Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SAMPLING DEVICE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

Optical transmission modules for multi-channel superconducting quantum interference device readouts

We developed an optical transmission module consisting of 16-channel analog-to-digital converter (ADC), digital-noise filter, and one-line serial transmitter, which transferred Superconducting Quantum Interference Device (SQUID) readout data to a computer by a single optical cable. A 16-channel ADC sent out SQUID readouts data with 32-bit serial data of 8-bit channel and 24-bit voltage data at a sample rate of 1.5 kSample/s. A digital-noise filter suppressed digital noises generated by digital clocks to obtain SQUID modulation as large as possible. One-line serial transmitter reformed 32-bit serial data to the modulated data that contained data and clock, and sent them through a single optical cable. When the optical transmission modules were applied to 152-channel SQUID magnetoencephalography system, this system maintained a field noise level of 3 fT/√Hz @ 100 Hz.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Wide bandgap photoconductor (SiC:V)-based optically addressed light valve for high fluence operation

Optically addressable light valves based on wide bandgap 4H- and 6H-SiC as photoconductors were designed to withstand higher operational laser fluences than the state of-the-art bismuth silicon oxide (BSO; Bi 12 SiO 20 ) based devices. Vanadium-doped SiC was selected as the photoconductors due to their reasonable photoresponsivity while many fold improvement in laser induced damage threshold as compared to BSO. The laser induced damage threshold values of the materials were measured after exposing ~ 200 sites on the samples to increasing levels of fluence of a gaussian pulsed Nd: YAG laser system (1064 nm) with a 5 Hz repetition rate. The measured damage threshold values for BSO, 4H- and 6H-SiC were 0.4 J/cm 2 , 1.75 J/cm 2 and 1.8 J/cm 2 , respectively. Photoconductive switches based on 4H and 6H-SiC samples were characterized at wavelengths of 380 nm, 405 nm, and 447 nm. The peak photoresponsivity values of the 4H- and 6H-SiC materials were measured to be under 380 nm and 405 nm, respectively. The photoconductor was bonded to a BK7 optical window with 5 μm diameter microspheres as spacers. A twisted nematic type E7 liquid crystal (LC) was filled in the 5 μm gap in a vacuum chamber. The desired alignment of the liquid crystal was achieved by mutually orthogonal orientation of LC alignment layers on the two mating faces (SiC and BK7). The fabricated devices were modulated using address beams of wavelengths 380 nm, 405 nm, and 447 nm. In conclusion, required transmission levels of > 90% was achieved for the fabricated OALVs for a sinusoidal voltage waveform that meets the lifetime requirement of the device.

36 MATERIALS SCIENCE↗

First results of the silicon telescope using an 'artificial retina' for fast track finding

We present the first results of the prototype of a silicon tracker with trigger capabilities based on a novel approach for fast track finding. The working principle of the 'artificial retina' is inspired by the processing of visual images by the brain and it is based on extensive parallelization of data distribution and pattern recognition. The algorithm has been implemented in commercial FPGAs in three main logic modules: a switch for the routing of the detector hits, a pool of engines for the digital processing of the hits, and a block for the calculation of the track parameters. The architecture is fully pipelined and allows the reconstruction of real-time tracks with a latency less then 100 clock cycles, corresponding to 0.25 microsecond at 400 MHz clock. The silicon telescope consists of 8 layers of single-sided silicon strip detectors with 512 strips each. The detector size is about 10 cm x 10 cm and the strip pitch is 183 μm. The detectors are read out by the Beetle chip, a custom ASICs developed for LHCb, which provides the measurement of the hit position and pulse height of 128 channels. The 'artificial retina' algorithm has been implemented on custom data acquisition boards based on FPGAs Xilinx Kintex 7 lx160. The parameters of the tracks detected are finally transferred to host PC via USB 3.0. The boards manage the read-out ASICs and the sampling of the analog channels. The read-out is performed at 40 MHz on 4 channels for each ASIC that corresponds to a decoding of the telescope information at 1.1 MHz. We report on the first results of the fast tracking device and compare with simulations. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Transparent and Conductive Inorganic/Polymer‐Composite Encapsulants for Long‐Term Perovskite Solar Cells Operation

