Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Repeatability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

A crucible salt saturation method for determining sulfur solubility in glass melt

Experiments were conducted to determine sulfur solubility in Hanford low-activity waste (LAW) glass melts by a sulfur saturation method. Sulfur-incorporated glass melts were prepared by salt saturation and bubbling methods. The salt saturation method was performed by mixing crushed pre-melted baseline glasses with an excess amount of Na2SO4 prior to melting the mixture at 1150°C for one hour. The bubbling method involved bubbling the glass melt at 1150°C in a Pt crucible with an SO2/O2/N2 gas mix to equilibrate the melt at a known pressure of SO3. Preliminary results suggested that performing one cycle of mixing and melting was not sufficient to saturate the glass. The bubbling method successfully incorporated sulfur into the glass but caused significant losses of sodium from the melt. In order to saturate the glass melt with sulfate without causing noticeable sodium loss, a modified crucible salt saturation method was developed by repeating the mixing and melting of the glass and salt mixture. For all three representative LAW glasses tested in this study, it was found that after three mixing and melting cycles, the sulfur concentration reaches a plateau, indicating reasonable sulfur saturation.

Jin, Tongan↗

Evolution of ʟ–DOPA 4,5–dioxygenase activity allows for recurrent specialisation to betalain pigmentation in Caryophyllales

The evolution of ʟ-DOPA 4,5-dioxygenase activity, encoded by the gene DODA, was a key step in the origin of betalain biosynthesis in Caryophyllales. We previously proposed that ʟ-DOPA 4,5-dioxygenase activity evolved via a single Caryophyllales-specific neofunctionalisation event within the DODA gene lineage. However, this neofunctionalisation event has not been confirmed and the DODA gene lineage exhibits numerous gene duplication events, whose evolutionary significance is unclear. To address this, we functionally characterised 23 distinct DODA proteins for ʟ-DOPA 4,5-dioxygenase activity, from four betalain-pigmented and five anthocyanin-pigmented species, representing key evolutionary transitions across Caryophyllales. By mapping these functional data to an updated DODA phylogeny, we then explored the evolution of ʟ-DOPA 4,5-dioxygenase activity. We find that low ʟ-DOPA 4,5-dioxygenase activity is distributed across the DODA gene lineage. In this context, repeated gene duplication events within the DODA gene lineage give rise to polyphyletic occurrences of elevated ʟ-DOPA 4,5-dioxygenase activity, accompanied by convergent shifts in key functional residues and distinct genomic patterns of micro-synteny. In the context of an updated organismal phylogeny and newly inferred pigment reconstructions, we argue that repeated convergent acquisition of elevated ʟ-DOPA 4,5-dioxygenase activity is consistent with recurrent specialisation to betalain synthesis in Caryophyllales.

59 BASIC BIOLOGICAL SCIENCES↗

Structure and sequence evolution in the pennycress ( Thlaspi arvense ) pangenome

Eukaryotic genomes harbor many forms of variation, including nucleotide diversity and structural polymorphisms, which experience natural selection and contribute to genome evolution and biodiversity. Harnessing this variation for agriculture hinges on our ability to detect, quantify, catalog, and deploy genetic diversity. Here, we explore seven complete genomes of the emerging biofuel crop pennycress ( Thlaspi arvense ) drawn from across the species' current genetic diversity to catalog variation in genome structure and content. Across this new pangenome resource, we find contrasting evolutionary modes in different genomic zones. Gene-poor, repeat-rich pericentromeric regions experience frequent rearrangements, including repeated centromere repositioning. By contrast, conserved gene-dense chromosome arms maintain large-scale synteny across accessions even in fast-evolving NOD-like receptor immune genes, where microsynteny breaks down across species, but gene cluster positioning macrosynteny is maintained. Our findings highlight that multiple elements of the genome experience dynamic evolution that conserves functional content on the chromosome scale but allows repositioning and presence–absence variation on a local scale. This diversity is invisible to classical reference-based strategies and highlights the strength and utility of pangenomic resources. These results provide a valuable case study of rapid genomic structural evolution within a species and powerful resources for crop development in an emerging biofuel crop.

