Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Radiation detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

Development of mining guidance and control systems

New fundamental interface sensor concepts were identified and investigated including tabulation of the physical and performance characteristics of two new interface detector concepts: - natural background radiation and magnetic spin resonance. Studies of guidance and control techniques for the longwall miner identified three basic systems for use in automated/remote controlled longwall mining. The following projects were initiated: system study which will more completely define the longwall guidance and control system design concepts; integration of the various control functions (vertical, yaw, and roll); and hardware technical requirements.

Source record↗

Prototype Ge:Ga detectors for the NASA-Ames cooled grating spectrometer

The detectors were fabricated from a Ge:Ga wafer from Eagle-Pitcher with a room temperature resistivity of approx. 12ohms cm. The wafer is approximately 2 inches in diameter and 0.061 inches thick. The contact material was ion implanted with Boron using 10 to the 14th power ions/sq cm at 25 Kev and 2 x10 to the 14th power ions/sq cm at 50 Kev. The crystal was then sputter-cleaned and metallized first with sputtered Ti and then sputter Au. In addition to the usual infrared measurements of responsivity and noise, measurements were made of the detectors' response to ionizing radiation.

Houck, J. R.↗

Use of the VAS water vapor imagery to analyze upper-level flow patterns

Infrared (IR) channels which are available and are developed for operational use were examined. The Visible Infrared Spin-Scan Radiometer (VISSR) Atmospheric Sounder (VAS) was launched. This instrument has a radiometer consisting of the standard visible channel detectors and six thermal detectors that detect IR radiation in 12 spectral bands. Any one of the 11 new IR channels can be substituted for the standard 11.5 micro m window channel when the satellite is operating in the standard VISSP mode and provides data in image form through the GOES distribution system.

Anderson, R. K.↗

A mercuric detector system for X-ray astronomy. 2. Results from flight tests of a balloon borne instrument

To establish the expected sensitivity of a new hard X-ray telescope design, an experiment was conducted to measure the background counting rate at balloon altitudes (40 km) of mercuric iodide, a room temperature solid state X-ray detector. The prototype detector consisted of two thin mercuric iodide (HgI2) detectors surrounded by a large bismuth germanate (Bi4Ge3O12) scintillator operated in anticoincidence. The bismuth germanate shield vetoed most of the background counting rate induced by atmospheric gamma-rays, neutrons and cosmic rays. A balloon-borne gondola containing a prototype detector assembly was designed, constructed and flown twice in the spring of 1982 from Palestine, Texas. The second flight of this instrument established a differential background counting rate of 4.2 O.7 x 10-5 counts/sec cm keV over the energy range of 40 to 80 keV. This measurement was within 50% of the predicted value. The measured rate is approx 5 times lower than previously achieved in shielded NaI/CsI or Ge systems operating in the same energy range. The prediction was based on a Monte Carlo simulation of the detector assembly in the radiation environment at float altitude.

Vallerga, J.↗

Use of VAS multispectral data for sea surface temperature determination

The Visible Infrared Spin Scan Radiometer Atmospheric Sounder (VAS) is a radiometer possessing eight visible channel detectors and six thermal detectors that sense infrared radiation in 12 spectral bands. Housed in the GOES satellite, VAS spins in a west to east direction at 100 rpm and achieves spatial coverage at resolutions of 1 km in the visible and 7 or 14 km in the infrared by stepping a scan mirror in a north to south direction. Designed for multipurpose applications, the VAS can be operated in two different modes: (1) a multi-spectral imaging (MSI) mode, and (2) a dwell sounding (DS) mode. The MSI mode of operation is used for sea surface temperature (SST) determination. Currently, a full-disk MSI image for SST determination is received every hour, 18 hours a day during weekdays. This MSI mode of operation for SST consists of data obtained from wavelengths centered at 3.9 microns (channel 12), 11.6 microns (channel 8), and 12.6 microns (channel 7) as well as visible data.

Bates, J.↗

Radiative cryogenic cooler for Thematic Mapper

This paper reports on the development of a two-stage radiative cooler for infrared detectors designed to operate in polar, sun-synchronous, low-earth orbit. Novelty is evident in three areas of the design; radiator/shield geometry, contamination protection, and provision for detector cooling in ambient air. An overview of the design is presented along with the results of thermal, structural and contamination control tests.

