Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “REFRIGERATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

High performance heat exchangers for next generation hybrid cooler (CRADA NFE-19-07891 Final Report)

The evaporative cooling process has been successfully deployed in multiple energy conversion processes such as power generation, process cooling, heating, ventilation & cooling (HVAC), and commercial and industrial refrigeration. The heat exchanger is a very common yet extremely critical component of such systems. The device is important since the performance of the overall cooling system heavily relies on the thermal-hydraulic efficiency of the heat exchanger. The possible wet operation as evaporative cooling heat exchanger complicates the issue. Indeed, based on the hybrid nature of operation (fully dry, partially wet, fully wet) the efficiency can vary significantly and can cause performance variation for the whole system. Understanding the importance of the issue, Oak Ridge National Laboratory (Contractor) and Baltimore Aircoil Company (Participant) propose an activity focused on the analysis of the existing heat exchanger technology used in air and evaporative cooling processes and design, development and demonstration of a novel heat exchanger design based on porous materials. The potential candidates include metallic wire meshes and metal foams carefully designed for the proposed application. Prior research has indicated that these materials have great potential for deployment in thermal systems, particularly heat sinks and heat exchangers. It is expected that the successful completion of the project will lead to novel heat exchanger technology for hybrid systems (capable of dry and wet operation) by exploring newly emerging materials and their potential for heat transfer application. The overall goal is to develop a next generation heat exchanger technology which can be deployed in evaporative cooling systems. The impact of the such development is significant since, it will not only make the overall system highly efficient but will also, reduce the total refrigerant charge in the heat exchanger, a critical aspect for the deployment of refrigerants with lower Global Warming Potential (GWP).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High performance heat exchangers for next generation hybrid cooler (CRADA Final Report)

The evaporative cooling process has been successfully deployed in multiple energy conversion processes such as power generation, process cooling, heating, ventilation & cooling (HVAC), and commercial and industrial refrigeration. The heat exchanger is a very common yet extremely critical component of such systems. The device is important since the performance of the overall cooling system heavily relies on the thermal-hydraulic efficiency of the heat exchanger. The possible wet operation as evaporative cooling heat exchanger complicates the issue. Indeed, based on the hybrid nature of operation (fully dry, partially wet, fully wet) the efficiency can vary significantly and can cause performance variation for the whole system. Understanding the importance of the issue, Oak Ridge National Laboratory (Contractor) and Baltimore Aircoil Company (Participant) propose an activity focused on the analysis of the existing heat exchanger technology used in air and evaporative cooling processes and design, development and demonstration of a novel heat exchanger design based on porous materials. The potential candidates include metallic wire meshes and metal foams carefully designed for the proposed application. Prior research has indicated that these materials have great potential for deployment in thermal systems, particularly heat sinks and heat exchangers. It is expected that the successful completion of the project will lead to novel heat exchanger technology for hybrid systems (capable of dry and wet operation) by exploring newly emerging materials and their potential for heat transfer application. The overall goal is to develop a next generation heat exchanger technology which can be deployed in evaporative cooling systems. The impact of the such development is significant since, it will not only make the overall system highly efficient but will also, reduce the total refrigerant charge in the heat exchanger, a critical aspect for the deployment of refrigerants with lower Global Warming Potential (GWP).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Compressor is A Sensor (Final Report)

The performance of the heat pump system varies greatly depending on the refrigerant charge amount. Improving the refrigerant charge fault detection and diagnostics (FDD) method of vapor compression systems have the potential for increasing energy efficiency and reducing service cost. Previous studies to predict refrigerant charge amount are mostly empirical methods which require significant amount of experimental data for high accuracy. The primary goal of this research is to develop a charge fault detection method which requires only a few experimental data with high prediction accuracy.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Testing and Analysis of an Exergetically Efficient 4 K to 2 K Helium Heat Exchanger

