Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Particle accelerator sciences”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

An in-vacuum x-ray diffraction microscope for use in the 0.7-2.9 keV range

A dedicated in-vacuum coherent x-ray diffraction microscope was installed at the 2-ID-B beamline of the Advanced Photon Source for use with 0.7-2.9 keV x-rays. The instrument can accommodate three common implementations of diffractive imaging; plane wave illumination; defocused-probe (Fresnel diffractive imaging) and scanning (ptychography) using either a pinhole, focused or defocused probe. The microscope design includes active feedback to limit motion of the optics with respect to the sample. Upper bounds on the relative optics-to-sample displacement have been measured to be 5.8 nm(v) and 4.4 nm(h) rms/h using capacitance micrometry and 27 nm/h using x-ray point projection imaging. The stability of the measurement platform and in-vacuum operation allows for long exposure times, high signal-to-noise and large dynamic range two-dimensional intensity measurements to be acquired. Finally, we illustrate the microscope's stability with a recent experimental result.

43 PARTICLE ACCELERATORS↗

Lifetime measurements in an electrostatic ion beam trap using image charge monitoring

A technique for mass-selective lifetime measurements of keV ions in a linear electrostatic ion beam trap is presented. The technique is based on bunching the ions using a weak RF potential and non-destructive ion detection by a pick-up electrode. This method has no mass-limitation, possesses the advantage of inherent mass-selectivity, and offers a possibility of measuring simultaneously the lifetimes of different ion species with no need for prior mass-selection.

43 PARTICLE ACCELERATORS↗

Demonstration of a real-time interferometer as a bunch-length monitor in a high-current electron beam accelerator

A real-time interferometer (RTI) has been developed to monitor the bunch length of an electron beam in an accelerator. The RTI employs spatial autocorrelation, reflective optics, and a fast response pyro-detector array to obtain a real-time autocorrelation trace of the coherent radiation from an electron beam thus providing the possibility of online bunch-length diagnostics. A complete RTI system has been commissioned at the A0 photoinjector facility to measure sub-mm bunches at 13 MeV. Bunch length variation (FWHM) between 0.8 ps ({approx}0.24 mm) and 1.5 ps ({approx}0.45 mm) has been measured and compared with a Martin-Puplett interferometer and a streak camera. The comparisons show that RTI is a viable, complementary bunch length diagnostic for sub-mm electron bunches.

43 PARTICLE ACCELERATORS↗

Study of multilayer-reflected beam profiles and their coherence properties using beamlines ID19 (ESRF) and 32-ID (APS)

The use of multilayer mirrors is an interesting alternative for reflective X-ray monochromatization with respect to reflection from crystal optics. The increased photon flux density due to the multilayers' larger bandwidth is of crucial importance for, e.g, full-field X-ray imaging applications. Drawbacks are the introduced modifications of the reflected beam profile as well as a certain loss of coherence, summarized as wavefront degradation. Our recent work has shown that the modification of the beam profile can vary with, e.g., the material composition of the coating applied. In order to verify our findings, a beamline round-robin has been initiated, comparing the wavefront profiles after reflection by selected multilayers at beamlines 32-ID (Advanced Photon Source) and ID19 (European Synchrotron Radiation Facility) with our initial results acquired at BM05 (ESRF) [1].

43 PARTICLE ACCELERATORS↗

Source fabrication and lifetime for Li{sup +} ion beams extracted from alumino-silicate sources

A space-charge-limited beam with current densities (J) exceeding 1 mA/cm{sup 2} have been measured from lithium alumino-silicate ion sources at a temperature of {approx}1275 deg. C. At higher extraction voltages, the source appears to become emission limited with J{>=} 1.5 mA/cm{sup 2}, and J increases weakly with the applied voltage. A 6.35 mm diameter source with an alumino-silicate coating, {<=}0.25 mm thick, has a measured lifetime of {approx}40 h at {approx}1275 deg. C, when pulsed at 0.05 Hz and with pulse length of {approx}6 {mu}s each. At this rate, the source lifetime was independent of the actual beam charge extracted due to the loss of neutral atoms at high temperature. The source lifetime increases with the amount of alumino-silicate coated on the emitting surface, and may also be further extended if the temperature is reduced between pulses.

