Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Spatial resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

Invited article: X-ray phase contrast imaging in inertial confinement fusion and high energy density research

X-ray phase contrast imaging (XPCI) provides enhanced image contrast beyond absorption-based x-ray imaging alone due to refraction and diffraction from gradients in the object material density. It is sensitive to small variations in density, such as internal voids, cracks, grains, defects, and material flow, as well as to stronger density variations such as from a shock wave. Beyond its initial use in biology and materials science, XPCI is now routinely used in inertial confinement fusion (ICF) and high energy density (HED) research, first to characterize ICF capsules and targets, and later applied in dynamic experiments, where coherent x-ray sources, ultrafast x-ray pulses, and high temporal and spatial resolution are required. In this Review article, XPCI image formation theory is presented, its diverse use in ICF and HED research is discussed, the unique requirements for ultrafast XPCI imaging are given, as well as current challenges and issues in its use.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design and implementation of a prototype infrared video bolometer (IRVB) in MAST Upgrade

A prototype infrared video bolometer (IRVB) was successfully deployed in the Mega Ampere Spherical Tokamak Upgrade (MAST Upgrade or MAST-U), the first deployment of such a diagnostic in a spherical tokamak. The IRVB was designed to study the radiation around the lower x-point, another first in tokamaks, and has the potential to estimate emissivity profiles with spatial resolution beyond what is achievable with resistive bolometry. The system was fully characterized prior to installation on MAST-U, and the results are summarized here. After installation, it was verified that the actual measurement geometry in the tokamak qualitatively matches the design; this is a particularly difficult process for bolometers and was done using specific features of the plasma itself. The installed IRVB measurements are consistent both with observations from other diagnostics, including magnetic reconstruction, visible light cameras, and resistive bolometry, as well as with the IRVB-designed view. Early results show that with conventional divertor geometry and only intrinsic impurities (for example, C and He), the progression of radiative detachment follows a similar path to that observed for large aspect ratio tokamaks: The peak of the radiation moves along the separatrix from the targets to the x-point and high-field side midplane with a toroidally symmetric structure that can eventually lead to strong effects on the core plasma inside the separatrix.

47 OTHER INSTRUMENTATION↗

Analysis techniques for blob properties from gas puff imaging data

Filamentary structures, also known as blobs, are a prominent feature of turbulence and transport at the edge of magnetically confined plasmas. They cause cross-field particle and energy transport and are, therefore, of interest in tokamak physics and, more generally, nuclear fusion research. Several experimental techniques have been developed to study their properties. Among these, measurements are routinely performed with stationary probes, passive imaging, and, in more recent years, Gas Puff Imaging (GPI). In this work, we present different analysis techniques developed and used on 2D data from the suite of GPI diagnostics in the Tokamak à Configuration Variable, featuring different temporal and spatial resolutions. Although specifically developed to be used on GPI data, these techniques can be employed to analyze 2D turbulence data presenting intermittent, coherent structures. We focus on size, velocity, and appearance frequency evaluation with, among other methods, conditional averaging sampling, individual structure tracking, and a recently developed machine learning algorithm. We describe in detail the implementation of these techniques, compare them against each other, and comment on the scenarios to which these techniques are best applied and on the requirements that the data must fulfill in order to yield meaningful results.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

X-ray self-emission imaging with spherically bent Bragg crystals on the Z-machine

Here, an x-ray imaging scheme using spherically bent crystals was implemented on the Z-machine to image x rays emitted by the hot, dense plasma generated by a Magnetized Liner Inertial Fusion (MagLIF) target. This diagnostic relies on a spherically bent crystal to capture x-ray emission over a narrow spectral range (<15 eV), which is established by a limiting aperture placed on the Rowland circle. The spherical crystal optic provides the necessary high-throughput and large field-of-view required to produce a bright image over the entire, one-cm length of the emitting column of a plasma. The average spatial resolution was measured and determined to be 18 µm for the highest resolution configuration. With this resolution, the radial size of the stagnation column can be accurately determined and radial structures, such as bifurcations in the column, are clearly resolved. The success of the spherical-crystal imager has motivated the implementation of a new, two-crystal configuration for identifying sources of spectral line emission using a differential imaging technique.