Thlaspi arvense↗

Regulation of the Arabidopsis CBF regulon by a complex low‐temperature regulatory network

Summary Exposure of Arabidopsis thaliana plants to low non‐freezing temperatures results in an increase in freezing tolerance that involves action of the C‐repeat binding factor (CBF) regulatory pathway. CBF1 , CBF2 and CBF3 , which are rapidly induced in response to low temperature, encode closely related AP2/ERF DNA‐binding proteins that recognize the C‐repeat (CRT)/dehydration‐responsive element (DRE) DNA regulatory element present in the promoters of CBF‐regulated genes. The CBF transcription factors alter the expression of more than 100 genes, known as the CBF regulon, which contribute to an increase in freezing tolerance. In this study, we investigated the extent to which cold induction of the CBF regulon is regulated by transcription factors other than CBF1, CBF2 and CBF3, and whether freezing tolerance is dependent on a functional CBF–CRT/DRE regulatory module. To address these issues we generated transgenic lines that constitutively overexpressed a truncated version of CBF2 that had dominant negative effects on the function of the CBF–CRT/DRE regulatory module, and 11 transcription factors encoded by genes that were rapidly cold‐induced in parallel with the ‘first‐wave’ CBF genes, and determined the effects that overexpressing these proteins had on global gene expression and freezing tolerance. Our results indicate that cold regulation of the CBF regulon involves extensive co‐regulation by other first‐wave transcription factors; that the low‐temperature regulatory network beyond the CBF pathway is complex and highly interconnected; and that the increase in freezing tolerance that occurs with cold acclimation is only partially dependent on the CBF–CRT/DRE regulatory module.

Park, Sunchung↗

Experimental quantification of vent mechanism flow parameters in 18650 format lithium ion batteries

Lithium ion batteries have a well documented tendency to fail energetically under various abuse conditions. These conditions frequently result in decomposition of the electrochemical components within the battery resulting in gas generation and increased internal pressure which can lead to an explosive case rupture. The 18650 format cell incorporates a vent mechanism located within a crimped cap to relieve pressure and mitigate the risk of case rupture. Cell venting, however, introduces additional safety concerns associated with the flow of flammable gases and liquid electrolyte into the environment. Experiments to quantify key parameters are performed to elucidate the external dynamics of battery venting. A first experiment measures the vent burst pressure. Burst vent caps are then tested with a second experimental fixture to measure vent opening area and discharge coefficient during choked-flow venting, which occurs during battery failure. Vent opening area and discharge coefficient are calculated from stagnation temperature, stagnation pressure, and static pressure measurements along with compressible-isentropic flow equations and conservation of mass. Commercially-sourced vent caps are used with repeated tests run to quantify repeatability and variability. Validation experiments confirmed accuracy of opening area and discharge coefficient measurement. Moreover, trials conducted on vent caps from two sources demonstrate the potential for variation between manufacturers.

25 ENERGY STORAGE↗

Effect of Hydrogen on Steady-State and Transient Combustion Instability Characteristics

This paper examines the effects of steady-state and transient hydrogen enrichment on thermoacoustic instability in a model gas turbine combustor. Combustion instability, a feedback loop between flame heat release rate oscillations and combustor acoustics, is characterized in a swirl-stabilized flame operated at a range of hydrogen–natural gas fuel blends and heat rates. Measurements of combustor chamber pressure fluctuations and CH* chemiluminescence imaging are used to characterize instability at a range of operating conditions. Steady-state tests show that both mixture heat rate and hydrogen content affect system stability. At a given heat rate, higher levels of hydrogen result in unstable combustion. As heat rate increases, instability occurs at lower concentrations of hydrogen in the fuel. Transient operation was tested in two directions—instability onset and decay—and two hydrogen-addition times—a short time of 1 ms and a longer time of 4 s. Results show that instability onset processes, through the transient addition of hydrogen, are highly repeatable regardless of the timescale of hydrogen addition. Certain instability decay processes are less repeatable, resulting in cases that do not fully transition from unstable to stable combustion despite similar changes in hydrogen fuel flow rate. Flame behavior before, during, and after the transient is characterized using high-speed CH* chemiluminescence imaging. Analysis of the high-speed images shows changes in flame stabilization and dynamics during the onset and decay processes. Finally, the results of this study can have implications for systems that experience variations in fuel composition, particularly in light of growing interest in hydrogen as a renewable fuel.

