At least 1,081 records · Page 60

A Transformer-less Partial Power Boost Converter for PV Applications Using a Three-Level Switching Cell

Photovoltaic architectures with distributed power electronics provide many advantages in terms of energy yield as well as system level optimization. As the power level of the solar farm increases it becomes more beneficial to increase the dc collection network voltage, which requires the use of power devices with higher voltage ratings, and thus making the design of efficient, low cost, distributed power converters more challenging. In this paper a simple partial power converter topology is proposed. The topology is implemented using a three-level switching cell, which allows the use of semiconductor devices with lower voltage rating; thus improving design and performance and reducing converter cost. This makes the converters suitable for use for medium to high power applications where dc-link voltages of 600V~1kV may be needed without the need for high voltage devices. Converter operation and experimental results are presented for two partial power circuit variants using three-level switching cells.

14 SOLAR ENERGY↗

Ultrananocrystalline diamond films with optimized dielectric properties for advanced RF MEMS capacitive switches

An efficient deposition process is provided for fabricating reliable RF MEMS capacitive switches with multilayer ultrananocrystalline (UNCD) films for more rapid recovery, charging and discharging that is effective for more than a billion cycles of operation. Significantly, the deposition process is compatible for integration with CMOS electronics and thereby can provide monolithically integrated RF MEMS capacitive switches for use with CMOS electronic devices, such as for insertion into phase array antennas for radars and other RF communication systems.

36 MATERIALS SCIENCE↗

DISCRETE EVENT SIMULATION OF OPTICAL SWITCH MATRIX PERFORMANCE IN COMPUTER NETWORKS

In this paper, we present application of a Discrete Event Simulator (DES) for performance modeling of optical switching devices in computer networks. Network simulators are valuable tools in situations where one cannot investigate the system directly. This situation may arise if the system under study does not exist yet or the cost of studying the system directly is prohibitive. Most available network simulators are based on the paradigm of discrete-event-based simulation. As computer networks become increasingly larger and more complex, sophisticated DES tool chains have become available for both commercial and academic research. Some well-known simulators are NS2, NS3, OPNET, and OMNEST. For this research, we have applied OMNEST for the purpose of simulating multi-wavelength performance of optical switch matrices in computer interconnection networks. Our results suggest that the application of DES to computer interconnection networks provides valuable insight in device performance and aids in topology and system optimization.

Imam, Neena↗

Switching coordination of distributed dc-dc converters for highly efficient photovoltaic power plants

A distributed photovoltaic (PV) power plant includes a plurality of distributed dc-dc converters. The dc-dc converters are configured to switch in coordination with one another such that at least one dc-dc converter transfers power to a common dc-bus based upon the total system power available from one or more corresponding strings of PV modules. Due to the coordinated switching of the dc-dc converters, each dc-dc converter transferring power to the common dc-bus continues to operate within its optimal efficiency range as well as to optimize the maximum power point tracking in order to increase the energy yield of the PV power plant.

14 SOLAR ENERGY↗

Method and allocation device for allocating pending requests for data packet transmission at a number of inputs to a number of outputs of a packet switching device in successive time slots

A method for allocating pending requests for data packet transmission at a number of inputs to a number of outputs of a switching system in successive time slots, including a matching method including the steps of providing a first request information in a first time slot indicating data packets at the inputs requesting transmission to the outputs of the switching system, performing a first step in the first time slot depending on the first request information to obtain a first matching information, providing a last request information in a last time slot successive to the first time slot, performing a last step in the last time slot depending on the last request information and depending on the first matching information to obtain a final matching information, and assigning the pending data packets at the number of inputs to the number of outputs based on the final matching information.

97 MATHEMATICS AND COMPUTING↗

High voltage switch triggered by a laser-photocathode subsystem

A spark gap switch for controlling the output of a high voltage pulse from a high voltage source, for example, a capacitor bank or a pulse forming network, to an external load such as a high gradient electron gun, laser, pulsed power accelerator or wide band radar. The combination of a UV laser and a high vacuum quartz cell, in which a photocathode and an anode are installed, is utilized as triggering devices to switch the spark gap from a non-conducting state to a conducting state with low delay and low jitter.

