Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SINGLE IONS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

Current State of Domestic Heavy Ion Test Facilities

We present the current status of United States domestic heavy ion single-event effects (SEE) radiation test facilities, including general perspectives on near- and mid-term needs for both capacity and capabilities.

Jonathan Pellish↗

ATOMIC FORCE LITHOGRAPHY OF NANO MICROFLUIDIC CHANNELS FOR VERIFICATION AND MONITORING IN AQUEOUS SOLUTIONS

The growing interest in the physics of fluidic flow in nanoscale channels, as well as the possibility for high sensitive detection of ions and single molecules is driving the development of nanofluidic channels. The enrichment of charged analytes due to electric field-controlled flow and surface charge/dipole interactions along the channel can lead to enhancement of sensitivity and limits-of-detection in sensor instruments. Nuclear material processing, waste remediation, and nuclear non-proliferation applications can greatly benefit from this capability. Atomic force microscopy (AFM) provides a low-cost alternative for the machining of disposable nanochannels. The small AFM tip diameter (< 10 nm) can provide for features at scales restricted in conventional optical and electron-beam lithography. This work presents preliminary results on the fabrication of nano/microfluidic channels on polymer films deposited on quartz substrates by AFM lithography.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

ATOMIC FORCE LITHOGRAPHY OF NANO/MICROFLUIDIC CHANNELS FOR VERIFICATION AND MONITORING OF AQUEOUS SOLUTIONS

The growing interest in the physics of fluidic flow in nanoscale channels, as well as the possibility for high sensitive detection of ions and single molecules is driving the development of nanofluidic channels. The enrichment of charged analytes due to electric field-controlled flow and surface charge/dipole interactions along the channel can lead to enhancement of sensitivity and limits-of-detection in sensor instruments. Nuclear material processing, waste remediation, and nuclear non-proliferation applications can greatly benefit from this capability. Atomic force microscopy (AFM) provides a low-cost alternative for the machining of disposable nanochannels. The small AFM tip diameter (< 10 nm) can provide for features at scales restricted in conventional optical and electron-beam lithography. This work presents preliminary results on the fabrication of nano/microfluidic channels on polymer films deposited on quartz substrates by AFM lithography.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Turning Ocean Water into Drinking Water

Tiny carbon nanotubes could be the future of drinking water. Livermore researchers are finding ways to make it cheaper and easier to desalinate ocean water, making it safe to drink.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Uptake selectivity for different types of zeolites in the presence of boric acid - 15244

The development of selective adsorbents is very important subject for the effective multi-nuclide decontamination related to the severe accident of Fukushima NPP-1. Many removal methods have been developed to separate nuclide from decontaminated solutions containing multi-nuclide so far. From the standpoint of cost efficiency, stability for usage and safety handling, the decontamination methods using inorganic adsorbents are one of the most effective methods for the selective decontamination system. Thus, many researches related to inorganic adsorbents have been carried out after the accident; actually, in Fukushima NPP-1, zeolites are used to remove radioactive nuclides from decontaminated water as a main adsorbent in the circulating injection cooling system. However, the adsorption characteristics of zeolites in the presence of boric acid have not been clarified in detail. As for the decontamination in PWR[1], the adsorption properties should be examined in the presence of highly concentrated boric acid. Based on this background, the final objective of this study is to develop the decontamination methods in PWR-NPP by using various zeolites for multi-nuclide. In this study, the adsorption properties for eight kinds of zeolites (Zeolite A, Zeolite X, Zeolite Y, Zeolite L, Chabazite, Synthetic Mordenite, Natural Mordenite and Clinoptilolite) are evaluated in the presence of boric acid and seawater. The present study deals with (1) selective adsorption properties for single nuclide ion ({sup 137}Cs{sup +}, {sup 60}Co{sup 2+}, {sup 85}Sr{sup 2+} and {sup 152}Eu{sup 3+}), (2) preparation of Ag-loaded Natural Mordenite (Ag-NM) and uptake properties of I- ions, and (3) multi-nuclide decontamination properties of 26 elements (typical elements in Advanced Liquid Processing System (ALPS) in Fukushima NPP-1) for the above zeolites. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Ni-Rich Li[Ni x MnyCo 1– x – y ]O 2 Single Crystals as Superior Fast Charge Cathodes for Lithium-Ion Batteries

