Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PV system performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

Acceptance Testing of a Satellite SCADA Photovoltaic-Diesel Hybrid System

Satellite Supervisory Control and Data Acquisition (SCADA) of a Photovoltaic (PV)/diesel hybrid system was tested using NASA's Advanced Communication Technology Satellite (ACTS) and Ultra Small Aperture Terminal (USAT) ground stations. The setup consisted of a custom-designed PV/diesel hybrid system, located at the Florida Solar Energy Center (FSEC), which was controlled and monitored at a "remote" hub via Ka-band satellite link connecting two 1/4 Watt USATs in a SCADA arrangement. The robustness of the communications link was tested for remote monitoring of the health and performance of a PV/diesel hybrid system, and for investigating load control and battery charging strategies to maximize battery capacity and lifetime, and minimize loss of critical load probability. Baseline hardware performance test results demonstrated that continuous two-second data transfers can be accomplished under clear sky conditions with an error rate of less than 1%. The delay introduced by the satellite (1/4 sec) was transparent to synchronization of satellite modem as well as to the PV/diesel-hybrid computer. End-to-end communications link recovery times were less than 36 seconds for loss of power and less than one second for loss of link. The system recovered by resuming operation without any manual intervention, which is important since the 4 dB margin is not sufficient to prevent loss of the satellite link during moderate to heavy rain. Hybrid operations during loss of communications link continued seamlessly but real-time monitoring was interrupted. For this sub-tropical region, the estimated amount of time that the signal fade will exceed the 4 dB margin is about 10%. These results suggest that data rates of 4800 bps and a link margin of 4 dB with a 1/4 Watt transmitter are sufficient for end-to-end operation in this SCADA application.

Kalu, A.↗

Achieving Very High Efficiency and Net Zero Energy in an Existing Home in a Hot-Humid Climate: Long-Term Utility and Monitoring Data

This study summarizes the first six months of detailed data collected on a single family home that experienced a series of retrofits targeting reductions in energy use. The project was designed to develop data on how envelope modifications and renewable measures can result in considerable energy reductions and potentially net zero energy for an existing home. Originally published in February 2012, this revised version of the report contains further research conducted on the Parker residence. Key updates include one full year of additional data, an analysis of cooling performance of the mini-split heat pump, an evaluation of room-to-room temperature distribution, and an evaluation of plug-in automobile charging performance, electricity consumption, and load shape.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cost Analysis of Heavy-Duty Vehicle Proton Exchange Membrane Fuel Cell Stationary Power Plants

Heavy-duty PEM fuel cells could be a low-cost, low emission alternative to combustion turbines for re-electrifying hydrogen if used as part of a long duration grid energy storage systems. Many studies expect heavy duty PEM fuel cell production costs to reduce as manufacturing volumes ramp up and their expected durability of 25,000-30,000 hours aligns well with a 30-year life for hydrogen seasonal energy storage plants that would likely operate less than 10% of the year. The labor, material, and equipment costs associated with installing PEM fuel cells and their required balance of plant for stationary applications have not been thoroughly explored, however. This study performs a detailed design and cost analysis of a 100 MW stationary PEM fuel cell power plant, capturing costs such as cooling, power electronics, pipes, valves, fittings, cabling, conduit, concrete foundations, buildings, and land. It employs methods consistent with NLR's solar PV benchmarking cost analysis and annual technology baseline to derive the total installed costs of stationary PEM fuel cell plants that utilize heavy duty PEM fuel cells.

08 HYDROGEN↗

CSP Plant Optimization Study for the California Power Market (“CalCSP”) (Final Technical Report)

