Interferometric bunch length measurements of 3 MeV picocoulomb electron beams

We report picosecond bunch length measurements using an interferometric method for a 3 MeV electron beam having bunch charge ranging from 1 to 14 pC. The method senses the single-cycle sub-terahertz (THz) pulse emitted by each electron bunch as coherent transition radiation which, in turn, is analyzed using a Michelson-type interferometer, forming an interferogram that is then processed to yield the nominal electron bunch length. This sub-THz coherent radiation intensity was measured using a quasi-optical detector (QOD) operated at room temperature. This experiment was quite challenging since the divergence angle of the sub-THz pulse emitted by the low-energy electron bunch exceeds ±10°, and its pulse energy at the entrance to the detector was as low as 100 pJ. When compared to a conventional helium-cooled silicon composite bolometer designed for frequencies above 0.5 THz, the QOD provided much better signal-to-noise ratio in the ~80 GHz frequency range, which was critical for the successful measurement of the bunch length.

36 MATERIALS SCIENCE↗

Synthetic CT: Simulating low dose single and dual energy protocols from a dual energy scan

Purpose: The choice of CT protocol can greatly impact patient dose and image quality. Since acquiring multiple scans at different techniques on a given patient is undesirable, the ability to predict image quality changes starting from a high quality exam can be quite useful. While existing methods allow one to generate simulated images of lower exposure (mAs) from an acquired CT exam, the authors present and validate a new method called synthetic CT that can generate realistic images of a patient at arbitrary low dose protocols (kVp, mAs, and filtration) for both single and dual energy scans. Methods: The synthetic CT algorithm is derived by carefully ensuring that the expected signal and noise are accurate for the simulated protocol. The method relies on the observation that the material decomposition from a dual energy CT scan allows the transmission of an arbitrary spectrum to be predicted. It requires an initial dual energy scan of the patient to either synthesize raw projections of a single energy scan or synthesize the material decompositions of a dual energy scan. The initial dual energy scan contributes inherent noise to the synthesized projections that must be accounted for before adding more noise to simulate low dose protocols. Therefore, synthetic CT is subject to the constraint that the synthesized data have noise greater than the inherent noise. The authors experimentally validated the synthetic CT algorithm across a range of protocols using a dual energy scan of an acrylic phantom with solutions of different iodine concentrations. An initial 80/140 kVp dual energy scan of the phantom provided the material decomposition necessary to synthesize images at 100 kVp and at 120 kVp, across a range of mAs values. They compared these synthesized single energy scans of the phantom to actual scans at the same protocols. Furthermore, material decompositions of a 100/120 kVp dual energy scan are synthesized by adding correlated noise to the initial material decompositions. The aforementioned noise constraint also allows us to compute feasible mAs values that can be synthesized for each kVp. Results: The single energy synthesized and actual reconstructed images exhibit identical signal and noise properties at 100 kVp and at 120 kVp, and across a range of mAs values. For example, the noise in both the synthesized and actual images at 100 kVp increases by {radical}(2) when the mAs is halved. The synthesized and actual material decompositions of a dual energy protocol show excellent agreement when the decomposition images are linearly weighted to form monoenergetic images at energies from 40 to 100 keV. For simulated single energy protocols with kVp between 80 and 140, the highest feasible mAs exceeds that of either initial scan. Conclusions: This work describes and validates the synthetic CT theory and algorithm by comparing its results to actual scans. Synthetic CT is a powerful new tool that allows users to realistically see how protocol selection affects CT images and enables radiologists to retrospectively identify the lowest dose protocol achievable that provides diagnostic quality images on real patients.

