Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Optical Imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

Metasurface‐Based Mueller Matrix Microscope

In conventional optical microscopes, image contrast of objects mainly results from the differences in light intensity and/or color. Muller matrix optical microscopes (MMMs), on the other hand, can provide significantly enhanced image contrast and rich information about objects by analyzing their interactions with polarized light. However, state-of-the-art MMMs are fundamentally limited by bulky and slow polarization state generators and analyzers. Here, the study demonstrates a metasurface-based MMM, i.e., Meta-MMM, which is equipped with a chip-integrated, single-shot metasurface polarization state analyzer (Meta-PSA). The Meta-MMM is featured with high-speed measurement (≈2s per Muller matrix (MM) image), superior operation stability, dual-color operation, and high measurement accuracy (measurement error 1–2%) for MM imaging. The Meta-MMM is applied to nanostructure characterization, surface morphology analysis, and discovering birefringent structures in honeybee wings. As a result, the Meta-MMMs hold the promise to revolutionize various applications from biological imaging, medical diagnosis, and material characterization to industry inspection and space exploration.

36 MATERIALS SCIENCE↗

Diurnal Lightning Distributions as Observed by the Optical Transient Detector (OTD) and the Lightning Imaging Sensor (LIS)

Data obtained from the Optical Transient Detector (April 1995 to March 2000) and the Lightning Imaging Sensor (December 1997 to December 2005) satellites (70 and 35 inclination low earth orbits, respectively) are used to statistically determine the number of flashes in the annual and seasonal diurnal cycle as a function of local and universal time. The data are further subdivided by season, land versus ocean, northern versus southern hemisphere, and other spatial (e.g., continents) and temporal (e.g., time of peak diurnal amplitude) categories. The data include corrections for detection efficiency and instrument view time. Continental results display strong diurnal variation, with a lightning peak in the late afternoon and a minimum in late morning. In regions of the world dominated by large mesoscale convective systems the peak in the diurnal curve shifts toward late evening or early morning hours. The maximum diurnal flash rate occurs in June-August, corresponding to the Northern Hemisphere summer, while the minimum occurs in December-February. Summer lightning dominates over winter activity and springtime lightning dominates over autumn activity at most continental locations. This latter behavior occurs especially strongly over the Amazon region in South America in September-November. Oceanic lightning activity in winter and autumn tends to exceed that in summer and spring. Global lightning is well correlated in phase but not in amplitude with the Carnegie curve. The diurnal flash rate varies about 4-35 percent about the mean, while the Carnegie curve varies around 4-15 percent.

Bailey, Jeff C.↗

The role of chalcogen vacancies for atomic defect emission in MoS 2

For two-dimensional (2D) layered semiconductors, control over atomic defects and understanding of their electronic and optical functionality represent major challenges towards developing a mature semiconductor technology using such materials. Here, we correlate generation, optical spectroscopy, atomic resolution imaging, and ab initio theory of chalcogen vacancies in monolayer MoS 2 . Chalcogen vacancies are selectively generated by in-vacuo annealing, but also focused ion beam exposure. The defect generation rate, atomic imaging and the optical signatures support this claim. We discriminate the narrow linewidth photoluminescence signatures of vacancies, resulting predominantly from localized defect orbitals, from broad luminescence features in the same spectral range, resulting from adsorbates. Vacancies can be patterned with a precision below 10 nm by ion beams, show single photon emission, and open the possibility for advanced defect engineering of 2D semiconductors at the ultimate scale.

36 MATERIALS SCIENCE↗

Advances in imaging of chemically reacting flows

Many important chemically reacting systems are inherently multi-dimensional with spatial and temporal variations in the thermochemical state, which can be strongly coupled to interactions with transport processes. Fundamental insights into these systems require multi-dimensional measurements of the thermochemical state as well as fluid dynamics quantities. Laser-based imaging diagnostics provide spatially and temporally resolved measurements that help address this need. The state of the art in imaging diagnostics is continually progressing with the goal of attaining simultaneous multi-parameter measurements that capture transient processes, particularly those that lead to stochastic events, such as localized extinction in turbulent combustion. Development efforts in imaging diagnostics benefit from advances in laser and detector technology. This article provides a perspective on the progression of increasing dimensionality of laser-based imaging diagnostics and highlights the evolution from single-point measurements to 1D and 2D multi-parameter imaging and 3D high-speed imaging. This evolution is demonstrated using highlights of laser-based imaging techniques in combustion science research as an exemplar of a complex multi-dimensional chemically reacting system with chemistry–transport coupling. Imaging diagnostics impact basic research in other chemically reacting systems as well, such as measurements of near-surface gases in heterogeneous catalysis. The expanding dimensionality of imaging diagnostics leads to larger and more complex datasets that require increasingly demanding approaches to data analysis and provide opportunities for increased collaboration between experimental and computational researchers in tackling these challenges.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Semiconductor Laser With Two-Dimensional Beam Steering

Modification of monolithic semiconductor injection laser capable of one-dimensional electronic beam steering enables deflection of beam in second direction. Such laser chip provides beam pointing or raster scanning for applications in optical communications, data processing, image scanning, and optical ranging.

