Silicon-based three-dimensional microstructures for radiation dosimetry in hadrontherapy

In this work, we propose a solid-state-detector for use in radiation microdosimetry. This device improves the performance of existing dosimeters using customized 3D-cylindrical microstructures etched inside silicon. The microdosimeter consists of an array of micro-sensors that have 3D-cylindrical electrodes of 15 μm diameter and a depth of 5 μm within a silicon membrane, resulting in a well-defined micrometric radiation sensitive volume. These microdetectors have been characterized using an {sup 241}Am source to assess their performance as radiation detectors in a high-LET environment. This letter demonstrates the capability of this microdetector to be used to measure dose and LET in hadrontherapy centers for treatment plan verification as part of their patient-specific quality control program.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Latest Results on Radiation Tolerance of Diamond Detectors

At present most experiments at the CERN Large Hadron Collider (LHC) are planning upgrades in the next 5-10 years for their innermost tracking layers as well as luminosity monitors to be able to take data as the luminosity increases and CERN moves toward the High Luminosity-LHC (HL-LHC). These upgrades will most likely require more radiation tolerant technologies than exist today. As a result this is one area of intense research, and Chemical Vapour Deposition (CVD) diamond is one such technology. CVD diamond has been used extensively in beam condition monitors as the innermost detectors in the highest radiation areas of all LHC experiments. This talk describes the preliminary radiation tolerance measurements of the highest quality polycrystalline CVD material for a range of proton energies and neutrons obtained with this material with the goal of elucidating the issues that should be addressed for future diamond based detectors. The talk presents the evolution of various semiconductor parameters as a function of dose.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A simulation pipeline for fast neutron imaging and spectroscopy using quantified detector attributes

Radiation imaging capabilities, essential in the nuclear nonproliferation regime, facilitate source localization and, in certain cases, spectroscopy. Scatter-based neutron cameras, which can measure the neutron signatures from special nuclear material, hold particular interest. Systems incorporating organic scintillators can extract neutron energy spectra, potentially distinguishing fission neutron sources from others, such as alpha-neutron sources. The development and testing of a scatter-based neutron imager, however, can be challenging without having an accurate simulation model or first constructing a prototype. This work describes a simulation pipeline that takes output from MCNPX-PoliMi simulations and creates the expected back-projection neutron images and neutron energy spectra. This pipeline was developed to improve the modeling of fast neutron imagers and bridge the current gap in literature, which predominantly focuses on gamma-ray Compton imager models. This work also reports on the significance of various real-world system considerations and their effects on the simulated detector responses. The pipeline was verified and validated with experimental data collected using a 252 Cf spontaneous fission source using a fast neutron scattering imager developed at the University of Michigan.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Low background physics at the Kimballton Mine

The Kimballton Underground Research Facility (KURF) is home to several experiments. One consists to two HPGe detectors designed to screen candidate materials to be used in low-background experiments for radioactivity. Analysis techniques, including our efficiency calculations will be presented. We have also deployed a customized BEGe (Broad Energy Germanium) detector in a low-background cryostat. This paper will focus on the shield design, detector characteristics and measurements that can be performed with such a detector in a low-background environment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SNAP-8 post shutdown gamma radiation approximations

Detector responses were calculated for normalized sources in the Perkins and King energy group structure for a SNAP 8 power system on a NASA space station. Gamma decay rates were then calculated by using an expanded, updated list of isotopic decay data, and from these, actual detector responses were found for the SNAP 8 system. The results indicate that energy-dependent calculations must be made to determine decay gamma dose rates for actual reactor configurations. A simplified method for making these calculations has been devised.

Byrn, N. R.↗

Terahertz spectroscopy with a holographic Fourier transform spectrometer plus array detector using coherent synchrotron radiation

By use of coherent terahertz synchrotron radiation, we experimentally tested a holographic Fourier transform spectrometer coupled to an array detector to determine its viability as a spectral device. Somewhat surprisingly, the overall performance strongly depends on the absorptivity of the birefringent lithium tantalate pixels in the array detector.

