Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Robotics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

Concrete material science: Past, present, and future innovations

Concrete is flying off, but it is simultaneously facing tremendous challenges in terms of environmental impact, financial needs, societal acceptance and image. Based on an historical approach of the science of concrete and reinforced concrete in particular, this paper calls for the exploration of radical changes in three key aspects of concrete use: reinforcement, binder content, and implementation methods. More precisely, it is suggested that, in parallel to the introduction of robotic fabrication methods, digital technologies may be key for the introduction several innovations like (i) rebar-free reinforcement using non-convex granular media; (ii) compression-optimized concrete structures, using topology optimization, architectural geometry, and 3D-printing or origami-patterned formworks; (iii) truly digital concrete through the coupling of massive data collection and deep learning.

36 MATERIALS SCIENCE↗

An optimization-based approach to tailor the mechanical response of soft metamaterials undergoing rate-dependent instabilities

An optimization-based design framework is proposed to tune the response of soft metamaterials involving both geometric instabilities and nonlinear viscoelastic material behavior. Designing the response of soft metamaterials to harness instabilities and undergo large, tailored configuration changes will enable advancements in soft robotics, shock and vibration mitigation, and flexible electronics. In line with the metamaterial concept, the response of these materials is governed to a large extent by the geometric and topological makeup of their small-scale features. However, the link between structure and response is less intuitive for soft metamaterials due to their reliance upon highly nonlinear responses triggered by geometric instabilities. This is further complicated by the effects of viscoelastic relaxation, which recent studies have shown to alter the emergence of instabilities in non-intuitive ways. Here, these effects are accounted for in our framework to achieve various design objectives, including tailored force–displacement response and maximized energy absorption from both geometric and material effects. To fully automate this process, it is essential to have a completely robust equation solver for forward problems involving instabilities and viscoelastic relaxation. We achieve this by casting the search for stable mechanical equilibrium — i.e. the forward problem — as a minimization problem and utilize a trust region algorithm to robustly handle instabilities and follow energetically-favorable equilibrium paths through critical points.

97 MATHEMATICS AND COMPUTING↗

Physically constrained 3D diffusion for inverse design of fiber-reinforced polymer composite materials

Designing fiber-reinforced polymer composites (FRPCs) with a tailored nonlinear stress-strain response is crucial for applications such as energy absorption in crash structures, flexible robotics, and impact-resistant protective gear. However, the inherent complexities of composite materials and the multitude of parameters involved, render traditional design and optimization methods inadequate for achieving effective inverse design of composites. In this paper, we present an AI-based inverse design framework that effectively and efficiently generates FRPCs with targeted nonlinear stress-strain responses. We introduce a physically constrained diffusion model (PC3D_Diffusion) capable of managing the complexities of composite materials and producing detailed, high-quality designs. We propose a loss-guided, learning-free approach to generate physically feasible microstructure designs by explicitly enforcing physical constraints during the generation process. For training purposes, 1.35 million FRPC samples were created, and their corresponding stress-strain curves were computed using established physics-based computational models. The results show that PC3D_Diffusion consistently generates high-quality designs with tailored mechanical behaviors, while guaranteeing compliance with the physical constraints. PC3D_Diffusion advances FRPC inverse design and may facilitate the inverse design of other 3D materials, offering potential applications in industries reliant on materials with custom mechanical properties.

Xu, Pei [Clemson Univ., SC (United States)]↗

Smart material based multilayered microbeam structures for spatial self-deployment and reconfiguration: A residual stress approach

