Fast On-The-Fly Monte Carlo Sampling of Temperature Dependent Thermal Scattering [Slides]

This presentation highlights the process of developing a thermal data library for MCNP6 to support on-the-fly S(alpha, beta) sampling for temperature ranges applicable to nuclear criticality safety. Advanced on-the-fly (OTF) strategy driven libraries have been developed for six materials based on ENDF/B-VIII.0. Validation of the OTF libraries is being conducted currently.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Characterizing the contribution of bioaerosols diversity from complex aerosol particle samples.

Current global change scenarios expect to significantly increase the contribution of pollen to the total organic aerosol budget. In addition, pollen can burst into smaller fragments that are highly efficient as cloud condensation nuclei. However, current climate models still do not incorporate the effects of these particles due to detection and quantification challenges in complex aerosol mixtures. Chemical biomarkers (i.e. fructose) have commonly been used to trace pollen but this approximation can generate false positive results given the large number of shared compounds between different bioaerosols. A previous pilot EMSL experiment performed on pure pollen samples suggested that using a set of metabolites as a fingerprint of bioaerosols could serve to substantially increase detection accuracy over single biomarker approaches. In this proposal we developed novel bioinformatic strategies to characterize and quantify complex pollen mixtures present in the atmosphere. For that, we used diverse machine learning algorithms to analyze metabolic fingerprints from complex mixtures of different pollen acquired with high-resolution mass spectrometry (Orbitrap Q-Exactive). Our preliminary results demonstrated the potential to accurately discern and identify at specific relative abundances different pollen species in complex mixtures. Our research will lead to a significant advancement in the atmospheric chemistry and provide much needed data to improve the accuracy of climate models.

54 ENVIRONMENTAL SCIENCES↗

Multiplexed Probing for Functional Capacity Measurements in Complex and Limited-Size Samples

A new strategy using glass as a solid support for functionalization with chemical probes has been recently developed with successful results. The next step in glass functionalization is to pair chemical probes with fluorescent glass microspheres. This approach gives us a way to directly quantify probe-bound protein using Fluorescence-Activated Cell Sorting (FACS). FACS has already shown to be amendable to glass microspheres, demonstrating changes in probe-bound protein concentration. Suitable probing conditions for gram-positive and negative microbes, complex microbial communities from myriad ecosystems, and eukaryotic cells/tissues have traditionally suffered from set-backs, such as limited protein per sample and conditions atypical for probing. To remedy this, we propose to: (1) Demonstrate probe functionalization specific to glass microspheres by paired fluorophore and use those activity probes successfully with proteomics. Probes that are currently available (CYP5, GSH/GST, Glycoside Hydrolase) can be easily prepared onto glass surfaces. Probe-bound microspheres can be tested in ratios, first with known amounts of purified protein and then complex microbiome lysates. (2) Our validated microspheres are then used to determine quantitative amounts of protein through FACS sorting. Complimenting these results by proteomics, prepared microspheres are then optimized and condensed into a user-friendly kit. Once successfully commercialized, this multiplexed assay can be used with little to no technical expertise, making this available to various industries users.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Lawrence Livermore National Laboratory Experimental Test Site 300: Energetic Materials Development Enclave (EMDEC) Soil Sampling and Analysis Plan Addendum 1 (April 2023)

The purpose of this addendum is to amend and update the Energetic Materials Development Enclave [project] Soil Sampling and Analysis Plan (SAP) dated June 2022 (LLNL-AM-22- 21678). In July 2022, portions of the SAP were completed. Since then, the project scope and limits have been redefined to include potential additional buildings. The exact locations of the additional buildings have not been determined, but the Project Management Office (PMO) would like to investigate at this time additional areas adjacent to the investigation area subject to the June 2022 SAP. The information contained in this addendum supersedes the June 2022 SAP. However, this addendum only addresses elements of the June 2022 SAP that were modified. Elements of the June 2022 SAP that have not been modified are relevant and will remain in effect.