Modern experimental nuclear physics programs that utilize advanced superconducting devices require refrigeration below the lambda temperature of helium (2.1768 K) and involve sub-atmospheric helium at some point in the process. They typically operate between 1.8 and 2.1 K (16 to 40 mbar) and can require refrigeration ranging from tens to thousands of watts. These processes are very energy intensive, requiring roughly 850 W/W even for large and well?designed refrigerators, though they can easily require much more. Adiabatic expansion of sub-cooled liquid helium to these sub-atmospheric pressures will result in a two-phase mixture with a large liquid to vapor density ratio. Since there are no practical expanders to handle this condition, a counter flow heat exchanger is used to cool the super-critical helium supply using the returning sub-atmospheric helium. Typically, the super-critical helium exiting this 4.5 K to 2-K counter flow heat exchanger is throttled across an expansion valve to a sub-atmospheric pressure. This is a substantial irreversibility, typically 13 percent of the enthalpy difference between the load supply and return. A significant process improvement is theoretically obtainable by handling the exergy loss across the expansion valve supplying the flow to the load in a simple but different manner. The exergy loss can be minimized by allowing the supply flow pressure to decrease to a sub-atmospheric pressure concurrent with heat exchange with the sub-atmospheric flow from the load. This dissertation work encompasses testing of a practical implementation using a Collin's type heat exchanger to investigate the overall performance, as well as, the optimum selections of independent process parameters and how this affects the heat exchanger size distribution. The thermodynamics of heat exchange with a significant pressure drop for a non-ideal fluid are investigated, in regards to an equivalent expansion efficiency pseudo-property, a practical process expansion efficiency equivalence and an overall 2-K system performance improvement expectation. Theoretically predicted optimum independent process parameters are compared to those measured.

Knudsen, Peter↗

Advanced Frost Sensor for HVAC Applications

Frost is a common problem in heating, ventilation, and air conditioning (HVAC) systems that can degrade their efficiencies, leading to excessive electricity consumption. Appropriate defrosting is therefore essential for heat pumps and refrigeration systems. However, these systems typically run the defrost cycle based on a predetermined time interval, a method that does not accurately identify the amount of frost and thus consume excessive electricity. To substantially improve defrosting initiation and termination, this paper describes development of a smart sensor based on a capacitive sensing technique that can quantify frost accumulation and difference between frost, ice, and water. The reported sensor adopts interdigitated comb electrodes and can be updated to a potential multifunctional sensor array for the enhancing identification of frost, ice, and water with the integrated measurement of surface temperature, frost capacitance, and resistance. The proposed frost sensor is potentially expected to have widespread applications in HVAC systems, including heat pumps, refrigerators, and commercial refrigeration systems.

Gao, Zhiming↗

Performance Enhancement of the Transcritical CO2 Cycle with a Near-Isothermal Liquid Piston Compression by an Ejector

This study investigates the use of an ejector in a transcritical CO2 cycle employing a near-isothermal liquid piston compressor, with the objective of mitigating refrigerant degassing in mineral oil. While the liquid piston compressor demonstrated high isothermal efficiency (˜90%), overall cycle performance was limited by CO2 degassing during chamber pressure fluctuations. A thermodynamic model was developed to compare baseline and ejector-assisted cycles, incorporating solubility correlations, entrainment ratio characteristics, and a degassing correction factor. Results indicate that the ejector increased suction pressure and reduced CO2–oil solubility variation, which improved refrigerant intake and reduced degassing losses. Despite these benefits, the ejector-assisted cycle showed a lower coefficient of performance (COP) than the baseline. Possible contributing factors include the limited marginal benefit of pressure reduction in a highly efficient isothermal compressor, reduced effectiveness of the separator due to the use of a suction-line heat exchanger in both cycles, and uncertainties in the solubility data under transient conditions. These findings suggest that degassing mitigation is essential for realizing the potential of liquid piston compression, but ejector integration alone is unlikely to enhance COP. Future work should focus on ejector optimization, improved oil–refrigerant management, introducing less-soluble working liquids, and experimental validation under realistic operating conditions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of absorption cycle for space station environmental control system application

The study to evaluate an absorption cycle refrigeration system to provide environmental control for the space stations is reported. A zero-gravity liquid/vapor separator was designed and tested. The results were used to design a light-weight, efficient generator for the absorption refrigeration system. It is concluded that absorption cycle refrigeration is feasible for providing space station environmental control.