Alleviation of the potentially damaging effects induced by residual stresses was comprehensively investigated in previous research. Here, this paper, however, presents a spatially self-deployable and reconfigurable multilayered microbeam which takes advantage of residual stresses and shape memory effects. Reconfigurable mechanism of a typical four-layered microbeam composed of Pt\Ni 50 Ti 50 \Ni 50 Ti 50 \Pt is introduced, followed by analytical modeling of the maximum distance of the self-deployed gap as functions of variable structural and material parameters, including compressive residual stress in Pt layers and tensile residual stress in Ni 50 Ti 50 layers. Analytical solutions given by the static model agree well with the results obtained via finite element models (FEMs). Fabrication, characterization, and in-situ experiments were carried out to validate the feasibility of deployment of the as-released four-layered microbeam. The maximum distance of the gap was measured to be 41.39 μm at 20 °C, which could be increased to 51.73 μm thanks to controllable reconfiguration driven by shape memory effects. Theoretical analysis of such self-deployment and reconfiguration suggested a tensile residual stress increase by 52 MPa in Ni 50 Ti 50 layers. The multilayered microbeam structure with capabilities of self-deployment and reconfiguration offers great potential for various emerging applications, such as micro robotics, medical drug delivery devices, and intelligent chip scale spacecraft.

36 MATERIALS SCIENCE↗

Nanoparticles caged with DNA nanostructures

Nanoparticles (NPs) offer many benefits in biotechnology because of their small size and unique properties. Furthermore, many applications require precise positioning of the NPs or biological targeting molecules on their surfaces. DNA cages constructed from DNA tile, origami, or wireframe nanostructures offer a promising path forward because of their simplicity and programmability that can be used to generate complex, dynamic 2D and 3D geometries. Such materials can be used to pattern DNA on NP surfaces and organize NPs into specific supramolecular structures. DNA-caged NPs can be implemented in biosensing and drug delivery applications with cavities precisely designed to encapsulate-specific biomolecules. Ultimately, such approaches provide a springboard for future DNA robot designs that will enable controlled interactions with biological systems.

59 BASIC BIOLOGICAL SCIENCES↗

Advancing specialized biofoundries via automated adaptive laboratory evolution

Adaptive laboratory evolution (ALE) is a powerful strategy for improving microbial phenotypes by harnessing natural selection under defined environmental conditions. Through applying selection regimes, beneficial mutations accumulate, enabling the generation of strains with enhanced properties. However, conventional ALE is labor-intensive and difficult to scale, limiting reproducibility and broader discovery of evolutionary principles. Recent advances in robotics, automation, and computational infrastructure are transforming ALE into a scalable, data-rich experimental paradigm. Automated platforms enable standardized and complex protocols, real-time monitoring, and highly parallel evolution campaigns, improving consistency while generating longitudinal datasets that reveal convergent adaptive mechanisms. Here, we discuss the role of specialized biofoundries in advancing automated ALE and enabling large-scale evolutionary engineering. We review major automated ALE formats and outline key design principles for effective ALE biofoundries, highlighting how automated ALE can support autonomous experimentation and AI-guided strain engineering.

59 BASIC BIOLOGICAL SCIENCES↗

Machine learning in nuclear materials research

Nuclear materials are often demanded to function for extended time in extreme environments, including high radiation fluxes with associated transmutations, high temperature and temperature gradients, mechanical stresses, and corrosive coolants. They also have a wide range of microstructural and chemical makeups, resulting in multifaceted and often out-of-equilibrium interactions. Machine learning (ML) is increasingly being used to tackle these complex time-dependent interactions and aid researchers in developing models and making predictions, sometimes with better accuracy than traditional modeling that focuses on one or two parameters at a time. Conventional practices of acquiring new experimental data in nuclear materials research are often slow and expensive, limiting the opportunity for data-centric ML, but new methods are changing that paradigm. Here we review high-throughput computational and experimental data approaches, especially robotic experimentation and active learning that is based on Gaussian process and Bayesian optimization. We show ML examples in structural materials (e.g., reactor pressure vessel (RPV) alloys and radiation detecting scintillating materials) and highlight new techniques of high-throughput sample preparation and characterizations, and automated radiation/environmental exposures and real-time online diagnostics. Herein, this review suggests that ML models of material constitutive relations in plasticity, damage, and even electronic and optical responses to radiation are likely to become powerful tools as they develop. Finally, we speculate on how the recent trends of using natural language processing (NLP) to aid the collection and analysis of literature data, interpretable artificial intelligence (AI), and the use of streamlined scripting, database, workflow management, and cloud computing platforms that will soon make the utilization of ML techniques as commonplace as the spreadsheet curve-fitting practices of today.