61 RADIATION PROTECTION AND DOSIMETRY↗

Calibrated Radar Wind Profiler (RWP) Moments

The SGP Central Facility (C1) radar wind profiler (RWP) was calibrated using nearby surface disdrometer observations. Between 2011 and 2019, the SGP C1 RWP operated in two modes. The vertically pointing mode (named the precipitation mode) transmitted a short and long pulse length to have two different range resolutions and the beam-swinging mode (named the wind mode) transmitted one pulse length into three different beam directions. The precipitation-mode observations were available and calibrated from April 2011 through mid-August 2019. The wind-mode observations were available and calibrated between April 2014 and March 2019. The RWP spectra were processed to account for Nyquist velocity aliasing and coherent integration filtering effects before calculating the spectrum moments. During intense precipitation events, the calculated signal-to-noise ratio (SNR) is biased low due to signal power being distributed across the velocity spectrum such that some signal power is erroneously included in the noise level estimate, causing the noise level to be biased high. To correct for the low SNR bias, a new noise level is estimated using observations without precipitation and the SNR is increased accordingly. The adjusted SNR was converted to radar reflectivity factor and then calibrated against a nearby surface disdrometer. The calibration methodology is fully described in: Williams, CR, J Barrio, PE Johnston, P Muradyan, and S Giangrande. 2023. “Calibrating radar wind profiler reflectivity factor using surface disdrometer observations.” Atmospheric Measurement Techniques, https://egusphere.copernicus.org/preprints/2023/egusphere-2022-1405/

54 ENVIRONMENTAL SCIENCES↗

Boreal Winter Predictions with the GEOS-2 GCM: The Role of Boundary Forcing and Initial Conditions

Ensembles of atmospheric General Circulation Model (GCM) seasonal forecasts and long-term simulations (1980-94) are analyzed to assess the controlling influences of boundary forcing and memory of the initial conditions. Both the forecasts and simulations are carried out with version 2 of the Goddard Earth Observing System (GEOS-2) GCM forced with observed sea surface temperatures (SSTs). While much of the focus is on the seasonal time scale (January- March) and the Pacific North American (PNA) region, we also present results for other regions, shorter time scales, and other known modes of variability in the northern hemisphere extratropics. Forecasts of indices of some of the key large-scale modes of variability show that there is considerable variability in skill between different regions of the Northern Hemisphere. The eastern North Atlantic region has the poorest long lead forecast skill showing no skill beyond about 10 days. Skillful seasonal forecasts are primarily confined to the wave-like ENSO response emanating from the tropical Pacific. In the Northern Hemisphere, this is associated with the well-known Pacific/North American (PNA) pattern. Memory of the initial conditions is the major factor leading to skillful extratropical forecasts of lead time less than one month, while SST forcing is the only factor at the seasonal time scale. SST forcing contributes to skillful forecasts at sub- seasonal time scales only over the PNA region. The GEOS-2 GCM produces average (1980-94) signal to noise ratios which are less than one everywhere in the extratropics, except for the subtropical Pacific where they approach 1.5. When confined to the ENSO years, the maximum signal to noise ratios occur in the PNA region where they exceed three. An assessment of the sampling distribution of the forecasts suggests the model's ENSO response is very likely too weak. These results show some sensitivity to the uncertainties in the estimates of the SST forcing fields. In the North Pacific region, the sensitivity to SST forcing manifests itself primarily as changes in the variability of the PNA response, underscoring the need for an ensemble approach to the seasonal prediction problem.

Chang, Yehui↗

MODEL SELECTION FOR SPECTROPOLARIMETRIC INVERSIONS

Inferring magnetic and thermodynamic information from spectropolarimetric observations relies on the assumption of a parameterized model atmosphere whose parameters are tuned by comparison with observations. Often, the choice of the underlying atmospheric model is based on subjective reasons. In other cases, complex models are chosen based on objective reasons (for instance, the necessity to explain asymmetries in the Stokes profiles) but it is not clear what degree of complexity is needed. The lack of an objective way of comparing models has, sometimes, led to opposing views of the solar magnetism because the inferred physical scenarios are essentially different. We present the first quantitative model comparison based on the computation of the Bayesian evidence ratios for spectropolarimetric observations. Our results show that there is not a single model appropriate for all profiles simultaneously. Data with moderate signal-to-noise ratios (S/Ns) favor models without gradients along the line of sight. If the observations show clear circular and linear polarization signals above the noise level, models with gradients along the line are preferred. As a general rule, observations with large S/Ns favor more complex models. We demonstrate that the evidence ratios correlate well with simple proxies. Therefore, we propose to calculate these proxies when carrying out standard least-squares inversions to allow for model comparison in the future.

