Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SAMPLING DEVICE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

Initial Benchmarks of UV LEDs and Comparisons with White LEDs

The primary goal of this report is to benchmark the initial level of performance of a selection of commercial UV LEDs across all three bands (i.e., UV-A, UV-B, UV-C). To provide the initial performance benchmarks, a test matrix containing 13 different UV LED products was created in association with the LED Systems Reliability Consortium (LSRC). The products in this test matrix were all commercially available as of June 2021, and at least 22 samples of each product were tested. In addition, two common, commercial white LEDs were tested to provide a benchmark against blue-pumped white LEDs. Testing of the samples included electrical performance testing (e.g., current-voltage measurements) and photometric testing in a calibrated integrating sphere capable of measuring devices in the UV-A, UV-B, and UV-C bands. The electrical testing provided insights into the performance of the semiconductor layers in the LEDs, allowing parameters such as the threshold voltage (V th ) and serial resistance (R serial ) of each sample to be determined. The photometric testing provided insights into emission wavelengths, peak shapes, and radiant efficiencies for each sample. Combined, the information from these tests permits the overall device efficiencies to be compared and provides insights into the electrical and optical performance of the technology.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Addressing the Stability Gap in Photoelectrochemistry: Molybdenum Disulfide Protective Catalysts for Tandem III–V Unassisted Solar Water Splitting

While photoelectrochemical (PEC) solar-to-hydrogen efficiencies have greatly improved over the past few decades, advances in PEC durability have lagged behind. Corrosion of semiconductor photoabsorbers in the aqueous conditions needed for water splitting is a major challenge that limits device stability. In addition, a precious-metal catalyst is often required to efficiently promote water splitting. In this work, we demonstrate unassisted water splitting using a nonprecious metal molybdenum disulfide nanomaterial catalytic protection layer paired with a GaInAsP/GaAs tandem device. This device was able to achieve stable unassisted water splitting for nearly 12 h, while a sibling sample with a PtRu catalyst was only stable for 2 h, highlighting the advantage of the nonprecious metal catalyst. In situ optical imaging illustrates the progression of macroscopic degradation that causes device failure. Furthermore, this work compares unassisted water splitting devices across the field in terms of the efficiency and stability, illustrating the need for improved stability.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Three-terminal ferroelectric synapse device with concurrent learning function for artificial neural networks

Spike-timing-dependent synaptic plasticity (STDP) is demonstrated in a synapse device based on a ferroelectric-gate field-effect transistor (FeFET). STDP is a key of the learning functions observed in human brains, where the synaptic weight changes only depending on the spike timing of the pre- and post-neurons. The FeFET is composed of the stacked oxide materials with ZnO/Pr(Zr,Ti)O{sub 3} (PZT)/SrRuO{sub 3}. In the FeFET, the channel conductance can be altered depending on the density of electrons induced by the polarization of PZT film, which can be controlled by applying the gate voltage in a non-volatile manner. Applying a pulse gate voltage enables the multi-valued modulation of the conductance, which is expected to be caused by a change in PZT polarization. This variation depends on the height and the duration of the pulse gate voltage. Utilizing these characteristics, symmetric and asymmetric STDP learning functions are successfully implemented in the FeFET-based synapse device by applying the non-linear pulse gate voltage generated from a set of two pulses in a sampling circuit, in which the two pulses correspond to the spikes from the pre- and post-neurons. The three-terminal structure of the synapse device enables the concurrent learning, in which the weight update can be performed without canceling signal transmission among neurons, while the neural networks using the previously reported two-terminal synapse devices need to stop signal transmission for learning.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Structural phase transitions in SrTiO 3 nanoparticles

We present that pressure dependent structural measurements on monodispersed nanoscale SrTiO 3 samples with average diameters of 10 to ~80 nm were conducted to enhance the understanding of the structural phase diagram of nanoscale SrTiO 3 . A robust pressure independent polar structure was found in the 10 nm sample for pressures up to 13 GPa, while a size dependent cubic to tetragonal transition occurs (at P = P c ) for larger particle sizes. In conclusion, the results suggest that the growth of ~10 nm STO particles on substrates with significant lattice mismatch may maintain a polar state for a large range of strain values, possibly enabling device use.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Batch Gas-Sampling System

Sampler collects air or other gases in consistent way and stabilizes them for later chemical analysis. Device used for concentrations ranging from few parts per million to 100 percent. Also separates and collects particles in gas for analysis. Gas flows into vacuum sphere when solenoid valve opened. As it passes through conversion tube, constituent of gas forms stable compound that remains in conversion tube for analysis at later time. Sampler parts made of glass, polytetrafluoroethylene, and stainless steel so they do not react with sample.

