Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Reference Values”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

Towards a theory of economic value for modeling and simulation: incremental cost of parallel simulation (wip)

A useful perspective on the economic value of simulation in engineering comes from considering the role simulation plays in constructing a system. We propose a conceptual model that combines an embryonic concept of the value of an information bit with cost estimation tools used in software engineering. The model provides an economic justification for the common conception that models should be built to address specific questions rather than to comprehensively represent a referent system. Extending these ideas, we offer a model for the incremental value of parallel execution to explain why simulation applications that take advantage of sophisticated parallel discrete event simulation tools form a relatively narrow niche despite the ubiquity of parallel computing hardware. The proposed model enables us to bring value of information criteria into model development and to make predictions about the future of parallel simulation applications.

Nutaro, James J↗

Correlation of 3T multiparametric prostate MRI using prostate imaging reporting and data system (PIRADS) version 2 with biopsy as reference standard

Objective: To correlate the findings on 3T multiparametric prostate MRI using PIRADS version 2 with prostate biopsy results as the standard of reference. Materials and methods: 134 consecutive treatment naive patients (mean age 64 years, range 41–82 years) underwent MRI-directed prostate biopsy. MRI–TRUS fusion biopsy was used for 77 (77/134 = 57.5%) patients, cognitive fusion for 51 (51/134 = 38.0%) patients, and 6 patients (6/134 = 4.5%) without a target nodule had systematic biopsy only. Out of the 1676 biopsy sites, 237 (237/1676 = 14.1%) were positive on MRI for a PIRADS 3, 4, or 5 nodule. Fifty-eight (58/134, 43.3%) patients had clinically significant prostate cancer (csPCa). The findings on MRI using PIRADS version 2 were correlated with the biopsy results. Results: The accuracy, sensitivity, specificity, positive predictive value, and negative predictive value of PIRADS ≥ 3 for csPCa were 89%, 76.5%, 89.7%, 31.7%, and 98.4%, respectively. The detection rates of csPCa for PIRADS 3, 4, and 5 nodules were 6.1% (4/66), 33.3% (42/126), and 64.4% (29/45), respectively. MRI did not identify a nodule in 23/1676 (1.4%) biopsy sites that contained csPCa. The MRI reader, biopsy operator, method of fusion biopsy, and zonal location of prostate nodule did not significantly affect the odds of having a biopsy result positive for csPCa. Conclusion: PIRADS ≥ 3 had high specificity and high negative predictive value for csPCa using biopsy results as the standard of reference. The presence of csPCa from a biopsy site was highly unlikely in the absence of a corresponding PIRADS ≥ 3 nodule.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Elemental ratio measurements of organic compounds using aerosol mass spectrometry: characterization, improved calibration, and implications