36 MATERIALS SCIENCE↗

From observation to replication: machine-learning-driven quantification and replication of fine-scale fish kinematics and behavior

Long-term quantification of fish behavior is essential for aquatic ecology, wildlife telemetry, and biomechanical device development. However, the observation duration required to obtain reliable behavioral and kinematic metrics remains unclear, and few tools exist to physically reproduce natural swimming motion for controlled experimentation. We address these challenges by developing a generalizable framework that models behavioral reliability (Spearman–Brown reliability index) as a function of observation duration and derives metric-specific monitoring thresholds. Using juvenile white sturgeon (Acipenser transmontanus) as a case study, we demonstrate that the minimum duration needed for reliable estimates varies substantially across kinematic features: to exceed a reliability of 0.8, total distance traveled requires 12 days, average curvature (mm?¹) 15 days, tail-beat frequency (Hz) 8 days, and average speed (body length/s) 17 days. We further bridge digital analysis and physical testing by developing a hardware-in-the-loop simulator that reconstructs machine-learning-derived swimming kinematics with high fidelity (correlation coefficient 0.98–0.99, RMSE 1.22–1.27 mm over a 5-minute segment). This platform enables realistic, repeatable motion stimuli for evaluating aquatic sensing technologies and bio-integrated devices under controlled conditions. Together, these contributions provide a scalable approach for designing long-term behavioral studies and a data-driven connection between ecological observation and robotic experimentation.

Hwang, SungJoo↗

Reinforcement learning building control approach harnessing imitation learning

Reinforcement learning (RL) has shown significant success in sequential decision making in fields like autonomous vehicles, robotics, marketing and gaming industries. This success has attracted the attention to the RL control approach for building energy systems which are becoming complicated due to the need to optimize for multiple, potentially conflicting, goals like occupant comfort, energy use and grid interactivity. However, for real world applications, RL has several drawbacks like requiring large training data and time, and unstable control behavior during the early exploration process making it infeasible for an application directly to building control tasks. To address these issues, an imitation learning approach is utilized herein where the RL agents starts with a policy transferred from accepted rule based policies and heuristic policies. This approach is successful in reducing the training time, preventing the unstable early exploration behavior and improving upon an accepted rule-based policy - all of these make RL a more practical control approach for real world applications in the domain of building controls.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Inverse reinforcement learning control for building energy management

Reinforcement learning (RL) based control is widely considered a promising approach in building automation and control as it has demonstrated the potential to deal with complex objectives in adjacent domains like robotics, autonomous vehicles, gaming applications, and advertisement recommendations. When applied to any environment, model-free RL learns to improve its control performance over time without requiring a control model, by receiving and then analyzing feedback from the building environment after each control action. Operational objectives are becoming increasingly complex through the simultaneous consideration of thermal comfort, carbon emissions, grid services, and indoor air quality. In this context, conventional rule-based control approaches are proving sub-optimal, mostly heuristic, and inadequate. The model-free and self learning nature of RL appears promising and attractive as it may address the scalability issues associated with advanced control approaches. However, it suffers from long training times and unstable control behavior during the early stages of its learning process, which makes it unsuitable to be applied directly to buildings. This paper addresses these issues using an inverse reinforcement learning approach (IRL), a technique utilized to learn the objective of a controller agent which is considered an expert in its respective domain. Here, we consider a rule-based control as the expert demonstrator. IRL is different from a direct imitation (i.e., direct mapping of states to actions) of control actions as it tries to find the underlying intent of an expert's policy, providing the controller with a better-generalized policy for unseen states or environments with slightly different dynamics. This approach propels the RL controller's policy to levels similar to or better than that of a rule-based policy before it starts learning by interacting with the building. This makes RL for building energy management applications more practical as it prevents the erratic and exploratory behavior in the initial training period, simultaneously speeding up the learning process when compared to applying an untrained RL agent directly to a building environment.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development towards stable chlorine isotope measurements of astromaterials using the modified Middleton source of an accelerator mass spectrometer