43 PARTICLE ACCELERATORS↗

Diamond detector for high rate monitors of fast neutrons beams

A fast neutron detection system suitable for high rate measurements is presented. The detector is based on a commercial high purity single crystal diamond (SDD) coupled to a fast digital data acquisition system. The detector was tested at the ISIS pulsed spallation neutron source. The SDD event signal was digitized at 1 GHz to reconstruct the deposited energy (pulse amplitude) and neutron arrival time; the event time of flight (ToF) was obtained relative to the recorded proton beam signal t{sub 0}. Fast acquisition is needed since the peak count rate is very high ({approx}800 kHz) due to the pulsed structure of the neutron beam. Measurements at ISIS indicate that three characteristics regions exist in the biparametric spectrum: i) background gamma events of low pulse amplitudes; ii) low pulse amplitude neutron events in the energy range E{sub dep}= 1.5-7 MeV ascribed to neutron elastic scattering on {sup 12}C; iii) large pulse amplitude neutron events with E{sub n} < 7 MeV ascribed to {sup 12}C(n,{alpha}){sup 9}Be and 12C(n,n')3{alpha}.

43 PARTICLE ACCELERATORS↗

Indus synchrotron source: A national facility

Indus Synchrotron Radiation complex at Raja Ramanna Centre for Advanced Technology at Indore, India houses two synchrotron radiation sources: Indus-1 and Indus-2 respectively. Indus-1 is a 450 MeV source emitting in VUV and soft x-ray region and operating at 100 mA since 1990 and Indus-2, designed for 2.5 GeV, 300 mA and is currently operating at 2 GeV and 100 mA. Indus-1 has five operational beamlines while Indus-2 has six beamlines installed and operational. Several materials research related problems have been investigated using the reflectivity and photo-electron spectroscopy beamlines at Indus-1 and also the beamlines at Indus-2. Here we will report the current status of both these sources and discuss a few of our studies carried out using these beamlines.

43 PARTICLE ACCELERATORS↗

Neutron beam imaging at neutron spectrometers at Dhruva

A low efficiency, 2-Dimensional Position Sensitive Neutron Detector based on delay line position encoding is developed. It is designed to handle beam flux of 10{sup 6}-10{sup 7} n/cm{sup 2}/s and for monitoring intensity profiles of neutron beams. The present detector can be mounted in transmission mode, as the hardware allows maximum neutron transmission in sensitive region. Position resolution of 1.2 mm in X and Y directions, is obtained. Online monitoring of beam images and intensity profile of various neutron scattering spectrometers at Dhruva are presented. It shows better dynamic range of intensity over commercial neutron camera and is also time effective over the traditionally used photographic method.

43 PARTICLE ACCELERATORS↗

Optimization of drift bias in an UHV based pulsed positron beam system

We report here the design of ultra high vacuum (UHV) compatible pulsed positron beam lifetime system, which combines the principles of a conventional slow positron beam and RF based pulsing scheme. The mechanical design and construction of the UHV system to house the beam has been completed and it has been tested for a vacuum of {approx} 10{sup -10} mbar. The voltages applied to the drift tube as a function of positron energies have been optimized using SIMION.

43 PARTICLE ACCELERATORS↗

Commissioning of a microprobe-XRF beamline (BL-16) on Indus-2 synchrotron source

We report commissioning of the microprobe-XRF beamline on Indus-2 synchrotron source. The beamline has been recently made operational and is now open for the user's experiments. The beamline comprises of Si(111) double crystal monochromator and Kirkpatrick-Baez focusing optics. The beamline covers wide photon energy range of 4 - 20 keV using both collimated and micro-focused beam modes. The design details and the first commissioning results obtained using this beamline are presented.

43 PARTICLE ACCELERATORS↗

Application of multilayer mirror for harmonic analysis in soft X-ray region

Order contamination in soft x-ray beamline is a severe problem which poses difficulty in various analysis techniques. Generally grating analyzer is used to estimate the higher order contribution where poor knowledge of wall and land roughness contribution makes it difficult to get theoretical fit and so analysis gives qualitative estimation only. Here we demonstrate the application of multilayer mirror for accurate determination of order contamination in Toroidal grating monochromator (TGM) at reflectivity beamline of Indus-1. We used a Mo/Si multilayer of d{approx}100Aa period to quantify 2{sup nd} and 3{sup rd} order composition to identify order contamination below 0.5% or better.