79 ASTRONOMY AND ASTROPHYSICS↗

Coherent summation of spatially distorted Doppler lidar signals using a two-dimensional heterodyne detector array

We have investigated the improvement in the signal-to-noise ratio for a coherent Doppler lidar through the use of a multi-element heterodyne detector array. Such an array enables the spatial summation of atmospheric refractive turbulence induced speckles, and time varying target speckles. Our recent experiments have shown that the non-coherent summation of the lidar signals from a heterodyne detector array can enhance the heterodyne mixing efficiency and thus the signal-to-noise ratio. In this paper, we expand this work to include the coherent summation of array signals. The digitized heterodyne signals were stored in a personal computer. Fast Fourier transforms were performed on both the non-coherent and coherent summations of the detector array signals. It was found that the coherent summation greatly enhanced the accuracy in the Doppler frequency estimate. A theoretical analysis was performed and indicated good agreement with experimental results. We have also applied these results to the more general lidar applications including atmospheric wind sensing, and have found that in most lidar applications the Doppler frequency estimate is increased through the use of the heterodyne detector array.

Chan, Kin Pui↗

Optical phase-locked loop (OPLL) for free-space laser communications with heterodyne detection

Several advantages of coherent free-space optical communications are outlined. Theoretical analysis is formulated for an OPLL disturbed by shot noise, modulation noise, and frequency noise consisting of a white component, a 1/f component, and a 1/f-squared component. Each of the noise components is characterized by its associated power spectral density. It is shown that the effect of modulation depends only on the ratio of loop bandwidth and data rate, and is negligible for an OPLL with loop bandwidth smaller than one fourth the data rate. Total phase error variance as a function of loop bandwidth is displayed for several values of carrier signal to noise ratio. Optimal loop bandwidth is also calculated as a function of carrier signal to noise ratio. An OPLL experiment is performed, where it is shown that the measured phase error variance closely matches the theoretical predictions.

Win, Moe Z.↗

Reverberation Mapping of Optical Emission Lines in Five Active Galaxies

We present the first results from an optical reverberation mapping campaign executed in 2014 targeting the active galactic nuclei (AGNs) MCG+08-11-011, NGC 2617, NGC 4051, 3C 382, and Mrk 374. Our targets have diverse and interesting observational properties, including a “changing look” AGN and a broad-line radio galaxy. Based on continuum-H β lags, we measure black hole masses for all five targets. We also obtain H γ and He ii λ 4686 lags for all objects except 3C 382. The He ii λ 4686 lags indicate radial stratification of the BLR, and the masses derived from different emission lines are in general agreement. The relative responsivities of these lines are also in qualitative agreement with photoionization models. These spectra have extremely high signal-to-noise ratios (100–300 per pixel) and there are excellent prospects for obtaining velocity-resolved reverberation signatures.

79 ASTRONOMY AND ASTROPHYSICS↗

Planck 2013 results. XIII. Galactic CO emission

Rotational transition lines of CO play a major role in molecular radio astronomy as a mass tracer and in particular in the study of star formation and Galactic structure. Although a wealth of data exists for the Galactic plane and some well-known molecular clouds, there is no available high sensitivity all-sky survey of CO emission to date. Such all-sky surveys can be constructed using the Planck HFI data because the three lowest CO rotational transition lines at 115, 230 and 345 GHz significantly contribute to the signal of the 100, 217 and 353 GHz HFI channels, respectively. Two different component separation methods are used to extract the CO maps from Planck HFI data. The maps obtained are then compared to one another and to existing external CO surveys. From these quality checks the best CO maps, in terms of signal to noise ratio and/or residual contamination by other emission, are selected. Three different sets of velocity-integrated CO emission maps are produced with different trade-offs between signal-to-noise, angular resolution, and reliability. Maps for the CO J = 1 → 0, J = 2 → 1, and J = 3 → 2 rotational transitions are presented and described in detail. They are shown to be fully compatible with previous surveys of parts of the Galactic plane as well as with under-sampled surveys of the high latitude sky. The Planck HFI velocity-integrated CO maps for the J = 1 → 0, J = 2 → 1, and J = 3 →2 rotational transitions provide an unprecedented all-sky CO view of the Galaxy. These maps are also of great interest to monitor potential CO contamination of the Planck studies of the cosmological microwave background.