43 PARTICLE ACCELERATORS↗

Combustion mode switching with a turbocharged/supercharged engine

A method for switching between low- and high-dilution combustion modes in an internal combustion engine having an intake passage with an exhaust-driven turbocharger, a crankshaft-driven positive displacement supercharger downstream of the turbocharger and having variable boost controllable with a supercharger bypass valve, and a throttle valve downstream of the supercharger. The current combustion mode and mass air flow are determined. A switch to the target combustion mode is commanded when an operating condition falls within a range of predetermined operating conditions. A target mass air flow to achieve a target air-fuel ratio corresponding to the current operating condition and the target combustion mode is determined. The degree of opening of the supercharger bypass valve and the throttle valve are controlled to achieve the target mass air flow. The amount of residual exhaust gas is manipulated.

33 ADVANCED PROPULSION SYSTEMS↗

Data center coolant switch

A data center cooling system is operated in a first mode; it has an indoor portion wherein heat is absorbed from components in the data center, and an outdoor heat exchanger portion wherein outside air is used to cool a first heat transfer fluid (e.g., water) present in at least the outdoor heat exchanger portion of the cooling system during the first mode. The first heat transfer fluid is a relatively high performance heat transfer fluid (as compared to the second fluid), and has a first heat transfer fluid freezing point. A determination is made that an appropriate time has been reached to switch from the first mode to a second mode. Based on this determination, the outdoor heat exchanger portion of the data cooling system is switched to a second heat transfer fluid, which is a relatively low performance heat transfer fluid, as compared to the first heat transfer fluid. It has a second heat transfer fluid freezing point lower than the first heat transfer fluid freezing point, and the second heat transfer fluid freezing point is sufficiently low to operate without freezing when the outdoor air temperature drops below a first predetermined relationship with the first heat transfer fluid freezing point.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Laser based analysis using a passively Q-switched laser employing analysis electronics and a means for detecting atomic optical emission of the laser media

A device for Laser based Analysis using a Passively Q-Switched Laser comprising an optical pumping source optically connected to a laser media. The laser media and a Q-switch are positioned between and optically connected to a high reflectivity mirror (HR) and an output coupler (OC) along an optical axis. The output coupler (OC) is optically connected to the output lens along the optical axis. A means for detecting atomic optical emission comprises a filter and a light detector. The optical filter is optically connected to the laser media and the optical detector. A control system is connected to the optical detector and the analysis electronics. The analysis electronics are optically connected to the output lens. The detection of the large scale laser output production triggers the control system to initiate the precise timing and data collection from the detector and analysis.

47 OTHER INSTRUMENTATION↗

Solid-state active switch matrix for high energy, moderate power battery systems

A battery management system employs electronic switches and capacitors. No traditional cell-balancing resistors are used. The BMS electronically switches individual cells into and out of a module of cells in order to use the maximum amount of energy available in each cell and to completely charge and discharge each cell without overcharging or under-discharging.

25 ENERGY STORAGE↗

R&D100: 6.5kV Enhancement-Mode Silicon Carbide JFET Switch

Researchers at Sandia National Laboratories have partnered with United Silicon Carbide, Inc. to combine advanced materials with novel manufacturing ideas to build a new product for significantly more efficient power conversion. Harnessing the unique features of silicon carbide, this first of its kind device allows higher voltage switching, and reductions in switching losses to significantly boost the efficiency and reliability of power generation and power conversion.

24 POWER TRANSMISSION AND DISTRIBUTION↗

High-density, fail-in-place switches for computer and data networks

A structure for a network switch. The network switch may include a plurality of spine chips arranged on a plurality of spine cards, where one or more spine chips are located on each spine card; and a plurality of leaf chips arranged on a plurality of leaf cards, wherein one or more leaf chips are located on each leaf card, where each spine card is connected to every leaf chip and the plurality of spine chips are surrounded on at least two sides by leaf cards.