43 PARTICLE ACCELERATORS↗

Analysis of order contamination from toroidal grating monochromator of Indus-1 reflectivity beamline

The synchrotron radiation spectra of toroidal grating monochromators (TGM) often contaminated by significant amounts of higher orders. Quantitative estimation of order contamination is essential in order to perform quantitative spectroscopy measurements. At Indus-1 reflectivity beamline higher order contaminations from TGM monochromator are experimentally determined using a reflection grating analyzer. It is found that the order contamination in wavelength range of 50-200 A is less than 15%. Use of edge filters reduces the order contamination level below 5% in this wavelength range.

43 PARTICLE ACCELERATORS↗

Commissioning of soft and deep X-ray lithography beamline on Indus-2

Soft and Deep x-ray lithography (SDXRL) beamline is commissioned on Indus-2. The beamline can be operated between 1.5 to 20 keV and in white beam mode. Beamline consists of two x-ray mirrors, slits, Be-windows, beam diagnostics and filters assemblies and radiation safety systems. A custom built X-ray scanner is used to create 3-D high aspect ratio micro structures. The paper reports the commissioning results of this beamline.

43 PARTICLE ACCELERATORS↗

Measurement of absolute diffraction efficiency of a variable line spaced grating using reflectivity beamline

First and second order diffraction efficiency of a variable line spacing grating of average 1200 lines/mm density is measured at the reflectivity beam line of Indus-1. This grating is blazed at 3.2 deg. and has a blaze wavelength of 10 nm. The measurement has been carried out in the spectral range of 4.5 nm to 80 nm at 3o grazing angle of incidence. The maximum diffraction efficiency of the first order at {approx}10 nm has been found to be {approx} 23% and for the second order it is {approx}13%.

43 PARTICLE ACCELERATORS↗

Note: Emittance measurements of intense pulsed proton beam for different pulse length and repetition rate

The high intensity ion source (SILHI), in operation at CEA-Saclay, has been used to produce a 90 mA pulsed proton beam with pulse length and repetition rates suitable for the European Spallation Source (ESS) linac. Typical r-r{sup '} rms normalized emittance values smaller than 0.2{pi} mm mrad have been measured for operation in pulsed mode (0.01 < duty cycle < 0.15 and 1 ms < pulse duration < 10 ms) that are relevant for the design update of the Linac to be used at the ESS in Lund.

43 PARTICLE ACCELERATORS↗

Absolute energy calibration for relativistic electron beams with pointing instability from a laser-plasma accelerator

The pointing instability of energetic electron beams generated from a laser-driven accelerator can cause a serious error in measuring the electron spectrum with a magnetic spectrometer. In order to determine a correct electron spectrum, the pointing angle of an electron beam incident on the spectrometer should be exactly defined. Here, we present a method for absolutely calibrating the electron spectrum by monitoring the pointing angle using a scintillating screen installed in front of a permanent dipole magnet. The ambiguous electron energy due to the pointing instability is corrected by the numerical and analytical calculations based on the relativistic equation of electron motion. It is also possible to estimate the energy spread of the electron beam and determine the energy resolution of the spectrometer using the beam divergence angle that is simultaneously measured on the screen. The calibration method with direct measurement of the spatial profile of an incident electron beam has a simple experimental layout and presents the full range of spatial and spectral information of the electron beams with energies of multi-hundred MeV level, despite the limited energy resolution of the simple electron spectrometer.

43 PARTICLE ACCELERATORS↗

Electrical shielding box measurement of the negative hydrogen beam from Penning ion gauge ion source

The cold-cathode Penning ion gauge (PIG) type ion source has been used for generation of negative hydrogen (H{sup -}) ions as the internal ion source of a compact cyclotron. A novel method called electrical shielding box dc beam measurement is described in this paper, and the beam intensity was measured under dc extraction inside an electrical shielding box. The results of the trajectory simulation and dc H{sup -} beam extraction measurement were presented. The effect of gas flow rate, magnetic field strength, arc current, and extraction voltage were also discussed. In conclusion, the dc H{sup -} beam current of about 4 mA from the PIG ion source with the puller voltage of 40 kV and arc current of 1.31 A was extrapolated from the measurement at low extraction dc voltages.

43 PARTICLE ACCELERATORS↗