Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Radiation Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

An infrared heterodyne radiometer for high-resolution measurements of solar radiation and atmospheric transmission

A tunable, Dicke-switched, infrared heterodyne radiometer (IHR) has been designed, fabricated, tested, and used to observe solar radiation and determine the atmospheric transmissivity in the 9-11-micron spectral band. The IHR provides a spectral resolution of 0.0067 reciprocal cm, a minimum detectable power level of 2.9 times ten to the minus twenty-third power W/Hz, and a temperature resolution of less than 1 K for a source temperature of 1000 K, an IF predetection bandwidth of 100 MHz, and an integration time of 30 s. Detailed design equations and measured IHR performance are presented. The IHR was used to make solar and atmospheric transmission measurements, and a vertical-path atmospheric attenuation of 2.3 dB has been established under favorable weather conditions. The attenuation of solar radiation due to cloud cover and haze has also been investigated.

Peyton, B. J.↗

Effects of radiation damage and precipitate distribution on micro-pillar compression testing of irradiated CuCrZr

The results of small-scale mechanical tests are convoluted by the so-called size effect, whereby materials appear stronger when the scale of the test is reduced to the order of microns or less. The dimensional range over which this occurs has been shown to be linked to a change in sample microstructure, such as the addition of defects induced by irradiation. To investigate this response, a CuCrZr alloy was subjected to proton irradiation and mechanically tested using micro compression of pillars with a range in size. It was found that irradiation defects dominate over the extrinsic size effect and the sensitivity to differences in precipitate microstructure was also somewhat reduced, suggesting that size-independent results could be obtained from much smaller test volumes in irradiated material compared to their non-irradiated counterparts. Lastly, comparison was made between the increase in yield strength predicted by models and the experimentally measured values to establish the key parameters driving the strengthening behaviour.

36 MATERIALS SCIENCE↗

Laser wavelength dependence of laser imprint

In laser direct-drive inertial confinement fusion, laser imprint is one of the major causes of degradation in target performance through its seeding of hydrodynamic instabilities. Early experiments and simulations have shown that laser imprint could be mitigated with a longer laser wavelength because of its lower critical density and longer conduction zone. Building upon this work, we explore a scenario where the laser wavelength during the picket pulse differs from that of the main pulse in order to gain the benefit of reduced imprint, while avoiding losses in drive coupling efficiency or an increase in laser-plasma instabilities. A series of 2D radiation-hydrodynamic simulations, which test three different laser wavelengths for the picket pulse, has been performed, where the intensity of the picket pulse is adjusted in order to maintain the same implosion adiabat. A detailed analysis of the growth of the mass density modulations at the ablation front over a large range of mode numbers confirms that the laser imprint can be mitigated with a picket pulse operating at a longer wavelength than the main pulse because of the longer conduction zone and enhanced thermal smoothing. The amplitude of the ablation front modulations is found to be lower for all mode numbers, which reduces the seeding of the Rayleigh–Taylor instability without affecting the mode growth rates.

Fourier analysis↗

Dynamics of magnetic evaporative beamline cooling for the preparation of cold atomic beams

The most sensitive direct neutrino mass searches today are based on measurement of the end point of the 𝛽 spectrum of tritium to infer limits on the mass of the unobserved neutrino. To avoid the smearing associated with the distribution of molecular final states in the T-He molecule, the next generation of these experiments will need to employ atomic (T) rather than molecular (T 2 ) tritium sources, at currents of at least 10 15 atoms per second. Following production, atomic T can be trapped in gravitational and/or magnetic bottles for 𝛽 spectrum experiments, if and only if it can first be cooled to millikelvin temperatures. Accomplishing this cooling presents substantial technological challenges. The Project 8 collaboration is developing a technique based on magnetic evaporative cooling along a beamline (MECB) for the purpose of cooling T to feed a magnetogravitational trap that also serves as a cyclotron radiation emission spectroscope. Initial tests of the approach are planned in a pathfinder apparatus using atomic Li. Here, this paper presents a method for analyzing the dynamics of the MECB technique and applies these calculations to the design of systems for cooling and slowing of atomic Li and T. A scheme is outlined that could provide a current of T at the millikelvin temperatures required for the Project 8 neutrino mass search.

atom optics↗

Engineered Solutions Group's SMR Containment Cable and Electrical Penetration Assembly System

GAIN Project CRADA Number NFE-21-08839, entitled “SMR Containment Cable and EPA System” was initiated by the partnership of Oak Ridge National Laboratory (ORNL) and Engineered Solutions Group (ESG) to test an ESG-designed Electrical Penetration Assembly and Containment Cabling System Qualified for not only legacy LWR designs, but also Small Modular Reactors designs currently being designed by several different suppliers. This project was undertaken to fill the equipment gap of EPA and Cabling Systems that require much more severe environmental requirements than legacy plant applications present due to their smaller containment volumes that result in high energy densities compared to legacy designs. This high energy density results in severe accident environments and more severe normal operating conditions as well. We developed two approaches to qualify Electrical Penetration Assembly (EPA) and Containment Cabling Systems for SMRs and Advanced Reactors. We take into consideration the more severe environmental parameters found with SMR designs. The system will need to meet a qualification test program addressing wear/cyclic aging, potential radiation exposure, thermal aging, vibration aging, thermal cycling, seismic qualification, electrical fault testing (per IEEE 317) and accident simulation. The equipment must meet the requirements of 10CFR50.49, GDC 50 in 10CFR50 Appendix A, and 10CFR50 Appendix J. NRC Regulatory Guides (RGs) identify an acceptable way of meeting regulatory requirements. RGs frequently endorse a standard for meeting these requirements. Specific to this review, equipment would be qualified in accordance with the following IEEE Standards. • IEEE 317-2013 (Electrical Penetration Assemblies), which is endorsed by RG 1.63, Rev. 3, • IEEE 323-2003 and the more current IEC/IEEE 60780-323 (Environmental Qualification of 1E Equipment) which is endorsed by RG 1.89. IEEE 323-2003 is endorsed by RG 1.209, • IEEE 344-2020 (Seismic Qualification. The 2013 version endorsed by RG 1.100, Rev. 4, with exceptions), • IEEE 383-2015 (Electrical Cables) (which is endorsed by RG 1.189 Rev. 4 and the -2003 version endorsed by RG 1.211 rev. 0), • IEEE 572-2019 (Electrical Connectors and Assemblies), which is endorsed by 1.156 Rev 1, and • [IEEE 1202 (endorsed by RG 1.189) would normally be applicable but the advanced cable designs are impervious to this cable flame test.] The primary goal of such a program is to provide an EPA design that can meet the qualification requirements for all legacy light water reactor plants currently operating as well as new plant designs including light water Small Modular Reactors. Thus, these requirements are applicable to plants licensed under 10CFR50 and 10CFR52. Other reactor designs may be evaluated, and this test system and qualification method applied to those applications if the requirements would satisfy the requirements of the intended plant. A secondary benefit of this work is to document some of the history and background in these requirements as there have been recent delays in an SMR licensing process due to NRC Requests for Additional Information in this subject matter area.