42 ENGINEERING↗

Main Street Zero Energy Buildings: The Zero Energy Method in Concept and Practice: Preprint

Ongoing work at the National Renewable Energy Laboratory indicates that net-zero energy building (NZEB) status is both achievable and repeatable today. This paper presents a definition framework for classifying NZEBs and a real-life example that demonstrates how a large-scale office building can cost-effectively achieve net-zero energy.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Assessment of Experimental Uncertainty for a Floating Wind Semisubmersible Under Hydrodynamic Loading

The objective of this paper is to assess the sources of experimental uncertainty in an offshore wind validation campaign focused on better understanding the nonlinear hydrodynamic response behavior of a floating semisubmersible. The test specimen and conditions were simplified compared to other floating wind test campaigns to reduce potential sources of uncertainties and better focus on the hydrodynamic load attributes. Repeat tests were used to understand the repeatability of the test conditions and to assess the level of random uncertainty in the measurements. Attention was also given to understanding bias in all components of the test. The end goal of this work is to set uncertainty bounds on the response metrics of interest, which will be used in future work to evaluate the success of modeling tools in accurately calculating hydrodynamic loads and the associated motion responses of the system.

17 WIND ENERGY↗

REGULATORY TESTING AND POSTTEST ANALYSIS OF THE DPP-3 TYPE B SHIPPING CONTAINER FOR NCT AND HAC TESTS

The safe transportation of radioactive material using appropriately designed and certified transportation packages is important to protect the public and environment. Therefore, a comprehensive and rigorous system of packaging requirements are required. The purpose of this test protocol is to determine the effects of drop testing on package performance in a Type B shipping package (DPP-3). Required physical tests for the DPP-3 package include normal conditions of transport and hypothetical accident conditions test requirements. The preparation, regulatory testing, and post-test evaluation of a Type B shipping package tested to the 10 CFR 71.71 and 10 CFR 71.73 requirements will be presented. Six packages were tested and the responses when subjected to the HAC sequence of free drop, puncture, and thermal tests according to 10 CFR 71.73 were measured. The posttest helium leak test showed a leak rate less than 1 × 10-7 He-cc/sec which means that the containment boundary was maintained after the regulatory testing, therefore maintaining a leak tight environment. To determine the amount of change in the package performance measurements, statistical analyses were conducted using SPSS version 26. The null hypothesis of the testing was that there would not be a change in the measurements from pre to post-testing large enough to find statistical significance. Therefore, a finding of statistical significance indicated too much variability in the package design and was deemed an unfavorable finding. A repeated measures t-test was used to analyze the drum lids and CV torques. A one-way ANOVA was used to analyze height and diameter packages. Results of the repeated measures t-test indicated that all six containment vessel lid torques were statistically significant. However only three out of the six drum lid torques were statistically significant. Therefore, design of the lids caused more variability than necessary when subjected to the following drop tests: 1.) horizontal and cold; 2.) vertical lid down; and 3.) corner with lid up. Results of the one-way ANOVA analysis on height indicated that four out of the six CTUs were statistically significant. Thus, design of the CTUs caused more variability then necessary when subjected to the following drop tests: 1.) horizontal hot; 2.) horizontal cold; 3.) corner lid up; and 4.) corner lid down. Results of the one-way ANOVA analysis on diameter indicated that all six CTUs were statistically significant. Thus, design of the CTUs caused more variability then necessary when subjected to all of the tests. The DPP-3 design has been shown to be an acceptable design for the transport of radioactive materials. However, results of the statistical analysis reveal a possible improvement in package and test design to reduce variability in package performance measurement before and after testing.

