Exploitation of Geometric Occlusion and Covariance Spectroscopy in a Gamma Sensor Array

The National Security Technologies, LLC, Remote Sensing Laboratory has recently used an array of six small-footprint (1-inch diameter by 3-inch long) cylindrical crystals of thallium-doped sodium iodide scintillators to obtain angular information from discrete gamma ray–emitting point sources. Obtaining angular information in a near-field measurement for a field-deployed gamma sensor is a requirement for radiological emergency work. Three of the sensors sit at the vertices of a 2-inch isosceles triangle, while the other three sit on the circumference of a 3-inch-radius circle centered in this triangle. This configuration exploits occlusion of sensors, correlation from Compton scattering within a detector array, and covariance spectroscopy, a spectral coincidence technique. Careful placement and orientation of individual detectors with reference to other detectors in an array can provide improved angular resolution for determining the source position by occlusion mechanism. By evaluating the values of, and the uncertainties in, the photopeak areas, efficiencies, branching ratio, peak area correction factors, and the correlations between these quantities, one can determine the precise activity of a particular radioisotope from a mixture of radioisotopes that have overlapping photopeaks that are ordinarily hard to deconvolve. The spectral coincidence technique, often known as covariance spectroscopy, examines the correlations and fluctuations in data that contain valuable information about radiation sources, transport media, and detection systems. Covariance spectroscopy enhances radionuclide identification techniques, provides directional information, and makes weaker gamma-ray emission—normally undetectable by common spectroscopic analysis—detectable. A series of experimental results using the concept of covariance spectroscopy are presented.

occlusion, covariance spectroscopy, correlations, ↗

Initial Computational Study of a New Multi-Hole Hohlraum (the "Midraum")

Existing cylindrical hohlraums with two oppositely positioned laser entrance holes (LEHs) have multiple constraints. Their goal is to produce radiation sources distributed over the sky, as visible from the spherical implosion capsule, with most of the deposition near the zeroes of the fourth Legendre polynomial in cosine of the polar angle. This requires some of the laser light to propagate across the hohlraum to positions near the hohlraum symmetry plane. The ratio of case spherical radius to capsule spherical radius should exceed 3 so that the light doesn’t pass through over-dense ablator plasma. Radiation transport can smooth higher radiation modes. For capsules that demand long pulse lengths, hohlraum walls can blow in and change the position where light is absorbed. This changes the radiation symmetry in a time dependent fashion. This affects both P2 and P4. This wall motion can be reduced by introducing fill gas into the hohlraum. The gas provides back pressure and tamps the wall motion. Adding the fill gas comes at some cost. It leads to increased absorption of laser light along the path. The fill gas adds heat capacity to the system, ultimately requiring more laser energy to meet the radiation flux goals, both in total and particularly in the amount of radiation coming from the vicinity of the capsule waist. Given the existing beam pointing at NIF energy from the outer beams must be transferred into the inner beams. Cross beam energy transport (CBET) is accomplished via a plasma instability. This transfer is not perfectly predictable. In addition, the higher intensity required to make up for the losses along the long path can lead to stimulated backscatter as well as the generation of suprathermal electrons. The inner beams will pass through the plasma ablated from the capsule toward the end of the pulse. Heating this plasma acts as another parasitic loss. In addition, the light passing through the turbulent blow-off can be refracted in unpredictable directions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optimization of Crew Shielding Requirement in Reactor-Powered Lunar Surface Missions

On the surface of the moon and not only during heightened solar activities the radiation environment is such that crew protection will be required for missions lasting in excess of six months. This study focuses on estimating the optimized crew shielding requirement for lunar surface missions with a nuclear option. Simple, transport-simulation based dose-depth relations of the three radiation sources (galactic, solar, and fission) are employed in a one-dimensional optimization scheme. The scheme is developed to estimate the total required mass of lunar regolith separating reactor from crew. The scheme was applied to both solar maximum and minimum conditions. It is shown that savings of up to 30% in regolith mass can be realized. It is argued, however, that inherent variation and uncertainty mainly in lunar regolith attenuation properties in addition to the radiation quality factor can easily defeat this and similar optimization schemes.