Sims, W. H.↗

Development of a solar-powered residential air conditioner: Screening analysis

Screening analysis aimed at the definition of an optimum configuration of a Rankine cycle solar-powered air conditioner designed for residential application were conducted. Initial studies revealed that system performance and cost were extremely sensitive to condensing temperature and to the type of condenser used in the system. Consequently, the screening analyses were concerned with the generation of parametric design data for different condenser approaches; i. e., (1) an ambient air condenser, (2) a humidified ambient air condenser (3) an evaporative condenser, and (4) a water condenser (with a cooling tower). All systems feature a high performance turbocompressor and a single refrigerant (R-11) for the power and refrigeration loops. Data were obtained by computerized methods developed to permit system characterization over a broad range of operating and design conditions. The criteria used for comparison of the candidate system approaches were (1) overall system COP (refrigeration effect/solar heat input), (2) auxiliary electric power for fans and pumps, and (3) system installed cost or cost to the user.

Source record↗

Thermal control systems for low temperature Shuttle payloads

Greater sensitivity and longer life for future space sensor systems place more stringent demands on cooling system technology. Results are presented for a study designed to determine and evaluate low-temperature thermal control system concepts for various cooling categories in the range 3-200 K and to generate hardware development plans for undeveloped viable system concepts. The study considered Shuttle launched payloads in the 1980-1991 time frame, with 1-5 yr of life. Cooling concepts are categorized as open-cycle (expendable), closed-cycle (mechanical), solid-state, and radiative. Particular attention is given to the concepts of multistage heat pipe radiator, diode heat pipe radiator, and radiator guarded cryostat. Results are given for parametric analyses of the Vuilleumier refrigerator, the rotary reciprocating refrigerator, the solid hydrogen refrigerator, the solid hydrogen/multistage radiator hybrid cooler, and the magneto-Peltier hybrid cooler.

Wright, J. P.↗

Evaluation of a large capacity heat pump concept for active cooling of hypersonic aircraft structure

Results of engineering analyses assessing the conceptual feasibility of a large capacity heat pump for enhancing active cooling of hypersonic aircraft structure are presented. A unique heat pump arrangement which permits cooling the structure of a Mach 6 transport to aluminum temperatures without the aid of thermal shielding is described. The selected concept is compatible with the use of conventional refrigerants, with Freon R-11 selected as the preferred refrigerant. Condenser temperatures were limited to levels compatible with the use of conventional refrigerants by incorporating a unique multipass condenser design, which extracts mechanical energy from the hydrogen fuel, prior to each subsequent pass through the condenser. Results show that it is technically feasible to use a large capacity heat pump in lieu of external shielding. Additional analyses are required to optimally apply this concept.

Pagel, L. L.↗

Cryogenic cooling for spacecraft sensors, instruments, and experiments

Several disciplines requiring in-space cryogenic cooling are identified including high-energy, gamma-ray, and IR astronomy, relativity missions, and superconducting devices. Radiant coolers are limited in terms of temperature ranges and cooling loads. Other spacecraft cryogenic systems include stored solid cryogenic coolers using materials such as hydrogen, neon, argon, and methane. Two such cooler designs are described including one for the Nimbus F limb radiance inversion radiometer and one for the Nimbus G limb infrared monitoring of the atmosphere. Suggestions for increasing the performance of solid cryogenic coolers are made, such as a multimission cooler, a mechanical refrigerator, Stirling-cycle refrigerators, and Vuilleumier mechanized coolers. Techniques for obtaining cryogenic cooling in the milli-K range are identified as dilution refrigeration and adiabatic demagnetization.

Sherman, A.↗

Cryogenic cooling study for the advanced limb scanner

The cryogenic operating requirements for a VM refrigerator to be used for detector cooling of the advanced limb scanner (ALS) instrument are defined. Determination of these requirements include consideration of mission and environmental constraints. Based on the operating requirements a detailed refrigerator design and performance analysis is conducted resulting in an optimized VM refrigerator conceptual design. The cooler-instrument-spacecraft interfaces are evaluated resulting in recommendations as to the best approach and most effective concepts resulting in simple and satisfactory interfaces. A preliminary implementation plan and schedule describing the general tasks required to develop, design, manufacture, test, and deliver three VM coolers and required support equipment to support an ALS flight experiment are presented. The result of this effort shows that existing VM cooler technology is sufficient to satisfy ALS mission requirements and schedules.

Russo, S. C.↗

Production of 1.25 K He-4 without He-4 superfluid film

A refrigeration process is described which enables the production of a sub-gamma-point He-4 temperatures without the production of superfluid. The advantages of the process for zero gravity and low-noise refrigeration are described. The lowest temperature produced to date is 1.25 K. The process is also useful with other gases for refrigeration; the output temperature is selected by gas type.