Cafferty, T. T.↗

Absolute measurement of the extreme UV solar flux

A windowless rare-gas ionization chamber has been developed to measure the absolute value of the solar extreme UV flux in the 50-575-A region. Successful results were obtained on a solar-pointing sounding rocket. The ionization chamber, operated in total absorption, is an inherently stable absolute detector of ionizing UV radiation and was designed to be independent of effects from secondary ionization and gas effusion. The net error of the measurement is + or - 7.3 percent, which is primarily due to residual outgassing in the instrument, other errors such as multiple ionization, photoelectron collection, and extrapolation to the zero atmospheric optical depth being small in comparison. For the day of the flight, Aug. 10, 1982, the solar irradiance (50-575 A), normalized to unit solar distance, was found to be 5.71 + or - 0.42 x 10 to the 10th photons per sq cm sec.

Carlson, R. W.↗

A mercuric iodide detector system for X-ray astronomy. I - Design considerations and predictions of background and sensitivity

Since the discovery of Sco X-1 initiated X-ray astronomy in 1962, this science has progressed in connection with the placement of X-ray photon detectors above the atmosphere by means of rockets, balloons, and satellites. In the last few years, studies have been conducted regarding the use of mercuric iodide (HgI2) as room temperature X-ray detector for applications in hard X-ray astronomy. These detectors combine a high quantum efficiency with good energy resolution. The sensitivity of an astronomical X-ray telescope is discussed, and a description is presented of a specific design accepted for the HDXT to be flown on Spacelab. Attention is given to predictions of the background counting rate of the detector assembly in this design, taking into account the results of a Monte Carlo simulation of the detector assembly in the radiation environment at balloon altitudes (40 km).

Ricker, G. R.↗

Infrared radiometric technique in temperature measurement

One class of commercially available imaging infrared radiometers using cooled detectors is sensitive to radiation over the 3 to 12 micron wavelength band. Spectral filters can tailor instrument sensitivity to specific regions where the target exhibits optimum radiance. The broadband spectral response coupled with real time two-dimensional imaging and emittance/background temperature corrections make the instruments useful for remote measurement of surface temperatures from -20 C to +1500 C. Commonly used radiometric techniques and assumptions are discussed, and performance specifications for a typical modern commercial instrument are presented. The potential usefulness of an imaging infrared radiometer in space laboratories is highlighted through examples of research, nondestructive evaluation, safety, and routine maintenance applications. Future improvements in instrument design and application of the radiometric technique are discussed.

Glazer, S.↗

Visible and infrared mapping spectrometer (VIMS) - A facility instrument for planetary missions

A second-generation visible and IR mapping spectrometer (VIMS), selected for both the Mars Observer and Comet Rendezvous Asteroid Flyby (CRAF) missions, is described. VIMS is a scanning spectrometer with a focal plane consisting of linear arrays of visible and IR detectors, cooled by a radiative cooler. It is noted that a wide-angle scan using a full-aperture scan mirror was implemented for the Mars Observer; a narrow-angle scan using a scanning secondary mirror within a Cassegrain foreoptic was achieved for the CRAF mission.

Wellman, John B.↗

Radiation damage in scientific charge-coupled devices

Radiation damage is reported on CCDs (charge-coupled devices) that have been primarily exposed to 1.25-MeV gamma rays (Co-60 source). Two important classes of radiation damage are discussed, namely, bulk and ionization effects. Bulk damage or displacement damage is a process in which silicon atoms are displaced from their normal lattice positions by high-energy photons or particles. Single atomic displacements or cluster defect damage is produced, depending on the energy and type of radiation experienced by the detector. Bulk damage creates trapping sites within the CCD's signal channel which in turn degrades charge-transfer efficiency.

Janesick, James↗

Ga:Ge array development

Work at the University of Arizona and at Lawrence Berkeley Laboratory on the development of a far infrared array camera for the Multiband Imaging Photometer on the Space Infrared Telescope Facility (SIRTF) is discussed. The camera design uses stacked linear arrays of Ge:Ga photoconductors to make a full two-dimensional array. Initial results from a 1 x 16 array using a thermally isolated J-FET readout are presented. Dark currents below 300 electrons s(exp -1) and readout noises of 60 electrons were attained. Operation of these types of detectors in an ionizing radiation environment are discussed. Results of radiation testing using both low energy gamma rays and protons are given. Work on advanced C-MOS cascode readouts that promise lower temperature operation and higher levels of performance than the current J-FET based devices is described.

Young, Erick T.↗

Laboratory characterization of direct readout Si:Sb and Si:Ga infrared detector arrays

Highlights of recent results obtained at Ames Research Center in performance evaluations of infrared detector arrays are presented. Antimony- and gallium-doped silicon direct readout 58x62 element hybrid devices from Ames' ongoing detector technology development program are described. The observed characteristics meet most of the performance goals specified by the Space Infrared Telescope Facility (SIRTF) instrument teams and compare favorably with the best performance reported for discrete non-integrating extrinsic silicon detectors. Initial results of radiation environment testing are reported, and non-ideal behavior demonstrated by these test devices is discussed.