Barghouty, A. F.↗

RADIATIVE PROPERTY MEASUREMENTS OF OXY-FUEL FLAMES

As part of the DOE Existing Plants, Emissions and Capture (EPEC) program, oxy-combustion is being investigated as a method to simplify carbon capture and reduce the parasitic energy penalties associated with separating CO2 from a dilute flue gas. Gas-phase radiation heat transfer in boilers becomes significant when shifting from air-firing to oxycombustion, and must be accurately represented in models. Currently, radiative property data are not widely available in the literature for conditions appropriate to this environment. In order to facilitate the development and validation of accurate oxy-combustion models, NETL conducted a series of studies to measure radiation properties of oxy-fuel flames at adiabatic flame temperatures of 1750 - 1950K, and product molar concentrations ranging from 95% CO2 to 100% steam, determined by equilibrium calculations. Transmission coefficients were measured as a function of wavelength using a mid-IR imaging spectrometer and a blackbody radiation source. Additionally, flame temperatures were calculated using data collected within CO2 and H2O absorption bands. Experimental results were compared to two statistical narrowband models and experimental data from literature sources. These comparisons showed good overall agreement, although differences between the models and experimental results were noted, particularly for the R branch of the 2.7 μm H2O band.

54 ENVIRONMENTAL SCIENCES↗

Mock gravity and the cosmic structure

The process of generating large-scale cosmic structure from the radiation-pressure or 'mock gravity' instability is studied with particular emphasis on the implications of the Berkeley-Nagoya rocket data for the submillimeter background. The linear theory of perturbations in an absorbing medium embedded in an expanding universe of radiation sources is presented. The instability sets up collapse velocities in linear perturbation theory which far exceed those from gravitational instability, so growth continues even after the instability switches off. Perturbation due to this effect is analyzed and related to the growth of large-scale cosmic structures at recent times; large-scale structure is shown to evolve very little from 1 + z about 5 to the present. Nonlinear small-scale effects of the instability are analyzed; it is shown that radiation pressure would compress gas into small, dense pressure-confined clouds with tau much greater than one.

Hogan, Craig J.↗

Inter- and Intra-Chromosomal Aberrations in Human Cells Exposed in vitro to Space-like Radiations

Energetic heavy ions pose a great health risk to astronauts in extended ISS and future exploration missions. High-LET heavy ions are particularly effective in causing various biological effects, including cell inactivation, genetic mutations and cancer induction. Most of these biological endpoints are closely related to chromosomal damage, which can be utilized as a biomarker for radiation insults. Previously, we had studied chromosome aberrations in human lymphocytes and fibroblasts induced by both low- and high-LET radiation using FISH and multicolor fluorescence in situ hybridization (mFISH) techniques. In this study, we exposed human cells in vitro to gamma rays and energetic particles of varying types and energies and dose rates, and analyzed chromosomal damages using the multicolor banding in situ hybridization (mBAND) procedure. Confluent human epithelial cells and lymphocytes were exposed to energetic heavy ions at NASA Space Radiation Laboratory (NSRL) at the Brookhaven National Laboratory (Upton, NY) or Cs-137 gamma radiation source at the Baylor College (Houston, TX). After colcemid and Calyculin A treatment, cells were fixed and painted with XCyte3 mBAND kit (MetaSystems) and chromosome aberrations were analyzed with mBAND analysis system (MetaSystems). With this technique, individually painted chromosomal bands on one chromosome allowed the identification of interchromosomal aberrations (translocation to unpainted chromosomes) and intrachromosomal aberrations (inversions and deletions within a single painted chromosome). The possible relationship between the frequency of inter- and intra-chromosomal exchanges and the track structure of radiation is discussed. The work was supported by the NASA Space Radiation Health Program.

Hada, Megumi↗

Solid-State Photomultiplier Development for Radiation Detection

We are pursuing the sensitivity of back-thinned silicon (BT Si) with the gain of an SSPM (Baker 2011). Working in collaboration with Radiation Monitoring Devices, Inc., we are designing and fabricating prototype devices. Our original idea spurred from hybrid designs of advanced image sensors that use the sensitivity of BT Si that is then bump bonded to a CMOS readout device. As shown in the graph below (right), the BT Si has a far superior quantum efficiency (QE) than the standard photocathode response available in photomultiplier tubes (PMTs). Collecting as many scintillation photons as possible is the first objective. There has been major concern that the prototype could not deliver the ~105 electronic gain of a PMT. However, recently developed SSPMs do provide the electronic gain needed. We are now pursuing the design of a BTSSPM. With a smaller footprint, the SSPM can potentially lead to a simple, compact deployment package. Because the SSPM can be pixelated and tiled, we foresee developing an imaging detector. Pinhole imaging of radiation sources is a well-exercised technology. Our implementation of the coded aperture (Marks 2010) imager provides a high throughput pinhole imager. We intend to apply miniature coded apertures to minimal pixel count SSPMs to evaluate image quality.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Further spectrophotometry of the transient X-ray source A0620-00