Elemental compositions of organic aerosol (OA) particles provide useful constraints on OA sources, chemical evolution, and effects. The Aerodyne high-resolution time-of-flight aerosol mass spectrometer (HR-ToF-AMS) is widely used to measure OA elemental composition. This study evaluates AMS measurements of atomic oxygen-to-carbon (O : C), hydrogen-to-carbon (H : C), and organic mass-to-organic carbon (OM : OC) ratios, and of carbon oxidation state ( OS C ) for a vastly expanded laboratory data set of multifunctional oxidized OA standards. For the expanded standard data set, the method introduced by Aiken et al. (2008), which uses experimentally measured ion intensities at all ions to determine elemental ratios (referred to here as "Aiken-Explicit"), reproduces known O : C and H : C ratio values within 20% (average absolute value of relative errors) and 12%, respectively. The more commonly used method, which uses empirically estimated H 2 O + and CO + ion intensities to avoid gas phase air interferences at these ions (referred to here as "Aiken-Ambient"), reproduces O : C and H : C of multifunctional oxidized species within 28 and 14% of known values. The values from the latter method are systematically biased low, however, with larger biases observed for alcohols and simple diacids. A detailed examination of the H 2 O + , CO + , and CO 2 + fragments in the high-resolution mass spectra of the standard compounds indicates that the Aiken-Ambient method underestimates the CO + and especially H 2 O + produced from many oxidized species. Combined AMS–vacuum ultraviolet (VUV) ionization measurements indicate that these ions are produced by dehydration and decarboxylation on the AMS vaporizer (usually operated at 600 °C). Thermal decomposition is observed to be efficient at vaporizer temperatures down to 200 °C. These results are used together to develop an "Improved-Ambient" elemental analysis method for AMS spectra measured in air. The Improved-Ambient method uses specific ion fragments as markers to correct for molecular functionality-dependent systematic biases and reproduces known O : C (H : C) ratios of individual oxidized standards within 28% (13%) of the known molecular values. The error in Improved-Ambient O : C (H : C) values is smaller for theoretical standard mixtures of the oxidized organic standards, which are more representative of the complex mix of species present in ambient OA. For ambient OA, the Improved-Ambient method produces O : C (H : C) values that are 27% (11%) larger than previously published Aiken-Ambient values; a corresponding increase of 9% is observed for OM : OC values. These results imply that ambient OA has a higher relative oxygen content than previously estimated. The OS C values calculated for ambient OA by the two methods agree well, however (average relative difference of 0.06 OS C units). This indicates that OS C is a more robust metric of oxidation than O : C, likely since OS C is not affected by hydration or dehydration, either in the atmosphere or during analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

TeMPI Shim

This is the manual for the TeMPI Shim library, whose goal is to facilitate scientific apps being loosely coupled through MPI. TeMPI Shim can be used to create and manage Message Passing Interface (MPI, see [MPI]) Communicators for Single Program, Multiple Data (SPMD, see [SPMD]) and Multiple Programs, Multiple Data (MPMD, see [MPMD]) workflows. MPI provides the MPI_APPNUM command number to each of the processes within its context. This number, starting at 0, is the application number being executed. In a case where 3 applications are being run in MPMD mode, there would be MPI_APPNUM values of 0, 1, and 2. TeMPI Shim creates intra- and inter-communicators between each pair of MPI_APPNUM values. In the aforementioned case, application 0 would have intra- and inter-communicators to speak to itself, application 1, and application 2. This is replicated for each of the applications. Additionally, TeMPI Shim creates intra- and inter-communicators for the first MPI rank of each application to directly communicate only with each other. Finally, TeMPI Shim creates its own copy of the default world communicator, i.e., MPI_COMM_WORLD. In the case where there is only a single application, it will have the communicators to only speak with itself. TeMPI Shim is useful in this case since it is considered good practice for MPI applications to copy the default world communicator and reference this copy (see [Duplicate World]_) anyways. Ultimately, it provides value independent of the number of applications present.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

New Releases and Upgrades of Giant Planet Global Reference Atmospheric Models (GRAMs)

• GRAMs are engineering-oriented atmospheric models that estimate mean values and statistical variations of atmospheric properties for numerous planetary destinations – Outputs atmospheric density, temperature, pressure, winds, and chemical composition along a user-defined path – Provide mean values and variability for any point in an atmosphere – Includes seasonal, geographic, and altitude variations – Used by engineering community because of their ability to create realistic atmospheric dispersions; can be integrated into high fidelity flight dynamic simulations of launch, entry, descent, and landing (EDL), aerobraking, and aerocapture • GRAMs are not forecast models • GRAMs are available for: Earth, Mars, Venus, Neptune, Titan, Jupiter, and Uranus • Available through the NASA Software Catalog https://software.nasa.gov/software/MFS-33888-1

atmospheric models↗

New NBL Pu Isotopic Standards C137A and C136A as Working Reference Materials for Radiochronometry in Nuclear Forensics