The utilization of single-crystal (SC) Li[Ni x MnyCo 1-x-y ]O 2 (NMC) cathodes has facilitated unparalleled performance in commercial high-energy lithium-ion batteries (LIBs). In the current study, we evaluate the application of SC cathodes in fast charge (FC)-LIBs where particle cracking is a predominant failure mechanism. Ni-rich SC-NMC samples with various compositions, sizes, and shapes are synthesized and investigated for their influence on FC performance. We reveal the necessity of utilizing smaller SCs (<1 μm) as larger sizes (>2 μm) experience significant particle-level lithium concentration gradients under FC conditions. To improve lithium transport and minimize side reactivities, we strategically expose the (104) crystal facets on the surface. Exceptional performance was observed on an optimized SC-LiNi 0.80 Mn 0.05 Co 0.15 O 2 , delivering a discharge capacity of 165 mAh/g even after 150 cycles at 6C charge. Our study not only demonstrates the promise of SC-NMC but also provides the key insights for the design and optimization of advanced cathodes for FC-LIBs.

25 ENERGY STORAGE↗

The Mn-53-Cr-53 System in CAIs: An Update

High precision techniques have been developed for the measurement of Cr isotopes on the Triton mass spectrometer, at JPL. It is clear that multiple Faraday cup, simultaneous ion collection may reduce the uncertainty of isotope ratios relative to single Faraday cup ion collection, by the elimination of uncertainties from ion beam instabilities (since ion beam intensities for single cup collection are interpolated in time to calculate isotope ratios), and due to a greatly increased data collection duty cycle, for simultaneous ion collection. Efforts to measure Cr by simultaneous ion collection have not been successful in the past. Determinations on Cr-50-54Cr, by simultaneous ion collection on the Finnigan/ MAT 262 instrument at Caltech, resulted in large variations in extrinsic precision, for normal Cr, of up to 1% in Cr-53/Cr-52 (data corrected for mass fractionation, using Cr-50/Cr-52).

Papanastassiou, D. A.↗

Improvement in the Mass Resolution of Single Particle Mass Spectrometry Using Delayed Ion Extraction

A specific delayed ion extraction (DIE) technique, which combines a standard rectangular extraction pulse with an exponential pulse, was introduced for a single particle mass spectrometry (SPMS) instrument, and it can focus ions in a wide mass range and results in a mass resolution improvement for the mass range of the studied ions. The experimental results indicate that the average mass resolution for positive ions is about 1000 when the mass-to-charge ratio (m/z) is greater than 70, and for negative ions, when the m/z is greater than 70, the average resolution can reach 2000. The highest mass resolutions achieved so far are 1260 for positive ions and 2400 for negative ions for SPMS, which are very beneficial for mass peak interpretation and chemical compound identification. The primary applications for atmospheric particle measurements show that the high mass resolution of SPMS with the DIE technique is very beneficial for the analysis of carbon and metallic element containing particles, and {sup 39}K{sup +} with C{sub 3}H{sub 3}{sup +} and {sup 41}K{sup +} and C{sub 3}H{sub 5}{sup +} in organic particles were successfully differentiated using SPMS. The results indicate that SPMS with DIE technique can significantly ease mass peak interpretation and improve the mass assignment ability during analysis. Furthermore, existing SPMS instruments can be improved by a facile retrofitting process to implement the DIE technique. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TEM investigation of the surface layer structure [111]{sub B2} of the single NiTi crystal modified by the Si-ion beam implantation

The study was carried on for the single NiTi crystals subjected to the Si-ion beam implantation. Using the transmission electron microscopy technique (TEM), the surface layer structure [111]{sub B2} was examined for the treated material. The modified near-surface sublayers were found to have different composition. Thus the uppermost sublayer contained mostly oxides; the lower-lying modified sublayer material was in an amorphous state and the thin underlying sublayer had a defect structure.

36 MATERIALS SCIENCE↗

Near-infrared-to-near-infrared down-shifting and upconversion luminescence of KY{sub 3}F{sub 10} with single dopant of Nd{sup 3+} ion

We have studied the structural and near-infrared (NIR) luminescent properties of KY{sub 3}F{sub 10} phosphors, singly doped with Nd{sup 3+} serving as both sensitizer and activator. With a single laser diode at the wavelength of 808 nm as a pump source, simultaneous NIR-to-NIR upconversion (UC) and down-shifting (DS) emissions are effectively achieved, due to the specific energy levels of Nd{sup 3+} dopant and the low phonon energy of the host. The luminescence mechanism related to energy transfer is discussed. The luminescence can be modulated through controlling the population of Nd{sup 3+}:{sup 4}F{sub 3/2} state in our experiment. Interestingly, both UC and DS emissions of the material fall within the dual biological window, suggesting that the prepared phosphors have potential applications in the bioimaging field.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Single crystal silicon carbide detector of emitted ions and soft x rays from power laser-generated plasmas