An innovative inorganic/polymer-composite encapsulation scheme comprising a polymer-based transparent conductive composite (TCC) coupled with a transparent conductive oxide is introduced to extend the lifetime of moisture-sensitive devices such as perovskite solar cells (PSC). The TCC comprises conductive silver-coated polymethyl methacrylate (Ag-PMMA) microsphere fillers protruding from a transparent non-conductive polymer matrix. TCC samples (5% Ag-PMMA by area) demonstrate high optical transparencies (%T approx. 85% in the 370–1200 nm region), low out-of-plane electrical resistivities (R < 0.2 Ω cm 2 ), and equilibrium permeabilities of less than 1 g mm/m 2 /day, all of which are well-maintained after 1,000 hours of environmental exposure. In practice, the TCC is employed between two indium zinc oxide (IZO) thin films, with the in-plane conductivity of IZO and the out-of-plane conductivity of TCC working collectively to function as a single encapsulating electrode. This encapsulation scheme is exemplified by benchmarking performances of PSCs subjected to accelerated aging conditions of quasi-maximum power point tracking under light soaking in air at 50 °C, 40% R.H. to 60% R.H. Notable improvements in operational lifetimes are observed, with a champion encapsulated PSC maintaining over 90% of its initial efficiency of 21.65% for up to 1,430 hours, compare to less than 300 hours for an unencapsulated control.

14 SOLAR ENERGY↗

Green Emitting Cerium Doped CaS Whiskers Grown by Solid State Diffusion Method

Undoped and cerium doped Calcium sulfide (CaS) phosphors were synthesized using solid state diffusion method. The X-ray diffraction pattern revealed that both undoped and doped CaS crystallites have cubic structure with average crystallite size varying from 20 to 30 nm. Scanning electron micrographs indicated that Ce doped CaS phosphors were composed of whiskers with different dimensions and orientations. The optical properties of undoped and Ce doped particles were characterized using Photoluminescence (PL) and UV-Vis absorption spectroscopy. The PL emission spectrum of cerium doped CaS phosphors for an excitation wavelength 465 nm showed a main peak at 500 nm and a shoulder peak at 556 nm due to 5d → 4f transition in Ce{sup 3+} ions. The variation of PL intensity with cerium concentration was investigated and the maximum PL intensity was obtained for a doping concentration of 3 wt.%. The optical band gap of the samples was estimated from the diffuse reflectance spectrum and was found to increase with increase in cerium concentration. The enhanced optical properties of these phosphors can be exploited in various optoelectronic devices including displays and bioimaging techniques.

36 MATERIALS SCIENCE↗

Effects of neutron irradiation on hydrogen isotope permeation on W-Re

Hydrogen and deuterium permeation behavior for neutron damaged W and W-3 %Re was evaluated using a Plasma Driven Permeation device. For neutron damaged W-3 %Re at 773 K and 1473 K, precipitation of Re and Os was observed by atom probe tomography. Neutron irradiation introduced defect damage throughout the sample and enhanced H and D diffusion toward downstream side. The existence of irradiation damage by neutron irradiation was found to increase hydrogen isotope permeation. Moreover, the existence of Re has suppressed the formation of irradiation defects for hydrogen isotope trapping sites. Further, the recovery of irradiation defects by increasing the irradiation temperature led to the structural changes due to the diffusion of Re and Os, which also affected the hydrogen isotope permeation behavior.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Deuterium retention in MeV ion-irradiated beryllium

Beryllium, as the material of choice for the ITER first wall, will be subject to high energy neutrons during the operation of the fusion device. Such irradiation will create displacement damage in the crystal lattice, which is known to influence hydrogen isotope retention, e.g. in iron and tungsten. Here in our study, we irradiated beryllium samples with high-energy oxygen ions up to various dpa levels (0.01 dpa, 0.1 dpa, and 1 dpa) and subsequently exposed the samples to deuterium plasma at 370 K and 573 K. The amount of retained deuterium was measured by thermal desorption spectroscopy and nuclear reaction analysis and was found to decrease by about 18% in the samples damaged up to 0.1 dpa compared to the undamaged ones. Further damaging up to 1 dpa did not show any additional effects on deuterium retention. Transmission electron microscopy was used to check for the existence of bubbles after plasma exposure.