47 OTHER INSTRUMENTATION↗

Synchrotron radiography of Richtmyer–Meshkov instability driven by exploding wire arrays

We present a new technique for the investigation of shock-driven hydrodynamic phenomena in gases, liquids, and solids in arbitrary geometries. The technique consists of a pulsed power-driven resistive wire array explosion in combination with multi-MHz synchrotron radiography. Compared to commonly used techniques, it offers multiple advantages: (1) the shockwave geometry can be shaped to the requirements of the experiment, (2) the pressure (P > 300 MPa) generated by the exploding wires enables the use of liquid and solid hydrodynamic targets with well-characterized initial conditions (ICs), (3) the multi-MHz radiography enables data acquisition to occur within a single experiment, eliminating uncertainties regarding repeatability of the ICs and subsequent dynamics, and (4) the radiographic measurements enable estimation of compression ratios from the x-ray attenuation. In addition, the use of a synchrotron x-ray source allows the hydrodynamic samples to be volumetrically characterized at a high spatial resolution with synchrotron-based microtomography. This experimental technique is demonstrated by performing a planar Richtmyer–Meshkov instability (RMI) experiment on an aerogel–water interface characterized by Atwood number A0∼−0.8 and Mach number M∼1.5. The qualitative and quantitative features of the experiment are discussed, including the energy deposition into the exploding wires, shockwave generation, compression of the interface, startup phase of the instability, and asymptotic growth consistent with Richtmyer's impulsive theory. Additional effects unique to liquids and solids—such as cavitation bubbles caused by rarefaction flows or initial jetting due to small perturbations—are observed. It is also demonstrated that the technique is not shape dependent by driving a cylindrically convergent RMI experiment.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Evaluation protocol for revealing magnonic contrast in TR-STXM measurements

We present a statistically motivated method to extract magnonic contrast from time-resolved scanning transmission x-ray microscopy (TR-STXM) measurements. TR-STXM is an element-specific method for resolving spin-dynamics in space and time. It offers nanometer spatial resolution and picosecond temporal resolution. The presented method makes it possible to obtain phase and amplitude profiles of spin-waves from STXM measurements. Furthermore, it allows for a rigorous transformation to reciprocal magnon k⃗-space, revealing k⃗-dependent magnon properties such as the magnon dispersion in three dimensions and for all directions of the magnetic anisotropy. We demonstrate our method using X-band ferromagnetic resonance on a micrometer-sized permalloy assembly.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Contrast optimization of Fresnel zone plate imaging

Fresnel zone plates (FZPs) are circular diffractive elements that operate as a lens for x-rays. They have gained interest in the field of laser-plasma physics due to their ability to achieve higher spatial resolution than pinholes. Their design and implementation are complicated by the fact that a significant amount of the x-rays passing through the FZP will not diffract (zeroth order) and present a background to the measurement. This background can be large and inhomogeneous depending on the geometric setup of the experiment. Furthermore, we present calculations of the diffracted (first order) and un-diffracted (zeroth order) flux profiles, which makes it possible to optimize the contrast between the first order imaging rays and the zeroth order background. Calculations for the implementation of a central block in the FZP, designed to block the zeroth from the entire field of view, are also presented.

