High-Reliability Power Control and Distribution Electronics for the Europa Clipper Mission
No abstract provided
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
No abstract provided
This presentation covers an overview of electrical insulation development activities taking place under NASA's Advanced Air Transport Technology and Transformational Tools and Technologies Project.
Explore the source record for details and available documents.
Work on the NYSERDA-MDAO project, presented at the OpenMDAO workshop.
The dataset consists of results and various input data that are used in the GAMS model for the publication "Repeal of the Clean Power Plan: Social Cost and Distributional Implications". All the data are either excel files or in the .inc format which can be read within GAMS or Notepad. Main data sources include: agriculture, transportation and electricity data. Model details can be found in the paper and the GAMS model package.
The Jupiter Icy Moons Orbiter (JIMO) mission will send a spacecraft to explore three of Jupiter s moons (Callisto, Ganymede, and Europa), all of which show evidence of containing vast subterranean oceans beneath their icy surfaces. The evidence of these oceans was discovered by Galileo, and the moons are believed to have the three essential ingredients for life: water, energy, and the necessary chemical elements. Galileo has shown that melted water on Europa has been in contact with the surface of the moon in geologically recent times, and may still lie relatively close to the surface. This project will also introduce a revolutionary new form of electric propulsion powered by a nuclear fission reactor. This electric propulsion is called ion propulsion. It was used on a previous mission called Deep Space 1, proving that ion propulsion works for interplanetary travel. Since JIMO will be traveling farther from the sun, solar power will be difficult to supply the electric energy demanded by the mission. Therefore a nuclear reactor and a thermo-electric converter system will be necessary. Besides making the trip to three of Jupiter's moons - one after the other - a realistic possibility, this new form of power and propulsion opens up the rest of the outer solar system for future exploration. JIMO will fulfill its goals by exploring Europa first, with subsequent trips to the moons Callisto and Ganymede in order to provide comparisons key to understanding the evolution of all three. In order to ensure the stability and proper preparation of the electrical system on JIMO, the High Power AC Power Management and Distribution (PMAD) Test Bed is being developed. The testing on.this AC PMAD will consist of electrical performance verification of candidate power system components. Examples of these components are: high power AC switchgear, high power ACDC converters, AC power distribution units, DC power distribution units, etc. Throughout the course of the summer the over-current control circuit for the five different size relays will be constructed and tested. This circuit will sense the current input to the spacecraft loads and automatically switch off power if the current is too high. Once the circuit is verified to function properly and all necessary modifications have been made, a circuit schematic and board layout will have to be drawn using OrCAD, and the circuits will have to be built.
Solving optimal power flow (OPF) problem for large distribution networks incurs high computational complexity. We consider a large multi-phase distribution networks of tree topology with deep penetration of active devices. We divide the network into collaborating areas featuring subtree topology and subareas featuring subsubtree topology. We design a multi-level implementation of the primal-dual gradient algorithm for solving the voltage regulation OPF problems while preserving nodal voltage information and topological information within areas and subareas. Numerical results on a 4,521-node system verifies that the proposed algorithm can significantly improve computational speed without compromising any optimality.
In this work, a distributed frequency divider is proposed to estimate power system bus frequency with a limited number of PMUs while considering the inertial contributions from double-fed induction generators (DFIGs). The key idea is to reformulate the original frequency divider by modeling the contributions of DFIGs with inertia emulation and external regional power system through Thevenin equivalents. The distributed frequency divider is general and able to estimate local bus frequencies in a distributed manner. Besides, only the knowledge of the rotor speeds of synchronous generator, boundary bus frequencies and terminal bus frequencies of DFIGs as well as the admittance matrix are required to estimate the frequencies at all buses. This is drastically different from existing approaches that require system observability by PMUs to monitor all bus frequencies. Numerical results carried out on the IEEE 39-bus and modified 118-bus power systems with DFIGs demonstrate and effectiveness and robustness of the proposed method.
