Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Oscillation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

Early Oscillation Detection for Hybrid DC/DC Converter Fault Diagnosis

This paper describes a novel fault detection technique for hybrid DC/DC converter oscillation diagnosis. The technique is based on principles of feedback control loop oscillation and RF signal modulations, and Is realized by using signal spectral analysis. Real-circuit simulation and analytical study reveal critical factors of the oscillation and indicate significant correlations between the spectral analysis method and the gain/phase margin method. A stability diagnosis index (SDI) is developed as a quantitative measure to accurately assign a degree of stability to the DC/DC converter. This technique Is capable of detecting oscillation at an early stage without interfering with DC/DC converter's normal operation and without limitations of probing to the converter.

Wang, Bright L.↗

Gravitational Changes of the Earth's Free Oscillation From Earthquakes: Theory and Feasibility Study Using GRACE Inter‐Satellite Tracking

GRACE satellites have detected regional‐scale preseismic, coseismic, and postseismic gravity changes associated with great earthquakes during the GRACE era (2002‐2017). Earthquakes also excite global‐scale transient gravity changes associated with free oscillations that may be discerned for a few days. In this study, we examine such global gravity changes due to Earth's free oscillations and quantify how they affect GRACE measurements. We employ the normal mode formalism to synthesize the global gravity changes after the 2004 Sumatra earthquake and simulate the (gravitational) free oscillation signals manifested in the GRACE K‐band ranging (KBR) measurements. Using the Kaula orbit perturbation theory, we show how GRACE inter‐satellite distances are perturbed through a complex coupling of eigenfrequencies of the normal modes with the Earth's rotation rate and the GRACE satellites' orbital frequency. It is found that a few gravest normal modes can generate range‐rate perturbations as large as 0.2 μm/s, which are comparable to actual errors of GRACE KBR ranging and accelerometer instruments. Wavelet time‐frequency analysis of the GRACE KBR residual data in December 2004 reveals the existence of a significant transient signal after the 2004 Sumatra earthquake. This transient signal is characterized by a frequency of ~0.022 mHz that could be potentially associated with the largest excitation due to the “football” mode of the Earth's free oscillation. However, the results are also affected by low‐frequency noise of the GRACE accelerometers. Improved space‐borne gravitational instrumentation may open new opportunities to study the Earth's interior and earthquakes independently from global seismological analysis.

Ghobadi-Far, Khosro↗

Analysis of the long-term drift rates and oscillations of Jupiter’s largest vortices

Jupiter’s troposphere is dynamically characterized by a series of alternating eastward and westward jets. Embedded between these alternating jets, large vortices, characterized by their high speed closed circulations can be found in several latitudinal bands. The Great Red Spot (GRS) and the White Ovals (WOS) located at ≈22 and ≈30 degrees south respectively1 are the largest of these vortices. The GRS has undergone significant changes in size, coloration and maximum circumferential wind speed over the last two decades. The three WOS also experienced changes in size, and they merged over time until there was only one remaining, which since then has been formally known as oval BA. Here we used over four decades worth of data from the Database for Object Positions on Jupiter (JUPOS), to investigate the long-term mean longitudinal drift of these largest vortices, and to characterize the deviations from this mean drift. A linear fit to the GRS drift speed for the last two decades gives a rate of change of (3.1 ± 0.4)^(-3°)/day/year. For oval BA we find that its annual drift rate changed from -0.39°/day in 2016 to -0.58°/day in 2020 following a steep trend that is best fitted by a second order polynomial. Regarding oscillations, we find that for the last two decades the GRS has continued to oscillate longitudinally with the same period (90 days) and peak-to-peak amplitude (1.2 degrees longitude) as reported historically. For the WOS, the data prior to 2000 seems to indicate that they presented similar oscillations with periods of ≈158 days and peak-to-peak amplitudes of ≈1.6 degrees. The analysis of the data for oval BA since the year 2000 reveals evidence of an oscillation with a period of ≈138 days and peak-to-peak amplitude of ≈1.6 degrees longitude.

Raúl Morales-Juberías↗

Seasonal Tidewater Glacier Terminus Oscillations Bias Multi-Decadal Projections of Ice Mass Change