Katz, J.↗

The circumstellar environment of the emission-line star LkH-alpha 101

The environs of the premain-sequence, emission-line star, LkH-alpha 101, have been observed by broad-band CCD imaging, high-resolution optical spectroscopy, IRAS imaging, and single-dish, as well as interferometric, millimeter-line mapping. LkH-alpha 101 exhibits a high mass-loss rate (0.000011) low-velocity (350 km/s) ionized wind typical of early-type premain-sequence stars (Barsony, 1989). The millimeter interferometer maps show that this wind has cleared out a cavity in the molecular cloud surrounding LkH-alpha 101, allowing the rapid expansion of the previously observed VLA H II region (Becker and White, 1988).

Barsony, M.↗

Targeting an asteroid - The Galileo spacecraft's encounter with 951 Gaspra

On 1991 October 29, the Galileo spacecraft provided the first in situ observations of an asteroid. To a significant degree, the successful encounter with asteroid 951 Gaspra was made possible by the high accuracy of the ground-based Gaspra ephemeris and the refinement to this initial ephemeris provided by the use of optical navigation images taken on board the spacecraft itself. The success of these celestial navigation efforts was dramatically demonstrated when Gaspra appeared in the central frame of the large mosaic of CCD images-less than one asteroid diameter from Gaspra's expected location in the camera's field of view. The corrections to Gaspra's ground-based ephemeris, based upon the optical on-board navigation images, were less than 80 km. The ground-based observation program that went into this ephemeris development is discussed and the accuracy of the ephemeris is used to validate the assumptions that went into the error analysis studies.

Yeomans, D. K.↗

Ultra-Light Precision Membrane Optics

SRS Technologies and NASA Marshall Space Flight Center have conducted a research effort to explore the possibility of developing ultra-lightweight membrane optics for future imaging applications. High precision optical flats and spherical mirrors were produced under this research effort. The thin film mirrors were manufactured using surface replication casting of CPI(Trademark), a polyimide material developed specifically for UV hardness and thermal stability. In the course of this program, numerous polyimide films were cast with surface finishes better than 1.5 nanometers rms and thickness variation of less than 63 nanometers. Precision membrane optical flats were manufactured demonstrating better than 1/13 wave figure error when measured at 633 nanometers. The aerial density of these films is 0.037 kilograms per square meter. Several 0.5-meter spherical mirrors were also manufactured. These mirrors had excellent surface finish (1.5 nanometers rms) and figure error on the order of tens of microns. This places their figure error within the demonstrated correctability of advanced wavefront correction technologies such as real time holography.

Moore, Jim↗

Medics: Medical Decision Support System for Long-Duration Space Exploration

The Autonomous Medical Operations (AMO) group at NASA Ames is developing a “medical decision support system” to enable astronauts on long-duration exploration missions to operate autonomously. The system will support clinical actions by providing medical interpretation advice and procedural recommendations during emergent care and clinical work performed by crew. The current state of development of the system, called MedICS (Medical Interpretation Classification and Segmentation) includes two separate aspects: a set of machine learning diagnostic models trained to analyze organ images and patient health records, and an interface to ultrasound diagnostic hardware and to medical repositories. Three sets of images of different organs and medical records were utilized for training machine learning models for various analyses, as follows: 1. Pneumothorax condition (collapsed lung). The trained model provides a positive or negative diagnosis of the condition. 2. Carotid artery occlusion. The trained model produces a diagnosis of 5 different occlusion levels (including “normal”). 3. Ocular retinal images. The model extracts optic disc pixels (image segmentation). This is a precursor step for advanced autonomous fundus clinical evaluation algorithms to be implemented in FY20. 4. Medical health records. The model produces a differential diagnosis for any particular individual, based on symptoms and other health and demographic information. A probability is calculated for each of 25 most common conditions. The same model provides the likelihood of survival. All results are provided with a confidence level. Item 1 images were provided by the US Army and were part of a data set for the clinical treatment of injured battlefield soldiers. This condition is relevant to possible space mishaps, due to pressure management issues. Item 2 images were provided by Houston Methodist Hospital, and item 3 health records were acquired from the MIT laboratory of computational physiology. The machine learning technology utilized is deep multilayer networks (Deep Learning), and new models will continue to be produced, as relevant data is made available and specific health needs of astronaut crews are identified. The interfacing aspects of the system include a GUI for running the different models, and retrieving and storing data, as well as support for integration with an augmented reality (AR) system deployed at JSC by Tietronix Software Inc. (HoloLens). The AR system provides guidance for the placement of an ultrasound transducer that captures images to be sent to the MedICS system for diagnosis. The image captured and the associated diagnosis appear in the technician’s AR visual display.

