Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RADIATION SHIELDING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

Uncertainty analysis of axial temperature and Seebeck coefficient measurements

Experimental investigations of solid materials at elevated temperatures rely on the optimized thermal design of the measurement system, as radiation becomes a predominant source of heat loss which can lead to large uncertainty in measured temperature and related physical properties of a test sample. Advancements in surface temperature measurements have reduced thermal losses arising from the cold-finger effect using axially inserted thermocouples and from radiation using shields or other thermal guards. The leading technology for temperature sensing at temperatures up to ~900 °C makes use of these design features for measuring thermopower, yet uncertainty analysis estimation of this technique is not known. This study makes use of finite element modeling to determine spatial temperature distributions to obtain the upper limit of confidence expected for the axially inserted thermocouple approach when a heated radiation shield is incorporated into the design. Using an axially inserted thermocouple to measure the sample surface temperature, the temperature variations across the sample hot and cold surfaces at 900 °C for a temperature drop of 0, 5, and 10 °C are calculated to be as low as 0.02, 0.21, and 0.41 °C, respectively, when a heated radiation shield is employed. Uniform temperature distribution on the thermocouple cross-wire geometry indicates that the axial thermocouple measurement design is indeed effective for suppressing the cold-finger effect. Using a heated radiation shield is found to significantly reduce the temperature gradient across the thermocouples.

30 DIRECT ENERGY CONVERSION↗

Shielding and Build-up Considerations for Radiation Detection

Abstract -- Shielding for gamma radiation has traditionally focused on the reduction of dose effects. For these applications, reducing the energy of the radiation is important along with reducing the actual number of photons, and therefore large masses of high Z material are typically used. However, for measurements requiring low backgrounds or for detecting low activity signals, such as in homeland security applications, the primary use of shielding is to decrease the total number of background photons (perhaps in a region of interest), and therefore the processes of buildup and down scattering become important. In these applications, where the important measure is count rate instead of dose and low background are important, improved reduction in counts from background radiation may be achieved with specially designed configurations of thin layers of different materials instead of a single thick layer. This paper briefly describes recent modeling and experimental investigations in layered-shielding methodology and provides results with comparison to single shielding material such as Pb. Application of these techniques to some real world problems, such as detector systems for homeland security, is discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Mars Radiation Risk Assessment and Shielding Design for Long-term Exposure to Ionizing Space Radiation

NASA is now focused on the agency's vision for space exploration encompassing a broad range of human and robotic missions including missions to Moon, Mars and beyond. As a result, there is a focus on long duration space missions. NASA is committed to the safety of the missions and the crew, and there is an overwhelming emphasis on the reliability issues for space missions and the habitat. The cost-effective design of the spacecraft demands a very stringent requirement on the optimization process. Exposure from the hazards of severe space radiation in deep space and/or long duration missions is a critical design constraint and a potential 'show stopper'. Thus, protection from the hazards of severe space radiation is of paramount importance to the agency's vision. It is envisioned to have long duration human presence on the Moon for deep space exploration. The exposures from ionizing radiation - galactic cosmic radiation and solar particle events - and optimized shield design for a swing-by and a long duration Mars mission have been investigated. It is found that the technology of today is inadequate for safe human missions to Mars, and revolutionary technologies need to be developed for long duration and/or deep space missions. The study will provide a guideline for radiation exposure and protection for long duration missions and career astronauts and their safety.

Tripathi, Ram K.↗

Final Report on Radiation Measurements Performed Inside of the BEAM Module

Measurements of the radiation environment inside of the Bigelow Expandable Activity Module (BEAM) have been made on a pseudo-continuous basis since June 6, 2016 using both passive and active instrumentation. Passive detectors yield a single cumulative dose value (or average daily dose) over the measurement period from deploy to return to ground. Active Radiation Environment Monitor (REM) sensors yield dose rate, Linear Energy Transfer (LET) spectra, and particle-specific dose, all on a 1-minute cadence. From the initial install in 2016 until early 2018, BEAM was an empty module. In 2018, further testing was approved and stowage began to be moved into BEAM. As a result, it was decided to stop measurements with RAM detectors to avoid potential difficulties with access after stowage was added. The REM sensors remained however in the original deploy locations.

