Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Spectrometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

Visible (400- to 700-nm) chirped-grating-coupled waveguide spectrometer

An integrable on-chip spectrometer, based on a transversely-chirped-grating waveguide-coupler for the 400- to 700-nm visible spectral range is demonstrated. For a fixed angle of incidence, the coupling wavelength is dependent on the local grating period and the waveguide structure. The transversely-chirped-input grating is fabricated on a SiO 2 -Si 3 N 4 -SiO 2 waveguide atop a Si substrate by interferometric lithography in two sections on a single silicon substrate. A uniform period grating, separated from the input coupler by a propagation region, is provided for out-coupling to a 2048 element CMOS detector array. The incident light with wavelength spanning 400- to 700-nm is coupled into waveguide at 33.5° through the chirped grating coupler. A resolution of ∼ 1.2 nm is demonstrated without any signal processing reconstruction.

Wang, Xuemei↗

Fast data-driven spectrometer with direct measurement of time and frequency for multiple single photons

We present a single-photon-sensitive spectrometer based on a linear array of 512 single-photon avalanche diode detectors with 0.04 nm spectral and 40 ps temporal resolutions. We employ a fast data-driven operation that allows direct measurement of time and frequency for simultaneous single photons, time- and frequency-stamping each single-photon detection. Our results combine excellent temporal and spectral resolution. This work opens numerous applications in quantum photonics, especially when both spectral and temporal properties of single photons can be exploited.

79 ASTRONOMY AND ASTROPHYSICS↗

Pump–probe spectrometer for measuring x-ray induced strain

A hard x-ray pump–probe spectrometer using a multi-crystal Bragg reflector is demonstrated at a third generation synchrotron source. This device derives both broadband pump and monochromatic probe pulses directly from a single intense, broadband x-ray pulse centered at 8.767 keV. In conclusion, we present a proof-of-concept experiment which directly measures x-ray induced crystalline lattice strain.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sensitivity Limitation of an Optical Heterodyne Spectrometer

We show an optical heterodyne spectrometer with picometer resolution and high sensitivity. Moreover, we report the quantum limit of detecting multi-mode light using heterodyne detection, and compare it to a typical down conversion source output.

Chapman, Joseph↗

High-energy inelastic neutron scattering data taken at the SEQUOIA spectrometer.

INS measurements were performed using the Fine Resolution Chopper Spectrometer SEQUOIA at the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory. A powder sample of SrCoGe2O6 was loaded in an aluminum can for the measurements and a CCR was used to cool the sample down to 6 K. Data were collected using fixed incident neutron energies of 100 and 30 meV.

MATERIALS SCIENCE↗

Low energy inelastic neutron scattering (INS) data of SrCoGe2O6 taken at CNCS chopper spectrometer.

INS measurements were performed using the Cold Neutron Chopper Spectrometer CNCS at the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory. A powder sample of SrCoGe2O6 was loaded in an aluminum can for the measurements and a standard orange cryostat was used to cover the temperature region from 1.7 K to 100 K. Data were collected using fixed incident neutron energy of 5.0 meV.

MATERIALS SCIENCE↗

INS spectra of NH3 and ND3 obtained at SEQUOIA spectrometer

These INS data were measured at SEQUOIA spectrometer. The samples used were NH3 and ND3, and empty container (background runs). The measurements were done with incident neutron energies Ei=30, 50, 85, 280 and 700 meV at T=5K, 50K, 100K, 180K, 200K for NH3 sample, and with Ei=30, 70, 200, 500 meV at T=5K, 50K, 100K, 180K, 200K and 230K for ND3.

excitations↗

Measurement of differential cross sections for single diffractive dissociation in s = 8 TeV p p collisions using the ATLAS ALFA spectrometer

A dedicated sample of Large Hadron Collider proton-proton collision data at centre-of-mass energy s√=8 TeV is used to study inclusive single diffractive dissociation, pp→Xp. The intact final-state proton is reconstructed in the ATLAS ALFA forward spectrometer, while charged particles from the dissociated system X are measured in the central detector components. Cross sections are measured differentially as functions of the proton fractional energy loss ξ, the squared four-momentum transfer t, and Δη, a variable that characterises the rapidity gap separating the proton and the system X. The data are consistent with an exponential t dependence, dσ/dt∝eBt with slope parameter B=7.65±0.34 GeV−2. Interpreted in the framework of Regge phenomenology, the ξ dependence leads to a pomeron intercept of α(0)=1.07±0.09.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

MPACT LSDS Progress Report: LANL and LANL-Funded Activities in Support of Spent Fuel Measurements Using a Lead Slowing Down Spectrometer in FY 2012

During FY 2012, Lead Slowing Down Spectrometer (LSDS) measurement campaigns took place at the Los Alamos Neutron Science Center, and the Rensselaer Polytechnic Institute. At Los Alamos, we measured the response of a thorium fission chamber to a 25 gram plutonium sample, and evaluated the performance of a 4 He-filled proportional counter. At RPI, the effort lead by Professor Danon, performed an assay of fuel pins, and used a fission chamber with plutonium to evaluate the impact of room return.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The Effectiveness of the Compton Radiography Snout Electron Deflection Yoke and its Application as an Electron Spectrometer

The Compton Radiography Snout (CRS) is a prototype of a diagnostic called the High Energy X Ray Imager (HEXRI) that will be used to record radiographs of imploding fuel cells on NIF. With these radiographs, it is possible to characterize the density and symmetry of the imploding fuel capsule. When the advanced radiography capability is used to generate the high energy x‐rays used to backlight the radiographs, hot electrons are also produced. In order to record a clear radiograph, these electrons are deflected away from the imaging plane of the CRS using a permanent magnetic yoke. In an effort to increase the number of parameters that can be used during the scaling of the CRS for NIF, an investigation is underway to add an electron spectrometer capability to the CRS to measure the electron spectrum produced during the ARC backlighting.