Not Available
In this paper, we propose an AC optimal power flow (ACOPF) model considering distributed flexible AC transmission system (D-FACTS) devices, in which the reactance of D-FACTS equipped lines are introduced as decision variables. This is motivated by increasing interests in using D-FACTS devices to address system operational and cyber-security concerns. First, D-FACTS devices can be incorporated in real-time operations for economic benefits such as managing power congestions and reducing system losses. Second, D-FACTS devices can be utilized by moving target defense (MTD), an emerging concept against cyber-attacks, to prevent attackers from knowing true system configurations. Therefore, system operators can use the proposed ACOPF model to achieve economic benefits and provide the setpoints of D-FACTS devices for MTD at the same time. In addition, we rigorously derive the gradient and Hessian matrices of the objective function and constraints, which are further used to build an interior-point solver of the proposed ACOPF. Numerical results on the IEEE 118-bus transmission system show the validity of the proposed ACOPF model as well as the efficacy of the interior-point solver in minimizing system losses and generation costs.
Integrated transmission-and-distribution (T&D) modeling is a new and developing method for simulating power systems. Interest in integrated T&D modeling is driven by the changes taking place in power systems worldwide that are resulting in more decentralized power systems with increasingly high levels of distributed energy resources. Additionally, the increasing role of the hitherto passive energy consumer in the management and operation of power systems requires more capable and detailed integrated T&D modeling to understand the interactions between T&D systems. Although integrated T&D modeling has not yet found widespread commercial application, its potential for changing the decades-old power system modeling approaches has led to several research efforts in the last few years that tried to (i) develop algorithms and software for steady-state and dynamic modeling of power systems and (ii) demonstrate the advantages of this modeling approach compared with traditional, separated T&D system modeling. In this paper, we provide a review of integrated T&D modeling research efforts and the methods employed for steady-state and dynamic modeling of power systems. We also discuss our current research in integrated T&D modeling and the potential directions for future research. This paper should be useful for power systems researchers and industry members because it will provide them with a critical summary of current research efforts and the potential topics where research efforts are needed to further advance and demonstrate the utility of integrated T&D modeling.
As NASA works to extend human exploration of the solar system, unprecedented capacity for electrical and thermal energy will be needed to support sustained human presence and the beginning of industrial activity on the Moon. Solar energy is abundant on the lunar surface but extended night hours (up to 350 consecutive hours) and extreme temperature change from daylight to nighttime operation creates complexity for solar power use. Analogous issues arise on Earth, where demand for additional renewable energy generation, including solar, is rising, but better power management, distribution, and energy storage solutions are needed to address intermittency and resiliency, among other issues. To accelerate the development of technologies for power distribution and energy storage that can operate in extreme lunar conditions, NASA’s Centennial Challenges Program launched the Watts on the Moon Challenge in September 2020. Submissions for Phase 1 of the challenge were due in March 2021 and winners were announced in May 2021. This paper provides an overview of the challenge, key technical requirements, outcomes from Phase 1, and an update on Phase 2 of the challenge, which is currently ongoing.
This grant funded a Market and Technology Assessment project which included 1) an analysis of the total addressable market (TAM) for the RT-OPF technology; 2) a segmented assessment of North American utility business models and barriers to adoption of the RT-OPF technology for those models; 3) a validation of DER customer needs and barriers to participation in utility programs; and 4) a forward-looking analysis of utility regulatory innovation and changes that may impact utility business models and ability for utilities to adopt this technology.
The 9500 Node Test System is a representative section of distribution power system model developed as a part of the GridAPPS-D™ project, an effort funded by DOE as a part of the Grid Modernization Lab Consortium (GMLC) program. The test system was developed to fulfill a growing need to represent the rapidly evolving state of electric distribution systems by combining elements of legacy infrastructure systems, modern feeder topologies, and an anticipated future with smart grid technologies. It also provides a network model capable of supporting the simulation of operational scenarios such as the ones in a utility distribution control center. This test system allows the evaluation of the performance of advanced power applications in real-time, such as one that simulates the operations of an Advanced Distribution Management Systems (ADMS), Distributed Energy Resource Management Systems (DERMS), etc. in a Distribution control center. This model is an extension of the widely used IEEE 8500 Node Test Feeder and is currently being validated to become an IEEE test case to help increase adoption and widespread usage among both academia and industry. It is a full-size model representative of a section of a utility’s distribution system with multiple feeders fed from different substations. The model includes multiple distribution circuits, a sub-transmission system, multiple substations, behind the meter customer rooftop photovoltaics (PV), and multiple utility-scale distributed energy resources. To enable accurate simulations of operational scenarios, the 9500 Node Test System is designed to support procedure-based operations, with the ability to realistically demonstrate switching operations, feeder reconfiguration, adjustment of volt-var control equipment, dispatch of distributed generation, and response to planned and unplanned outages. The 9500 Node Test System includes three radial distribution feeders with 12.3 MVA of average load, consisting of both medium voltage and low voltage equipment each supplied by a different distribution substation. The three distribution feeders are connected to each other through Normally-Open switches which can be closed when needed to simulate restoration scenarios due to a fault. One feeder represents today’s grid with low penetration of customer-side renewables. The second represents a potential future grid with microgrids and 100% renewable penetration. The third has no customer generation resources, a district steam plant, and a utility-scale solar farm. The three diverse circuits were created to allow the simulation of both today’s situation as well as potential future scenarios. All three feeders have customers connected by low-voltage secondary triplex lines. This test system meets all requirements outlined in the report for creating a simulation environment that would enable discussion between key technical stakeholders as well as having the potential to accelerate operational application development and their subsequent testing and integration. The new model is a possible representation of what we believe the distribution grid may look like in the future: a high penetration of renewables, reconfigurable radial and mesh topology, numerous DERs, islanded microgrids, and significantly increased data and measurement density. The system supports both the solution of existing and newer algorithms but also enables the evaluation of applications in a realistic operational environment defined by task oriented procedural steps that represent the interaction between the control center operator and field personnel.