Lawrence Livermore National Laboratory (LLNL) and the NBL Program Office (NBL PO) are collaborating on production of purified sub-units of the former NBS 936, 937 and 938 plutonium isotopic reference materials, which will be certified for plutonium isotopic composition and sold as certified reference materials (CRMs) C136A, C137A, and C138A, respectively. These reference materials are used throughout the United States and international community as standards for isotopic measurement method calibration and quality control and were first produced over 50 years ago. To reduce quantities of in-grown daughter products and potentially enable their use as Pu radiochronometry reference materials, the materials undergo a two-stage anion exchange purification to significantly reduce the quantities of U, Am, and Np in the source material. The purified Pu is aliquoted into ~1 mg units in the nitrate form, which will facilitate easier shipping and use compared to the 0.25 g parent units. The production process has been completed for the high- and medium- burnup isotopic standards C137A and C136A and will soon be performed for the weapons-grade Pu standard C138A. This report describes the measurement of trace actinide progeny of the Pu isotopes ( 234 U, 235 U, 236U, 241 Am and 237 Np) in purified C137A and 136A isotopic standards to provide informational values and assess the possibility of their use as working reference materials for radiochronometry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Polarization analysis by off-axis digital holography with an improved optical system and an evaluation of its performance by simulation

An optical system of off-axis digital holography for imaging the Jones vector of an object wave is improved, and a Faraday rotator for the reference wave is also newly constructed. To evaluate the accuracy of the polarization analysis, quarter- and half-wave plates are used as the object, and the distribution of the polarization state of the transmitted light is analyzed for various orientations of the wave plates. The polarization analysis is also simulated, and the effect of a finite value of the extinction ratio and the modulation error for the reference wave is investigated numerically.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Vulnerability of Karangkates dams area by means of zero crossing analysis of data magnetic

Study with entitled Vulnerability Karangkates Dam Area By Means of Zero Crossing Analysis of Data Magnetic has been done. The study was aimed to obtain information on the vulnerability of two parts area of Karangkates dams, i.e. Lahor dam which was inaugurated in 1977 and Sutami dam inaugurated in 1981. Three important things reasons for this study are: 1). The dam age was 36 years old for Lahor dam and 32 years old for Sutami dam, 2). Geologically, the location of the dams are closed together to the Pohgajih local shear fault, Selorejo local fault, and Selorejo limestone-andesite rocks contact plane, and 3). Karangkates dams is one of the important Hydro Power Plant PLTA with the generating power of about 400 million KWH per year from a total of about 29.373MW installed in Indonesia. Geographically, the magnetic data acquisition was conducted at coordinates (112.4149oE;-8.2028oS) to (112.4839oE;-8.0989oS) by using Proton Precession Magnetometer G-856. Magnetic Data acquisition was conducted in the radial direction from the dams with diameter of about 10 km and the distance between the measurements about 500m. The magnetic data acquisition obtained the distribution of total magnetic field value in the range of 45800 nT to 44450 nT. Residual anomalies obtained by doing some corrections, including diurnal correction, International Geomagnetic Reference Field (IGRF) correction, and reductions so carried out the distribution of the total magnetic field value in the range of -650 nT to 700 nT. Based on the residual anomalies, indicate the presence of 2 zones of closed closures dipole pairs at located in the west of the Sutami dam and the northwest of the Lahor dam from 5 total zones. Overlapping on the local geological map indicated the lineament of zero crossing patterns in the contour of residual anomaly contour with the Pohgajih shear fault where located at about 4 km to the west of the Sutami dam approximately and andesite-limestone rocks contact where located at about 6 km to the west of the Lahor dam approximately. These shown a possible of vulnerability on geohazards at the west zone of the Karangkates (Lahor-Sutami) dams area if there are triggers by the vibration (earthquake) on the Pohgajih shear fault, andesite-limestone contact plane, and instability rocks on two zones of closed closure dipole pairs area. Reality, on the location of the study shown some local landslide at the several locations and the main road that need considering for disaster mitigation.