Observations of the transient X-ray source A0620-00 in November 1976 show that the optical object had an apparent visual magnitude of 18.35. The spectrum is cool and shows that one component of the light comes from a K5 V to K7 V star. The distance is estimated to be 870 pc if the cool star is normal. Some support for the 7.8-day X-ray period recently found is provided by observations made in 1975 during the outburst. In addition to the cool K star, there is a second radiation source which has a flat spectrum. This source can be modeled by a 10,000-K blackbody with a radius (if spherical) of 17,000 km plus a 4000-K blackbody with a radius of 13,400 km and is probably a residual accretion disk. It is very unlikely that the K star can fill its Roche lobe, so that mass transfer to a neutron-star companion by this mechanism is unlikely. It is possible that the K star is losing mass by processes such as those that occur in T Tauri stars.

Oke, J. B.↗

An Effective Purification Process for the Nuclear Radiation Detector Tl 6 SeI 4

The semiconductor Tl6SeI4 was previously identified as a promising semiconductor for room temperature nuclear radiation detection. As the detection performance and carrier transport strongly depend on the concentration of impurity energy levels acting as scattering centers and carrier trapping, material purification is a crucial prerequisite step to obtain spectroscopic-grade detector performance. In this contribution, we present a highly efficient purification method using a bent ampule for evaporating Se, Tl2Se, and TlI precursors for Tl6Se4. On the basis of impurity analysis performed by glow discharge mass spectroscopy, the main impurities in Tl2Se were identified to be Pb, Bi, and Al, while in TlI the main impurities are Al and Sn. The bent-ampule method successfully reduces or removes the Cl, Pb, and Te impurities from the Se precursor, the Pb, Bi, and Al impurities from the Tl2Se precursor, and removes Sn from TU. Informed by the analysis results, density functional theory calculations were performed to study the identified impurities and related defects. The calculation results show that Bi and Al act as deep defect levels, which can be detrimental to the detector performance of Tl6SeI4. If the growth condition of Tl6SeI4 is Tl-rich/Se-poor, impurity of Si can introduce deep donors. However, it becomes electrically benign if growth conditions are Tl-poor/Se-rich, while Sn and Pb impurities are shallow donors. Centimeter-size Tl6SeI4 crystals were grown by the two-zone vertical Bridgman method using the purified precursors. The detector made of Tl6SeI4 crystal maintains the high resistivity on the order of 10(11) Omega.cm after purification, ideal for suppressing leakage current. The detector exhibits both full-energy and Tl escape photopeaks upon 122 keV gamma-ray from Co-57 radiation source. The electron mobility-lifetime product mu(e)tau(e) for TI6SeI4 detector is 8.1 X 10(-5) cm(2).V-1. On the basis of the carrier rise time measured from output pulses induced by 5.5 MeV alpha-particles from Am-241, the electron and hole mobilities were estimated to be 112 +/- 22 and 81 +/- 16 cm(2).V-1.s(-1), respectively, comparable to those of the leading detector materials HgI2 and TlBr. These results validate the potential of this compound for hard radiation detection, and the impurity analysis presented here allows future efforts to focus on reducing the concentration of the identified impurities.

Lin, Wenwen (ORCID:0000000216279558)↗

Scaling of Radiation Parameters of Planar and Compact Cylindrical Wire Arrays at the 1 MA Zebra Generator

Analysis is presented on scaling of radiated x-ray power, energy and implosion timing of single planar wire arrays (SPWA), double planar wire array (DPWA), and compact cylindrical wire array (CCWA) loads (diameter is 3 and 6 mm) of Mo and W with respect to current peak (0.8-1.4 MA), mass and array dimensions at 100 ns current pulse. Such scaling investigations are important for understanding the potential of these loads as an ICF radiation source{sup 7}. These data are used to identify promising directions to pursue with regard to highest x-ray output, smallest load size, and most consistent shot-to-shot performance. It is shown that W SPWA and DPWA total energy yield and peak power increased near-quadratically with current. DPWA scans of inter-planar gaps from 1.5 mm to 9 mm show an output maximum at 1.5 mm with decreasing output for 6 mm and 9 mm. A DPWA width scan shows that radiation yields decrease slowly as the width is decreased, which may allow for more compact loads without significant sacrifice to the output radiation. A mass scan of several W loads show that the implosion timing increases with mass.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Real-time observation of coherent acoustic phonons generated by an acoustically mismatched optoacoustic transducer using x-ray diffraction

