Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RADIATION SOURCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

An analytical study of double bend achromat lattice

In a double bend achromat, Chasman-Green (CG) lattice represents the basic structure for low emittance synchrotron radiation sources. In the basic structure of CG lattice single focussing quadrupole (QF) magnet is used to form an achromat. In this paper, this CG lattice is discussed and an analytical relation is presented, showing the limitation of basic CG lattice to provide the theoretical minimum beam emittance in achromatic condition. To satisfy theoretical minimum beam emittance parameters, achromat having two, three, and four quadrupole structures is presented. In this structure, different arrangements of QF and defocusing quadruple (QD) are used. An analytical approach assuming quadrupoles as thin lenses has been followed for studying these structures. A study of Indus-2 lattice in which QF-QD-QF configuration in the achromat part has been adopted is also presented.

43 PARTICLE ACCELERATORS↗

Preface: High-pressure studies with x-rays

The study of matter at extreme conditions represents a forefront area of research activity across the sciences, including physics, chemistry, materials science, and even biology. Advancing the frontier of extreme conditions science requires powerful micro-sampling probes to access minute samples through the vessel walls and to separate weak sample signals from the background signals arising from the much more massive surrounding vessel materials. Here, the development of synchrotron radiation sources has provided the essential breakthrough in extreme conditions field.

47 OTHER INSTRUMENTATION↗

Chiral streamers

The interaction of time-varying electromagnetic fields and solid, liquid, and gaseous matter may lead to electrical breakdown phenomena through the excitation of ionization waves or streamers that control the dynamics of localized plasma propagation through the media. The streamers usually propagate along straight lines, either between random points in space or along a certain direction in a guided mode. Here, we report on a new type of plasma discharges with the regular helical propagation pattern driven by a pulsed dc voltage in nitrogen at sub-atmospheric-pressure conditions. The helical guided streamers, named chiral streamers or chi-streamers, are excited without any external magnetic fields, which commonly cause helical plasma motions. We also demonstrate a hybrid propagation mode involving the interchangeable chiral streamers and the straight-line propagating plasmas. High-speed, time-resolved optical imaging reveals that the chiral streamers and the hybrid patterns are made of spatially localized discrete plasma bullets, similar to the straight-line guided streamers. These results may enable effective control of propagation of confined plasmas and electromagnetic energy along pre-determined, potentially deterministic paths, which have important implications for the development of next-generation plasma-based radiation sources, communication devices, and medical treatments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental observation of sub-terahertz backward-wave amplification in a multi-level microfabricated slow-wave circuit

In our earlier paper dealing with dispersion retrieval from ultra-deep, reactive-ion-etched, slow-wave circuits on silicon substrates, it was proposed that splitting high-aspect-ratio circuits into multilevels enabled precise characterization in sub-terahertz frequency regime. This achievement prompted us to investigate beam-wave interaction through a vacuum-sealed integration with a 15-kV, 85-mA, thermionic, electron gun. Our experimental study demonstrates sub-terahertz, backward-wave amplification driven by an external oscillator. The measured output shows a frequency downshift, as well as power amplification, from beam loading even with low beam perveance. This offers a promising opportunity for the development of terahertz radiation sources, based on silicon technologies.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Beam emittance reduction during operation of Indus-2

Indus-2 storage ring is a 2.5 GeV third generation synchrotron radiation source. This source was commissioned using a moderate optics. Beam injection was accomplished using an off momentum electron beam to avoid difficulties faced in storage of beam at 550 MeV. The injection procedure and relevant beam dynamical studies are discussed. The switch over from the moderate optics to low emittance optics is done at 2.5 GeV after storing the electron beam. The procedure evolved to reduce the beam emittance and its implementation during the operation is discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Soft x-ray optical constants of sputtered chromium thin films with improved accuracy in the L and M absorption edge regions

In this paper, we determine with improved accuracy the complex index of refraction n = 1 - δ + iβ of sputtered chromium thin films for photon energies ranging from 25 eV to 813 eV. These data include the first absolute measurements of the absorption fine structure near the Cr-L edge. First, we verified by combining Rutherford Backscattering Spectrometry and grazing-incidence x-ray reflectometry that the sputtered thin films were pure Cr with a density consistent with tabulated values. Then, we demonstrated that the Cr surface oxide layer remains stable when the samples are exposed to air for up to 4 years. The Cr absorption coefficient β was determined from the transmittance of freestanding Cr thin films with various thicknesses, measured at the ALS synchrotron radiation source. A model is proposed to correct the transmittance data from the spectral contamination of the source. Finally, we used the new β values, combined with theoretical and tabulated data from the literature, in order to calculate the δ values by the Kramers-Kronig relation. The improvement in the accuracy of β values is demonstrated by the f-sum rule. Finally, an additional validation of the new Cr optical constants (δ, β) is performed by comparing the simulated and experimental reflectance of a Cr/B 4 C multilayer mirror near the Cr-L 2,3 edge.