36 MATERIALS SCIENCE↗

Sol-gel preparation and characterization of Er3+ doped TiO2 luminescent nanoparticles

Highlights: • Sol-gel derived Er{sup 3+} doped TiO{sub 2} nanoparticles for potential use in solar cells and bio imaging. • Influence of Er{sup 3+} doping into TiO{sub 2} with various Er{sup 3+} concentration on structural, optical, and luminescence properties. • Down-and up-conversion luminescence behaviour of Er{sup 3+} doped titanium dioxide. - Abstract: The present paper reports on down-and up-conversion luminescence behaviour of sol-gel derived erbium doped titanium dioxide with anatase structure. Through combined structural, optical and electron microscope analysis, effective and influence of Er{sup 3+} doping into TiO{sub 2} lattice has been demonstrated using X-Ray diffraction (XRD), scanning electron microscope (SEM), transmission electron microscope (TEM), and optical reflectance spectra. XRD results showed only anatase diffraction peaks of TiO{sub 2}, indicating the formation of a pure anatase phase even after Er{sup 3+} incorporation into TiO{sub 2} lattice. Selected Area Electron Diffraction (SAED) confirmed that the synthesized TiO{sub 2} nanoparticles are polycrystalline in nature which correlated well with XRD findings. Upon excitation at 320 nm, two down-conversion contributions at 378 nm and 435 nm attributed to indirect band gap and defect-related emissions, respectively were observed from both pure and Er{sup 3+} doped TiO{sub 2} nanoparticles. On the other hand, strong green up-conversion emission centred at 544 nm ascribed to {sup 4}S{sub 3/2 }→ {sup 4}I{sub 15/2} transition of Er{sup 3+} was observed under 980 nm laser excitation for all Er{sup 3+} doped TiO{sub 2} samples. This result analysis brings insight on understanding of structural, optical and luminescence properties of Er{sup 3+} doped TiO{sub 2} nanoparticles for use in solar cells and bio imaging devices.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

A Six-Membered Concerted Mechanism for CO 2 Capture by Amines Studied under Charged Microdroplet Reaction Conditions

Carbon dioxide (CO 2 ) capture and storage represents an important technological challenge. A mechanistic understanding of interactions involved in the capture process is necessary not only for technological development but also for efficient conversion of captured CO 2 into value-added materials. Herein, we present a novel contained secondary electrospray ionization platform for studying the interactions of gaseous amines and CO 2 gas under microdroplet reaction conditions, which enables mass spectrometry (MS) characterization of CO 2 capture products and intermediates in real time. We detected [2 M + CO 2 + H] + species, which corresponds to a six-membered intermediate. DFT calculations confirmed the high stability of the protonated six-membered ring intermediate. This finding provides a plausible concerted mechanism in the microdroplet environment that excludes the involvement of thermodynamically disfavored ionic species. The carbamic acid counterpart of the final product/salt was readily characterized by tandem MS. The carbamic acid/amine salt was also isolated and characterized by Fourier transform infrared spectroscopy. By virtue of the fact that headspace vapors of amines are sampled, we were able to establish a high-throughput platform that enabled the CO 2 capture capacity of five different amines to be studied in under 2 min. The same device also enabled the absolute quantification of capture capacity.

Amines↗

Effect of different sulphur precursors on morphology and band-gap on the formation of Cu{sub 2}ZnSnS{sub 4} (CZTS) particles with microwave irradiation

Cu{sub 2}ZnSnS{sub 4} (CZTS) is a promising semiconductor material for ecological cost effective thin film Photovoltaic (PV) devices. As it contains earth abundant and non-toxic elements, it has the advantages over commercially available CIGS and CdTe thin film PV devices. In the present work, the pure phase Cu{sub 2}ZnSnS{sub 4} particles were successfully synthesised with microwave irradiation. The morphology and phase study was carried out for the samples prepared with two different sulphur precursors viz. thiourea and thioacetamide (TAA). CZTS particles with thiourea as sulphur precursor are more crystalline than CZTS particles with TAA. The band gap of 1.654 eV and 1.713 eV were calculated for the samples prepared with thiourea and TAA respectively.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Wide-field microwave magnetic field imaging with nitrogen-vacancy centers in diamond

Non-invasive imaging of microwave (MW) magnetic fields with microscale lateral resolution is pivotal for various applications, such as MW technologies and integrated circuit failure analysis. Diamond nitrogen-vacancy (NV) center magnetometry has emerged as an ideal tool, offering micrometer-scale resolution, millimeter-scale field of view, high sensitivity, and non-invasive imaging compatible with diverse samples. However, up until now, it has been predominantly used for imaging of static or low-frequency magnetic fields or, concerning MW field imaging, to directly characterize the same microwave device used to drive the NV spin transitions. In this work, we leverage an NV center ensemble in diamond for wide-field imaging of MW magnetic fields generated by a test device employing a differential measurement protocol. The microscope is equipped with a MW loop to induce Rabi oscillations between NV spin states, and the MW field from the device-under-test is measured through local deviations in the Rabi frequency. This differential protocol yields magnetic field maps of a 2.57 GHz MW field with a sensitivity of ∼9 μT Hz −1/2 for a total measurement duration of T=357 s, covering a 340 × 340 μm 2 field of view with a micrometer-scale spatial resolution and a device-under-test input power dynamic range of 30 dB. This work demonstrates a novel NV magnetometry protocol, based on differential Rabi frequency measurement, that extends NV wide-field imaging capabilities to imaging of weak MW magnetic fields that would be difficult to measure directly through standard NV Rabi magnetometry.