Concentrating Solar Power (CSP) with thermal energy storage offers a unique and strategic opportunity to support California’s clean energy transition. Unlike photovoltaic (PV) systems, CSP with thermal storage can generate electricity after sunset and during periods of high demand, making it a valuable complement to intermittent renewable resources. CSP also provides synchronous, inertia-contributing generation, long-duration storage, and flexible dispatch—capabilities increasingly important as thermal plants retire. This report summarizes the findings of the CSP Plant Optimization Study for the California Power Market or “CalCSP study,” which evaluated the technical, economic, environmental, and policy factors that influence the deployment of CSP technologies in California. The CalCSP study was conducted to assess how CSP can contribute to California’s long-term decarbonization goals while enhancing grid reliability, supporting local economic development, and making efficient use of land and transmission resources. It draws on detailed modeling of CSP performance and costs, site suitability analysis, policy reviews, and stakeholder engagement across utilities, regulators, developers, and community organizations. The analysis focuses on mature molten-salt tower technology and incorporates lessons learned from the global CSP fleet, distinguishing today’s CSP from earlier first-of-a-kind projects in the U.S. The findings support a more prominent role for CSP in California’s evolving clean energy landscape. With strategic planning, targeted policy support, and continued cost improvements, CSP can complement PV and batteries to deliver reliable, around-the-clock clean electricity—especially in areas with high solar resource and constrained grid capacity.

14 SOLAR ENERGY↗

Ice storage model-predictive control in an office building with PV: scenario, error and sensitivity analysis

Thermal energy storage (TES) can enable more building-sited renewable electricity generation and lower utility bill costs for buildings owners and occupants, especially when there are high demand and variable time-of-use (TOU) charges. A model predictive control (MPC) strategy can offer additional savings over a schedule-based control with added complexity and reliance on forecasts. Here, this study examines savings for medium office buildings with chiller plants in three locations with building-installed solar photovoltaics (PV) to understand the impact of MPC. Control setpoints are fixed by a schedule-based control or optimized by nonlinear MPC. These control setpoints are actuated within EnergyPlus building models to simulate the utility cost of the chiller plant. NLP solutions can be unstable or unrealistic, but our results show that by regularizing the NLP, the solutions can be reasonably followed by the building model. MPC models make simplifications that lead to errors once the controller is participating in and changing the operation of the building. These errors average 9 % across the cases, showing that the most important parts of the system are represented. The no-thermal load costs are computed to show that the optimization can in some cases achieve both the minimum TOU and minimum monthly demand costs by demand management while reducing TOU energy costs by energy arbitrage. The MPC saves 35–66 % in the annual chiller plant operating costs, which is an additional savings above the schedule by 1–33 %. PV and TES are complementary and mostly independent, but a load with PV often results in better performance for the schedule. Our case study and sensitivity analysis show the importance of modeling and optimization for complex rates, but also the circumstances wherein a simpler strategy achieves the same performance with less potential for error.

14 SOLAR ENERGY↗

Comparison of four MPPT techniques for PV systems

The working behavior of a module / PV array is non-linear and highly dependent on working conditions. As a given condition, there is only one point at which the level of available power at its output is maximum. This point varies with time, enlightenment and temperature. To ensure optimum operation, the use of MPPT control allows us to extract the maximum power. This paper presents a comparative study of four widely-adopted MPPT algorithms, such as Perturb and Observe, Incremental Conductance, Measurements of the variation of the open circuit voltage or of the short-circuit current. Their performance is evaluated using, for all these techniques. In particular, this study compares the behaviors of each technique in presence of solar irradiation variations and temperature fluctuations. These MPPT techniques will be compared using the Matlab / Simulink tool.

14 SOLAR ENERGY↗

Achieving Very High Efficiency and Net Zero Energy in an Existing Home in a Hot-Humid Climate: Long-Term Utility and Monitoring Data (Revised)

This study summarizes the first six months of detailed data collected on a single family home that experienced a series of retrofits targeting reductions in energy use. The project was designed to develop data on how envelope modifications and renewable measures can result in considerable energy reductions and potentially net zero energy for an existing home. Originally published in February2012, this revised version of the report contains further research conducted on the Parker residence. Key updates include one full year of additional data, an analysis of cooling performance of the mini-split heat pump, an evaluation of room-to-room temperature distribution, and an evaluation of plug-in automobile charging performance, electricity consumption, and load shape.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance characteristics of a combination solar photovoltaic heat engine energy converter

A combination solar photovoltaic heat engine converter is proposed. Such a system is suitable for either terrestrial or space power applications. The combination system has a higher efficiency than either the photovoltaic array or the heat engine alone can attain. Advantages in concentrator and radiator area and receiver mass of the photovoltaic heat engine system over a heat-engine-only system are estimated. A mass and area comparison between the proposed space station organic Rankine power system and a combination PV-heat engine system is made. The critical problem for the proposed converter is the necessity for high temperature photovoltaic array operation. Estimates of the required photovoltaic temperature are presented.