Martinez, Oscar↗

Atomic layer deposition of Al2O3 on V2O5 xerogel film for enhanced lithium-ion intercalation stability

V2O5 xerogel films were fabricated by casting V2O5 sols onto fluorine-doped tin oxide glass substrates at room temperature. Five, ten and twenty atomic layers of Al2O3 were grown onto as-fabricated films respectively. The bare film and Al2O3-deposited films all exhibited hydrous V2O5 phase only. Electrochemical impedance spectroscopy study revealed increased surface charge-transfer resistance of V2O5 films as more Al2O3 atomic layers were deposited. Lithium-ion intercalation tests at 600 mAg_1 showed that bare V2O5 xerogel film possessed high initial discharge capacity of 219 mAhg_1 but suffered from severe capacity degradation, i.e., having only 136 mAhg_1 after 50 cycles. After deposition of ten atomic layers of Al2O3, the initial discharge capacity was 195 mAhg_1 but increased over cycles before stabilizing; after 50 cycles, the discharge capacity was as high as 225 mAhg_1. The noticeably improved cyclic stability of Al2O3-deposited V2O5 xerogel film could be attributed to the improved surface chemistry and enhanced mechanical strength. During repeated lithium-ion intercalation/de-intercalation, atomic layers of Al2O3 which were coated onto V2O5 surface could prevent V2O5 electrode dissolution into electrolyte by reducing direct contact between active electrode and electrolyte while at the same time acting as binder to maintain good mechanical contact between nanoparticles inside the film. VC 2012 American Vacuum Society.

36 MATERIALS SCIENCE↗

Ultrathin stable Ohmic contacts for high-temperature operation of β -Ga2O3 devices

Beta gallium oxide (β-Ga2O3) shows significant promise in high-temperature, high-power, and sensing electronics applications. However, long-term stable metallization layers for Ohmic contacts at high temperatures present unique thermodynamic challenges. The current most common Ohmic contact design based on 20 nm of Ti has been repeatedly demonstrated to fail at even moderately elevated temperatures (300–400 °C) due to a combination of nonstoichiometric Ti/Ga2O3 interfacial reactions and kinetically favored Ti diffusion processes. Here, we demonstrate stable Ohmic contacts for Ga2O3 devices operating up to 500–600 °C using ultrathin Ti layers with a self-limiting interfacial reaction. The ultrathin Ti layer in the 5 nm Ti/100 nm Au contact stack is designed to fully oxidize while forming an Ohmic contact, thereby limiting both thermodynamic and kinetic instability. This novel contact design strategy results in an epitaxial conductive anatase titanium oxide interface layer that enables low-resistance Ohmic contacts that are stable both under long-term continuous operation (>500 h) at 600 °C in vacuum (≤10−4 Torr), as well as after repeated thermal cycling (15 times) between room temperature and 550 °C in flowing N2. This stable Ohmic contact design will accelerate the development of high-temperature devices by enabling research focus to shift toward rectifying interfaces and other interfacial layers.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Image quality, meteorological optical range, and fog particulate number evaluation using the Sandia National Laboratories fog chamber

The evaluation of optical system performance in fog conditions typically requires field testing. This can be challenging due to the unpredictable nature of fog generation and the temporal and spatial nonuniformity of the phenomenon itself. We describe the Sandia National Laboratories fog chamber, a new test facility that enables the repeatable generation of fog within a 55 m×3 m×3 m (L×W×H) environment, and demonstrate the fog chamber through a series of optical tests. These tests are performed to evaluate system image quality, determine meteorological optical range (MOR), and measure the number of particles in the atmosphere. Relationships between typical optical quality metrics, MOR values, and total number of fog particles are described using the data obtained from the fog chamber and repeated over a series of three tests.