79 ASTRONOMY AND ASTROPHYSICS↗

Planck 2013 results. XXX. Cosmic infrared background measurements and implications for star formation

We present new measurements of cosmic infrared background (CIB) anisotropies using Planck . Combining HFI data with IRAS, the angular auto-and cross-frequency power spectrum is measured from 143 to 3000 GHz, and the auto-bispectrum from 217 to 545 GHz. The total areas used to compute the CIB power spectrum and bispectrum are about 2240 and 4400 deg 2 , respectively. After careful removal of the contaminants (cosmic microwave background anisotropies, Galactic dust, and Sunyaev-Zeldovich emission), and a complete study of systematics, the CIB power spectrum is measured with unprecedented signal to noise ratio from angular multipoles ℓ ~ 150 to 2500. The bispectrum due to the clustering of dusty, star-forming galaxies is measured from ℓ ~ 130 to 1100, with a total signal to noise ratio of around 6, 19, and 29 at 217, 353, and 545 GHz, respectively. Two approaches are developed for modelling CIB power spectrum anisotropies. The first approach takes advantage of the unique measurements by Planck at large angular scales, and models only the linear part of the power spectrum, with a mean bias of dark matter haloes hosting dusty galaxies at a given redshift weighted by their contribution to the emissivities. The second approach is based on a model that associates star-forming galaxies with dark matter haloes and their subhaloes, using a parametrized relation between the dust-processed infrared luminosity and (sub-)halo mass. The two approaches simultaneously fit all auto-and cross-power spectra very well. We find that the star formation history is well constrained up to redshifts around 2, and agrees with recent estimates of the obscured star-formation density using Spitzer and Herschel . However, at higher redshift, the accuracy of the star formation history measurement is strongly degraded by the uncertainty in the spectral energy distribution of CIB galaxies. We also find that the mean halo mass which is most efficient at hosting star formation is log (M eff /M ⊙ ) = 12.6 and that CIB galaxies have warmer temperatures as redshift increases. The CIB bispectrum is steeper than that expected from the power spectrum, although well fitted by a power law; this gives some information about the contribution of massive haloes to the CIB bispectrum. Finally, we show that the same halo occupation distribution can fit all power spectra simultaneously. The precise measurements enabled by Planck pose new challenges for the modelling of CIB anisotropies, indicating the power of using CIB anisotropies to understand the process of galaxy formation.

79 ASTRONOMY AND ASTROPHYSICS↗

A dual high-energy radiography platform with 15 μ m resolution at the National Ignition Facility

To study matter at extreme densities and pressures, we need mega laser facilities such as the National Ignition Facility as well as creative methods to make observations during timescales of a billionth of a second. To facilitate this, we developed a platform and diagnostic to characterize a new point-projection radiography configuration using two micro-wires irradiated by a short pulse laser system that provides a large field of view with up to 3.6 ns separation between images. In this work, we used tungsten-carbide solid spheres as reference objects and inferred characteristics of the back-lighter source using a forward-fitting algorithm. The resolution of the system is inferred to be 15 μm (using 12.5 μm diameter wires). The bremsstrahlung temperature of the source is 70–300 keV, depending on laser energy and coupling efficiency. By adding the images recorded on multiple stacked image plates, the signal-to-noise of the system is nearly doubled. The imaging characterization technique described here can be adapted to most point-projection platforms where the resolution, spectral contrast, and signal-to-noise are important.

47 OTHER INSTRUMENTATION↗

Techniques and tactics used in determining the structure of the trimeric ebolavirus glycoprotein

Here, the techniques, tactics and strategies used to overcome a series of technical roadblocks in crystallization and phasing of the trimeric ebolavirus glycoprotein are described. The trimeric membrane-anchored ebolavirus envelope glycoprotein (GP) is responsible for viral attachment, fusion and entry. Knowledge of its structure is important both for understanding ebolavirus entry and for the development of medical interventions. Crystal structures of viral glycoproteins, especially those in their metastable prefusion oligomeric states, can be difficult to achieve given the challenges in production, purification, crystallization and diffraction that are inherent in the heavily glycosylated flexible nature of these types of proteins. The crystal structure of ebolavirus GP in its trimeric prefusion conformation in complex with a human antibody derived from a survivor of the 1995 Kikwit outbreak has now been determined [Lee et al. (2008 ▶), Nature (London), 454, 177–182]. Here, the techniques, tactics and strategies used to overcome a series of technical roadblocks in crystallization and phasing are described. Glycoproteins were produced in human embryonic kidney 293T cells, which allowed rapid screening of constructs and expression of protein in milligram quantities. Complexes of GP with an antibody fragment (Fab) promoted crystallization and a series of deglycosylation strategies, including sugar mutants, enzymatic deglycosylation, insect-cell expression and glycan anabolic pathway inhibitors, were attempted to improve the weakly diffracting glycoprotein crystals. The signal-to-noise ratio of the search model for molecular replacement was improved by determining the structure of the uncomplexed Fab. Phase combination with Fab model phases and a selenium anomalous signal, followed by NCS-averaged density modification, resulted in a clear interpretable electron-density map. Model building was assisted by the use of B-value-sharpened electron-density maps and the proper sequence register was confirmed by building alternate sequences using N-linked glycan sites as anchors and secondary-structural predictions.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