radiation exposure↗

Evaluation of Spacecraft Shielding Effectiveness for Radiation Protection

The potential for serious health risks from solar particle events (SPE) and galactic cosmic rays (GCR) is a critical issue in the NASA strategic plan for the Human Exploration and Development of Space (HEDS). The excess cost to protect against the GCR and SPE due to current uncertainties in radiation transmission properties and cancer biology could be exceedingly large based on the excess launch costs to shield against uncertainties. The development of advanced shielding concepts is an important risk mitigation area with the potential to significantly reduce risk below conventional mission designs. A key issue in spacecraft material selection is the understanding of nuclear reactions on the transmission properties of materials. High-energy nuclear particles undergo nuclear reactions in passing through materials and tissue altering their composition and producing new radiation types. Spacecraft and planetary habitat designers can utilize radiation transport codes to identify optimal materials for lowering exposures and to optimize spacecraft design to reduce astronaut exposures. To reach these objectives will require providing design engineers with accurate data bases and computationally efficient software for describing the transmission properties of space radiation in materials. Our program will reduce the uncertainty in the transmission properties of space radiation by improving the theoretical description of nuclear reactions and radiation transport, and provide accurate physical descriptions of the track structure of microscopic energy deposition.

Cucinotta, Francis A.↗

Radiation transmission data for radionuclides and materials relevant to brachytherapy facility shielding

To address the limited availability of radiation shielding data for brachytherapy as well as some disparity in existing data, Monte Carlo simulation was used to generate radiation transmission data for {sup 60}Co, {sup 137}Cs, {sup 198}Au, {sup 192}Ir, {sup 169}Yb, {sup 170}Tm, {sup 131}Cs, {sup 125}I, and {sup 103}Pd photons through concrete, stainless steel, lead, as well as lead glass and baryte concrete. Results accounting for the oblique incidence of radiation to the barrier, spectral variation with barrier thickness, and broad beam conditions in a realistic geometry are compared to corresponding data in the literature in terms of the half value layer (HVL) and tenth value layer (TVL) indices. It is also shown that radiation shielding calculations using HVL or TVL values could overestimate or underestimate the barrier thickness required to achieve a certain reduction in radiation transmission. This questions the use of HVL or TVL indices instead of the actual transmission data. Therefore, a three-parameter model is fitted to results of this work to facilitate accurate and simple radiation shielding calculations.

61 RADIATION PROTECTION AND DOSIMETRY↗

Assessment of neutron radiation damage and shielding for operational good practice of the video systems at Jet - 25426

High neutron and gamma ray yields in fusion reactors like JET can be detrimental to the applied diagnostic equipment such as video imaging systems. For instance, defects induced in semiconductors by neutrons via displacement damage effects degrade the performance of CCD image sensors. Actions to minimize and/or mitigate these effects need to be considered during operation and maintenance of the video system at JET. A preliminary study on the setting up of a neutron/gamma shield around the cameras has been pursued. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radiation dose and shielding for the space station

Significant differences in dose prediction for Space Station arise depending on whether or not the magnetic field model is extrapolated into the future. The basis for these calculations is examined in detail, and the importance of the residual atmospheric layer at altitudes below 1000 km, with respect to radiation attenuation, is emphasized. Dosimetry results from Shuttle flights are presented and compared with the computed results. It is recommended that, at this stage, no extrapolation of the magnetic field into the future be included in the calculations. A model adjustment, to replace this arbitrary procedure, is presented. Dose predictions indicate that, at altitudes below 500 km and at low inclination, and with nominal module wall thickness (0.125 in. aluminum), orbit stay times of 90 days in Space Station would result in quarterly radiation doses to the crew, which are well within present limits for both males and females. Countermeasures would be required for stay times of a year or more and the measure of increasing shielding is examined.

Mccormack, Percival D.↗

How Much Does Lead Shielding during Fluoroscopy Reduce Radiation Dose to Out-of-Field Body Parts?

Fluoroscopy technologists routinely place a lead shield between the x-ray table and the patient's gonads, even if the gonads are not directly in the x-ray field. Internal scatter radiation is the greatest source of radiation to out-of-field body parts, but a shield placed between the patient and the x-ray source will not block internal scatter. Prior nonfluoroscopy research has shown that there is a small reduction in radiation dose when shielding the leakage radiation that penetrates through the collimator shutters. The goal of this in vitro study was to determine if there was any radiation dose reduction when shielding leakage radiation during fluoroscopy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

In Vitro Studies on Space Radiation-Induced Delayed Genetic Responses: Shielding Effects