Chubb, Donald L.↗

Performance characteristics of a combination solar photovoltaic heat engine energy converter

A combination solar photovoltaic heat engine converter is proposed. Such a system is suitable for either terrestrial or space power applications. The combination system has a higher efficiency than either the photovoltaic array or the heat engine alone can attain. Advantages in concentrator and radiator area and receiver mass of the photovoltaic heat engine system over a heat-engine-only system are estimated. A mass and area comparison between the proposed space station organic Rankine power system and a combination PV-heat engine system is made. The critical problem for the proposed converter is the necessity for high temperature photovoltaic array operation. Estimates of the required photovoltaic temperature are presented.

Chubb, Donald L.↗

Coordinated distribution network control of tap changer transformers, capacitors and PV inverters

A power distribution system operates most efficiently with voltage deviations along a feeder kept to a minimum and must ensure all voltages remain within specified limits. Recently with the increased integration of photovoltaics, the variable power output has led to increased voltage fluctuations and violation of operating limits. This study proposes an optimization model based on a recently developed heuristic search method, grey wolf optimization, to coordinate the various distribution controllers. Several different case studies on IEEE 33 and 69 bus test systems modified by including tap changing transformers, capacitors and photovoltaic solar panels are performed. Simulation results are compared to two other heuristic-based optimization methods: harmony search and differential evolution. Finally, the simulation results show the effectiveness of the method and indicate the usage of reactive power outputs of PVs facilitates better voltage magnitude profile.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Environmental Effects on ISS Materials Aging (1998 to 2008)

The performance of ISS spacecraft materials and systems on prolonged exposure to the low- Earth orbit (LEO) space flight are reported in this paper. In-flight data, flight crew observations, and the results of ground-based test and analysis directly supporting programmatic and operational decision-making are described. The space flight environments definitions (both natural and induced) used for ISS design, material selection, and verification testing are shown, in most cases, to be more severe than the actual flight environment accounting, in part, for the outstanding performance of ISS as a long mission duration spacecraft. No significant ISS material or system failures have been attributed to spacecraft-environments interactions. Nonetheless, ISS materials and systems performance data is contributing to our understanding of spacecraft material interactions with the spaceflight environment so as to reduce cost and risk for future spaceflight projects and programs. Orbital inclination (51.6 deg) and altitude (nominally near 360 km) determine the set of natural environment factors affecting the functional life of materials and systems on ISS. ISS operates in an electrically conducting environment (the F2 region of Earth s ionosphere) with well-defined fluxes of atomic oxygen, other charged and neutral ionospheric plasma species, solar UV, VUV, and x-ray radiation as well as galactic cosmic rays, trapped radiation, and solar cosmic rays. The LEO micrometeoroid and orbital debris environment is an especially important determinant of spacecraft design and operations. The magnitude of several environmental factors varies dramatically with latitude and longitude as ISS orbits the Earth. The high latitude orbital environment also exposes ISS to higher fluences of trapped energetic electrons, auroral electrons, solar cosmic rays, and galactic cosmic rays than would be the case in lower inclination orbits, largely as a result of the overall shape and magnitude of the geomagnetic field. As a result, ISS exposure to many environmental factors can vary dramatically along a particular orbital ground track, and from one ground track to the next, during any 24-hour period. The induced environment results from ISS interactions with the natural environment as well as environmental factors produced by ISS itself and visiting vehicles fleet. Examples include ram-wake effects, hypergolic thruster plume impingement, materials out-gassing, venting and dumping of fluids, and specific photovoltaic (PV) power system interactions with the ionospheric plasma (7-11). Vehicle size (L) and velocity (V), combined with the magnitude and direction of the geomagnetic field (B) produce operationally significant magnetic induction voltages (VxB.L) in ISS conducting structure during flight through high latitudes (> +45deg) during each orbit. Finally, an induced ionizing radiation environment is produced by cosmic ray interaction with the relatively thick ISS structure and shielding materials. The intent of this review article is, therefore, to provide a summary of selected aspects and elements of the ISS vehicle with regard to LEO space environment effects, associated with the much larger and more complicated vehicle that ISS has become since 1998, but also with an eye towards performance life extension to the year 2016 and beyond.