HIRIS performance study

The remote sensing system simulation is used to study a proposed sensor concept. An overview of the instrument and its parameters is presented, along with the model of the instrument as implemented in the simulation. Signal-to-noise levels of the instrument under a variety of system configurations are presented and discussed. Classification performance under these varying configurations is also shown, along with relationships between signal-to-noise ratios, feature selection, and classification performance.

Kerekes, John P.↗

Comparison of frequency domain and time domain laser velocimeter signal processors

An experimental investigation was conducted in the 14- by 22-foot subsonic tunnel at NASA-Langley Research Center to measure the inflow into a scale model helicopter rotor in forward flight. These inflow measurements were acquired utilizing a two-component laser velocimeter, and the data were processed by a frequency-domain processor (FDP). As a subset of the experiment, a time-domain counter processor was utilized simultaneously with an FDP to make a comparison of the two processors possible. The results indicate that the FDP had a marked improvement in processing capability in conditions of low signal-to-noise ratios and had a reduction in the number of erroneous data points acquired. However, the FDP yielded a lower data rate in comparison to the counter when signal-to-noise ratios were high. Comparison of the data sets shows that the FDP consistantly measures velocities which are 0.7 percent higher than those measured by the counter processor.

Mace, W. D., Jr.↗

Progress in Development of Improved Ion-Channel Biosensors

Further improvements have recently been made in the development of the devices described in Improved Ion-Channel Biosensors (NPO-30710), NASA Tech Briefs, Vol. 28, No. 10 (October 2004), page 30. As discussed in more detail in that article, these sensors offer advantages of greater stability, greater lifetime, and individual electrical addressability, relative to prior ion-channel biosensors. In order to give meaning to a brief description of the recent improvements, it is necessary to recapitulate a substantial portion of the text of the cited previous article. The figure depicts one sensor that incorporates the recent improvements, and can be helpful in understanding the recapitulated text, which follows: These sensors are microfabricated from silicon and other materials compatible with silicon. Typically, the sensors are fabricated in arrays in silicon wafers on glass plates. Each sensor in the array can be individually electrically addressed, without interference with its neighbors. Each sensor includes a well covered by a thin layer of silicon nitride, in which is made a pinhole for the formation of a lipid bilayer membrane. In one stage of fabrication, the lower half of the well is filled with agarose, which is allowed to harden. Then the upper half of the well is filled with a liquid electrolyte (which thereafter remains liquid) and a lipid bilayer is painted over the pinhole. The liquid contains a protein that forms an ion channel on top of the hardened agarose. The combination of enclosure in the well and support by the hardened agarose provides the stability needed to keep the membrane functional for times as long as days or even weeks. An electrode above the well, another electrode below the well, and all the materials between the electrodes together constitute a capacitor. What is measured is the capacitive transient current in response to an applied voltage pulse. One notable feature of this sensor, in comparison with prior such sensors, is a relatively thick dielectric layer between the top of the well and the top electrode. This layer greatly reduces the capacitance of an aperture across which the ion channels are formed, thereby increasing the signal-to-noise ratio. The use of a relatively large aperture with agarose support makes it possible to form many ion channels instead of only one, thereby further increasing the signal-to-noise ratio and effectively increasing the size of the available ionic reservoir. The relatively large reservoir makes it possible to measure AC rather than DC. This concludes the recapitulation from the cited previous article.