The volatile element Cl can be lost during the formation and evolution of planetary bodies, leading to fractionation of its two stable isotopes 35 Cl and 37 Cl. Chlorine isotope variations (reported as δ 37 Cl in parts per thousand (‰) relative to Standard Mean Ocean Chloride, SMOC) are documented to exceed 80‰ between different lunar rock samples and have been variably interpreted as the fingerprint of degassing during accretion, magma ocean, or volcanic portions of lunar history. The large intersample and intrasample variations observed by both bulk isotope ratio mass spectrometry (IRMS) and in-situ secondary ion mass spectrometry (SIMS) methods are difficult to interpret in part because of a paucity of bulk Cl isotope measurements. This lack of high-precision bulk data is due to the relative rarity of IRMS laboratories capable of making these high precision measurements on small samples of precious planetary materials such as those returned by human or robotic exploration. Here we present a new method for performing high precision δ 37 Cl measurements using the modified Middleton ion source of an existing accelerator mass spectrometer. For samples with as little as 1 μg Cl–the equivalent of 2–4 mm 3 of a typical lunar rock sample–the average cathode accuracy is ~1‰. Finally, cathode reproducibility is typically ~1‰ (2σ) for samples with at least 10 μg of Cl, increasing to ~3–6‰ for aliquots with ~1–2 μg Cl, similar to published SIMS results and sufficient to study astromaterials from the Moon, Mars, or 4 Vesta, which have tens of ‰ observed variations.

07 ISOTOPE AND RADIATION SOURCES↗

A Study on Target Positioning Error and Its Impact on Dose Variation in Image-Guided Stereotactic Body Radiotherapy for the Spine

Purpose: To investigate the amount of target positioning error and evaluate its dosimetric impact during image-guided stereotactic body radiotherapy for single-fraction spine treatment. Methods and Materials: A prescription dose of 15 Gy and five to nine coplanar intensity-modulated beams were used. The patient was immobilized with a custom-fit vacuum mold, and the target was localized with a volumetric cone-beam CT image. A robotic couch with six degrees of freedom was used for target adjustment. For evaluation a cone-beam CT image was obtained at the end of treatment. Both target positioning error and its dosimetric impact were investigated for the first 9 cases. Results: For cases studied, translational errors were 0.9 {+-} 0.5 mm (lateral), 1.2 {+-} 0.9 mm (longitudinal), 0.7 {+-} 0.6 mm (vertical), and 1.8 {+-} 1.0 mm (vector), and rotational errors were 1.6 deg. {+-} 1.3 deg. (pitch), 0.8 deg. {+-} 0.9 deg. (roll), and 0.8 deg. {+-} 0.4{sup o} (yaw). For the clinical target volume, D{sub 95} (dose to 95% of target volume), D{sub 90}, D{sub max}, and D{sub mean} were evaluated. Only 1 case showed significant dose variations, reaching up to 18% in D{sub 95}. The spinal cord dose was evaluated by observing D{sub 0.1} (dose to 0.1 cm{sup 3}), D{sub 0.5}, D{sub 1.0}, and D{sub max}. Although 1 case showed a dose change reaching up to 30% in D{sub max}, cord dose was within the planning tolerance limit in all but 2 cases (3% higher in one and 0.4% higher in the other). Conclusion: The implemented image-guided stereotactic body radiotherapy provides precise target localization. However, despite reasonably precise spatial precision, dosimetric perturbation can be significant because of both extremely steep dose gradients and close distances between the target and the spinal cord.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Stereotactic Body Radiotherapy and Gemcitabine for Locally Advanced Pancreatic Cancer