42 ENGINEERING↗

Associated Particle Tagging (APT) in Magnetic Spectrometers

Summary In Brief The Associated Particle Tagging (APT) project, a collaboration of Pacific Northwest National Laboratory (PNNL), Idaho National Laboratory (INL) and the Idaho State University (ISU)/Idaho Accelerator Center (IAC), has completed an exploratory study to assess the role of magnetic spectrometers as the linchpin technology in next-generation tagged-neutron and tagged-photon active interrogation (AI).

Jordan, David V.↗

Layout and results from the initial operation of the high-resolution x-ray imaging crystal spectrometer on the Large Helical Device

First results of ion and electron temperature profile measurements from the x-ray imaging crystal spectrometer (XICS) diagnostic on the Large Helical Device (LHD) are presented. This diagnostic system has been operational since the beginning of the 2011 LHD experimental campaign and is the first application of the XICS diagnostic technique to helical plasma geometry. The XICS diagnostic provides measurements of ion and electron temperature profiles in LHD with a spatial resolution of 2cm and a time resolution of ≥ 10ms. Ion temperature profiles from the XICS diagnostic are possible under conditions where charge exchange recombination spectroscopy (CXRS) is not possible (high density) or is perturbative to the plasma (low density or radio frequency heated plasmas). Measurements are made by using a spherically bent crystal to provide a spectrally resolved 1D image of the plasma from line integrated emission of helium-like Ar 16+ . The final hardware design and configuration are detailed along with the calibration procedures. Line-integrated ion and electron temperature measurements are presented, and the measurement accuracy is discussed. Finally central temperature measurements from the XICS system are compared to measurements from the Thomson scattering and CXRS systems, showing excellent agreement.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Mobile Ice Nucleus Spectrometer

This first year report presents results from a computational fluid dynamics (CFD) study to assess the flow and temperature profiles within the mobile ice nucleus spectrometer.

Kulkarni, Gourihar R.↗

Validation and Verification of the Correct Operation of the Spectro RS23 UV-VIS Spectrometer used in ANC122 and NF-ANC122

In September of 2011, the old qualified Bausch and Laum Spec 100 UV-Vis instrument used in the ANC122 and NF-ANC122 procedures failed its monthly calibration check. Attempts to get the system to pass by cleaning flow cells, replacing the light bulb and realigning the light path failed to get sustained reproducible results from the system. In October the decision to take it out of service was made as the system was 40+ years in age. To replace the system, a previously purchased Labomed Inc.’s spectrometer (model Spectro 23RS; Serial #: 23RS-004253) was retrieved from storage. This report shows that the Labomed Inc. system is performing as required and meeting all QC requirements listed in ANC122 and NF-ANC122. Upon submitting this report to records, the system will be considered qualified to report results to customers of C-AAC.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Toward Simultaneous Single-Particle Chemical and Optical Characterization: Development of a Multi-Angle Optical Scattering Module for the Aerosol Time-of-Flight Mass Spectrometer (Final Report)

This project was an initial effort to investigate the feasibility of an instrument combining real-time atmospheric particle composition measurements using an ATOFMS (Atmospheric Time-Of-Flight Mass Spectrometer) such as those performed by Prather’s group at the University of California, San Diego (UCSD) with multi-wavelength scattering measurements of the type investigated by Sorensen et al., of Kansas State University (KSU). In this Phase I effort we proposed to investigate near-angle scattering and the possibility of integration of a multi-wavelength scattering instrument into the UCSD ATOFMS. After an initial optical design and calculations, we discovered issues with the theory of measurement and with mechanical integration. Evidence emerged that the method of multi-wavelength scattering is only efficacious for spherical particles, while most atmospheric particles are non-spherical fractal aggregates. We also determined that the integration of the detector into existing ATOFMS instruments would be severely limited by volume constraints, and additional volume would require prohibitive additional pumping compared with the existing ATOFMS systems. Based on this evidence, we decided not to pursue a Phase II effort.

47 OTHER INSTRUMENTATION↗

Photoacoustic Soot Spectrometer (PASS) Instrument Handbook

The photoacoustic soot spectrometer (PASS) measures light absorption by aerosol particles. As the particles pass through a laser beam, the absorbed energy heats the particles and in turn the surrounding air, which sets off a pressure wave that can be detected by a microphone. The PASS instruments deployed by ARM can also simultaneously measure the scattered laser light at three wavelengths and therefore provide a direct measure of the single-scattering albedo. The Operator Manual for the PASS-3100 is included here with the permission of Droplet Measurement Technologies, the instrument’s manufacturer.

Dubey, M↗