58 GEOSCIENCES↗

Semiautomatic registration of 3D transabdominal ultrasound images for patient repositioning during postprostatectomy radiotherapy

Purpose: The aim of the present work is to propose and evaluate registration algorithms of three-dimensional (3D) transabdominal (TA) ultrasound (US) images to setup postprostatectomy patients during radiation therapy. Methods: Three registration methods have been developed and evaluated to register a reference 3D-TA-US image acquired during the planning CT session and a 3D-TA-US image acquired before each treatment session. The first method (method A) uses only gray value information, whereas the second one (method B) uses only gradient information. The third one (method C) combines both sets of information. All methods restrict the comparison to a region of interest computed from the dilated reference positioning volume drawn on the reference image and use mutual information as a similarity measure. The considered geometric transformations are translations and have been optimized by using the adaptive stochastic gradient descent algorithm. Validation has been carried out using manual registration by three operators of the same set of image pairs as the algorithms. Sixty-two treatment US images of seven patients irradiated after a prostatectomy have been registered to their corresponding reference US image. The reference registration has been defined as the average of the manual registration values. Registration error has been calculated by subtracting the reference registration from the algorithm result. For each session, the method has been considered a failure if the registration error was above both the interoperator variability of the session and a global threshold of 3.0 mm. Results: All proposed registration algorithms have no systematic bias. Method B leads to the best results with mean errors of −0.6, 0.7, and −0.2 mm in left–right (LR), superior–inferior (SI), and anterior–posterior (AP) directions, respectively. With this method, the standard deviations of the mean error are of 1.7, 2.4, and 2.6 mm in LR, SI, and AP directions, respectively. The latter are inferior to the interoperator registration variabilities which are of 2.5, 2.5, and 3.5 mm in LR, SI, and AP directions, respectively. Failures occur in 5%, 18%, and 10% of cases in LR, SI, and AP directions, respectively. 69% of the sessions have no failure. Conclusions: Results of the best proposed registration algorithm of 3D-TA-US images for postprostatectomy treatment have no bias and are in the same variability range as manual registration. As the algorithm requires a short computation time, it could be used in clinical practice provided that a visual review is performed.

60 APPLIED LIFE SCIENCES↗

Role of higher-multipole deformations in exotic {sup 14}C cluster radioactivity

We have studied nine cases of spontaneous emission of {sup 14}C clusters in the ground-state decays of the same number of parent nuclei from the trans-lead region, specifically from {sup 221}Fr to {sup 226}Th, using the preformed cluster model (PCM) of Gupta and collaborators, with choices of spherical, quadrupole deformation ({beta}{sub 2}) alone, and higher-multipole deformations ({beta}{sub 2}, {beta}{sub 3}, {beta}{sub 4}) with cold ''compact'' orientations {theta}{sup c} of decay products. The calculated {sup 14}C cluster decay half-life times are found to be in nice agreement with experimental data only for the case of higher-multipole deformations ({beta}{sub 2}-{beta}{sub 4}) and {theta}{sup c} orientations of cold elongated configurations. In other words, compared to our earlier study of clusters heavier than {sup 14}C, where the inclusion of {beta}{sub 2} alone, with ''optimum'' orientations, was found to be enough to give the best comparison with data, here for {sup 14}C cluster decay the inclusion of higher-multipole deformations (up to hexadecapole), together with {theta}{sup c} orientations, is found to be essential on the basis of the PCM. Interestingly, whereas both the penetration probability and assault frequency work simply as scaling factors, the preformation probability is strongly influenced by the order of multipole deformations and orientations of nuclei. The possible role of Q value and angular-momentum effects are also considered in reference to {sup 14}C cluster radioactivity.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Chemical thermodynamic data. 1. The concept of links to the chemical elements and the historical development of key thermodynamic data [plus Supplementary Electronic Annex 2]