Purpose: Patients with nonmetastatic locally advanced unresectable pancreatic cancer have a dismal prognosis. Conventional concurrent chemoradiotherapy requires 6 weeks of daily treatment and can be arduous. We explored the safety and effectiveness of a 3-day course of hypofractionated stereotactic body radiotherapy (SBRT) followed by gemcitabine in this population. Patients and Methods: A total of 36 patients with nonmetastatic, locally advanced, unresectable pancreatic cancer with {>=}12 months of follow-up were included. They received three fractions of 8, 10, or 12 Gy (total dose, 24-36 Gy) of SBRT according to the tumor location in relation to the stomach and duodenum, using fiducial-based respiratory motion tracking on a robotic radiosurgery system. The patients were then offered gemcitabine for 6 months or until tolerance or disease progression. Results: With an overall median follow-up of 24 months (range, 12-33), the local control rate was 78%, the median overall survival time was 14.3 months, the median carbohydrate antigen 19-9-determined progression-free survival time was 7.9 months, and the median computed tomography-determined progression-free survival time was 9.6 months. Of the 36 patients, 28 (78%) eventually developed distant metastases. Six patients (17%) were free of progression at the last follow-up visit (range, 13-30 months) as determined by normalized tumor markers with stable computed tomography findings. Nine Grade 2 (25%) and five Grade 3 (14%) toxicities attributable to SBRT occurred. Conclusion: Hypofractionated SBRT can be delivered quickly and effectively in patients with nonmetastatic, locally advanced, unresectable pancreatic cancer with acceptable side effects and minimal interference with gemcitabine chemotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Setup Accuracy of the Novalis ExacTrac 6DOF System for Frameless Radiosurgery

Purpose: Stereotactic radiosurgery using frame-based positioning is a well-established technique for the treatment of benign and malignant lesions. By contrast, a new trend toward frameless systems using image-guided positioning techniques is gaining mainstream acceptance. This study was designed to measure the detection and positioning accuracy of the ExacTrac/Novalis Body (ET/NB) for rotations and to compare the accuracy of the frameless with the frame-based radiosurgery technique. Methods and Materials: A program was developed in house to rotate reference computed tomography images. The angles measured by the system were compared with the known rotations. The accuracy of ET/NB was evaluated with a head phantom with seven lead beads inserted, mounted on a treatment couch equipped with a robotic tilt module, and was measured with a digital water level and portal films. Multiple hidden target tests (HTT) were performed to measure the overall accuracy of the different positioning techniques for radiosurgery (i.e., frameless and frame-based with relocatable mask or invasive ring, respectively). Results: The ET/NB system can detect rotational setup errors with an average accuracy of 0.09 Degree-Sign (standard deviation [SD] 0.06 Degree-Sign ), 0.02 Degree-Sign (SD 0.07 Degree-Sign ), and 0.06 Degree-Sign (SD 0.14 Degree-Sign ) for longitudinal, lateral, and vertical rotations, respectively. The average positioning accuracy was 0.06 Degree-Sign (SD 0.04 Degree-Sign ), 0.08 Degree-Sign (SD 0.06 Degree-Sign ), and 0.08 Degree-Sign (SD 0.07 Degree-Sign ) for longitudinal, lateral and vertical rotations, respectively. The results of the HTT showed an overall three-dimensional accuracy of 0.76 mm (SD 0.46 mm) for the frameless technique, 0.87 mm (SD 0.44 mm) for the relocatable mask, and 1.19 mm (SD 0.45 mm) for the frame-based technique. Conclusions: The study showed high detection accuracy and a subdegree positioning accuracy. On the basis of phantom studies, the frameless technique showed comparable accuracy to the frame-based approach.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Online Image-based Monitoring of Soft-tissue Displacements for Radiation Therapy of the Prostate