43 PARTICLE ACCELERATORS↗

Radiation damage of the HEAO C-1 germanium detectors

The effects of radiation damage from proton bombardment of the four HEAO C-1 high purity germanium detectors have been measured and compared to predictions. Because of the presence of numerous gamma-ray lines in the detector background spectra and because of the relatively long exposure time of the HEAO 3 satellite to cosmic-ray and trapped protons, it has been possible to measure both the energy and time dependence of radiation damage. After 100 d in orbit, each of the four detectors has been exposed to approximately 3 x 10 to the 7th protons/sq cm, and the average energy resolution at 1460 keV had degraded from 3.2 keV fwhm to 8.6 keV fwhm. The lines were all broadened to the low energy side although the line profile was different for each of the four detectors. The damage-related contribution to the degradation in energy resolution was found to be linear in energy and proton influence.

Mahoney, W. A.↗

Variable-Temperature Cryostat For Radiation-Damage Testing Of Germanium Detectors

Variable-temperature cryostats developed to study radiation damage to, and annealing of, germanium gamma-ray detectors. Two styles: one accommodates large single detector and one accommodates two medium-sized detectors. New cryostats allow complete testing of large-volume germanium gamma-ray detectors without breaking cryostat vacuum and removing detectors for annealing.

Floyd, Samuel R.↗

Precision spectroscopy of light kaonic atom X-rays in the SIDDHARTA experiment

The KN system at rest makes a sensitive testing ground for low energy QCD. At the DA{Phi}NE electron-positron collider of Laboratori Nazionali di Frascati we study kaonic atoms, taking advantage of the low-energy kaons from {Phi}-mesons decaying nearly at rest. The DEAR (DA{Phi}NE Exotic Atom Research) experiment at LNF delivered the most precise data on kaonic hydrogen up to now. DEAR and its follow-up experiment SIDDHARTA (Silicon Drift Detector for Hadronic Atom Research by Timing Application) are using X-ray spectroscopy of kaonic atoms to measure the strong interaction induced shift and width of the ground state. SIDDHARTA is the first experiment on kaonic helium-3 and deuterium ever, and kaonic hydrogen was remeasured with improved precision.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Radiation Damage and Mitigation by Minority Carrier Injection in InAsSb/AlAsSb Heterojunction Barrier Mid-Wave Infrared Detector

Here, the effects of gamma and proton irradiation, and of forward bias minority carrier injection, on photo-response were investigated for InAsSb/AlAsSb pBn mid-wave infrared (MWIR) detectors with an engineered majority-carrier barrier. Room-temperature gamma irradiation had an insignificant effect on 77 K photo-response. Gamma irradiation at 77 K detector temperature, however, decreased in situ photo-response by 19% after a cumulative dose of ~ 500 krad(Si). Subsequent forward bias minority carrier injection had no effect on photo-response. The 77 K detectors irradiated with 30 MeV protons up to 2 Mrad(Si) had photo-response degraded by up to 70%, but here forward bias minority carrier (hole) injection caused up to 12% recovery that persisted more than 30 min. These results suggest a mitigation strategy for maintaining the photo-response of similar detectors in radiation environments that cause displacement damage defects.

36 MATERIALS SCIENCE↗

X-ray Emission from Electron Betatron Motion in a Laser-Plasma Accelerator

Single-shot x-ray spectra from electron bunches produced by a laser-plasma wakefield accelerator (LPA) were measured using a photon-counting single-shot pixelated Silicon-based detector [3], providing for the first time direct spectra without assumptions required by filter based techniques. In addition, the electron bunch source size was measured by imaging a wire target, demonstrating few micron source size and stability. X-rays are generated when trapped electrons oscillate in the focusing field of the wake trailing the driver laser pulse. In addition to improving understanding of bunch emittance and wake structure, this provides a broadband, synchronized femtosecond source of keV x-rays. Electron bunch spectra and divergence were measured simultaneously and preliminary analysis shows correlation between x-ray andelectron spectra. Bremsstrahlung background was managed using shielding and magnetic diversion.