Understanding the radiation risks involved in spaceflight is of considerable importance, especially with the long-term occupation of ISS and the planned crewed exploration missions. Several independent causes may contribute to the overall risk to astronauts exposed to the complex space environment, such as exposure to GCR as well as SPES. Protons and high-Z energetic particles comprise the GCR spectrum and may exert considerable biological effects even at low fluence. There are also considerable uncertainties associated with secondary particle effects (e.g. HZE fragments, neutrons etc.). The interaction of protons and high-LET particles with biological materials at all levels of biological organization needs to be investigated fully in order to establish a scientific basis for risk assessment. The results of these types of investigation will foster the development of appropriately directed countermeasures. In this study, we compared the biological responses to proton irradiation presented to the target cells as a monoenergetic beam of particles of complex composition delivered to cells outside or inside a tissue phantom head placed in the United States EVA space suit helmet. Measurements of chromosome aberrations, apoptosis, and the induction of key proteins were made in bone marrow from CBA/CaJ and C57BL/6 mice at early and late times post exposure to radiation at 0, 0.5, 1 and 2 Gy while inside or outside of the helmet. The data showed that proton irradiation induced transmissible chromosomal/genomic instability in haematopoietic stem cells in both strains of mice under both irradiation conditions and especially at low doses. Although differences were noted between the mouse strains in the degree and kinetics of transforming growth factor-beta 1 and tumor necrosis factor-alpha secretion, there were no significant differences observed in the level of the induced instability under either radiation condition, or for both strains of mice. Consequently, when normalized to physical dose, the monoenergetic proton field present inside the helmet-protected phantom produced equivalent biological responses, when compared to unshielded cells, as measured by the induction of delayed genetic effects in murine haematopoietic stem cells.

Kadhim, Munira A.↗

Thermal, Radiation and Impact Protective Shields (TRIPS) for Robotic and Human Space Exploration Missions

New concepts for protective shields for NASA s Crew Exploration Vehicles (CEVs) and planetary probes offer improved mission safety and affordability. Hazards include radiation from cosmic rays and solar particle events, hypervelocity impacts from orbital debris/ micrometeorites, and the extreme heating environment experienced during entry into planetary atmospheres. The traditional approach for the design of protection systems for these hazards has been to create single-function shields, i.e. ablative and blanket-based heat shields for thermal protection systems (TPS), polymer or other low-molecular-weight materials for radiation shields, and multilayer, Whipple-type shields for protection from hypervelocity impacts. This paper introduces an approach for the development of a single, multifunctional protective shield, employing nanotechnology- based materials, to serve simultaneously as a TPS, an impact shield and as the first line of defense against radiation. The approach is first to choose low molecular weight ablative TPS materials, (existing and planned for development) and add functionalized carbon nanotubes. Together they provide both thermal and radiation (TR) shielding. Next, impact protection (IP) is furnished through a tough skin, consisting of hard, ceramic outer layers (to fracture the impactor) and sublayers of tough, nanostructured fabrics to contain the debris cloud from the impactor before it can penetrate the spacecraft s interior.

Loomis, M. P.↗

Optimized shielding for space radiation protection

Future deep space mission and International Space Station exposures will be dominated by the high-charge and -energy (HZE) ions of the Galactic Cosmic Rays (GCR). A few mammalian systems have been extensively tested over a broad range of ion types and energies. For example, C3H10T1/2 cells, V79 cells, and Harderian gland tumors have been described by various track-structure dependent response models. The attenuation of GCR induced biological effects depends strongly on the biological endpoint, response model used, and material composition. Optimization of space shielding is then driven by the nature of the response model and the transmission characteristics of the given material.

NASA Discipline Radiation Health↗

Optimized Shielding for Space Radiation Protection

Abstract. Future deep space mission and International Space Station exposures will be dominated by the high-charge and -energy (HZE) ions of the Galactic Cosmic Rays (GCR). A few mammalian systems have been extensively tested over a broad range of ion types and energies. For example, C3H10T1/2 cells, V79 cells, and Harderian gland tumors have been described by various track-structure dependent response models. The attenuation of GCR induced biological effects depends strongly on the biological endpoint, response model used, and material composition. Optimization of space shielding is then driven by the nature of the response model and the transmission characteristics of the given material.

Wilson, J. W.↗

Atomic and molecular hydrogen in the circumstellar envelopes of late-type stars

The distribution of atomic and molecular hydrogen in the expanding circumstellar envelopes of cool evolved stars is discussed. The main concern is to evaluate the effects of photodestruction of H2 by galactic UV radiation, including shielding of the radiation by H2 itself and by dust in the envelope. One of the most important parameters is the H/H2 ratio which is frozen out in the upper atmosphere of the star. For stars with photospheric temperatures greater than about 2500 K, atmospheric models suggest that the outflowing hydrogen is mainly atomic, whereas cooler stars should be substantially molecular. In the latter case, photodissociation of H2 and heavy molecules contribute to the atomic hydrogen content of the outer envelope. The presented estimates indicate that atomic hydrogen is almost at the limit of detection in the C-rich star IRC + 10216, and may be detectable in warmer stars. Failure to detect it would have important implications for the general understanding of circumstellar envelopes.

Glassgold, A. E.↗