crystallographic defects↗

Anisotropic thermal transport in bulk hexagonal boron nitride

Hexagonal boron nitride (h-BN) has received great interest in recent years as a wide band-gap analog of graphene-derived systems along with its potential in a wide range of applications, for example, as the dielectric layer for graphene devices. However, the thermal transport properties of h-BN, which can be critical for device reliability and functionality, are little studied both experimentally and theoretically. The primary challenge in the experimental measurements of the anisotropic thermal conductivity of h-BN is that typically the sample size of h-BN single crystals is too small for conventional measurement techniques, as state-of-the-art technologies synthesize h-BN single crystals with lateral sizes only up to 2.5 mm and thicknesses up to 200 μm. Recently developed time-domain thermoreflectance (TDTR) techniques are suitable to measure the anisotropic thermal conductivity of such small samples, as it only requires a small area of 50 × 50 μm 2 for the measurements. Accurate atomistic modeling of thermal transport in bulk h-BN is also challenging due to the highly anisotropic layered structure. Here we conduct an integrated experimental and theoretical study on the anisotropic thermal conductivity of bulk h-BN single crystals over the temperature range of 100–500 K using TDTR measurements with multiple modulation frequencies and a full-scale numerical calculation of the phonon Boltzmann transport equation starting from first principles. Our experimental and numerical results compare favorably for both the in-plane and the through-plane thermal conductivities. We observe unusual temperature dependence and phonon-isotope scattering in the through-plane thermal conductivity of h-BN and elucidate their origins. Here, this article not only provides an important benchmark of the anisotropic thermal conductivity of h-BN, but also develops fundamental insight into the nature of phonon transport in this highly anisotropic layered material.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

RIA simulation tests using driver tube for ATF cladding

Pellet-cladding mechanical interaction (PCMI) is a potential failure mechanism for accident-tolerant fuel (ATF) cladding candidates during a reactivity-initiated accident (RIA). This report summarizes Fiscal Year (FY) 2017 research activities that were undertaken to evaluate the PCMI-like hoop-strain-driven mechanical response of ATF cladding candidates. To achieve various RIA-like conditions, a modified-burst test (MBT) device was developed to produce different mechanical pulses. The calibration of the MBT instrument was accomplished by performing mechanical tests on unirradiated Generation-I iron-chromium-aluminum (FeCrAl) alloy samples. Shakedown tests were also conducted in both FY 2016 and FY 2017 using unirradiated hydrided ZIRLO™ tube samples. This milestone report focuses on testing of ATF materials, but the benchmark tests with hydrided ZIRLO™ tube samples are documented in a recent journal article.a For the calibration and benchmark tests, the hoop strain was monitored using strain gauges attached to the sample surface in the hoop direction. A novel digital image correlation (DIC) system composed of a single high-speed camera and an array of six mirrors was developed for the MBT instrument to better resolve the failure behavior of samples and to provide useful data for validation of high-fidelity modeling and simulation tools. The DIC system enable a 360° view of a sample’s outer surface. This feature was added to the instrument to determine the precise failure location on a sample’s surface for strain predictions. The DIC system was tested on several silicon carbide fiber/silicon carbide matrix (SiC/SiC) composite tube samples at various pressurization rates of the driver tube (which correspond to the strain rates for the samples). The hoop strains for various loading conditions were determined for the SiC/SiC composite tube samples. Future work is planned to enhance understanding of the failure behavior of the ATF cladding candidates of age-hardened FeCrAl alloys and SiC/SiC composites in detail during RIA conditions informed by the computational studies performed under the US Department of Energy Office of Nuclear Energy Advanced Fuels Campaign. The testing instrument and the new DIC system will be further developed to reach different stress-state conditions and to perform tests at elevated temperatures.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