47 OTHER INSTRUMENTATION↗

Characterization of optically stimulated luminescent dosimeters, OSLDs, for clinical dosimetric measurements

Optically stimulated luminescent dosimeters, OSLDs, are plastic disks infused with aluminum oxide doped with carbon (Al{sub 2}O{sub 3}:C). These disks are encased in a light-tight plastic holder. Crystals of Al{sub 2}O{sub 3}:C when exposed to ionizing radiation store energy that is released as luminescence (420 nm) when the OSLD is illuminated with stimulation light (540 nm). The intensity of the luminescence depends on the dose absorbed by the OSLD and the intensity of the stimulation light. OSLDs used in this work were InLight/OSL Dot dosimeters, which were read with a MicroStar reader (Landauer, Inc., Glenwood, IL). The following are dosimetric properties of the OSLD that were determined: After a single irradiation, repeated readings cause the signal to decrease by 0.05% per reading; the signal could be discharged by greater than 98% by illuminating them for more than 45 s with a 150 W tungsten-halogen light; after irradiation there was a transient signal that decayed with a 0.8 min halftime; after the transient signal decay the signal was stable for days; repeated irradiations and readings of an individual OSLD gave a signal with a coefficient of variation of 0.6%; the dose sensitivity of OSLDs from a batch of detectors has a coefficient of variation of 0.9%, response was linear with absorbed dose over a test range of 1-300 cGy; above 300 cGy a small supra-linear behavior occurs; there was no dose-per-pulse dependence over a 388-fold range; there was no dependence on radiation energy or mode for 6 and 15 MV x rays and 6-20 MeV electrons; for Ir-192 gamma rays OSLD had 6% higher sensitivity; the dose sensitivity was unchanged up to an accumulated dose of 20 Gy and thereafter decreased by 4% per 10 Gy of additional accumulated dose; dose sensitivity was not dependent on the angle of incidence of radiation; the OSLD in its light-tight case has an intrinsic buildup of 0.04 g/cm{sup 2}; dose sensitivity of the OSLD was not dependent on temperature at the time of irradiation in the range of 10-40 deg. C. The clinical use of OSLDs for in vivo dosimetric measurements is shown to be feasible.

61 RADIATION PROTECTION AND DOSIMETRY↗

In vivo 3D modeling of the femoropopliteal artery in human subjects based on x-ray angiography: Methodology and validation

Endovascular revascularization of the femoropopliteal (FP) artery has been limited by high rates of restenosis and stent fracture. The unique physical forces that are applied to the FP artery during leg movement have been implicated in these phenomena. The foundation for measuring the effects of physical forces on the FP artery in a clinically relevant environment is based on the ability to develop 3D models of this vessel in different leg positions in vivo in patients with peripheral arterial disease (PAD). By acquiring paired angiographic images of the FP artery, and using angiography-based 3D modeling algorithms previously validated in the coronary arteries, the authors generated 3D models of ten FP arteries in nine patients with PAD with the lower extremity in straight leg (SL) and crossed leg (CL) positions. Due to the length of the FP artery, overlapping paired angiographic images of the entire FP artery were required to image the entire vessel, which necessitated the development of a novel fusion process in order to generate a 3D model of the entire FP artery. The methodology of angiographic acquisition and 3D model generation of the FP artery is described. In a subset of patients, a third angiographic view (i.e., validation view) was acquired in addition to the standard paired views for the purpose of validating the 3D modeling process. The mean root-mean-square (rms) error of the point-to-point distances between the centerline of the main FP artery from the 2D validation view and the centerline from the 3D model placed in the validation view for the SL and CL positions were 0.93{+-}0.19 mm and 1.12{+-}0.25 mm, respectively. Similarly, the mean rms error of the same comparison for the main FP artery and sidebranches for the SL and CL positions were 1.09{+-}0.38 mm and 1.21{+-}0.25 mm, respectively. A separate validation of the novel fusion process was performed by comparing the 3D model of the FP artery derived from fusion of 3D models of adjacent FP segments with the 2D validation view incorporating the region of fusion. The mean rms error of vessel centerline points of the main FP artery, the main FP artery plus directly connected sidebranches, and the mean rms error of upstream, downstream, and sidebranch directional vectors at bifurcation points in the overlap region were 1.41{+-}0.79 mm, 2.13{+-}1.12 mm, 3.16{+-}3.72 deg., 3.60{+-}5.39 deg., and 8.68{+-}8.42 deg. in the SL position, respectively, and 1.29{+-}0.35 mm, 1.61{+-}0.78 mm, 4.68{+-}4.08 deg., 3.41{+-}2.23 deg., and 5.52{+-}4.41 deg. in the CL position, respectively. Inter- and intraobserver variability in the generation of 3D models of individual FP segments and the fusion of overlapping FP segments were assessed. The mean rms errors between the centerlines of nine 3D models of individual FP segments generated by two independent observers, and repeated measurement by the same observer were 2.78{+-}1.26 mm and 3.50{+-}1.15 mm, respectively. The mean rms errors between the centerline of four 3D models of fused overlapping FP segments generated by two independent observers, and repeated measurement by the same observer were 4.99{+-}0.99 mm and 5.98{+-}1.22 mm, respectively. This study documents the ability to generate 3D models of the entire FP artery in vivo in patients with PAD in both SL and CL positions using routine angiography, and validates the methodologies used.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantitative CT of lung nodules: Dependence of calibration on patient body size, anatomic region, and calibration nodule size for single- and dual-energy techniques