Nadeau, Jay L.↗

Innovative Compact Coronagraph Approach for Balloon-Borne Investigation of Temperature and Speed of Electrons in the Corona (BITSE)

We are developing an innovative compact coronagraph for studying the physical conditions in the solar wind acceleration region. This paper presents the new development of the compact coronagraph for the investigation of temperature and speed of electrons in the solar corona. The proposed compact coronagraph is a one stage externally occulted coronagraph without internal occulter or Lyot stop mask. The key of the new idea is to set the inner field cutoff at the External Occulter (EO) much smaller than the specified inner field cutoff. A second occulter on the surface of the detector array removes the remaining diffraction. The occulter on the detector surface functions similar to an internal occulter with the Inner Field of View Cutoff (IFoVC) exactly the same as specified. For BITSE, the desired inner field cutoff is 3 R, but the cutoff at EO is only 1.5 R☉. The diffraction analysis shows that in the sensor plane, the diffraction intensity at the 3 R☉ is not sensitive to the EO cutoff, either at 1.5 R☉ or close to 3 R☉. The advantage of having a smaller EO cutoff is that the vignetting decreased for the Field of View (FoV) near 3 R☉, therefore, the signal increases. Meanwhile, the diffraction of Point Spread Function is much less in the radial direction, which not only increases the image quality around 3 R☉, but also increases the encircled energy and signal to noise ratio. In other words, the data is useful right at 3 R☉! The BITSE optical design and diffraction analysis will be presented in detail. The simulation shows the signal to noise ratio obtained from the diffraction and vignetting data enables corona temperature and speed measurement.

Gong, Qian↗

Innovative Compact Coronagraph Approach for Balloon-Borne Investigation of Temperature and Speed of Electrons in the Corona (BITSE)

We are developing an innovative compact coronagraph for studying the physical conditions in the solar wind acceleration region. This paper presents the new development of the compact coronagraph for the investigation of temperature and speed of electrons in the solar corona. The proposed compact coronagraph is a one stage externally occulted coronagraph without internal occulter or Lyot stop mask. The key of the new idea is to set the inner field cutoff at the External Occulter (EO) much smaller than the specified inner field cutoff. A second occulter on the surface of the detector array removes the remaining diffraction. The occulter on the detector surface functions similar to an internal occulter with the Inner Field of View Cutoff (IFoVC) exactly the same as specified. For BITSE, the desired inner field cutoff is 3 R, but the cutoff at EO is only 1.5 R☉. The diffraction analysis shows that in the sensor plane, the diffraction intensity at the 3 R☉ is not sensitive to the EO cutoff, either at 1.5 R☉ or close to 3 R☉. The advantage of having a smaller EO cutoff is that the vignetting decreased for the Field of View (FoV) near 3 R☉, therefore, the signal increases. Meanwhile, the diffraction of Point Spread Function is much less in the radial direction, which not only increases the image quality around 3 R☉, but also increases the encircled energy and signal to noise ratio. In other words, the data is useful right at 3 R☉! The BITSE optical design and diffraction analysis will be presented in detail. The simulation shows the signal to noise ratio obtained from the diffraction and vignetting data enables corona temperature and speed measurement.

Gong, Qian↗

Dark Energy Survey Year 6 Results: Galaxy-galaxy lensing

We present galaxy--galaxy lensing (GGL) measurements from the full six years of data from the Dark Energy Survey (DES Y6), covering $4031\,\mathrm{deg}^2$ and used in the DES Y6 $3\times2$pt cosmological analysis. We use the MagLim++ lens sample, containing $\sim 9$ million galaxies divided into six redshift bins, and the Metadetection source catalog, including $\sim 140$ million galaxies divided into four redshift bins. The mean tangential shear signal achieves a total signal-to-noise ratio (S/N) of $173$, corresponding to a $17\%$ improvement over DES Y3. After applying the scale cuts used in the cosmological analysis, with $R_{\min}=6\,\mathrm{Mpc}/h$ ($4\,\mathrm{Mpc}/h$) for the linear (nonlinear) galaxy-bias model, the S/N is reduced to $75$ (90). A comprehensive suite of validation tests demonstrates that the measurement is robust against observational and astrophysical systematics at the statistical precision required for the DES Y6 analysis. Although not used in the main cosmological analysis, we extract high--signal-to-noise geometric shear-ratio measurements from the galaxy--galaxy lensing signal on small angular scales. These measurements provide an internal consistency check on the photometric redshift distributions and shear calibration used in the $3\times2$pt analysis.

Giannini, G. [Barcelona, IEEC; Chicago U., KICP; B↗