54 ENVIRONMENTAL SCIENCES↗

Legacy Site 377 (Former Building 377) Soil Sampling and Analysis Plan Addendum 1 (April 2023)

The purpose of this addendum is to address data gaps identified in the Legacy Site 377 (Former Building 377) Soil Sampling and Analysis Plan (SAP) (LLNL-AM-826971) (LLNL 2021a) and the Phase II Site Assessment Report for Legacy Slab 377 (LLNL-TM-828194) (LLNL 2021b). This addendum will be used in conjunction with the 2021 SAP. All policies and procedures set forth in the SAP that are not modified in this addendum will remain in effect for the duration of the project, where applicable.

54 ENVIRONMENTAL SCIENCES↗

Double sided measurements and associated error bars for planar samples or subassemblies

Many of the high energy density (HED) experiments use targets with planar components usually in a multilayer stack as the physics package which is at the heart of the experiment. The physics package contains the sample part under study as well as other components as shown in Fig. 1, that when exposed to the laser drive applies pressure onto or shock the main component to take it to the desired state in the phase diagram. These other components may include the ablator, pusher, x-ray pre-heat shield, window or other special components. The components are usually glued together. Currently, experiments on NIF and Omega in the Dynamic Materials campaign use several platforms such as Diffraction, EOS and Strength (Ref 1-3) which all use such planar stack physics packages.

42 ENGINEERING↗

Determination of Total, Organic, and Inorganic Carbon and Total Nitrogen in Biological Cultures and Liquid Fraction Process Samples: Laboratory Analytical Procedure (LAP)

This Laboratory Analytical Procedure (LAP) describes the quantitative determination of total organic carbon, inorganic carbon in whole suspended biological samples and in the cell-free supernatant, by combustion and CO 2 detection with a non-dispersive infrared (NDIR) detector. This allows for distinct reporting of soluble and insoluble organic and inorganic carbon. In addition, this procedure covers the quantitative determination of soluble nitrogen in the cell-free supernatant.

09 BIOMASS FUELS↗

Assessment of the 3430 Building Filtered Exhaust Stack Sampling Probe Location: Stack Verification Following Fan and Air Blender Additions

The velocity uniformity and flow angle results from the 3430 stack verification tests, performed in April 2023, demonstrated that the CFD model results may be used to support the qualification of the stack sampling location. The measured velocity uniformity verification test result was 2.1 %COV. This value is well within the uniformity criterion, which is that the velocity uniformity be =20 %COV. Additionally, this value is well within the criterion that the actual stack measurement must be within 5% of the surrogate stack (i.e., CFD modeled stack); in this case the CFD modeled average result of 2.85 %COV for the nominal operating range of 22,800 cfm to 62,400 cfm. Additionally, the measured average flow angle at the 3430 stack monitor location was 5.6 degrees. The result is =20 degrees, so the criterion is met.

3430 Building↗

(U) A Tool to Set Up an MCNP6 Input to Use Correlated Sampling with Batch Statistics

Correlated sampling using batch statistics with MCNP6’s tally fluctuation charts (TFCs) is a powerful means of reducing the statistical uncertainties of various combinations of tallies. Because MCNP6 prints a maximum of 20 entries in the TFCs, at least five inputs must be run to obtain the recommended number of at least 100 batches. A new software tool, MAKE_COSUBS, reads an MCNP6 input file and sets up a sequence of input files to be run. The user runs MAKE_COSUBS for the unperturbed and all perturbed MCNP6 inputs, runs MCNP6 for the inputs, and finally analyzes the outputs using COSUBS.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Sample Testing Basket: Design and Capabilities Report

SFR designs all require integral components that can withstand prolonged submersion in the liquid sodium primary coolant as well as in the gas space of the reactor vessel. Materials are often desired to withstand these conditions for the lifetime of the reactor. The Sample Testing Basket (STB) was designed and fabricated to meet the anticipated need for material exposure testing in prototypic reactor coolant environments; in the liquid sodium primary coolant and the sodium-vapor-laden gas space. Developed at Argonne National Laboratory (ANL), the STB is a piece of equipment designed for use in the Mechanisms Engineering Test Loop (METL) to allow for sodium exposure testing of materials within the METL facility.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Controlling radioisotope proportions when randomly sampling from Dirichlet distributions in PyRIID