Diaz, Vernon, Jr.↗

Layer-by-layer assembly of a [Fe-(pyrazine){Pd(CN) 4 }] spin crossover thin film

Abstract [Fe-(pyrazine){Pd(CN) 4 }] (pyrazine = pz) thin films were fabricated using a layer-by-layer assembly approach, a method known to be tunable, versatile, and scalable, since thin films are better-suited for industrial applications. In this study, [Fe-(pz){Pd(CN) 4 }] powder was synthesized, and the results obtained from a vibrating sample magnetometer verified the presence of an abrupt hysteresis loop with widths of 45 K centered around 300 K, indicating good cooperativity. Super conducting quantum interference device magnetometry results indicated a slow spin transition with temperature but with evidence of hysteresis for thin film samples. X-ray absorption analysis provided further support of the spin crossover behavior but differs from the magnetometry because the spin state transition at the surface differs from the bulk of the thin film. X-ray photoelectron spectroscopy provided some insight into issues with the film deposition process and multiplex fitting was used to further support the claim that the surface of the film is different than the bulk of the film.

McElveen, Kayleigh A. (ORCID:0000000210302913)↗

Identification of rhenium donors and sulfur vacancy acceptors in layered MoS{sub 2} bulk samples

MoS{sub 2} monolayers, a two-dimensional (2D) direct semiconductor material with an energy gap of 1.9 eV, offer many opportunities to be explored in different electronic devices. Defects often play dominant roles in the electronic and optical properties of semiconductor devices. However, little experimental information about intrinsic and extrinsic defects or impurities is available for this 2D system, and even for macroscopic 3D samples for which MoS{sub 2} shows an indirect bandgap of 1.3 eV. In this work, we evaluate the nature of impurities with unpaired spins using electron paramagnetic resonance (EPR) in different geological macroscopic samples. Regarding the fact that monolayers are mostly obtained from natural crystals, we expect that the majority of impurities found in macroscopic samples are also randomly present in MoS{sub 2} monolayers. By EPR at low temperatures, rhenium donors and sulfur vacancy acceptors are identified as the main impurities in bulk MoS{sub 2} with a corresponding donor concentration of about 10{sup 8–12} defects/cm{sup 2} for MoS{sub 2} monolayer. Electrical transport experiments as a function of temperature are in good agreement with the EPR results, revealing a shallow donor state with an ionization energy of 89 meV and a concentration of 7 × 10{sup 15 }cm{sup −3}, which we attribute to rhenium, as well as a second deeper donor state with ionization energy of 241 meV with high concentration of 2 × 10{sup 19 }cm{sup −3} and net acceptor concentration of 5 × 10{sup 18 }cm{sup −3} related to sulfur vacancies.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Lunar rock splitter/can sealer

A manually powered and operated force generating device fractures lunar material as received from the moon and seals cans containing lunar samples. The rock splitting and can sealing operations are carried out in a vacuum environment. Can sealing is a cold welding process that requires a pressure of 125,000 psi (generating 32,000 lb for the largest can used). The design and modification of the device and the operating experience are described.

Johnson, K. G.↗

Transport Powder and Liquid Samples by Surface Acoustic Waves

Sample transport is an important requirement for In-situ analysis of samples in NASA planetary exploration missions. Tests have shown that powders or liquid drops on a surface can be transported by surface acoustic waves (SAW) that are generated on the surface using interdigital transducers. The phenomena were investigated experimentally and to generate SAWs interdigital electrodes were deposited on wafers of 128 deg rotated Y-cut LiNbO?. Transporting capability of the SAW device was tested using particles of various sizes and drops of various viscosities liquids. Because of different interaction mechanisms with the SAWs, the powders and the liquid drops were observed to move in opposite directions. In the preliminary tests, a speed of 180 mm/s was achieved for powder transportation. The detailed experimental setup and results are presented in this paper. The transporting mechanism can potentially be applied to miniaturize sample analysis system or " lab-on-chip" devices.