Mckelvey, Mark E.↗

Where two frontiers meet

Current research projects conducted at the JPL Center for Space Microelectronics Technology are briefly reviewed. These include the development of a new miniature tunneling Goday cell that can be made into arrays. This tunneling IR detector is sensitive to radiation through the infrared and is particularly suited to room temperature measurements of the mid to far infrared. Other developments include ballistic-electron-emission microscopy, a next-generation spacecraft on-board computer using the Direct Memory Access Co-Processor, a 1-sq cm custom chip with 40,000 transistors, new neural network chips, the third-generation hypercube, and a new Hyperswitch Adaptive Message routing VLSI chip.

Kukkonen, Carl↗

Broadband millimeter-wave GaAs transmitters and receivers using planar bow-tie antennas

We report broadband monolithic transmitters and receivers IC's for mm-wave electromagnetic measurements. The IC's use nonlinear transmission lines (NLTL) and sampling circuits as picosecond pulse generators and detectors. The pulses are radiated and received by planar monolithic bow-tie antennas, collimated with silicon substrate lenses and off-axis parabolic reflectors. Through Fourier transformation of the received pulse, 30-250 GHz free space gain-frequency measurements are demonstrated with an accuracy approximately = 0.17 dB, RMS.

Konishi, Y.↗

Nimbus-7 Earth radiation budget calibration history. Part 2: The Earth flux channels

Nine years (November 1978 to October 1987) of Nimbus-7 Earth radiation budget (ERB) products have shown that the global annual mean emitted longwave, absorbed shortwave, and net radiation were constant to within about + 0.5 W/sq m. Further, most of the small annual variations in the emitted longwave have been shown to be real. To obtain this measurement accuracy, the wide-field-of-view (WFOV) Earth-viewing channels 12 (0.2 to over 50 micrometers), 13 (0.2 to 3.8 micrometers), and 14 (0.7 to 2.8 micrometers) have been characterized in their satellite environment to account for signal variations not considered in the prelaunch calibration equations. Calibration adjustments have been derived for (1) extraterrestrial radiation incident on the detectors, (2) long-term degradation of the sensors, and (3) thermal perturbations within the ERB instrument. The first item is important in all the channels; the second, mainly in channels 13 and 14, and the third, only in channels 13 and 14. The Sun is used as a stable calibration source to monitor the long-term degradation of the various channels. Channel 12, which is reasonably stable to both thermal perturbations and sensor degradation, is used as a reference and calibration transfer agent for the drifting sensitivities of the filtered channels 13 and 14. Redundant calibration procedures were utilized. Laboratory studies complemented analyses of the satellite data. Two nearly independent models were derived to account for the thermal perturbations in channels 13 and 14. The global annual mean terrestrial shortwave and longwave signals proved stable enough to act as secondary calibration sources. Instantaneous measurements may still, at times, be in error by as much as a few Wm(exp -2), but the long-term averages are stable to within a fraction of a Wm(exp -2).

Kyle, H. Lee↗

Linear Energy Transfer (LET) spectra of cosmic radiation in low Earth orbit

Integral linear energy transfer (LET) spectra of cosmic radiation (CR) particles were measured on five Cosmos series spacecraft in low Earth orbit (LEO). Particular emphasis is placed on results of the Cosmos 1887 biosatellite which carried a set of joint U.S.S.R.-U.S.A. radiation experiments involving passive detectors that included thermoluminescent detectors (TLD's), plastic nuclear track detectors (PNTD's), fission foils, nuclear photo-emulsions, etc. which were located both inside and outside the spacecraft. Measured LET spectra are compared with those theoretically calculated. Results show that there is some dependence of LET spectra on orbital parameters. The results are used to estimate the CR quality factor (QF) for the COSMOS 1887 mission.

Parnell, T. A.↗

A new Fabry-Perot spectrometer for observations of diffuse near-infrared line emission

We describe a new Fabry-Perot spectrometer that is optimized for the detection of extended, low-surface-brightness line emission from 1.4 to 2.4 microns. The instrument combines high throughput and high sensitivity, yet limits the background radiation falling on the detector. The instrument has a single 20 sec - 200 sec beam and a resolving power lambda/delta(lambda) approximately 2500. The system is background shot-noise limited in the K window and limited by a combination of read noise, dark-current shot noise, and fluctuations in the OH airglow lines in the H window. We present sample data of some of the lowest-surface-brightness H2 line emission in the near infrared obtained to date.

Luhman, M. L.↗