Numerical, process-based simulations of tidewater glacier evolution are necessary to project future sea-level change under various climate scenarios. Previous work has shown that nonlinearities in tidewater glacier and ice stream dynamics can lead to biases in simulated ice mass change in the presence of noisy forcings. Ice sheet modeling projections that are used in the IPCC Assessment Report 6 (AR6) utilize atmospheric and oceanic forcings at annual temporal resolution, omitting any higher frequency forcings. Here, we quantify the effect of seasonal (<1 year) tidewater glacier terminus oscillations on decadal-scale (30 years) mass change. We use an idealized geometry to mimic realistic tidewater glacier geometries and investigate the impact of the magnitude of seasonal oscillations, bed slope at the glacier terminus, and basal friction law. We find that omitting seasonal terminus motion results in biased mass change projections, with up to an 39% underestimate or 25% overestimate of mass loss when seasonality is neglected, depending on bed slope and magnitude of oscillations. The bias is most sensitive to the magnitude of the seasonal terminus oscillations and exhibits very little sensitivity to choice of friction law. Although omitting seasonal terminus motion may bias mass change projections of individual glaciers, further work is needed to investigate the impact on ice sheet mass change projections. In order to achieve this, seasonality in atmospheric and oceanic forcings must be adequately represented and observations of seasonal terminus positions and tidewater glacier thickness changes must be acquired to evaluate numerical models. Note: Zip folder contains all videos listed in the supplemental document and can be downloaded for viewing.

D. Felikson↗

Detection of p-mode Oscillations in HD 35833 with NEID and TESS

We report the results of observations of p-mode oscillations in the G0 subgiant star HD 35833 in both radial velocities and photometry with NEID and TESS, respectively. We achieve separate, robust detections of the oscillation signal with both instruments (radial velocity amplitude ARV = 1.11 ± 0.09 m s−1, photometric amplitude Aphot = 6.42 ± 0.60 ppm, frequency of maximum power nmax = 595.71  17.28 μHz, and mode spacing Δν = 36.65 ± 0.96 μHz) as well as a nondetection in a TESS sector concurrent with the NEID observations. These data shed light on our ability to mitigate the correlated noise impact of oscillations with radial velocities alone and on the robustness of commonly used asteroseismic scaling relations. The NEID data are used to validate models for the attenuation of oscillation signals for exposure times t max < n-1 , and we compare our results to predictions from theoretical scaling relations and find that the observed amplitudes are weaker than expected by >4σ, hinting at gaps in the underlying physical models.

Arvind F Gupta↗

Real-time combustion control and diagnostics sensor-pressure oscillation monitor

An apparatus and method for monitoring and controlling the combustion process in a combustion system to determine the amplitude and/or frequencies of dynamic pressure oscillations during combustion. An electrode in communication with the combustion system senses hydrocarbon ions and/or electrons produced by the combustion process and calibration apparatus calibrates the relationship between the standard deviation of the current in the electrode and the amplitudes of the dynamic pressure oscillations by applying a substantially constant voltage between the electrode and ground resulting in a current in the electrode and by varying one or more of (1) the flow rate of the fuel, (2) the flow rate of the oxidant, (3) the equivalence ratio, (4) the acoustic tuning of the combustion system, and (5) the fuel distribution in the combustion chamber such that the amplitudes of the dynamic pressure oscillations in the combustion chamber are calculated as a function of the standard deviation of the electrode current. Thereafter, the supply of fuel and/or oxidant is varied to modify the dynamic pressure oscillations.

47 OTHER INSTRUMENTATION↗

High frequency nanotube oscillator

A tunable nanostructure such as a nanotube is used to make an electromechanical oscillator. The mechanically oscillating nanotube can be provided with inertial clamps in the form of metal beads. The metal beads serve to clamp the nanotube so that the fundamental resonance frequency is in the microwave range, i.e., greater than at least 1 GHz, and up to 4 GHz and beyond. An electric current can be run through the nanotube to cause the metal beads to move along the nanotube and changing the length of the intervening nanotube segments. The oscillator can operate at ambient temperature and in air without significant loss of resonance quality. The nanotube is can be fabricated in a semiconductor style process and the device can be provided with source, drain, and gate electrodes, which may be connected to appropriate circuitry for driving and measuring the oscillation. Novel driving and measuring circuits are also disclosed.

47 OTHER INSTRUMENTATION↗

Nonlinear nanomechanical oscillators for ultrasensitive inertial detection

A system for ultrasensitive mass and/or force detection of this invention includes a mechanical oscillator driven to oscillate in a nonlinear regime. The mechanical oscillator includes a piezoelectric base with at least one cantilever resonator etched into the piezoelectric base. The cantilever resonator is preferably a nonlinear resonator which is driven to oscillate with a frequency and an amplitude. The system of this invention detects an amplitude collapse of the cantilever resonator at a bifurcation frequency as the cantilever resonator stimulated over a frequency range. As mass and/or force is introduced to the cantilever resonator, the bifurcation frequency shifts along a frequency axis in proportion to the added mass.