Chemical thermodynamic data remain a keystone for geochemical modeling and reactive transport simulation as applied to an increasing number of applications in the earth sciences, as well as applications in other areas including metallurgy, material science, and industrial process design. The last century has seen the development of a large body of thermodynamic data and a number of major compilations. The past several decades have seen the development of thermodynamic databases in digital form designed to support computer calculations. However, problems with thermodynamic data appear to be persistent. One problem pertains to the use of inconsistent primary key reference data. Such data pertain to elemental reference forms and key, stoichiometrically simple chemical species including metal oxides, CO 2 , water, and aqueous species such as Na + and Cl - . A consistent set of primary key data (standard Gibbs energies, standard enthalpies, and standard entropies for key chemical species) for 298.15K and 1 bar pressure is essential. Thermochemical convention is to define the standard Gibbs energy and the standard enthalpy of an individual chemical species in terms of formation from reference forms of the constituent chemical elements. We propose a formal concept of “links” to the elemental reference forms. This concept involves a documented understanding of all reactions and calculations leading to values for a formation property (standard Gibbs energy or enthalpy). A valid link consists of two parts: (a) the path of reactions and corrections and (b) the associated data, which are key data. Such a link differs from a bare “key” or “reference” datum in that it requires additional information. Some or all of its associated data may also be key data. In evaluating a reported thermodynamic datum, one should identify the links to the chemical elements, a process which can be time-consuming and which may lead to a dead end (an incomplete link). The use of two or more inconsistent links to the same elemental reference form in a thermodynamic database will result in an inconsistency in the database. Thus, in constructing a database, it is important to establish a set of reliable links (generally resulting in a set of primary reference data) and then correct all data adopted subsequently for consistency with that set. Recommended values of key data have not been constant through history. We review some of this history through the lens of major compilations and other influential reports, and note a number of problem areas. Finally, we illustrate the concepts developed in this paper by applying them to some key species of geochemical interest, including liquid water; quartz and aqueous silica; and gibbsite, corundum, and the aqueous aluminum ion.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Neutron star solutions in perturbative quadratic gravity

We study the structure of neutron stars in R+βR{sup μν}R{sub μν} gravity model with perturbative method. We obtain mass-radius relations for six representative equations of state (EoSs). We find that, for |β| ∼ 10{sup 11} cm{sup 2}, the results differ substantially from the results of general relativity. Some of the soft EoSs that are excluded within the framework of general relativity can be reconciled for certain values of β of this order with the 2 solar mass neutron star recently observed. For values of β greater than a few 10{sup 11} cm{sup 2} we find a new solution branch allowing highly massive neutron stars. By referring some recent observational constraints on the mass–radius relation we try to constrain the value of β for each EoS. The associated length scale (β){sup 1/2} ∼ 10{sup 6} cm is of the order of the the typical radius of neutron stars, the probe used in this test. This implies that the true value of β is most likely much smaller than 10{sup 11} cm{sup 2}.

79 ASTRONOMY AND ASTROPHYSICS↗

Orbital Signature Analyzer (OSA): A spacecraft health/safety monitoring and analysis tool

Fixed or static limit sensing is employed in control centers to ensure that spacecraft parameters remain within a nominal range. However, many critical parameters, such as power system telemetry, are time-varying and, as such, their 'nominal' range is necessarily time-varying as well. Predicted data, manual limits checking, and widened limit-checking ranges are often employed in an attempt to monitor these parameters without generating excessive limits violations. Generating predicted data and manual limits checking are both resource intensive, while broadening limit ranges for time-varying parameters is clearly inadequate to detect all but catastrophic problems. OSA provides a low-cost solution by using analytically selected data as a reference upon which to base its limits. These limits are always defined relative to the time-varying reference data, rather than as fixed upper and lower limits. In effect, OSA provides individual limits tailored to each value throughout all the data. A side benefit of using relative limits is that they automatically adjust to new reference data. In addition, OSA provides a wealth of analytical by-products in its execution.