Purpose: Emerging prolonged, hypofractionated radiotherapy regimens rely on high-dose conformality to minimize toxicity and thus can benefit from image guidance systems that continuously monitor target position during beam delivery. To address this need we previously developed, as a potential add-on device for existing linear accelerators, a novel telerobotic ultrasound system capable of real-time, soft-tissue imaging. Expanding on this capability, the aim of this work was to develop and characterize an image-based technique for real-time detection of prostate displacements. Methods and Materials: Image processing techniques were implemented on spatially localized ultrasound images to generate two parameters representing prostate displacements in real time. In a phantom and five volunteers, soft-tissue targets were continuously imaged with a customized robotic manipulator while recording the two tissue displacement parameters (TDPs). Variations of the TDPs in the absence of tissue displacements were evaluated, as was the sensitivity of the TDPs to prostate translations and rotations. Robustness of the approach to probe force was also investigated. Results: With 95% confidence, the proposed method detected in vivo prostate displacements before they exceeded 2.3, 2.5, and 2.8 mm in anteroposterior, superoinferior, and mediolateral directions. Prostate pitch was detected before exceeding 4.7 Degree-Sign at 95% confidence. Total system time lag averaged 173 ms, mostly limited by ultrasound acquisition rate. False positives (FPs) (FP) in the absence of displacements did not exceed 1.5 FP events per 10 min of continuous in vivo imaging time. Conclusions: The feasibility of using telerobotic ultrasound for real-time, soft-tissue-based monitoring of target displacements was confirmed in vivo. Such monitoring has the potential to detect small clinically relevant intrafractional variations of the prostate position during beam delivery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Sentinel Lymph Node Dissection to Select Clinically Node-negative Prostate Cancer Patients for Pelvic Radiation Therapy: Effect on Biochemical Recurrence and Systemic Progression

Purpose: To assess the efficacy of robotic-assisted laparoscopic sentinel lymph node (SLN) dissection (SLND) to select those patients with prostate cancer (PCa) who would benefit from additional pelvic external beam radiation therapy and long-term androgen deprivation therapy (ADT). Methods and Materials: Radioisotope-guided SLND was performed in 224 clinically node-negative patients scheduled to undergo external beam radiation therapy. Patients with histologically positive SLNs (pN1) were also offered radiation therapy to the pelvic lymph nodes, combined with 3 years of ADT. Biochemical recurrence (BCR), overall survival, and metastasis-free (including pelvic and nonregional lymph nodes) survival (MFS) rates were retrospectively calculated. The Briganti and Kattan nomogram predictions were compared with the observed pN status and BCR. Results: The median prostate-specific antigen (PSA) value was 15.4 ng/mL (interquartile range [IQR] 8-29). A total number of 834 SLNs (median 3 per patient; IQR 2-5) were removed. Nodal metastases were diagnosed in 42% of the patients, with 150 SLNs affected (median 1; IQR 1-2). The 5-year BCR-free and MFS rates for pN0 patients were 67.9% and 87.8%, respectively. The corresponding values for pN1 patients were 43% and 66.6%. The PSA level and number of removed SLNs were independent predictors of BCR and MFS, and pN status was an additional independent predictor of BCR. The 5-year overall survival rate was 97.6% and correlated only with pN status. The predictive accuracy of the Briganti nomogram was 0.665. Patients in the higher quartiles of Kattan nomogram prediction of BCR had better than expected outcomes. The complication rate from SLND was 8.9%. Conclusions: For radioisotope-guided SLND, the high staging accuracy is accompanied by low morbidity. The better than expected outcomes observed in the lower quartiles of BCR prediction suggest a role for SLN biopsy as a potential selection tool for the addition of pelvic radiation therapy and ADT intensification in pN1 patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Preliminary Results of a Phase 1 Dose-Escalation Trial for Early-Stage Breast Cancer Using 5-Fraction Stereotactic Body Radiation Therapy for Partial-Breast Irradiation