97 MATHEMATICS AND COMPUTING↗

Switch device having a non-linear transmission line

Switching devices are provided. The switching devices include an input electrode, having a main electrode and a trigger electrode, and an output electrode. The main electrode and the trigger electrode are separated from the output electrode by a main gap and a trigger gap, respectively. During operation, the trigger electrode compresses and amplifies a trigger voltage signal causing the trigger electrode to emit a pulse of energy. This pulse of energy form plasma near the trigger electrode, either by arcing across the trigger gap, or by arcing from the trigger electrode to the main electrode. This plasma decreases the breakdown voltage of the main gap. Simultaneously, or near simultaneously, a main voltage signal propagates through the main electrode. The main voltage signal emits a main pulse of energy that arcs across the main gap while the plasma formed by the trigger pulse is still present.

47 OTHER INSTRUMENTATION↗

Apparatus and method for fusion of compute and switching functions of exascale system into a single component by using configurable network-on-chip fabric with distributed dual mode input-output ports and programmable network interfaces

Described is an apparatus which comprises: a Network-On-Chip fabric using crossbar switches, having distributed ingress and egress ports; and a dual-mode network interface coupled to at least one crossbar switch, the dual-mode network interface is to include: a dual-mode circuitry; a controller operable to: configure the dual-mode circuitry to transmit and receive differential signals via the egress and ingress ports, respectively, and configure the dual-mode circuitry to transmit and receive signal-ended signals via the egress and ingress ports, respectively.

97 MATHEMATICS AND COMPUTING↗

Magnetoelectric memory cells with domain-wall-mediated switching

A magnetoelectric memory cell with domain-wall-mediated switching is implemented using a split gate architecture. The split gate architecture allows a domain wall to be trapped within a magnetoelectric antiferromagnetic (MEAF) active layer. An extension of this architecture applies to multiple-gate linear arrays that can offer advantages in memory density, programmability, and logic functionality. Applying a small anisotropic in-plane shear strain to the MEAF can block domain wall precession to improve reliability and speed of switching.

42 ENGINEERING↗

Comparison of 22 kHz and 85 kHz 50 kW Wireless Charging System Using Si and SiC Switches for Electric Vehicle

Fast charging in transportation application requires high-power (>50 kW) operation. The overall size of wireless charging systems (WCS) must increase to meet the high-power requirement. As a result, high power systems produce more electromagnetic field (EMF) emissions. Although higher operating frequencies (85 kHz) reduce the size of inductors and capacitors, system losses tend to increase. High-power systems are traditionally investigated for 10 kHz to 22 kHz operation to reduce the switching loss in the converter, and conductive and magnetic losses in the power pad. The use of SiC MOSFETs reduces conduction and switching losses in the converter even at higher frequencies. In this paper, a comprehensive loss comparison of 50 kW wireless charging system is conducted for 85 kHz and 22 kHz operation of Si MOSFET and SiC MOSFET converters. Detailed performance indexes are compared analytically as a function of frequency and verified using FEA and PLECS. This comprehensive system level study shows that magnetic losses can be reduced significantly, and that EMF emission can be reduced by 50% by moving from 22 kHz to 85 kHz. Moreover, the system requires 50% less copper and allows a significant reduction in the size of the primary and secondary filter capacitor at 85 kHz. The results show that the system efficiency at 85 kHz can be increased by 21% compared to 22 kHz operation by using a SiC MOSFET converter.

Shahidul haque, Moinul↗

Switching strategy for increased efficiency of power converters

Systems and methods for operating a power converter are provided. A DC to AC converter can include an inner converter and an outer converter. The inner converter can include an isolation transformer a first plurality of switching devices. The outer converter can include a second plurality of switching devices. A control method can include determining an output voltage of the outer converter. The control method can further include controlling operation of the inner converter based at least in part on the output voltage of the outer converter.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Three-dimensional co-axial linear photonic switch

Techniques, systems, and devices are disclosed that relate to coaxial photoconductive switch modules. The coaxial photoconductive switch may include an outer conductor, an inner conductor, and a photoconductive material positioned between the inner conductor and the outer conductor. The inner conductor, the outer conductor, and the photoconductive material have a predetermined height. A bias voltage may be applied between the inner conductor and the outer conductor. When light of a predetermined wavelength and a predetermined intensity is incident on the photoconductive material, the photoconductive material may break down allowing a current to flow through the photoconductive material between the inner conductor and the outer conductor.

Conway, Adam↗