The spectrum of laser-generated acoustic phonons in indium antimonide coated with a thin nickel film has been studied using time-resolved x-ray diffraction. Strain pulses that can be considered to be built up from coherent phonons were generated in the nickel film by absorption of short laser pulses. Acoustic reflections at the Ni–InSb interface leads to interference that strongly modifies the resulting phonon spectrum. The study was performed with high momentum transfer resolution together with high time resolution. This was achieved by using a third-generation synchrotron radiation source that provided a high-brightness beam and an ultrafast x-ray streak camera to obtain a temporal resolution of 10 ps. We also carried out simulations, using commercial finite element software packages and on-line dynamic diffraction tools. Using these tools, it is possible to calculate the time-resolved x-ray reflectivity from these complicated strain shapes. The acoustic pulses have a peak strain amplitude close to 1%, and we investigated the possibility to use this device as an x-ray switch. At a bright source optimized for hard x-ray generation, the low reflectivity may be an acceptable trade-off to obtain a pulse duration that is more than an order of magnitude shorter.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Bremsstrahlung {gamma}-ray generation by electrons from gas jets irradiated by laser pulses for radiographic testing

Electron generation from a gas jet irradiated by low energy femtosecond laser pulses is studied experimentally as a promising source of radiation for radioisotope-free {gamma}-ray imaging systems. The calculated yield of {gamma}-rays in the 0.5-2 MeV range, produced by low-average-power lasers and gas targets, exceeds the yields from solid tape targets up to 60 times. In addition, an effect of quasi-mono energetic electrons on {gamma}-ray imaging is also discussed.

07 ISOTOPE AND RADIATION SOURCES↗

Proton irradiation on materials

A computer code is developed by utilizing a radiation transport code developed at NASA Langley Research Center to study the proton radiation effects on materials which have potential application in NASA's future space missions. The code covers the proton energy from 0.01 Mev to 100 Gev and is sufficient for energetic protons encountered in both low earth and geosynchronous orbits. With some modification, the code can be extended for particles heavier than proton as the radiation source. The code is capable of calculating the range, stopping power, exit energy, energy deposition coefficients, dose, and cumulative dose along the path of the proton in a target material. The target material can be any combination of the elements with atomic number ranging from 1 to 92, or any compound with known chemical composition. The generated cross section for a material is stored and is reused in future to save computer time. This information can be utilized to calculate the proton dose a material would receive in an orbit when the radiation environment is known. It can also be used to determine, in the laboratory, the parameters such as beam current of proton and irradiation time to attain the desired dosage for accelerated ground testing of any material. It is hoped that the present work be extended to include polymeric and composite materials which are prime candidates for use as coating, electronic components, and structure building. It is also desirable to determine, for ground testing these materials, the laboratory parameters in order to simulate the dose they would receive in space environments. A sample print-out for water subject to 1.5 Mev proton is included as a reference.

Chang, C. Ken↗

A broadband gamma-ray spectrometry using novel unfolding algorithms for characterization of laser wakefield-generated betatron radiation

We present a high-flux, broadband gamma-ray spectrometry capable of characterizing the betatron radiation spectrum over the photon energy range from 10 keV to 20 MeV with respect to the peak photon energy, spectral bandwidth, and unique discrimination from background radiations, using a differential filtering spectrometer and the unfolding procedure based on the Monte Carlo code GEANT4. These properties are experimentally verified by measuring betatron radiation from a cm-scale laser wakefield accelerator (LWFA) driven by a 1-PW laser, using a differential filtering spectrometer consisting of a 15-filter and image plate stack. The gamma-ray spectra were derived by unfolding the photostimulated luminescence (PSL) values recorded on the image plates, using the spectrometer response matrix modeled with the Monte Carlo code GEANT4. The accuracy of unfolded betatron radiation spectra was assessed by unfolding the test PSL data simulated with GEANT4, showing an ambiguity of less than 20% and clear discrimination from the background radiation with less than 10%. The spectral analysis of betatron radiation from laser wakefield-accelerated electron beams with energies up to 3 GeV revealed radiation spectra characterized by synchrotron radiation with the critical photon energy up to 7 MeV. The gamma-ray spectrometer and unfolding method presented here facilitate an in-depth understanding of betatron radiation from LWFA process and a novel radiation source of high-quality photon beams in the MeV regime.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Directionally Sensitive Silicon Radiation Sensor (VCELL)