As machine learning models for radioisotope quantification become more powerful, likewise the need for high-quality synthetic training data grows as well. For problem spaces that involve estimating the relative isotopic proportions of various sources in gamma spectra it is necessary to generate training data that accurately represents the variance of proportions encountered. In this report, we aim to provide guidance on how to target a desired variance of proportions which are randomly when using the PyRIID Seed Mixer, which samples from a Dirichlet distribution. We provide a method for properly parameterizing the Dirichlet distribution in order to maintain a constant variance across an arbitrary number of dimensions, where each dimension represents a distinct source template being mixed. We demonstrate that our method successfully parameterizes the Dirichlet distribution to target a specific variance of proportions, provided that several conditions are met. This allows us to follow a principled technique for controlling how random mixture proportions are generated which are then used downstream in the synthesis process to produce the final, noisy gamma spectra.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Absolute Color Calibration of the Dark Energy Survey: A Spectrophotometric Sample of DA White Dwarfs in the Southern Sky

The Dark Energy Survey (DES), which is nearing the completion of the analysis of its full data set, is an imaging survey of one-quarter of the Southern sky down to an apparent magnitude of $i\sim24.5$. The survey observations were conducted between 2013 and 2019 with a 3-square-degree wide-field CCD mosaic camera (the Dark Energy Camera, or DECam) on the Blanco 4-meter telescope at the Cerro Tololo Interamerican Observatory in the Chilean Andes. The primary scientific goal of the DES was to measure properties of Dark Energy. In order to achieve its science goals, the DES had tight requirements on both its relative and absolute photometric calibrations. In this poster, we describe the sample of pure-hydrogen-atmosphere (“DA”) white dwarfs which were instrumental in working to establish the requirement on the absolute color calibration -- i.e., the calibration across the filter bands -- of the DES.

79 ASTRONOMY AND ASTROPHYSICS↗

Organic Evaporation, Oxidation, and Hydrolysis Testing in Support of Hanford Sample-and-Send

The Hanford site has approximately 54 to 56 million gallons of radioactive mixed waste stored in 156 unretrieved underground storage tanks. The Hanford Waste Treatment and Immobilization Plant (WTP) is being built to treat and immobilize the tank waste. The baseline method for immobilization of Low Activity Waste (LAW) through the WTP is vitrification, but additional immobilization capacity is needed to supplement the initial LAW melters. An alternative cementitious waste form is being investigated for that future immobilization method. However, one impediment to a cementitious waste form is the presence of Land Disposal Restricted (LDR) organic chemicals in tank waste, which are regulated on a concentration based standard in the final waste form. Hence, if the quantity of organics in LAW is high enough, they must be destroyed or removed to make a waste form compatible with disposal in a mixed low level waste landfill. This work evaluates potential avenues for treatment of LDR organics to eliminate the impediment and permit possible use of a cementitious waste form. Vacuum evaporation testing to remove LDR organics consisted of preparing a non-radioactive LAW simulant, spiking that simulant with organic chemicals, and evaporating the mixture via differential distillation. The apparatus was a laboratory-scale vacuum evaporator operated at 60 ±5 torr absolute (vacuum evaporation). The LAW simulant represented the liquid expected to be retrieved from the Hanford tank farms at approximately 4.0 M [Na+] total sodium ion concentration. The concentration of the organic chemicals added was significantly higher than typically found in the tank waste samples since the higher levels were necessary to assist in analytical measurement and tracking of the spiked species.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

233 U oxide Measurement Campaign Data: Passive and Active Neutron Multiplicity Measurements of Uranium Oxide Samples at Oak Ridge National Laboratory

During FY2023, three measurement campaigns were conducted at Oak Ridge National Laboratory. The goal was to quantify the neutron signatures of samples of uranium oxide containing uranium 233 and uranium-235. This report presents the neutron multiplicity data obtained using the large volume active well coincidence counter (LV-AWCC).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