Calcium concentration may be a useful feature for distinguishing benign from malignant lung nodules in computer-aided diagnosis. The calcium concentration can be estimated from the measured CT number of the nodule and a CT number vs calcium concentration calibration line that is derived from CT scans of two or more calcium reference standards. To account for CT number nonuniformity in the reconstruction field, such calibration lines may be obtained at multiple locations within lung regions in an anthropomorphic phantom. The authors performed a study to investigate the effects of patient body size, anatomic region, and calibration nodule size on the derived calibration lines at ten lung region positions using both single energy (SE) and dual energy (DE) CT techniques. Simulated spherical lung nodules of two concentrations (50 and 100 mg/cc CaCO{sub 3}) were employed. Nodules of three different diameters (4.8, 9.5, and 16 mm) were scanned in a simulated thorax section representing the middle of the chest with large lung regions. The 4.8 and 9.5 mm nodules were also scanned in a section representing the upper chest with smaller lung regions. Fat rings were added to the peripheries of the phantoms to simulate larger patients. Scans were acquired on a GE-VCT scanner at 80, 120, and 140 kVp and were repeated three times for each condition. The average absolute CT number separations between the calibration lines were computed. In addition, under- or overestimates were determined when the calibration lines for one condition (e.g., small patient) were used to estimate the CaCO{sub 3} concentrations of nodules for a different condition (e.g., large patient). The authors demonstrated that, in general, DE is a more accurate method for estimating the calcium contents of lung nodules. The DE calibration lines within the lung field were less affected by patient body size, calibration nodule size, and nodule position than the SE calibration lines. Under- or overestimates in CaCO{sub 3} concentrations of nodules were also in general smaller in quantity with DE than with SE. However, because the slopes of the calibration lines for DE were about one-half the slopes for SE, the relative improvement in the concentration estimates for DE as compared to SE was about one-half the relative improvement in the separation between the calibration lines. Results in the middle of the chest thorax section with large lungs were nearly completely consistent with the above generalization. On the other hand, results in the upper-chest thorax section with smaller lungs and greater amounts of muscle and bone were mixed. A repeat of the entire study in the upper thorax section yielded similar mixed results. Most of the inconsistencies occurred for the 4.8 mm nodules and may be attributed to errors caused by beam hardening, volume averaging, and insufficient sampling. Targeted, higher resolution reconstructions of the smaller nodules, application of high atomic number filters to the high energy x-ray beam for improved spectral separation, and other future developments in DECT may alleviate these problems and further substantiate the superior accuracy of DECT in quantifying the calcium concentrations of lung nodules.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Nondestructive measurement of the grid ratio using a single image