47 OTHER INSTRUMENTATION↗

Direct imaging of shock wave splitting in diamond at Mbar pressure

Understanding the behavior of matter at extreme pressures of the order of a megabar (Mbar) is essential to gain insight into various physical phenomena at macroscales—the formation of planets, young stars, and the cores of super-Earths, and at microscales—damage to ceramic materials and high-pressure plastic transformation and phase transitions in solids. Under dynamic compression of solids up to Mbar pressures, even a solid with high strength exhibits plastic properties, causing the induced shock wave to split in two: an elastic precursor and a plastic shock wave. This phenomenon is described by theoretical models based on indirect measurements of material response. The advent of x-ray free-electron lasers (XFELs) has made it possible to use their ultrashort pulses for direct observations of the propagation of shock waves in solid materials by the method of phase-contrast radiography. However, there is still a lack of comprehensive data for verification of theoretical models of different solids. Here, we present the results of an experiment in which the evolution of the coupled elastic–plastic wave structure in diamond was directly observed and studied with submicrometer spatial resolution, using the unique capabilities of the x-ray free-electron laser (XFEL). The direct measurements allowed, for the first time, the fitting and validation of the 2D failure model for diamond in the range of several Mbar. Our experimental approach opens new possibilities for the direct verification and construction of equations of state of matter in the ultra-high-stress range, which are relevant to solving a variety of problems in high-energy-density physics.

36 MATERIALS SCIENCE↗

Absolute electron density fluctuation reconstruction for two-dimensional hydrogen beam emission spectroscopy

Scrape-off layer (SOL) and edge plasma turbulence significantly contribute to the radial particle and heat transport, lowering the plasma confinement and increasing the heat load on the plasma facing components. SOL turbulence is predominantly intermittent, which manifests in the occurrence of isolated density filaments or blobs. Filaments propagate radially outward toward plasma facing components, limiting their lifetime by erosion and sputtering. To characterize this phenomenon in detail, few diagnostic techniques are available. Beam emission spectroscopy is a diagnostic capable of measuring plasma turbulence in both SOL and edge plasmas. Due to the finite lifetime of the excitation states during the beam–plasma interaction and the misalignment between the optics and the magnetic field, spatial smearing is introduced in the measurement. In this paper, a novel method is introduced to overcome this hindering effect by inverting the fluctuation response matrix on an optimally smoothed signal. We show that this method is fast and provides significantly more accurate absolute density fluctuation reconstruction than the direct inversion technique. Here, the presented method is usable for all types of beam emission diagnostics where the spatial resolution is higher than the combined smearing of the atomic physics and the observation.

47 OTHER INSTRUMENTATION↗

High-magnification Faraday rotation imaging and analysis of X-pinch implosion dynamics

An X-pinch load driven by an intense current pulse (>100 kA in ~100 ns) can result in the formation of a small radius, runaway compressional micro-pinch. A micro-pinch is characterized by a hot (>1 keV), current-driven (>100 kA), high-density plasma column (near solid density) with a small neck diameter (1–10 µm), a short axial extent (<1 mm), and a short duration (≲1 ns). With material pressures often well into the multi-Mbar regime, a micro-pinch plasma often radiates an intense, sub-ns burst of sub-keV to multi-keV x rays. A low-density coronal plasma immediately surrounding the dense plasma neck could potentially shunt current away from the neck and thus reduce the magnetic drive pressure applied to the neck. Here, to study the current distribution in the coronal plasma, a Faraday rotation imaging diagnostic (1064 nm) capable of producing simultaneous high-magnification polarimetric and interferometric images has been developed for the MAIZE facility at the University of Michigan. Designed with a variable magnification (1–10×), this diagnostic achieves a spatial resolution of ~35 µm, which is useful for resolving the ~100-μm-scale coronal plasma immediately surrounding the dense core. This system has now been used on a reduced-output MAIZE (100–200 kA, 150 ns) to assess the radial distribution of drive current immediately surrounding the dense micro-pinch neck. The total current enclosed was found to increase as a function of radius, r, from a value of ≈ 50 ± 25 kA at r ≈ 140 µm (at the edge of the dense neck) to a maximal value of ≈150 ± 75 kA for r ≥ 225 µm. This corresponds to a peak magnetic drive pressure of ≈75 ± 50 kbar at r ≈ 225 µm. The limitations of these measurements are discussed in the paper.