36 MATERIALS SCIENCE↗

High-sensitivity plasma density retrieval in a common-path second-harmonic interferometer through simultaneous group and phase velocity measurement

Precise measurements of the plasma density in ionized gas cells and discharged capillaries are critical to the design and operation of plasma-based accelerators, active plasma lenses, and plasma-based radiation sources. In this manuscript, a spectral-domain common-path second-harmonic interferometer is upgraded with the simultaneous measurement of the group and phase velocity, allowing for high-sensitivity density characterization (from the phase velocity advance) without the need for phase tracking from zero-density (enabled by the group velocity delay). The technique is applied to 1.5-cm-long plasma structures, without density ambiguity in parameter scans with >2π phase jumps. Finally, the single-shot sensitivity in phase retrieval is demonstrated at 63 mrad, equivalent to a density-length product of 1.8·10 15 cm -2 . This is an improvement of ×45 compared to group velocity analysis alone.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Iron dopant energy levels in β-Ga 2 O 3

The energetic positions of the two Fe dopant levels in the bandgap of β-Ga 2 O 3 are determined to be at 3.05(±0.05) and 3.85(±0.05) eV below the conduction band minimum from transmission measurements employing a sub-picosecond tunable ultraviolet laser radiation source. A further measurement of the quantum efficiency of photoelectron emission from the Fe:Ga 2 O 3 (010) photocathode is consistent with the obtained absorption data and a dominant optical phonon assisted Franck–Condon emission mechanism, while also providing an estimate of 100 ps for the conduction band electron lifetime.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Quantification and visualization of uncertainties in reconstructed penumbral images of implosions at Omega

Penumbral imaging is a technique used in plasma diagnostics in which a radiation source shines through one or more large apertures onto a detector. To interpret a penumbral image, one must reconstruct it to recover the original source. The inferred source always has some error due to noise in the image and uncertainty in the instrument geometry. Interpreting the inferred source thus requires quantification of that inference’s uncertainty. Markov chain Monte Carlo algorithms have been used to quantify uncertainty for similar problems but have never been used for the inference of the shape of an image. Because of this, there are no commonly accepted ways of visualizing uncertainty in two-dimensional data. This paper demonstrates the application of the Hamiltonian Monte Carlo algorithm to the reconstruction of penumbral images of fusion implosions and presents ways to visualize the uncertainty in the reconstructed source. This methodology enables more rigorous analysis of penumbral images than has been done in the past.

Instruments & Instrumentation↗

Optical characteristics of a HgBr excilamp

Optical characteristics of a coaxial HgBr excilamp on multicomponent mercury dibromide vapour mixtures with helium, nitrogen and sulfur hexafluoride are investigated under pumping by a pulse-periodic barrier discharge. Stable excilamp operation was demonstrated at a pump pulse repetition rate of 3 – 9 kHz. The component composition of the working system was determined, which provides a maximal average and pulsed specific radiation power of 48.8 mW cm{sup -3} and 40.6 W cm{sup -3}, respectively, at the efficiency of 7.3 % in the blue-green spectral range with the maximal radiation intensity at the wavelength of 502 nm. The reduction in the radiation power after 2.5 × 10{sup 6} shots is 5 %. Interpretation is given for the results of optimisation of excilamp characteristics. (optical radiation sources)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Method of measuring blood oxygenation based on spectroscopy of diffusely scattered light

A new approach to the measurement of blood oxygenation is developed and implemented, based on an original two-step algorithm reconstructing the relative concentration of biological chromophores (haemoglobin, water, lipids) from the measured spectra of diffusely scattered light at different distances from the radiation source. The numerical experiments and approbation of the proposed approach using a biological phantom have shown the high accuracy of the reconstruction of optical properties of the object in question, as well as the possibility of correct calculation of the haemoglobin oxygenation in the presence of additive noises without calibration of the measuring device. The results of the experimental studies in animals agree with the previously published results obtained by other research groups and demonstrate the possibility of applying the developed method to the monitoring of blood oxygenation in tumour tissues. (paper)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Protein structural dynamics in solution unveiled via 100-ps time-resolved x-ray scattering