A single-crystal silicon carbide (SiC) detector was used for measurements of soft x rays, electrons, and ion emission from laser-generated plasma obtained with the use of the Prague Asterix Laser System (PALS) at intensities of the order of 10{sup 16} W/cm{sup 2} and pulse duration of 300 ps. Measurements were performed by varying the laser intensity and the nature of the irradiated target. The spectra obtained by using the SiC detector show not only the photopeak due to UV and soft x-ray detection, but also various peaks due to the detection of energetic charged particles. Time-of-flight technique was employed to determine the ion kinetic energy of particles emitted from the plasma and to perform a comparison between SiC and traditional ion collectors. The detector was also employed by inserting absorber films of different thickness in front of the SiC surface in order to determine, as a first approximation, the mean energy of the soft x-ray emission from the plasma.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gas field ion source from an Ir/W<111> single-atom tip

We show that a thermally stable Ir/W<111> single-atom tip is a very good point ion source for rare gases (He, Ar) and reactive gases (H{sub 2}, O{sub 2}). The ion beams are emitted from the topmost atom with a very small opening angle (<1 deg.) and, most importantly, they exhibit high brightness. In addition, the ion currents are very stable. These good properties together with the long lifetime of the tip and the reliable tip preparation method make this tip especially suitable for applications in gas field ion source focused ion beam systems.

43 PARTICLE ACCELERATORS↗

Structural Underpinnings of the Enhanced Cycling Stability upon Al-Substitution in LiNi 0.45 Mn 0.45 Co 0.1-y Al y O 2 Positive Electrode Materials for Li-ion Batteries

Single-phase LiNi 0.45 Mn 0.45 Co 0.1-y Al y O 2 layered oxide materials with 0 ≤ y ≤ 0.10 were prepared using the glycine-nitrate combustion method. Al-substitution has a minimal effect on the defect concentration and rate capability of the materials, but raises the operating voltage and reduces the capacity fade of the materials during prolonged cycling compared to the unsubstituted system. In situ X-ray diffraction suggests the presence of Al has a significant structural impact during battery operation. It acts to limit the changes in lattice parameters observed during electrochemical charging and cycling of the materials. High-resolution X-ray diffraction reveals structural distortions in the transition metal layers of as-synthesized powders with high Al-contents, as well as a structural evolution seen in all materials after cycling.

36 MATERIALS SCIENCE↗

Comet Giacobini-Zinner - In situ observations of energetic heavy ions

Conclusive evidence is presented for the existence of heavy energetic, singly charged cometary ions within 1.5 million km of comet Giacobini-Zinner. The most direct evidence for establishing the mass of these ions was obtained from an analysis of the energy signals in one of the solid state detector on board the International Cometary Explorer. Maximum fluxes were recorded approximately one hour before and after closest approach to the cometary nucleus. Transformation of the particle angular distribution observed at approximately 50,000 km radial distance from the comet, during the inbound pass into a rest frame in which the distributions are nearly isotropic, requires a transformation velocity that is consistent with the local solar wind velocity (assuming these particles are primarily singly ionized with a mass of 18 + or - 6 amu). It is implied that these water-group ions underwent strong pitch angle scattering subsequent to ionization and that they were accelerated or heated. The derived ion density, approximately 0.1/cu cm, is consistent with a crude model for the production and transport of pickup ions.

Ipavich, F. M.↗

Ion dynamics in a linear radio-frequency trap with a single cooling laser

We analyze the possibility of cooling ions with a single laser beam, due to the coupling between the three components of their motion induced by the Coulomb interaction. For this purpose, we numerically study the dynamics of ion clouds of up to 140 particles, trapped in a linear quadrupole potential and cooled with a laser beam propagating in the radial plane. We use molecular dynamics simulations and model the laser cooling by a stochastic process. For each component of the motion, we systematically study the dependence of the temperature on the anisotropy of the trapping potential. Results obtained using the full radio-frequency (rf) potential are compared to those of the corresponding pseudopotential. In the rf case, the rotation symmetry of the potential has to be broken to keep ions inside the trap. Then, as for the pseudopotential case, we show that the efficiency of the Coulomb coupling to thermalize the components of motion depends on the geometrical configuration of the cloud. Coulomb coupling appears to be not efficient when the ions organize as a line or a pancake and the three components of motion reach the same temperature only if the cloud extends in three dimensions.

74 ATOMIC AND MOLECULAR PHYSICS↗