Goebel, J. H.↗

Theory and tests of two-phase turbines

A theoretical model for two-phase turbines was developed. Apparatus was constructed for testing one- and two-stage turbines (using speed decrease from stage to stage). Turbines were tested with water and nitrogen mixtures and refrigerant 22. Nozzle efficiencies were 0.78 (measured) and 0.72 (theoretical) for water and nitrogen mixtures at a water/nitrogen mixture ratio of 68, by mass; and 0.89 (measured) and 0.84 (theoretical) for refrigerant 22 expanding from 0.02 quality to 0.28 quality. Blade efficiencies (shaft power before windage and bearing loss divided by nozzle jet power) were 0.63 (measured) and 0.71 (theoretical) for water and nitrogen mixtures and 0.62 (measured) and 0.63 (theoretical) for refrigerant 22 with a single stage turbine, and 0,70 (measured) and 0.85 (theoretical) for water and nitrogen mixtures with a two-stage turbine.

Elliott, D. G.↗

Computer program for analysis of split-Stirling-cycle cryogenic coolers

A computer program for predicting the detailed thermodynamic performance of split-Stirling-cycle refrigerators has been developed. The mathematical model includes the refrigerator cold head, free-displacer/regenerator, gas transfer line, and provision for modeling a mechanical or thermal compressor. To allow for dynamic processes (such as aerodynamic friction and heat transfer) temperature, pressure, and mass flow rate are varied by sub-dividing the refrigerator into an appropriate number of fluid and structural control volumes. Of special importance to modeling of cryogenic coolers is the inclusion of real gas properties, and allowance for variation of thermo-physical properties such as thermal conductivities, specific heats and viscosities, with temperature and/or pressure. The resulting model, therefore, comprehensively simulates the split-cycle cooler both spatially and temporally by reflecting the effects of dynamic processes and real material properties.

Brown, M. T.↗

Active cooling requirements for propellant storage

Recent NASA and DOD mission models have indicated future needs for orbital cryogenic storage and supply systems. Two thermal control systems which show the greatest promise for improving propellant storage life were evaluated. One system was an open cycle thermodynamic vent type with a refrigeration system for partial hydrogen reliquefaction located at the LH2 tank and a vapor cooled shield for integrated and non-integrated tank designs to reduce boiloff. The other was a closed system with direct refrigeration at the LH2 tank. A reversed Brayton cycle unit was baselined for the propellant processor. It is concluded that: (1) reliquefaction systems are not attractive for minimizing propellant boiloff; (2) open cycle systems may not be economically attractive for long term storage; (3) a number of refrigeration systems are available to assist in the long term storage of cryogenic propellants; and (4) shields can significantly improve the performance of mechanical coolers.

Klein, G. A.↗

Recent cryocooler progress in Japan

The progress of cryocoolers and related devices in Japan is reviewed. The Japanese National Railways has developed the light weight 4 K on-board refrigerators since 1977 as part of the MAGLEV train program. Superconducting and cryogenic fundamental technology was examined which included high performance cryocooler, magnetic refrigerator and superfluid refrigeration. Space cryogenics such as the cooling systems of IR-detectors was studied. Cryocooler for special applications such as cryopump, NMR-CT and JJ devices was investigated. Compact heat exchangers, high performance regenerators and reliable compressors are investigated as a critical component technology.

Matsubara, Y.↗

Dynamics insulation systems

Advanced dynamic insulation systems were analyzed from a thermodynamic point of view. A particular performance measure is proposed in order to characterize various insulations in a unique manner. This measure is related to a base quantity, the refrigeration power ratio. The latter is the minimum refrigeration power, for a particular dynamic insulation limit, to the actual reliquefaction power associated with cryoliquid boiloff. This ratio serves as reference quantity which is approximately constant for a specific ductless insulation at a chosen normal boiling point. Each real container with support structure, vent tube, and other transverse components requires a larger refrigeration power. The ratio of the actual experimental power to the theoretical value of the support-less system is a suitable measure of the entire insulation performance as far as parasitic heat leakage is concerned. The present characterization is illustrated using simple thermodynamic system examples including experiments with liquid nitrogen. Numerical values are presented and a comparison with liquid helium is given.

Chen, W. E. W.↗