47 OTHER INSTRUMENTATION↗

Source size of x rays from self-modulated laser wakefield accelerators

A comparative study of x-ray sources generated with different mechanisms from self-modulated laser wakefield acceleration (SM-LWFA) electrons was performed to compare the source size or spatial resolution for use in high energy density science applications. We examine the source size of betatron, inverse Compton scattering, and bremsstrahlung radiation with a Fresnel diffraction based formalism and a modified x-ray ray tracing model. We observe the dependence of source size on the radiation generation process, laser parameters, and compare to what is possible in other regimes of LWFA, as well as current methods. This information is significant as we begin to explore the use of light sources driven by SM-LWFA for use as a diagnostic at large-scale laser facilities where blowout regime LWFA is not possible.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ultrafast state-selective tunneling in two-dimensional semiconductors with a phase- and amplitude-controlled THz-scanning tunneling microscope

THz-pulse driven scanning tunneling microscopy (THz-STM) enables access to the ultrafast quantum dynamics of low-dimensional material systems at simultaneous ultrafast temporal and atomic spatial resolution. State-selective tunneling requires precise amplitude and phase control of the THz pulses combined with quantitative near-field waveform characterization. Here, we employ our state-of-the-art THz-STM with multi-MHz repetition rates, efficient THz generation, and precisely tunable THz waveforms to investigate a single sulfur vacancy in monolayer MoS2. We demonstrate that 2D transition metal dichalcogenides (TMDs) are an ideal platform for near-field waveform sampling by THz cross-correlation. Furthermore, we determine the THz voltage via QEV scans, which measure the THz rectified charge Q as a function of THz field amplitude E and dc bias Vdc. Mapping the complex energy landscape of localized states with a resolution down to 0.01 electrons per pulse facilitates state-selective tunneling to the HOMO and LUMO orbitals of a charged sulfur vacancy.

Materials Science↗

Evaluation of an x-ray multilayer mirror for radiography at sub-1-keV photon energies

An x-ray multilayer mirror on a spherical substrate designed for near-normal incidence with a photon energy of ~738 eV (F He α ) was procured and tested. This device is intended to be used for in-flight radiography of the shell in inertial confinement fusion experiments with cryogenic targets on the OMEGA laser at the Laboratory for Laser Energetics. Experiments in self-emission on a small (~10 J) laser system showed that the reflectivity of the mirror is high enough to record an image at laser energies as low as 0.1 J. Furthermore, a second set of tests in backlighting geometry on a larger (kJ)-scale, short-pulse laser yielded usable radiographs with laser energies as low as 40 J with a spatial resolution of ~10 μm.

47 OTHER INSTRUMENTATION↗

Laser-driven flash x-ray radiography of a shocked metallic foil

Characterizing hydrodynamic instability evolution in millimeter-scale, high-Z foils is crucial for understanding complex phenomena in high-energy-density physics. Here, we demonstrate a proof-of-concept, laser-driven flash x-ray radiography platform tailored for two-dimensional linear density mapping in shocked high-Z foils. Using chromium (Cr) foils with internal shockwaves (∼100 μm width), our platform achieves a spatial resolution of 59.8 ± 1.4 μm by employing a broadband x-ray source extending into the hundreds of keV range. The setup combines a compound parabolic concentrator cone with a tantalum wire target, a magnetic field to deflect residual transmitted electrons, and a copper casing to shield the sides and rear of the image plate pack. By varying the delay of the short-pulse beam driving the flash x-ray source, we resolve shockwave dynamics, specifically the velocity, position, width, and density profile, within the Cr foil. Reported experimental results are consistent with the corresponding hydrodynamics and radiation transport simulations, which accurately reproduce the measured electron and x-ray source terms. These developments enable the conversion of shockwave radiographs into two-dimensional density maps, enhancing interpretability for hydrodynamic instability evolution applications and validating the simulation approach.