CRADA Final Report: CRADA Number NFE-22-09330 with General Fusion

General Fusion is developing a magnetized target fusion (MTF) approach that involves compressing an initial magnetically confined plasma inside a cavity formed in liquid metal. This approach builds from concepts initially developed under the Linus program at the U.S. Naval Research Laboratory and combines it with advances from compact toroid experiment (CTX) and sustained spheromak plasma experiment (SSPX) in compact toroid plasmas and coaxial Marshall gun systems. Modeling the tokamak during compression is central to designing a successful MTF device. The plasma is formed by coaxial helicity injection in the General Fusion device. Immediately after formation, the plasma has a diverted tokamak configuration with a single null. As the wall moves inwards, the plasma is repelled from the conducting surface and driven inwards by currents induced by its magnetic field in the liquid metal wall. As the liquid metal closes (or bridges) the opening of the coaxial plasma injector, the magnetic field topology alters to remove the null. Due to this, the plasma moves from a diverted to a wall-limited configuration. The liquid metal liner continues to close in and change shape, reducing in radius by a factor of ten at the peak of plasma compression. A model of the MTF plasma must be able to handle this continually varying geometry, and to be predictive, it must faithfully include the real imperfections arising in the process. In this project, we pursued a Monte Carlo approach to closures for MHD by computing kinetic electron trajectories in an MHD plasma background from simulations of GF devices. This requires enhancing the capabilities of the KORC-T code for running large ensembles of kinetic trajectories by porting it to GPU architectures and enabling workflows for large ensembles on OLCF machines. With these capabilities, it is possible to produce a large library of kinetic calculations of electron orbits evolving in plasma configurations spanning the magnetic configurations and plasma density profiles, including non-axisymmetry, arising in the General Fusion’s existing PI3 spherical tokamak device. Using ensembles will capture particles passing a single point in space in a given magnetic configuration, and the entire dataset will cover a range of global magnetic field geometries. By sampling around many starting points, this dataset will capture the spatial dependence of the plasma parameters. From this large dataset, it is possible to produce a reduced model for the kinetic effects not captured in MHD.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

FAST (FAST AUTONOMOUS SCANNING TOOLKIT)

SF-23-006 FAST (FAST AUTONOMOUS SCANNING TOOLKIT)The software is deployed on an edge computing device at the beamline computer attached to a scanning microscope. It iteratively analyzes the data collected, then identifies new scan positions to scan next and directs the positioners that move the sample (or probe beam) to these positions. Overall, it identifies a sparse set of scan positions that are sufficient to image the full sample. This can reduce the scan time by >60%.

KANDEL, SAUGAT↗

Devices, systems, and methods for detecting nucleic acids using sedimentation

Embodiments of the present invention are directed toward devices, systems, and method for conducting nucleic acid purification and quantification using sedimentation. In one example, a method includes generating complexes which bind to a plurality of beads in a fluid sample, individual ones of the complexes comprising a nucleic acid molecule such as DNA or RNA and a labeling agent. The plurality of beads including the complexes may be transported through a density media, wherein the density media has a density lower than a density of the beads and higher than a density of the fluid sample, and wherein the transporting occurs, at least in part, by sedimentation. Signal may be detected from the labeling agents of the complexes.

47 OTHER INSTRUMENTATION↗

Devices, systems, and methods for detecting nucleic acids using sedimentation

Embodiments of the present invention are directed toward devices, systems, and method for conducting nucleic acid purification and quantification using sedimentation. In one example, a method includes generating complexes which bind to a plurality of beads in a fluid sample, individual ones of the complexes comprising a nucleic acid molecule such as DNA or RNA and a labeling agent. The plurality of beads including the complexes may be transported through a density media, wherein the density media has a density lower than a density of the beads and higher than a density of the fluid sample, and wherein the transporting occurs, at least in part, by sedimentation. Signal may be detected from the labeling agents of the complexes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Scanning SQUID susceptometers with sub-micron spatial resolution

Superconducting QUantum Interference Device (SQUID) microscopy has excellent magnetic field sensitivity, but suffers from modest spatial resolution when compared with other scanning probes. This spatial resolution is determined by both the size of the field sensitive area and the spacing between this area and the sample surface. In this paper we describe scanning SQUID susceptometers that achieve sub-micron spatial resolution while retaining a white noise floor flux sensitivity of ≈2μΦ{sub 0}/Hz{sup 1/2}. This high spatial resolution is accomplished by deep sub-micron feature sizes, well shielded pickup loops fabricated using a planarized process, and a deep etch step that minimizes the spacing between the sample surface and the SQUID pickup loop. We describe the design, modeling, fabrication, and testing of these sensors. Although sub-micron spatial resolution has been achieved previously in scanning SQUID sensors, our sensors not only achieve high spatial resolution but also have integrated modulation coils for flux feedback, integrated field coils for susceptibility measurements, and batch processing. They are therefore a generally applicable tool for imaging sample magnetization, currents, and susceptibilities with higher spatial resolution than previous susceptometers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