We have developed a time-resolved x-ray scattering diffractometer capable of probing structural dynamics of proteins in solution with 100-ps time resolution. This diffractometer, developed on the ID14B BioCARS (Consortium for Advanced Radiation Sources) beamline at the Advanced Photon Source, records x-ray scattering snapshots over a broad range of q spanning 0.02-2.5 {angstrom}{sup -1}, thereby providing simultaneous coverage of the small-angle x-ray scattering (SAXS) and wide-angle x-ray scattering (WAXS) regions. To demonstrate its capabilities, we have tracked structural changes in myoglobin as it undergoes a photolysis-induced transition from its carbon monoxy form (MbCO) to its deoxy form (Mb). Though the differences between the MbCO and Mb crystal structures are small (rmsd < 0.2 {angstrom}), time-resolved x-ray scattering differences recorded over 8 decades of time from 100 ps to 10 ms are rich in structure, illustrating the sensitivity of this technique. A strong, negative-going feature in the SAXS region appears promptly and corresponds to a sudden > 22 {angstrom}{sup 3} volume expansion of the protein. The ensuing conformational relaxation causes the protein to contract to a volume {approx}2 {angstrom}{sup 3} larger than MbCO within {approx}10 ns. On the timescale for CO escape from the primary docking site, another change in the SAXS/WAXS fingerprint appears, demonstrating sensitivity to the location of the dissociated CO. Global analysis of the SAXS/WAXS patterns recovered time-independent scattering fingerprints for four intermediate states of Mb. These SAXS/WAXS fingerprints provide stringent constraints for putative models of conformational states and structural transitions between them.

47 OTHER INSTRUMENTATION↗

Photoionisation of ions with synchrotron radiation: from ions in space to atoms in cages

Here, we introduce the photon-ion merged-beams technique for the photoionisation of mass/charge selected ionised atoms, molecules and clusters by x-rays from synchrotron radiation sources. Examples for photoionisation of atomic ions are discussed by going from outer shell ionisation of simple few electron systems to inner shell ionisation of complex many electron ions. Fundamental ionisation mechanisms are elucidated and the importance of the results for applications in astrophysics and plasma physics is pointed out. Finally, the unique capabilities of the photon-ion merged-beams technique for the study of photoabsorption by nanoparticles are demonstrated by the example of endohedral fullerene ions.

Schippers, Stefan↗

Shielding Analysis Capability of UNF-ST&DARDS

The Used Nuclear Fuel Storage, Transportation and Disposal Analysis Resource and Data System (UNF-ST&DARDS) is used to perform dose rate calculations for spent nuclear fuel (SNF) transportation packages based on the actual physical and nuclear characteristics (i.e., assembly design, burnup, initial enrichment, and cooling time) of the as-loaded SNF. Nuclear fuel data, transportation package model templates, and SNF canister loading map information residing within the tool facilitate automated generation of SCALE input files for radiation source term and dose rate calculations. Transportation package specific models developed for UNF-ST&DARDS dose rate analyses are described in detail. UNF-ST&DARDS dose rate analyses were performed in this paper for over 400 SNF canisters from 16 sites in their designated transportation casks. For simplicity, representative dose rate calculation results are presented as a function of time (i.e., selected calendar years between 2020 and 2100) for 73 SNF canisters in dry storage at four sites. For these canisters, the projected maximum dose rate values at 2 m from the lateral surfaces of the vehicle under normal conditions of transport (NCT) would vary between 1.9 and 11.5 mrem/h in 2020. Five SNF canisters will exceed the regulatory dose rate limit of 10 mrem/h at 2 m in 2020, and the analyzed SNF canisters will comply with regulatory dose rate limits by 2030. An analysis of the impact on the dose rate of fuel failure and reconfiguration during transportation indicated that the maximum dose rate for hypothetical accident conditions will be unaffected, and the NCT maximum dose rate at 2 m would have a maximum increase by a factor of 1.7 for a representative pressurized water reactor package and by a factor of 2.6 for a representative boiling water reactor package relative to intact fuel. Finally, analysis of the actual heat loading and the dose rate at 2 m from the lateral surface of the vehicle for the five SNF canisters exceeding the NCT regulatory dose rate limit of 10 mrem/h in 2020 showed that the dose rate could be more limiting with respect to regulatory requirements than the heat loading; i.e., the canister transportability date may be evaluated based on the transportation package’s external dose rate.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