Alred, John↗

Micro-optics for high-efficiency optical performance and simplified tracking for concentrated photovoltaics (CPV).

Micro-optical 5mm lenses in 50mm sub-arrays illuminate arrays of photovoltaic cells with 49X concentration. Fine tracking over {+-}10{sup o} FOV in sub-array allows coarse tracking by meter-sized solar panels. Plastic prototype demonstrated for 400nm < {lambda} < 1600 nm. We have designed a solar collector that will be composed of 50-mm-diameter sub-arrays, each containing {approx}100 5-mm plastic micro-lenses. Each micro-lens illuminates a stack of about four 0.7mm PV cells that collect sunlight from 400nm to 1600 nm with a theoretical efficiency approaching 50%. Each sub-array has internal solar tracking and alignment over a {+-}10{sup o} field, so a large array of sub-arrays only needs to coarsely track the sun. The refractive lenses in the design are thin so the optical transmission can be >90% and the optics will weigh very little. There are other optical properties incorporated in this design that help the photovoltaic cells to operate very efficiently. We are building a pre-prototype system now, and will describe our progress at the conference.

14 SOLAR ENERGY↗

Degradation Mechanism Detection in Photovoltaic Backsheets by Fully Convolutional Neural Network

Materials and devices age with time. Material aging and degradation has important implications for lifetime performance of materials and systems. While consensus exists that materials should be studied and designed for degradation, materials inspection during operation is typically performed manually by technicians. The manual inspection makes studies prone to errors and uncertainties due to human subjectivity. In this work, we focus on automating the process of degradation mechanism detection through the use of a fully convolutional deep neural network architecture (F-CNN). We demonstrate that F-CNN architecture allows for automated inspection of cracks in polymer backsheets from photovoltaic (PV) modules. The developed F-CNN architecture enabled an end-to-end semantic inspection of the PV module backsheets by applying a contracting path of convolutional blocks (encoders) followed by an expansive path of decoding blocks (decoders). First, the hierarchy of contextual features is learned from the input images by encoders. Next, these features are reconstructed to the pixel-level prediction of the input by decoders. The structure of the encoder and the decoder networks are thoroughly investigated for the multi-class pixel-level degradation type prediction for PV module backsheets. The developed F-CNN framework is validated by reporting degradation type prediction accuracy for the pixel level prediction at the level of 92.8%.

14 SOLAR ENERGY↗

Recommendations for Data-in-Transit Requirements for Securing DER Communications

With the adoption of Distributed Energy Resource (DER) interoperability standards, common communication protocols are now being deployed between power system operators and DER devices. In 2018, a revision to the US interconnection and interoperability standard, Institute of Electrical and Electronics Engineers (IEEE) Std. 1547, required DER equipment to have an IEEE 2030.5, IEEE 1815, or SunSpec Modbus communication exchange interface. This change supports the future transition to secure connection and exchange of information between the DER equipment and implementing parties, such as grid operators. Adoption of standardized communication protocols and associated information models is a critical step toward interoperability between power system operators and DER, such as photovoltaic (PV) and energy storage systems. However, security requirements for these standardized communication protocols are not comprehensive, resulting in non-standard and vendor-specific implementation that may leave DER equipment susceptible to cyberattacks. This paper examines the data-in-flight security requirements for standardized DER communication protocols, per IEEE 1547-2018 revision, as it relates to device authentication, key management, and encryption. The state of the art for these security features is also explored, addressing their impact on communication and performance of low-cost single board computers, which are typical of DER devices. In conclusion, a recommendation is provided to adopt a common set of communication requirements, which are intended to achieve interoperability and implement data security over DER network pathways, while ensuring reliable, secure, and real-time information delivery.