47 OTHER INSTRUMENTATION↗

Oscillating fluid power generator

A system and method for harvesting the kinetic energy of a fluid flow for power generation with a vertically oriented, aerodynamic wing structure comprising one or more airfoil elements pivotably attached to a mast. When activated by the moving fluid stream, the wing structure oscillates back and forth, generating lift first in one direction then in the opposite direction. This oscillating movement is converted to unidirectional rotational movement in order to provide motive power to an electricity generator. Unlike other oscillating devices, this device is designed to harvest the maximum aerodynamic lift forces available for a given oscillation cycle. Because the system is not subjected to the same intense forces and stresses as turbine systems, it can be constructed less expensively, reducing the cost of electricity generation. The system can be grouped in more compact clusters, be less evident in the landscape, and present reduced risk to avian species.

30 DIRECT ENERGY CONVERSION↗

A Combined $\nu_\mu \rightarrow \nu_e$ and $\bar \nu_\mu \rightarrow \bar \nu_e$ Oscillation Analysis of the MiniBooNE Excesses

The MiniBooNE experiment at Fermilab reports results from an analysis of the combined $\nu_e$ and $\bar \nu_e$ appearance data from $6.46 \times 10^{20}$ protons on target in neutrino mode and $11.27 \times 10^{20}$ protons on target in antineutrino mode. A total excess of $240.3 \pm 34.5 \pm 52.6$ events ($3.8 \sigma$) is observed from combining the two data sets in the energy range $200<E_\nu^{QE}<1250$ MeV. In a combined fit for CP-conserving $\nu_\mu \rightarrow \nu_e$ and $\bar{\nu}_{\mu}\rightarrow\bar{\nu}_e$ oscillations via a two-neutrino model, the background-only fit has a $\chi^2$-probability of 0.03% relative to the best oscillation fit. The data are consistent with neutrino oscillations in the $0.01 < \Delta m^2 < 1.0$ eV$^2$ range and with the evidence for antineutrino oscillations from the Liquid Scintillator Neutrino Detector (LSND).

43 PARTICLE ACCELERATORS↗

Constraints on neutrino oscillation parameters with the NOvA experiment

NOvA is a long-baseline neutrino oscillation experiment, which consists of two finely-segmented liquid-scintillator detectorsoperating 14 mrad off-axis from the NuMI muon neutrino beam. With an 810 km baseline, the combined measurements of muon neutrino disappearance and electron neutrino appearance allow the determination of neutrino oscillation unknowns, namely the mass hierarchy, the octant of the largest neutrino mixing angle, and the CP violating phase.In this dissertation, I present the joint analysis of $\nu_\mu\to\nu_\mu$ and $\nu_mu\to\nu_e$ oscillation data with an exposure of$8.85\times10^{20}$ protons on target on the 14 kton detector. It includes the estimation of neutrino energy distributions in the fardetector using near detector data constraints, details of the implementation of the simultaneous fit of \numu and \nue samples, andthe effect of systematic uncertainties on the measurement of oscillation parameters. I also discuss NOvA's projected sensitivity to determine the mass hierarchy and discover CP violation in future analyses with increased exposure and the addition ofantineutrino datasets.With 66 electron neutrino and 126 muon neutrino candidates, the bestfit to the data corresponds to the normal mass hierarchy, $\Delta m^2_{32}=2.44\times 10^{-3} eV^2/c^4$, $\sin^2\theta_{23}=0.56$,and $\delta_{CP} = 1.21\pi$, with the allowed regions $\Delta m^2_{32} \in[2.37,2.52]\times 10^{-3} eV^2/c^4$, $\sin^2\theta_{23} \in [0.43,0.51] \cup[0.52,0.60]$ and $\delta_{CP} \in [0,0.12\pi] \cup [0.91\pi,2\pi]$ at the68.3\% C.L. Our data disfavor maximal mixing by 0.8$\sigma$, $\delta_{CP}= \pi/2$ in the inverted hierarchy at higher than 3$\sigma$, and theentire inverted mass hierarchy at the 95\% confidence level.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Evaluation of Mode Meters Robust to Forced Oscillations using Field-Measured Data

Mode meters are tools used by power system operators to continuously monitor a system's small-signal stability. They do so by estimating the system's electromechanical modes of oscillation. When a system undergoes a forced oscillation, mode meters may become biased because the two types of oscillation cannot be distinguished. Modified mode meter algorithms robust to this bias have been proposed in prior research, but these studies were based primarily on simulated data. In this paper, modified least squares and Yule-Walker mode meter algorithms are evaluated using field-measured data from phasor measurement units (PMUs). Results show that the sensitivities of the least squares algorithm make it impractical for use given the complexities of real-world forced oscillations. However, the modified Yule-Walker algorithm is shown to perform well and has significant potential for practical deployment in mode meter tools.