Weaver, Steven↗

Spectral zone selection methodology for pebble bed reactors

A methodology is developed for determining boundaries of spectral zones for pebble bed reactors. A spectral zone is defined as a region made up of a number of nodes whose characteristics are collectively similar and that are assigned the same few-group diffusion constants. The spectral zones are selected in such a manner that the difference (error) between the reference transport solution and the diffusion code solution takes a minimum value. This is achieved by choosing spectral zones through optimally minimizing this error. The objective function for the optimization algorithm is the total reaction rate error, which is defined as the sum of the leakage, absorption and fission reaction rates errors in each zone. The selection of these spectral zones is such that the core calculation results based on diffusion theory are within an acceptable tolerance as compared to a proper transport reference solution. Through this work, a consistent approach for identifying spectral zones that yield more accurate diffusion results is introduced.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Precision of Property Measurements with Reference Molten Salts

Thermochemical and thermophysical properties of reference molten salt systems are being measured to establish the precisions achievable with current state-of-the-art methods including repeatability within a laboratory and reproducibility between laboratories using the same and different methods. Several laboratories across the United States are analyzing salt samples from single source batches of two salts to provide independent measurements of property values and the precisions of different measurement techniques in an interlaboratory study referred to as the Interlaboratory Salt Study (ISS). The compositions of the two salts produced for the study were reported to be eutectic LiF-NaF-KF (46.5-11.5-42 mol %) and NaCl-KCl (50-50 mol %). These salts are referred to herein as ISS FLiNaK and ISS NaCl-KCl. Thermochemical properties being measured at Argonne include thermal transitions and heat capacity by differential scanning calorimetry. Thermophysical properties being measured at Argonne include liquid density and surface tension by using a buoyancy densitometer and thermal diffusivity by using a laser flash analyzer. Thermal conductivity is calculated from measured thermal diffusivity, density and heat capacity values. The results of property measurements made at Argonne using these inter-laboratory salt study salts are presented here.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

LIP: The Livermore Interpolation Package, Version 1.3

This report describes LIP, the Livermore Interpolation Package. Because LIP is a stand-alone version of the interpolation package in the Livermore Equation of State (LEOS) access library, the initials LIP alternatively stand for the ''LEOS Interpolation Package''. LIP was totally rewritten from the package described in [1]. In particular, the independent variables are now referred to as x and y, since the package need not be restricted to equation of state data, which uses variables {rho} (density) and T (temperature). LIP is primarily concerned with the interpolation of two-dimensional data on a rectangular mesh. The interpolation methods provided include piecewise bilinear, reduced (12-term) bicubic, and bicubic Hermite (biherm). There is a monotonicity-preserving variant of the latter, known as bimond. For historical reasons, there is also a biquadratic interpolator, but this option is not recommended for general use. A birational method was added at version 1.3. In addition to direct interpolation of two-dimensional data, LIP includes a facility for inverse interpolation (at present, only in the second independent variable). For completeness, however, the package also supports a compatible one-dimensional interpolation capability. Parametric interpolation of points on a two-dimensional curve can be accomplished by treating the components as a pair of one-dimensional functions with a common independent variable. LIP has an object-oriented design, but it is implemented in ANSI Standard C for efficiency and compatibility with existing applications. First, a ''LIP interpolation object'' is created and initialized with the data to be interpolated. Then the interpolation coefficients for the selected method are computed and added to the object. Since version 1.1, LIP has options to instead estimate derivative values or merely store data in the object. (These are referred to as ''partial setup'' options.) It is then possible to pass the object to functions that interpolate or invert the interpolant at an arbitrary number of points. The first section of this report describes the overall design of the package, including both forward and inverse interpolation. Sections 2-6 describe each interpolation method in detail. The software that implements this design is summarized function-by-function in Section 7. For a complete example of package usage, refer to Section 8. The report concludes with a few brief notes on possible software enhancements. For guidance on adding other functional forms to LIP, refer to Appendix B. The reader who is primarily interested in using LIP to solve a problem should skim Section 1, then skip to Sections 7.1-4. Finally, jump ahead to Section 8 and study the example. The remaining sections can be referred to in case more details are desired. Changes since version 1.1 of this document include the new Section 3.2.1 that discusses derivative estimation and new Section 6 that discusses the birational interpolation method. Section numbers following the latter have been modified accordingly.