Unbalanced faults in distribution feeders can impact voltages on the non-faulted phases. This paper models a real-life feeder with a high penetration level of solar photovoltaic (PV) units in detail including the secondary circuits, and shows a large voltage swell in one of the non-faulted phases of the feeder during a single line to ground fault. The voltages seen during this swell are more than 1.2 p.u., which can have detrimental impacts on the connected equipment and can also lead to loss of connected generation. The reason for this voltage swell is found to be the equivalent impedance at the fault location resulting from the ratio of zero and positive sequence cable impedances. It is seen that the connected solar PV units with appropriate control are able to reduce the severity of the voltage swell, especially for higher penetration levels of solar PV considered, but not entirely eliminate it.
Future spacecraft power systems must be capable of supplying power to various loads. This delivery of power may necessitate the use of high-voltage, high-power dc distribution systems to transmit power from the source to the loads. Using state-of-the-art power conditioning electronics such as dc-dc converters, complex series and parallel configurations may be required at the interface between the source and the distribution system and between the loads and the distribution system. This research will use state-variables to model and simulate a dc spacecraft power system. Each component of the dc power system will be treated as a multiport network, and a state model will be written with the port voltages as the inputs. The state model of a component will be solved independently from the other components using its state transition matrix. A state-space averaging method is developed first in general for any dc-dc switching converter, and then demonstrated in detail for the particular case of the boost power stage. General equations for both steady-state (dc) and dynamic effects (ac) are obtained, from which important transfer functions are derived and applied to a special case of the boost power stage.
A method for determining power output levels of a plurality of nodes in an electric power system includes receiving, at a first node of the plurality of nodes, voltage information and multipliers of all neighboring nodes of the first node within the electric power system, determining, by the first node, a local power generation and a local voltage using the voltage information and the multipliers of the neighboring nodes and distributing the local power generation and the local voltage to the neighboring nodes, determining, by the first node, an estimated voltage of each of the neighboring nodes and distributing the estimated voltage to each of the neighboring nodes, and updating, by the first node, a local multiplier using the voltage information received from the neighboring nodes and the estimated voltage of each of the neighboring nodes determined by the node.
Distributed Energy Resources (DER) such as photovoltaic (PV) systems and battery energy storage systems (BESS) can be operated collectively as microgrids. Microgrids can be effective in meeting local load requirements as well as in improving the power quality and stability in a modern power distribution system. Multiple microgrids can also be operated in a coordinated manner as a cluster, to improve the resiliency of the power distribution system. In the event of an outage caused by a transmission system failure, the microgrids in a cluster can use their distributed generation capacity and energy storage resources to recover and extend power availability to the critical loads in the system. In this paper, an illustrative cluster of two microgrids based on the IEEE 13-bus model with DERs has been used, to demonstrate the operation of the concept using real-time simulations. Using real-time simulations, capabilities such as switching reconfiguration following faults, identification of optimal DER placement for effective power quality management, and power electronic controller validation have been demonstrated. For the two-microgrid cluster, this paper also presents improvements in load voltage quality and