Purpose: To evaluate the tolerability of a dose-escalated 5-fraction stereotactic body radiation therapy for partial-breast irradiation (S-PBI) in treating early-stage breast cancer after partial mastectomy; the primary objective was to escalate dose utilizing a robotic stereotactic radiation system treating the lumpectomy cavity without exceeding the maximum tolerated dose. Methods and Materials: Eligible patients included those with ductal carcinoma in situ or invasive nonlobular epithelial histologies and stage 0, I, or II, with tumor size <3 cm. Patients and physicians completed baseline and subsequent cosmesis outcome questionnaires. Starting dose was 30 Gy in 5 fractions and was escalated by 2.5 Gy total for each cohort to 40 Gy. Results: In all, 75 patients were enrolled, with a median age of 62 years. Median follow-up for 5 cohorts was 49.9, 42.5, 25.7, 20.3, and 13.5 months, respectively. Only 3 grade 3 toxicities were experienced. There was 1 dose-limiting toxicity in the overall cohort. Ten patients experienced palpable fat necrosis (4 of which were symptomatic). Physicians scored cosmesis as excellent or good in 95.9%, 100%, 96.7%, and 100% at baseline and 6, 12, and 24 months after S-PBI, whereas patients scored the same periods as 86.5%, 97.1%, 95.1%, and 95.3%, respectively. The disagreement rates between MDs and patients during those periods were 9.4%, 2.9%, 1.6%, and 4.7%, respectively. There have been no recurrences or distant metastases. Conclusion: Dose was escalated to the target dose of 40 Gy in 5 fractions, with the occurrence of only 1 dose-limiting toxicity. Patients felt cosmetic results improved within the first year after surgery and stereotactic body radiation therapy. Our results show minimal toxicity with excellent cosmesis; however, further follow-up is warranted in future studies. This study is the first to show the safety, tolerability, feasibility, and cosmesis results of a 5-fraction dose-escalated S-PBI treatment for early-stage breast cancer in the adjuvant setting.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

How Advances in Imaging Will Affect Precision Radiation Oncology

Radiation oncology is 1 of the most structured disciplines in medicine. It is of a highly technical nature with reliance on robotic systems to deliver intervention, engagement of diverse expertise, and early adoption of digital approaches to optimize and execute the application of this highly effective cancer treatment. As a localized intervention, the dependence on sensitive, specific, and accurate imaging to define the extent of disease, its heterogeneity, and adjacency to normal tissues directly affects the therapeutic ratio. Image-based in vivo temporal monitoring of the response to treatment enables adaptation and further affects the therapeutic ratio. Thus, more precise intervention will enable fractionation schedules that better interoperate with advances such as immunotherapy. In the data set–rich era that promises precision and personalized medicine, the radiation oncology field will integrate these new data into highly protocoled pathways of care that begin with multimodality prediction and enable patient-specific adaptation of therapy based on quantitative measures of the individual's dose–volume temporal trajectory and midtherapy predictions of response. In addition to advancements in computed tomography imaging, emerging technologies, such as ultra-high-field magnetic resonance and molecular imaging will bring new information to the design of treatments. Next-generation image guided radiation therapy systems will inject high specificity and sensitivity data and stimulate adaptive replanning. In addition, a myriad of pre- and peritherapeutic markers derived from advances in molecular pathology (eg, tumor genomics), automated and comprehensive imaging analytics (eg, radiomics, tumor microenvironment), and many other emerging biomarkers (eg, circulating tumor cell assays) will need to be integrated to maximize the benefit of radiation therapy for an individual patient. We present a perspective on the promise and challenges of fully exploiting imaging data in the pursuit of personalized radiation therapy, drawing from the presentations and broader discussions at the 2016 American Society of Therapeutic Radiation Oncology–National Cancer Institute workshop on Precision Medicine in Radiation Oncology (Bethesda, MD).

62 RADIOLOGY AND NUCLEAR MEDICINE↗