97 MATHEMATICS AND COMPUTING↗

LIP: The Livermore Interpolation Package, Version 1.4

This report describes LIP, the Livermore Interpolation Package. Because LIP is a stand-alone version of the interpolation package in the Livermore Equation of State (LEOS) access library, the initials LIP alternatively stand for the 'LEOS Interpolation Package'. LIP was totally rewritten from the package described in [1]. In particular, the independent variables are now referred to as x and y, since the package need not be restricted to equation of state data, which uses variables {rho} (density) and T (temperature). LIP is primarily concerned with the interpolation of two-dimensional data on a rectangular mesh. The interpolation methods provided include piecewise bilinear, reduced (12-term) bicubic, and bicubic Hermite (biherm). There is a monotonicity-preserving variant of the latter, known as bimond. For historical reasons, there is also a biquadratic interpolator, but this option is not recommended for general use. A birational method was added at version 1.3. In addition to direct interpolation of two-dimensional data, LIP includes a facility for inverse interpolation (at present, only in the second independent variable). For completeness, however, the package also supports a compatible one-dimensional interpolation capability. Parametric interpolation of points on a two-dimensional curve can be accomplished by treating the components as a pair of one-dimensional functions with a common independent variable. LIP has an object-oriented design, but it is implemented in ANSI Standard C for efficiency and compatibility with existing applications. First, a 'LIP interpolation object' is created and initialized with the data to be interpolated. Then the interpolation coefficients for the selected method are computed and added to the object. Since version 1.1, LIP has options to instead estimate derivative values or merely store data in the object. (These are referred to as 'partial setup' options.) It is then possible to pass the object to functions that interpolate or invert the interpolant at an arbitrary number of points. The first section of this report describes the overall design of the package, including both forward and inverse interpolation. Sections 2-6 describe each interpolation method in detail. The software that implements this design is summarized function-by-function in Section 7. For a complete example of package usage, refer to Section 8. The report concludes with a few brief notes on possible software enhancements. For guidance on adding other functional forms to LIP, refer to Appendix B. The reader who is primarily interested in using LIP to solve a problem should skim Section 1, then skip to Sections 7.1-4. Finally, jump ahead to Section 8 and study the example. The remaining sections can be referred to in case more details are desired. Changes since version 1.1 of this document include the new Section 3.2.1 that discusses derivative estimation and new Section 6 that discusses the birational interpolation method. Section numbers following the latter have been modified accordingly.

97 MATHEMATICS AND COMPUTING↗

THE SPECIFIC ACCELERATION RATE IN LOOP-STRUCTURED SOLAR FLARES-IMPLICATIONS FOR ELECTRON ACCELERATION MODELS

We analyze electron flux maps based on RHESSI hard X-ray imaging spectroscopy data for a number of extended coronal-loop flare events. For each event, we determine the variation of the characteristic loop length L with electron energy E, and we fit this observed behavior with models that incorporate an extended acceleration region and an exterior 'propagation' region, and which may include collisional modification of the accelerated electron spectrum inside the acceleration region. The models are characterized by two parameters: the plasma density n in, and the longitudinal extent L{sub 0} of, the acceleration region. Determination of the best-fit values of these parameters permits inference of the volume that encompasses the acceleration region and of the total number of particles within it. It is then straightforward to compute values for the emission filling factor and for the specific acceleration rate (electrons s{sup -1} per ambient electron above a chosen reference energy). For the 24 events studied, the range of inferred filling factors is consistent with a value of unity. The inferred mean value of the specific acceleration rate above E{sub 0} = 20 keV is {approx}10{sup -2} s{sup -1}, with a 1{sigma} spread of about a half-order-of-magnitude above and below this value. We compare these values with the predictions of several models, including acceleration by large-scale, weak (sub-Dreicer) fields, by strong (super-Dreicer) electric fields in a reconnecting current sheet, and by stochastic acceleration processes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