Disposal of hypergolic propellants. phase 6, task 3: Prototype disposal pond
The design and operation of a prototype diposal of hypergolic propellants waste are described. Experiments with water hyacinths were performed.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
The design and operation of a prototype diposal of hypergolic propellants waste are described. Experiments with water hyacinths were performed.
A process was developed for autoclave molding structural poly-(Diels-Alder) polyimide (PDA) resin/HTS graphite composites for short-term 600 F service. The autoclave molding process used to fabricate these composites required a maximum cure temperature of 427 K (400 F) and a maximum molding pressure of 0.7 MN/sq m (100 psig). This process then was adapted to the fabrication of co-cured polyimide sandwich panels consisting of PDA/HTS skins, PDA syntactic foam and polyimide/glass honeycomb core. Fabrication ease was demonstrated by manufacturing five three-quarter scale YF-12 wing panels using the PDA resin. It was concluded from successful evaluation of these prototype units that the PDA resin is suitable for fabrication of components using commercial equipment.
The design and development of a prototype carbon dioxide absorber using potassium carbonate (K2CO3) is described. Absorbers are constructed of thin, porous sheets of supported K2CO3 that are spirally wound to form a cylindrical reactor. Axial gas passages are formed between the porous sheets by corrugated screen material. Carbon dioxide and water in an enclosed life support system atmosphere react with potassium carbonate to form potassium bicarbonate. The potassium carbonate is regenerated by heating the potassium bicarbonate to 150 C at ambient pressure. The extravehicular mission design conditions are for one man for 8 h. Results are shown for a subunit test module investigating the effects of heat release, length-to-diameter ratio, and active cooling upon performance. The most important effect upon carbon dioxide removal is the temperature of the potassium carbonate.
Manual for prototype solar-heating system gives detailed installation procedures for each of seven subsystems. Procedures for operation and maintenance are also included. It discusses architectural considerations, building construction considerations, and checkout-test procedures.
Four reports trace development from preliminary design through delivery of hardware. Developmental test, including airflow, air temperature, and efficiency are discussed in reports, as are qualification tests on prototypes and final acceptance tests. Qualification test program includes measurements tests, and structural analysis.
A prototype solar heating and hot water system using air as the collector fluid and a pebble bed for heat storage was designed for installation into a single family dwelling. The system, subsystem, and installation requirements are described. System operation and performance are discussed, and procedures for sizing the system to a specific site are presented.
This report consists of details for the installation, operation and maintenance of a prototype heating and hot water system, designed for residential or light commercial applications. This system consists of the following subsystems: air type collectors, pebble bed thermal storage, air handling unit, air to water heat exchanger, hot water preheat tank, auxiliary energy, ducting system.
Progress made in the development, delivery, and support of two prototype solar heating and cooling systems including potable hot water is reported. The system consists of the following subsystems: collector, auxiliary heating, potable hot water, storage, control, transport, and government-furnished site data acquisition. A comparison of the proposed Solaron Heat Pump and Solar Desiccant Heating and Cooling Systems, installation drawings, data on the Akron House at Akron, Ohio, and other program activities are included.
The testing, problems encountered, and the results and conclusions obtained from tests performed on the IBM Prototype System, 2, solar hot water system, at the Marshall Space Flight Center Solar Test Facility was described. System 2 is a liquid, non draining solar energy system for supplying domestic hot water to single residences. The system consists of collectors, storage tank, heat exchanger, pumps and associated plumbing and controls.
Information is provided on the design and performance of the IBM SIMS Prototype System 2, solar domestic hot water system, for single family residences. The document provides sufficient data to permit procurement, installation, operation, and maintenance by qualified architectural engineers or contractors.
Prototype solar heating and cooling systems are described. Development, manufacture, test, system installation, maintenance, problem resolution, and performance evaluation are discussed.
The plan schedule and status of multiple objectives to be achieved in the development, manufacture, installation, and maintenance of two solar heated hot water prototype systems and two heat exchangers are reported. A computer program developed to resolve problems and evaluate system performance is described.
Information necessary to evaluate the design and assembly of a solar hot water system is presented. A prototype system designed for use in a single family dwelling is investigated in terms of the following subsystems: collector, storage, energy transport, and control.
The prototype system 2 solar hot water was designed for use in a single family dwelling and consists of the following subsystems: collector, storage, energy transport, and control. Guidelines are presented for utilization in the development of detailed installation plans and specifications. Instruction on operation, maintenance, and repair of the system is discussed.
A prototype electric power management and thruster control system for a 30 cm ion thruster is described. The system meets all of the requirements necessary to operate a thruster in a fully automatic mode. Power input to the system can vary over a full two to one dynamic range (200 to 400 V) for the solar array or other power source. The power management and control system is designed to protect the thruster, the flight system and itself from arcs and is fully compatible with standard spacecraft electronics. The system is easily integrated into flight systems which can operate over a thermal environment ranging from 0.3 to 5 AU. The complete power management and control system measures 45.7 cm (18 in.) x 15.2 cm (6 in.) x 114.8 cm (45.2 in.) and weighs 36.2 kg (79.7 lb). At full power the overall efficiency of the system is estimated to be 87.4 percent. Three systems are currently being built and a full schedule of environmental and electrical testing is planned.
A preliminary design review on the development of a prototype solar heating system for single family dwellings is presented. The collector, storage, transport, control, and site data acquisition subsystems are described.
Eight prototype solar heating and combined heating and cooling systems are considered. This effort includes development, manufacture, test, installation, maintenance, problem resolution, and performance evaluation.
Eight prototype solar heating and combined heating and cooling systems are being developed. The effort includes development, manufacture, test, installation, maintenance, problem resolution, and performance evaluation.