advantage of time-frequency methods is the ability to analyze acoustic signals containing multiple propagation modes, which overlap and superimpose in the time domain signal. By combining time-frequency analysis with a broadband acoustic excitation source, the dispersion of multiple Lamb modes over a wide frequency range can be determined from as little as a single measurement. In addition, the technique provides a direct measurement of the group velocity dispersion. The technique was first demonstrated in the analysis of a simulated waveform in an aluminum plate in which the Lamb mode dispersion was well known. Portions of the dispersion curves of the A(sub 0), A(sub 1), S(sub 0), and S(sub 2)Lamb modes were obtained from this one waveform. The technique was also applied for the analysis of experimental waveforms from a unidirectional graphite/epoxy composite plate. Measurements were made both along, and perpendicular to the fiber direction. In this case, the signals contained only the lowest order symmetric and antisymmetric modes. A least squares fit of the results from several source to detector distances was used. Theoretical dispersion curves were calculated and are shown to be in good agreement with experimental results.

Prosser, W. H.↗

Cardiac Monitor

Under contract to Johnson Space Center, the University of Minnesota developed the concept of impedance cardiography as an alternative to thermodilution to access astronaut heart function in flight. NASA then contracted Space Labs, Inc. to construct miniature space units based on this technology. Several companies then launched their own impedance cardiography, including Renaissance Technologies, which manufactures the IQ System. The IQ System is 5 to 17 times cheaper than thermodilution, and features the signal processing technology called TFD (Time Frequency Distribution). TFD provides three- dimensional distribution of the blood circulation force signals, allowing visualization of changes in power, frequency and time.

Source record↗

XFEL SASE pulses can enhance time-dependent observables

Abstract X-ray free electron lasers (XFELs) have emerged as powerful sources of short and intense x-ray pulses. We propose a simple and robust procedure which takes advantage of the inherent stochasticity of self-amplified stimulated emission (SASE) pulses to enhance the time-resolution and signal strength of the recorded data. Notably, the proposed method is able to enhance the average signal without knowledge of the signal strength of individual shots. Simple metrics for the probe pulses are introduced, such as an effective pulse duration applicable to SASE pulses characterised in the time domain using e.g. an X-band transverse cavity. The approach is evaluated using simulated and real pulse data in the context of ultrafast electron dynamics in a molecule. Utilising H 2 as a model system, we demonstrate the efficacy of the method theoretically, successfully enhancing the predicted nonresonant ultrafast x-ray scattering signal associated with electron dynamics. The method presented is broadly applicable and offers a general strategy for enhancing time-dependent observables at XFELs.

data analysis↗

Two-Dimensional Acousto-Optical Spectrum Analyzer

State-of-the-art two-dimensional acousto-optical spectrum analyzer processes input radio-frequency signal in real time into components in any number of spectral channels up to about 10(Sup5). Input radio-frequency signal to be analyzed launched via transducer into acousto-optical device along x axis. Acousto-optical device becomes Bragg cell. Pulsed plane waves of light from laser aimed at Bragg cell, which spatially modulates phases of plane waves and diffracts waves according to pattern of acoustic signal.

Ansari, Homayoon↗

Synchronous demodulator

A synchronous demodulator includes a switch which is operated in synchronism with an incoming periodic signal and both divides and applies that signal to two signal channels. The two channels each include a network for computing and holding, for a predetermined length of time, the average signal value on that channel and applies those valves, in the form of two other signals, to the inputs of a differential amplifier. The networks may be R-C networks. The output of the differential amplifier may or may not form the output of the synchronous detector and may or may not be filtered. The output will not include a periodic signal due to the presence of a dc offset. Additionally, the output will not contain any substantial ripple due to periodic components in the input signal. In a somewhat more complex version, containing twice the structural components of the above synchronous demodulator with a more complex switching mechanism, essentially all ripple due to periodic components in the input signal are eliminated.

Sutton, John F.↗

Coherently combining antennas

An apparatus includes antenna elements configured to receive a signal including pseudo-random code, and electronics configured to use the pseudo-random code to determine time delays of signals incident upon the antenna elements and to compensate the signals to coherently combine the antenna elements.

Dybdal, Robert B.↗

Integrated optical signal processing with magnetostatic waves

Magneto-optical devices based on Bragg diffraction of light by magnetostatic waves (MSW's) offer the potential of large time-bandwidth optical signal processing at microwave frequencies of 1 to 20 GHz and higher. A thin-film integrated-optical configuration, with the interacting MSW and guided-optical wave both propagating in a common ferrite layer, is necessary to avoid shape-factor demagnetization effects. The underlying theory of the MSW-optical interaction is outlined, including the development of expressions for optical diffraction efficiency as a function of MSW power and other relevant parameters. Bradd diffraction of guided-optical waves by transversely-propagating magnetostatic waves and collinear TE/TM mode conversion included by MSW's have been demonstrated in yttrium iron garnet (YIG) thin films. Diffraction levels as large as 4% (7 mm interaction length) and a modulation dynamic range of approx 30 dB have been observed. Advantages of these MSW-based devices over the analogous acousto-optical devices include: much greater operating frequencies, tunability of the MSW dispersion relation by varying either the RF frequency or the applied bias magnetic field, simple broad-band MSW transducer structures (e.g., a single stripline), and the potential for very high diffraction efficiencies.

Fisher, A. D.↗

Telecommand/Telemetry Ranging for Deep-Space Applications

Conventional two-way pseudonoise (PN) ranging relies on measuring the time delay between a PN signal transmitted to the spacecraft, and a corresponding synchronized PN signal transmitted from the spacecraft and received on the ground. Recently, we introduced a two-way ranging method ([1], [2], [3]) which eliminates the need for the downlink PN ranging signal. In this telemetry ranging scheme, the requisite timing measurements are obtained from a databearing downlink telemetry signal. In the present paper, we extend the telemetry ranging concept by also eliminating the uplink PN signal, which is replaced by a data-bearing telecommand signal. We describe the architecture and concept of such a system, and describe the fundamental limitations of tracking the timing of such uplink telecommand signals when tracking loops or demod-remod correlation techniques are employed. An end-to-end performance analysis shows that in typical scenarios, ranging performance comparable to conventional PN ranging is possible.

Hamkins, Jon↗