43 PARTICLE ACCELERATORS↗

Compositions and methods for detecting radiation

Tensioned metastable fluid detectors are disclosed that minimize false positive detection events. The methods involve the use of new fluids that provide improved neutron-alpha fission detection at reduced tension states. The rate of spin is also increased using a new protocol that avoids the creation of liquid imbalances in the arms of a CTMFD (centrifugally tensioned metastable fluid detector). The disclosed CTMFD radiation detection system includes a detector assembly containing a detection fluid, a base, a safety enclosure, a motor and motor mounting bracket, speed sensors, a cooling system that includes an air inlet and outlet and a safety enclosure. The CTMFD radiation detection system can include a plurality of independent detector arms having fluids with distinct Pneg requirements such that the range of detectable radiation is increased. Also disclosed are methods for detecting radiation using the disclosed CTMFD radiation detection system. Motor speed calibration procedures are also disclosed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Results on radiation tolerance of diamond detectors

In sight of the luminosity increase of the High Luminosity-LHC (HL-LHC), most experiments at the CERN Large Hadron Collider (LHC) are planning upgrades for their innermost layers in the next 5–10 years. These upgrades will require more radiation tolerant technologies than exist today. Usage of Chemical Vapor Deposition (CVD) diamond as detector material is one of the potentially interesting technologies for the upgrade. CVD diamond has been used extensively in the beam condition monitors of BaBar, Belle, CDF and all LHC experiments. Measurements of the radiation tolerance of the highest quality polycrystalline CVD material for a range of proton energies, pions and neutrons obtained with this material are presented. In addition, new results on the evolution of various semiconductor parameters as a function of the dose rate are described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Radiation-Hard Silicon Drift Detector Array for Extraterrestrial Element Mapping

Measurement of x-rays from the surface of objects can tell us about the chemical composition Absorption of radiation causes characteristic fluorescence from material being irradiated. By measuring the spectrum of the radiation and identifying lines in the spectrum, the emitting element (s) can be identified. This technique works for any object that has no absorbing atmosphere and significant surface irradiation : Our Moon, the icy moons of Jupiter, the moons of Mars, the planet Mercury, Asteroids and Comets

Gaskin, Jessica↗

Search for modulations of the solar {sup 7}Be flux in the next-generation neutrino observatory LENA

A next-generation liquid-scintillator detector will be able to perform high-statistics measurements of the solar neutrino flux. In LENA, solar {sup 7}Be neutrinos are expected to cause 1.7x10{sup 4} electron recoil events per day in a fiducial volume of 35 kilotons. Based on this signal, a search for periodic modulations on a subpercent level can be conducted, surpassing the sensitivity of current detectors by at least a factor of 20. The range of accessible periods reaches from several minutes, corresponding to modulations induced by helioseismic g-modes, to tens of years, allowing to study long-term changes in solar fusion rates.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radiological Impact of Phosphogypsum Application in Agriculture

Phosphogypsum (PG) contains radionuclides from {sup 238}U and {sup 232}Th decay series. Due to the presence of these radionuclides, many countries restricted the use of PG in agriculture, however there is not such restriction in Brazil. The main objective of this work was to evaluate the impact of PG application on {sup 226}Ra ({sup 238}U) and {sup 228}Ra ({sup 232}Th) concentrations in soil. Gamma-spectrometry was carried out using HPGe detector. No increment of {sup 226}Ra and {sup 228}Ra was observed for increasing PG doses. Average values found for {sup 226}Ra and {sup 228}Ra were respectively 37 Bq kg{sup -1} and 57 Bq kg{sup -1}. The results showed that the increasing PG doses in the specific conditions of the experiment did not cause a significant increment of radionuclides.

60 APPLIED LIFE SCIENCES↗

Characterization of Low Gain Avalanche Detector Prototypes’ Response to Gamma Radiation

Motivated by the need for fast timing detectors to withstand up to 2 MGy of ionizing dose at the High Luminosity Large Hadron Collider, prototype low gain avalanche detectors (LGADs) have been fabricated in a single pad configuration, 2 × 2 arrays, and related p-i-n diodes, and exposed to Co-60 sources for study. Devices were fabricated with a range of dopant layer concentrations, and for the arrays, a variety of inter-pad distances and distances from the active area to the edge. Measurements of capacitance versus voltage and leakage current versus voltage have been made to compare pre- and post-irradiation characteristics in gain layer depletion voltage, full bulk depletion voltage, and breakdown voltage. Conclusions are drawn regarding the effects of the gammas on both surface and interface states and on their contribution to acceptor removal through non-ionizing energy loss from Compton electrons or photoelectrons. Comparison of the performances of members of the set of devices can be used to optimize gain layer parameters.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