42 ENGINEERING↗

Deformation Behavior of β Phase in a WE54 Magnesium Alloy

Second phases play a significant role in the development of high-performance magnesium alloys with rare earth elements. Here, in situ tensile tests combined with synchrotron radiation were carried out to investigate the deformation behavior of β phases in a WE (Mg–Y–Gd–Nd) alloy. By lattice strain analysis, it was found that micro load continuously transferred from the soft α-Mg matrix to the hard β phases during the whole plastic deformation, while this behavior was much more obvious at the beginning of deformation. Based on diffraction peak broadening, Williamson–Hall (W–H) plotting was used to study the microstrain of β phases. The results showed that the microstrain of β phases increased rapidly within 4% plastic strain and reached the maximum at plastic strain of ~6.5%. Since the β phases acted as hard phases, the microstrain was considered as a sign of the stress concentration near phase interfaces. It was also suggested that the effective release of local stress concentration at the β/α-Mg interface benefited the ductility of the WE alloy by the plastic deformation of β phases and phase interface sliding.

36 MATERIALS SCIENCE↗

Microwave Radiometer: Meteorological Temperature Profiler (raw)

The microwave radiometer profiler (MWRP) provides vertical profiles of temperature, humidity, and cloud liquid water content as a function of height or pressure at approximately 5-minute intervals for nearly all weather conditions. The profiles are derived from measurements of absolute microwave radiances (expressed as "brightness temperatures") obtained at 12 frequencies in the range of 22-30 GHz and 51-59 GHz. The data are useful for input to numerical weather forecast models and others that require continuous, high-temporal-resolution profiles. The microwave radiance measurements are useful for testing models of microwave radiation transfer used to derive the profiles.

54 ENVIRONMENTAL SCIENCES↗

Correlation of irradiation data using activation fluences and irradiation temperature.

A new method of correlating radiation damage data is tested using actual measured data taken from the open literature. This method, the activation fluence method, was found to be as accurate as other contemporary models with which it was compared. The new method also has several advantages over the other methods. The method employs a new entity, the activation fluence (time-integrated specific activation rate), as the independent variables in a regression model. Temperature at which the irradiation takes place is also a variable. Although the method was tested for a specific type of damage (change in nil-ductility transition temperature for A302-B steel) it has no inherent restrictions and is limited only by the imagination of the user.

Lynch, J. H.↗

Safety monitoring system for radioisotope thermoelectric generators

System alerts personnel of hazards which may develop while they are performing tests on radioisotope thermoelectric generator (RTG). Remedial action is initiated to minimize damage. Five operating conditions are monitored: hot junction temperature, cold junction temperature, thermal shroud coolant flow, vacuum in test chamber, and alpha radiation.

Zoltan, A.↗

Long term spectral irradiance measurements of a 1000-watt xenon arc lamp

Spectral irradiance measurements over the range of 200 to 1060 nm were made on a 1000-watt xenon arc lamp over a period of 1500 hours. Four sets of measurements were made after periods of 70, 525, 1000, and 1500 hours of operation. The lamp (Hanovia Compact Xenon Arc Lamp) was mounted in the NASA Solar Irradiation System. When used in the System, the lamp is used as the radiating source for six test stations. Measurements were made of both the longterm stability (or variation of spectral irradiance as a function of time) and the actual spectral irradiance incident on the test specimen.

Schneider, W. E.↗

Jupiter's radiation belts

Fluxes of electrons and protons in Jupiter's radiation belts are calculated with the source (radial diffusion inward from the solar wind) and the loss (synchroton radiation). The calculations are tested against the measured radio-wave wavelength distribution, the radio-wave distribution with distance from Jupiter, and the degree of polarization of the radio waves. The Fokker-Planck equation is solved by using the method of Farley and Walt (1971) with the fixed flux at the outer boundary and the zero flux at Jupiter's surface. It is found, in agreement with Brice and McDonough (1973), Jacques and Davis (1973), and Birmingham et al. (1974), that the usual magnetic and electric diffusions, which vary as L to the 10th power and L to the 6th power, respectively, are insufficient to furnish the required electrons and that the diffusion driven by ionospheric winds of Brice and McDonough is strong enough to furnish Jupiter's belts. An additional loss mechanism close to Jupiter is required to remove the electrons, particularly those at low energies.

Stansberry, K. G.↗