Sample handling↗

Full data acquisition in Kelvin Probe Force Microscopy: Mapping dynamic electric phenomena in real space

Kelvin probe force microscopy (KPFM) has provided deep insights into the role local electronic, ionic and electrochemical processes play on the global functionality of materials and devices, even down to the atomic scale. Conventional KPFM utilizes heterodyne detection and bias feedback to measure the contact potential difference (CPD) between tip and sample. This measurement paradigm, however, permits only partial recovery of the information encoded in bias- and time-dependent electrostatic interactions between the tip and sample and effectively down-samples the cantilever response to a single measurement of CPD per pixel. This level of detail is insufficient for electroactive materials, devices, or solid-liquid interfaces, where non-linear dielectrics are present or spurious electrostatic events are possible. Here, we simulate and experimentally validate a novel approach for spatially resolved KPFM capable of a full information transfer of the dynamic electric processes occurring between tip and sample. General acquisition mode, or G-Mode, adopts a big data approach utilising high speed detection, compression, and storage of the raw cantilever deflection signal in its entirety at high sampling rates (> 4 MHz), providing a permanent record of the tip trajectory. We develop a range of methodologies for analysing the resultant large multidimensional datasets involving classical, physics-based and information-based approaches. Physics-based analysis of G-Mode KPFM data recovers the parabolic bias dependence of the electrostatic force for each cycle of the excitation voltage, leading to a multidimensional dataset containing spatial and temporal dependence of the CPD and capacitance channels. We use multivariate statistical methods to reduce data volume and separate the complex multidimensional data sets into statistically significant components that can then be mapped onto separate physical mechanisms. Overall, G-Mode KPFM offers a new paradigm to study dynamic electric phenomena in electroactive interfaces as well as offer a promising approach to extend KPFM to solid-liquid interfaces.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement Of Transverse Jc Profiles Of Coated Conductors Using A Magnetic Knife Of Permanent Magnets

The transverse J{sub c} distribution in YBCO coated conductors was measured nondestructively with high resolution using a 'magnetic knife' made of permanent magnets. The method utilizes the strong depression of J{sub c} in applied magnetic fields. A narrow region of low (including zero) magnetic field, in a surrounding higher field, is moved transversely across the sample in order to reveal the critical-current density distribution. The net resolution of this device is approximately 65 {mu}m, and the J{sub c} resolution is better than 0.5%. A Fourier series inversion process was used to determine the transverse J{sub c} distribution in the sample. The J{sub c} profile was correlated with other sample properties of coated conductors prepared by pulsed laser deposition. Because of its straight-forward and inexpensive design, this J{sub c} imaging technique can be a powerful tool for quality control in coated-conductor production.

36 MATERIALS SCIENCE↗

Measurement of transverse Jc profiles of coated conductors using a magnetic knife of permanent magnets

The transverse J{sub c} distribution in YBCO coated conductors was measured non-destructively with high resolution using a 'magnetic knife' made of permanent magnets. The method utilizes the strong depression of J{sub c} in applied magnetic fields. A narrow region of low (including zero) magnetic field, in a surrounding higher field, is moved transversely across the sample in order to reveal the critical-current density distribution. The net resolution of this device is approximately 65 {micro}m, and the J{sub c} resolution is better than 0.5%. A Fourier series inversion process was used to determine the transverse J{sub c} distribution in the sample. The J{sub c} profile was correlated with other sample properties of coated conductors prepared by pulsed laser deposition. Because of its straight-forward and inexpensive design, this J{sub c} imaging technique can be a powerful tool for quality control in coated-conductor production.

36 MATERIALS SCIENCE↗

Autonomous Measurement of Electrochemical Redox Couples for In-Situ Characterization of Enceladus Plume Samples

A 3D-printed microfluidic electrochemical cell with integrated electrodes was developed to demonstrate autonomous in-situ electrochemical characterization of terrestrial seawater samples. The system is designed to extend the capabilities of the 2008 Phoenix Lander’s Wet Chemistry Laboratory (WCL) that analyzed the soluble chemistry of the Martian soil, by miniaturizing its fluidic architecture for analysis of µL-volume samples as expected from an Enceladus fly-by mission. The microfluidic device has a total fluid volume of 48 µL and includes dual channels each populated with 7 electrodes. Measurement of pH was measured using an iridium oxide electrode. Cyclic voltammetry with Au, Pt, and glassy carbon working electrodes was used to measure redox couples in synthetic seawater that contained inorganic and bio-organic molecules. Glassy carbon was found to have minimal risk of interference from constituents of synthetic seawater when measuring molecular organic redox species; however, care must be used to prevent interference due to potential oxidation or dissolution in the case of Au working electrodes. A completely autonomous end-to-end run including sample delivery was performed, to demonstrate the feasibility of microfluidic-based cyclic voltammetry measurements for in-situ characterization of redox couples in Ocean World samples.