Follum, James D.↗

Gated ring oscillator with constant dynamic power consumption

A pure digital ring oscillator with constant power consumption as oscillation frequency is adjusted. Circuit topology includes a multiplexer implemented in NAND gates and a delay element positioned after a path selection NAND gate of that multiplexer such that delay element transistors may not toggle if the non-delaying signal path is selected. Assuming a delay element oscillation frequency f and a total capacitance C, and also assuming a plurality N of delay gates each characterized by a propagation delay t1 and a capacitance C1 such that C=C1*N, the ring oscillator of the present invention is characterized by a C value that is proportional to N and an f value that is inversely proportional to N. Furthermore, each of the N delay gates as well as the input and output gates of the multiplexer are characterized by a common capacitance-to-propagation delay ratio=C1/t1.

Wu, Jinyuan↗

Calibration technique of wall shear stress sensors using oscillating plate

Disclosed are a system and methods for calibrating wall shear stress sensors. The system includes an oscillating plate coupled to an actuator and mounted on a rolling elements, and one or more sensors coupled to a height adjusting device. The system can further comprise a height control rod coupled to a height control base and a sensor holder configured to house the one or more sensors and supported on a connector, the connector configured to be rotatably disposed about the height control rod. The system can be calibrated by causing the actuator to oscillate the oscillating plate at a frequency, sensing, using the one or more sensors, shear stress at a wall, the shear stress at the wall being associated with a velocity field, and determining a theoretical wall shear stress based on fluid properties, the frequency, and the height of the one or more sensors above the oscillating plate.

Freidkes, Brett R.↗

Gated ring oscillator with constant dynamic power consumption

A pure digital ring oscillator with constant power consumption as oscillation frequency is adjusted. Circuit topology includes a multiplexer implemented in NAND gates and a delay element positioned after a path selection NAND gate of that multiplexer such that delay element transistors may not toggle if the non-delaying signal path is selected. Assuming a delay element oscillation frequency f and a total capacitance C, and also assuming a plurality N of delay gates each characterized by a propagation delay t1 and a capacitance C1 such that C=C1*N, the ring oscillator of the present invention is characterized by a C value that is proportional to N and an f value that is inversely proportional to N. Furthermore, each of the N delay gates as well as the input and output gates of the multiplexer are characterized by a common capacitance-to-propagation delay ratio=C1/t1.

Wu, Jinyuan↗

Neutrino oscillations: Quantum mechanics vs. quantum field theory

A consistent description of neutrino oscillations requires either the quantum-mechanical (QM) wave packet approach or a quantum field theoretic (QFT) treatment. We compare these two approaches to neutrino oscillations and discuss the correspondence between them. In particular, we derive expressions for the QM neutrino wave packets from QFT and relate the free parameters of the QM framework, in particular the effective momentum uncertainty of the neutrino state, to the more fundamental parameters of the QFT approach. We include in our discussion the possibilities that some of the neutrino's interaction partners are not detected, that the neutrino is produced in the decay of an unstable parent particle, and that the overlap of the wave packets of the particles involved in the neutrino production (or detection) process is not maximal. Finally, we demonstrate how the properly normalized oscillation probabilities can be obtained in the QFT framework without an ad hoc normalization procedure employed in the QM approach.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The time-dependent quantum harmonic oscillator revisited: Applications to quantum field theory

In this article, we formulate the study of the unitary time evolution of systems consisting of an infinite number of uncoupled time-dependent harmonic oscillators in mathematically rigorous terms. We base this analysis on the theory of a single one-dimensional time-dependent oscillator, for which we first summarize some basic results concerning the unitary implementability of the dynamics. This is done by employing techniques different from those used so far to derive the Feynman propagator. In particular, we calculate the transition amplitudes for the usual harmonic oscillator eigenstates and define suitable semiclassical states for some physically relevant models. We then explore the possible extension of this study to infinite dimensional dynamical systems. Specifically, we construct Schroedinger functional representations in terms of appropriate probability spaces, analyze the unitarity of the time evolution, and probe the existence of semiclassical states for a wide range of physical systems, particularly, the well-known Minkowskian free scalar fields and Gowdy cosmological models.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Information theories for time-dependent harmonic oscillator

Highlights: > Information theories for the general time-dependent harmonic oscillator based on invariant operator method. > Time dependence of entropies and entropic uncertainty relation. > Characteristics of Shannon information and Fisher information. > Application of information theories to particular systems that have time-dependent behavior. - Abstract: Information theories for the general time-dependent harmonic oscillator are described on the basis of invariant operator method. We obtained entropic uncertainty relation of the system and discussed whether it is always larger than or equal to the physically allowed minimum value. Shannon information and Fisher information are derived by means of density operator that satisfies Liouville-von Neumann equation and their characteristics are investigated. Shannon information is independent of time, but Fisher information is explicitly dependent on time as the time functions of the Hamiltonian vary. We can regard that the Fisher information is a local measure since its time behavior is largely affected by local arrangements of the density, whilst the Shannon information plays the role of a global measure of the spreading of density. To promote the understanding, our theory is applied to special systems, the so-called quantum oscillator with time-dependent frequency and strongly pulsating mass system.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