The antiscatter grid is an essential part of modern radiographic systems. Since the introduction of the antiscatter grid, however, there have been few methods proposed for acceptance testing and verification of manufacturer-supplied grid specifications. The grid ratio (r) is an important parameter describing the antiscatter grid because it affects many other grid quality metrics, such as the contrast improvement ratio (K), primary transmission (T{sub p}), and scatter transmission (T{sub s}). Also, the grid ratio in large part determines the primary clinical use of the grid. To this end, the authors present a technique for the nondestructive measurement of the grid ratio of antiscatter grids. They derived an equation that can be used to calculate the grid ratio from a single off-focus flat field image by exploiting the relationship between grid cutoff and off-focus distance. The calculation can be performed by hand or with included analysis software. They calculated the grid ratios of several different grids throughout the institution, and afterward they destructively measured the grid ratio of a nominal r8 grid previously evaluated with the method. They also studied the sensitivity of the method to technical factors and choice of parameters. With one exception, the results for the grids found in the institution were in agreement with the manufacturer's specifications and international standards. The nondestructive evaluation of the r8 grid indicated a ratio of 7.3, while the destructive measurement indicated a ratio of 7.53{+-}0.28. Repeated evaluations of the same grid yielded consistent results. The technique provides the medical physicist with a new tool for quantitative evaluation of the grid ratio, an important grid performance criterion. The method is robust and repeatable when appropriate choices of technical factors and other parameters are made.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A solid iodinated phantom material for use in tomographic x-ray imaging

PURPOSE: Iodinated phantoms are of value in x-ray imaging for quality control measurements, system calibration, and for use in the research setting; however, the liquid phantoms that are most often used have several limitations including variability between repeated dilutions, inhomogeneities from air bubbles or precipitants, and long set up times. Although suitable materials have been investigated for projection radiography, quantitative measurements of contrast enhancement in computed tomography (CT) have become increasingly important in the clinic, and a need exists for a durable and reproducible iodinated phantom material. In this work, the authors describe a solid radiographic phantom material that has an accurately known concentration of iodine distributed uniformly throughout its volume and that has stable properties over time. This material can be molded or machined into a desired shape to create a test object or for use in an anthropomorphic phantom. Methods: Two sets of calibration phantoms were produced with a clinically relevant range of iodine concentrations. Measurements were made on these phantoms to characterize the material properties in terms of accuracy of iodine concentration, radiographic uniformity, temporal stability of x-ray attenuation, and manufacturing repeatability. Experimentally measured linear x-ray attenuation coefficients were compared to those predicted by a theoretical model. The uniformity of the iodine distribution in the material was assessed by measuring image intensity variation, both in projection images and in reconstructed CT volumes. The reproducibility of manufacture was estimated on a set of independently produced samples. A longitudinal study was performed to assess the stability of the material x-ray characteristics over time by making measurements at 6 month intervals. Results: Good agreement was seen between the experimental measurements of effective attenuation and the theoretically predicted values. It is estimated that a desired iodine concentration could be produced to within 0.04 mg/ml. Comparison of the measured effective linear iodine attenuation coefficients of eight 1.0 mg/ml samples indicated a manufacturing reproducibility of {+-}0.03 mg/ml iodine. Variations in uniformity across each of the samples were on the order of image intensity fluctuations ({sigma}). No inhomogeneities due to mixing or settling were apparent. An analysis of longitudinal data collected for both calibration sets revealed no perceptible change in radiographic properties over the first 6 months after manufacture, nor over a subsequent 1.5 yr period from 1 yr postmanufacture onward. Conclusions: The uniformity, stability, and precision of this iodinated material suggest that it is suitable for use in accurate calibration tools for contrast tomographic imaging.

36 MATERIALS SCIENCE↗