SCALE Shielding Calculations for Advanced Reactor Accident Scenarios

The study results presented in this paper demonstrate the capabilities of the SCALE computer code for non–light water reactor (non-LWR) radiation source term and shielding calculations in support of the U.S. Nuclear Regulatory Commission non-LWR fuel cycle demonstration project. Representative non-LWR types, including the sodium-cooled fast reactor (SFR), the molten salt reactor (MSR), and the heat pipe microreactor (HPMR), were analyzed to evaluate dose rates associated with postulated accident scenarios (SFR and MSR), reactor operation (MSR and HPMR), and fuel self-protecting characteristics (HPMR). New features were implemented in SCALE depletion codes to better simulate MSR operation.

MSR↗

Advances in high-resolution RIXS for the study of excitation spectra under high pressure

Hard x-ray resonant inelastic x-ray scattering (RIXS) is a promising x-ray spectroscopic tool for measuring low-energy excitation spectra at high pressure which have been stymied heretofore by the technical difficulties inherent in measuring a sample held at high pressure in a diamond anvil cell. The currently available facilities of high resolution (< 200 meV) RIXS has been used to probe low-energy excitation spectra from the diamond anvil cell, by virtue of advanced photon detection instrumentations of high-brilliance synchrotron x-ray radiation sources. Compared to a structural elastic scattering and x-ray emission, RIXS is a photon hungry technique and high-resolution RIXS under high pressure is at its infancy stage. In this review, the fundamentals of RIXS including instrumentation of high-resolution RIXS are presented and then experimental details of diamond anvil cell, sample preparation and measurement geometry are discussed. Experimental data of 3d and 5d transition metal oxides are presented. Finally, future improvements in high-resolution RIXS instrumentation for the high pressure experiment is discussed.

electronic and magnetic excitations↗

A stochastic approach to quantifying the blur with uncertainty estimation for high-energy X-ray imaging systems

One of the primary causes of blur in a high-energy X-ray imaging system is the shape and extent of the radiation source, or ‘spot’. It is important to be able to quantify the size of the spot as it provides a lower bound on the recoverable resolution for a radiograph, and penumbral imaging methods – which involve the analysis of blur caused by a structured aperture – can be used to obtain the spot’s spatial profile. We present a Bayesian approach for estimating the spot shape that, unlike variational methods, is robust to the initial choice of parameters. The posterior is obtained from a normal likelihood, which was constructed from a weighted least squares approximation to a Poisson noise model, and prior assumptions that enforce both smoothness and non-negativity constraints. A Markov chain Monte Carlo algorithm is used to obtain samples from the target posterior, and the reconstruction and uncertainty estimates are the computed mean and variance of the samples, respectively. Lastly, synthetic data-sets are used to demonstrate accurate reconstruction, while real data taken with high-energy X-ray imaging systems are used to demonstrate applicability and feasibility.

97 MATHEMATICS AND COMPUTING↗

THE WIDE-FIELD INFRARED SURVEY EXPLORER (WISE): MISSION DESCRIPTION AND INITIAL ON-ORBIT PERFORMANCE

The all sky surveys done by the Palomar Observatory Schmidt, the European Southern Observatory Schmidt, and the United Kingdom Schmidt, the InfraRed Astronomical Satellite, and the Two Micron All Sky Survey have proven to be extremely useful tools for astronomy with value that lasts for decades. The Wide-field Infrared Survey Explorer (WISE) is mapping the whole sky following its launch on 2009 December 14. WISE began surveying the sky on 2010 January 14 and completed its first full coverage of the sky on July 17. The survey will continue to cover the sky a second time until the cryogen is exhausted (anticipated in 2010 November). WISE is achieving 5{sigma} point source sensitivities better than 0.08, 0.11, 1, and 6 mJy in unconfused regions on the ecliptic in bands centered at wavelengths of 3.4, 4.6, 12, and 22 {mu}m. Sensitivity improves toward the ecliptic poles due to denser coverage and lower zodiacal background. The angular resolution is 6.''1, 6.''4, 6.''5, and 12.''0 at 3.4, 4.6, 12, and 22 {mu}m, and the astrometric precision for high signal-to-noise sources is better than 0.''15.

79 ASTRONOMY AND ASTROPHYSICS↗