42 ENGINEERING↗

Optimized V1G and V2G Electric Vehicle Fleet Management and Grid Transaction at Marine Corps Air Station Miramar in San Diego, CA

The overall technical goal of the project was to demonstrate an all-electric bi-directional non-tactical fleet at Marine Corps Air Station (MCAS) Miramar that was integrated and controlled with other distributed energy resources (DERs) (i.e., PV, stationary battery, and building loads) to provide resilience to critical electric loads in the event of grid outages, to minimize charging costs, and to provide economic energy resources to electricity markets. In this project, the specific, technical objectives were: 1. Demonstrate that bi-directional electric vehicles can provide critical complementary services to fixed storage batteries in microgrid applications while performing function as non-tactical vehicles. 2. Demonstrate participation of bi-directional (V2G) and unidirectional (V1G) PEVs for demand management and minimization of charging costs. 3. Demonstrate integration of multiple DERs for grid service participation. US Marine Corps Air Station (MCAS) Miramar in San Diego was the site of this electric vehicle-to-microgrid-utility grid test and demonstration project. Existing microgrid assets in this study included (1) a public works building; (2) a 30-kW rooftop photovoltaic (PV) system and (3) a separate 250 kW carport PV system. In this project, six bi-directional V2G vans were located at the MCAS Miramar’s showcase building-scale microgrid to develop and test technical capabilities that V2G can provide in microgrid applications (e.g., cost reduction and resiliency). These resources provided aggregated demand management and simulated participation in current retail DR programs. The vehicles used in this demonstration were selected because they provided functionality that MCAS Miramar needed, 15 passenger transport and facilities work cargo carrying capacity, and bi-directional charging capability that the research project required. All vehicles in this study were manufactured and distributed by VIA Motors, Inc. There were six vehicles total and each was VIA’s VTRUX eREV V2G model, a modified General Motors Chevrolet 2500 2WD van. Three of the vans were configured as passenger vans and the other three were configured as cargo vans. Each van had an on-board bi-direcrtional inverter/charger, Bel Power Solutions model 350INVCHGT150-120-240-8G nominally rated at +/-15 kW. The VIA van’s charging connector follows the J1772 charging protocol. The bi-directional EVSEs demonstrated in this study were manufactured by Coritech, Inc. Each VGI-80-AC charging station enabled enhanced V2G charging capability to a Clipper Creek CS-100 charging module. The enhanced capabilities included ethernet communication following the SEP2.0 protocol with a distributed energy resource function set and an operator screen displaying real-time SOC, voltage, and current. The VGI-80-AC charging stations are classified as level 2 with a maximum current output of 80 A or effectively 19 kW. The VIA van’s onboard charger limited the charging and discharging power to 15 kW in each direction. A control computer was installed in the EWOC and connected to an existing monitor. The V2G control communication network was a completely stand-alone closed system that did not have any connection to any other networks on the base. A cybersecure remote communication connection was created with a cellular modem, firewall hardware, and a virtual private network configuration.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Fast Grid Frequency Support from Distributed Inverter-Based Resources

This presentation summarizes power hardware-in-the-loop testing performed to evaluate the ability of distributed inverter-coupled generation to support grid frequency on the fastest time scales. The research found that distributed PV inverters and other DERs can effectively support the grid on sub-second time scales.

14 SOLAR ENERGY↗

Solar Radiometry and Metrology, Session: Modeling and Analysis (Presentation)

This project supports the Solar America Initiative by: (1) Providing solar radiometric measurements, data, and related technical information support to NREL Measurements and Characterization Task; NREL Reliability and Durability Task; Systems and component testing and evaluation for the SAI TPPs; Requests from industry; (2) Producing credible radiometric measurements traceable to recognized standards for performance and Industry applications in accordance with IS0-17025 accreditation scope; (3) Contributing to consensus codes and standards for performance and measurement techniques for NREL R&D, SAI TPPs, and industry applications; (4) Maintain stability of the NREL solar radiation reference (absolute cavity radiometers); (5) Execute high quality detailed radiometric calibrations for broadband and spectral radiometers to meet NREL research and PV industry needs; (6) Participate in national and international consensus standards development, contributing technical expertise, data, and analysis where appropriate; (7) Provide technical information on solar radiation resource data and applications to meet research and industry needs; and (8) Transfer technology in this area to other researchers and industry via publications and conference papers and presentations.

14 SOLAR ENERGY↗