Planetary Instruments↗

Perpendicular magnetic anisotropy of Mn{sub 4}N films on MgO(001) and SrTiO{sub 3}(001) substrates

We grew Mn{sub 4}N epitaxial thin films capped with Au layers on MgO(001) and SrTiO{sub 3}(001) substrates by molecular beam epitaxy. Perpendicular magnetic anisotropy (PMA) was confirmed in all the samples at room temperature from the magnetization versus magnetic field curves using superconducting quantum interference device magnetometer. From the ω-2θ x-ray diffraction (XRD) and ϕ-2θ{sub χ} XRD patterns, the ratios of perpendicular lattice constant c to in-plane lattice constant a, c/a, were found to be about 0.99 for all the samples. These results imply that PMA is attributed to the in-plane tensile strain in the Mn{sub 4}N films.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A Holographic Prism Based on Photo-Thermo-Refractive Glass: Requirements and Possibilities

A technology for multivalued holographic measurement of a plane angle—a holographic prism, which serves as the basis for a device for calibrating the testing tools for navigational equipment under rolling— has been developed. The holographic prism is a miniature sample of photosensitive material, which contains a system of superimposed holographic gratings, and a laser the radiation of which passes through gratings to form a fan of diffracted beams. The fan in a prism based on a calcium fluoride (fluorite) crystal with color centers contained six out-of-plane beams radiating from a region with a hard-to-localize center. This fact hindered calibration of the measure and its application in the testing device. The use of photothermo-refractive glass as a material for preparing a sample and recording a system of holograms in it makes it possible to eliminate the drawbacks of fluorite-based prism. The number of holograms rises up to 21, the fan becomes in-plane, and its center is localized in a small region, with a size of several tenths of the sample thickness (1–2 mm). The fan beams are energetically homogeneous, and each can be identified when using the fan in a testing device.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Compact 'diode-based' multi-energy soft x-ray diagnostic for NSTX

A novel and compact, diode-based, multi-energy soft x-ray (ME-SXR) diagnostic has been developed for the National Spherical Tokamak Experiment. The new edge ME-SXR system tested on NSTX consists of a set of vertically stacked diode arrays, each viewing the plasma tangentially through independent pinholes and filters providing an overlapping view of the plasma midplane which allows simultaneous SXR measurements with coarse sub-sampling of the x-ray spectrum. Using computed x-ray spectral emission data, combinations of filters can provide fast (>10 kHz) measurements of changes in the electron temperature and density profiles providing a method to 'fill-in' the gaps of the multi-point Thomson scattering system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Use of a hexapod in diffraction measurements of substrate supported crystals of organic semiconductors

Thin films of organic semiconductor prepared on substrates generally contain crystals that have one common crystal plane parallel to the substrate but random in-plane orientations. In diffraction measurements of these structures, it is often required to anchor the X-ray beam on a fixed spot on the sample, such as an optically visible crystallite or island. Here, a hexapod is used in place of a traditional multi-circle diffractometer to perform area-detector-based diffraction measurements on an actual device that contains 6,13-bis(triisopropylsilyethynyl)-pentacene (TIPS-pentacene) crystals. The hexapod allows for sample rotations about any user-defined rotation center. Two types of complex sample motions have been programmed to characterize the structure of the TIPS-pentacene crystal: an in-plane powder average has been performed at a fixed grazing-incident angle to determine the lattice parameters of the crystal; then the in-plane component of the scattering vector was continuously rotated in transmission geometry to determine the local crystal orientation.

47 OTHER INSTRUMENTATION↗

Supervised Gamma Process Poisson Factorization

This thesis develops the supervised gamma process Poisson factorization (S- GPPF) framework, a novel supervised topic model for joint modeling of count matrices and document labels. S-GPPF is fully generative and nonparametric: document labels and count matrices are modeled under a uni ed probabilistic framework and the number of latent topics is controlled automatically via a gamma process prior. The framework provides for multi-class classification of documents using a generative max-margin classifier. Several recent data augmentation techniques are leveraged to provide for exact inference using a Gibbs sampling scheme. The first portion of this thesis reviews supervised topic modeling and several key mathematical devices used in the formulation of S-GPPF. The thesis then introduces the S-GPPF generative model and derives the conditional posterior distributions of the latent variables for posterior inference via Gibbs sampling. The S-GPPF is shown to exhibit state-of-the-art performance for joint topic modeling and document classification on a dataset of conference abstracts, beating out competing supervised topic models. The unique properties of S-GPPF along with its competitive performance make it a novel contribution to supervised topic modeling.

97 MATHEMATICS AND COMPUTING↗