Sensors are a mission critical element in many NASA programs and require some very unique properties such as small size, low power, high reliability, low weight. Low cost sensors offer the possibility of technology transfer to the public domain for commercial applications. One sensor application that is important to many NASA programs is the ability to point at a radiation source, such as the sun. Such sensors may be an integral part of the guidance and control systems in space platforms and in remote exploratory vehicles. Sun/solar pointing is also important for ground-based systems such as solar arrays. These systems are not required to be small and lightweight. However, if a sensor with a sun pointing capability was developed that is very small, rugged, lightweight and at the same time low cost, it certainly could be used in existing and perhaps many new ground based applications. The objective of the VCELL (Directionally Sensitive Silicon Radiation Sensor) research is to develop a new and very unique silicon based directionally sensitive radiation sensor which can be fabricated using conventional monolithic IC technologies and which will meet the above requirements. The proposed sensor is a novel silicon chip that is directionally sensitive to incident radiation, providing azimuth and elevation information on the incident radiation. The resulting sensor chip will be appropriate for integration into a silicon IC or useful in a hybrid structure to be interfaced with a standard IEEE 1451 bus interface IC to create an Intelligent Sensor. It is presently estimated that it will require about three man-years of effort to complete the VCELL research and development. This includes the optical, electrical, mechanical and silicon fabrication and testing as well as computer simulations and theoretical analysis and modeling including testing in simulated space environments. This report summarizes the sensor research completed this summer as part of the Summer Faculty Fellowship Program. The primary effort was focused on activity necessary to fabricate prototype sensor.

Koy B. Cook↗

Coherence Conversion for Optimized Resolution in Optical Measurements - Example of Femtosecond Time Resolution Using the Transverse Coherence of 100-Picosecond X-Rays

A way is proposed to obtain a femtosecond time resolution over a picosecond range in x-ray spectroscopic measurements where the light source and the detector are much slower than that. It is based on the invariance of the modulus of the Fourier transform to object translations. The method geometrically correlates time in the sample with x-ray amplitudes over a spatial coordinate, and then takes the optical Fourier transform through far-field diffraction. Thus, explicitly time-invariant intensities that encode the time evolution of the sample can be measured with a slow detector. This corresponds to a phase-space transformation that converts the transverse coherence to become effective in the longitudinal direction. Because synchrotron-radiation sources have highly anisotropic coherence properties with about $10^5$ longitudinal electromagnetic-field modes at 1 eV bandwidth, but only tens to hundreds transverse modes, coherence conversion can drastically improve the time resolution. Reconstruction of the femtosecond time evolution in the sample from the Fourier intensities is subject to a phase ambiguity that is well-known in crystallography. However, a way is presented to resolve it that is not available in that discipline. Finally, data from a demonstration experiment are presented. The same concept can be used to obtain attosecond time resolution with an x-ray free-electron laser.

Adams, Bernhard W.↗

Operation of a Free-Electron Laser from the Extreme Ultraviolet to the Water Window

We report results on the performance of a free-electron laser operating at a wavelength of 13.7 nm where unprecedented peak and average powers for a coherent extreme-ultraviolet radiation source have been measured. In the saturation regime, the peak energy approached 170 {micro}J for individual pulses, and the average energy per pulse reached 70 {micro}J. The pulse duration was in the region of 10 fs, and peak powers of 10 GW were achieved. At a pulse repetition frequency of 700 pulses per second, the average extreme-ultraviolet power reached 20mW. The output beam also contained a significant contribution from odd harmonics of approximately 0.6% and 0.03% for the 3rd (4.6 nm) and the 5th (2.75 nm) harmonics, respectively. At 2.75 nm the 5th harmonic of the radiation reaches deep into the water window, a wavelength range that is crucially important for the investigation of biological samples.

42 ENGINEERING↗