36 MATERIALS SCIENCE↗

Applicability of alkali beam emission spectroscopy on NSTX-U

Understanding fast pedestal dynamics and turbulent transport in the edge and scrape-off layer (SOL) plasma of spherical tokamaks is crucial for the design and operation of future fusion reactors. The alkali beam emission spectroscopy diagnostic technique offers a means to measure the absolute electron density radial profile and fluctuation amplitude in these regions. Here, in this study, we demonstrate that injecting a sodium neutral beam radially into the plasma and analyzing the light emission from its 3p–3s atomic transition using near-orthogonal viewing angles allows for accurate measurement of the electron density profile and fluctuations in the National Spherical Torus Experiment (NSTX) Upgrade spherical tokamak. Our findings indicate a peak signal-to-noise ratio of 118 in the pedestal and 12 in the SOL under typical NSTX plasma conditions. The spatial resolution for the electron density profile is estimated to be between 2 and 8 mm, while for fluctuation measurements, it ranges from 12 to 15 mm.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electron cyclotron emission detection of neoclassical tearing modes for control for ITER

Successful operation of ITER requires control of magnetic instabilities including neoclassical tearing modes (NTMs) that can degrade confinement and lead to disruption. Low latency detection by electron cyclotron emission (ECE) diagnostics has been demonstrated in a few current experiments. Using a synthetic diagnostic, we demonstrate low latency NTM detection for ITER with plasmas described by ITER IMAS database scenarios and with realistic limitations imposed on the instrumentation by these high temperature scenarios. 2/1 NTMs are detected 430 ms after magnetic island seeding and before island locking. The radiometer configuration was optimized using simulation, and the smallest detectable island size was explored. Island sizes of ∼3 cm are detectable at the 2/1 surface. The simulated signals incorporate recent physics models for island growth and rotation, which show early locking and continued island growth after locking and before disruption. This work determines limits for ITER ECE spatial resolution imposed by relativistic broadening of channels, which informs hardware design. Real-time detection is demonstrated in hardware that is required by ITER, including on an NI PXI-7853R FPGA system. Development of a synthetic diagnostic and details of the hardware will be discussed.

Cyclotron radiation↗

Design of a low frequency, density profile reflectometer system for the MAST-U spherical tokamak

Validated and accurate edge profiles (temperature, density, etc.) are vitally important to the Mega Ampere Spherical Tokamak Upgrade (MAST-U) divertor and confinement effort. Density profile reflectometry has the potential to significantly add to the measurement capabilities currently available on MAST-U (e.g., Thomson scattering and Langmuir probes). This work presents the diagnostic requirements, problems, and solutions facing profile reflectometry in spherical tokamaks and MAST-U in particular. Requirements include density measurements near zero electron density in the scrape off layer region, coverage for a broad range of MAST-U plasma parameters, high time (≤10 microseconds) and spatial resolutions (≤1 cm), reliability, and identification of the plasma start frequency.

Instruments & Instrumentation↗

Imaging of dark line defect growth in high-power diode laser cavities using broadband near infrared light emission from the laser cavity

An in situ and nondestructive technique is developed to image the formation and evolution of dark line defects in the cavity of a high-power diode laser. Here, the technique uses broadband near infrared emission that originates in the laser's core layers and enables defects to be imaged with high spatial resolution through the substrate. In particular, it enables defect imaging through the substrate of shorter wavelength lasers, even when the substrate is opaque near the lasing wavelength. The evolution of dark line defects during aging is studied in several devices, with correlations established between the observed characteristics of defect growth and changes in device parameters such as optical power, operating wavelength, threshold current, and slope efficiency. Gradual degradation is found to be associated with dark line defects that slowly propagate from dark spots that are present in the device interior in its fresh (unaged) condition, rather than propagating from spots that are formed during aging, suggesting a strategy to screen fresh devices for expected reliability. This defect growth phenomenon is found to be particularly evident in the dark spots near the output facet.

47 OTHER INSTRUMENTATION↗