Colombano, Silvano↗

Ritchey-Chretien Telescope

A Ritchey-Chretien telescope is described which was designed to respond to images located off the optical axis by using two transparent flat plates positioned in the ray path of the image. The flat plates have a tilt angle relative to the ray path to compensate for astigmatism introduced by the telescope. The tilt angle of the plates is directly proportional to the off axis angle of the image. The plates have opposite inclination angles relative to the ray paths. A detector which is responsive to the optical image as transmitted through the plates is positioned approximately on the sagittal focus of the telescope.

Rosin, S.↗

X-ray optics - A technique for high resolution imaging

Both scattering and figure errors in grazing incidence optics are larger in the plane of incidence than out-of-plane by a factor equal to 1/sin theta, where theta is the graze angle. When the full annular aperture of a grazing incidence telescope is stopped down, the point spread function becomes highly elliptical with a width as much as sin theta times narrower than the full image. In practice, this means that improvements in resolution of up to 100 times can be achieved, and effective resolution can approach the diffraction limit. Laboratory data demonstrating the effect are presented.

Cash, Webster↗

Siena Galaxy Atlas 2020

Abstract We present the 2020 version of the Siena Galaxy Atlas (SGA-2020), a multiwavelength optical and infrared imaging atlas of 383,620 nearby galaxies. The SGA-2020 uses optical grz imaging over ≈20,000 deg 2 from the Dark Energy Spectroscopic Instrument (DESI) Legacy Imaging Surveys Data Release 9 and infrared imaging in four bands (spanning 3.4–22 μ m) from the 6 year unWISE coadds; it is more than 95% complete for galaxies larger than R (26) ≈ 25″ and r < 18 measured at the 26 mag arcsec −2 isophote in the r band. The atlas delivers precise coordinates, multiwavelength mosaics, azimuthally averaged optical surface-brightness profiles, model images and photometry, and additional ancillary metadata for the full sample. Coupled with existing and forthcoming optical spectroscopy from the DESI, the SGA-2020 will facilitate new detailed studies of the star formation and mass assembly histories of nearby galaxies; enable precise measurements of the local velocity field via the Tully–Fisher and fundamental plane relations; serve as a reference sample of lasting legacy value for time-domain and multimessenger astronomical events; and more.

79 ASTRONOMY AND ASTROPHYSICS↗

X-ray mirror assessment with optical light

The imaging capability of a thin foil X-ray mirror has been examined with optical light, using a laser beam and a wide optical parallel beam. These measurements reveal that: (1) image broadening due to millimeter scale waviness (orange peel) of the aluminum substrate, partly intrinsic to the foil and partly caused during the foil treatment, is 1.2-min of arc half-power diameter (HPD) in two reflections; (2) slope errors due to foil shaping and misalignment cause broadening of 1.6-2.0-min of arc HPD; and (3) total broadening is about 3-min of arc HPD, which is consistent with the broadening of 2.6-min of arc HPD measured with X rays.

Kunieda, Hideyo↗

Background-free dual-mode optical and 13 C magnetic resonance imaging in diamond particles

Multimodal imaging—the ability to acquire images of an object through more than one imaging mode simultaneously—has opened additional perspectives in areas ranging from astronomy to medicine. In this paper, we report progress toward combining optical and magnetic resonance (MR) imaging in such a “dual” imaging mode. They are attractive in combination because they offer complementary advantages of resolution and speed, especially in the context of imaging in scattering environments. Our approach relies on a specific material platform, microdiamond particles hosting nitrogen vacancy (NV) defect centers that fluoresce brightly under optical excitation and simultaneously “hyperpolarize” lattice C 13 nuclei, making them bright under MR imaging. We highlight advantages of dual-mode optical and MR imaging in allowing background-free particle imaging and describe regimes in which either mode can enhance the other. Leveraging the fact that the two imaging modes proceed in Fourier-reciprocal domains (real and k-space), we propose a sampling protocol that accelerates image reconstruction in sparse-imaging scenarios. Our work suggests interesting possibilities for the simultaneous optical and low-field MR imaging of targeted diamond nanoparticles.

36 MATERIALS SCIENCE↗

Validation of Real-Time Data Processing for the Ground and Air-MSPI Systems

JPL is currently developing the multi-angle spectro-polarimetric imager (MSPI), targeted for the Aerosol-Cloud-Ecosystems (ACE) mission, as defined in the National Academies 2007 Decadal Survey. In preparation for the space instrument, the MSPI team has built two incremental camera systems (Ground- and Air-MSPI) to improve understanding of the proposed architecture. Ground-MSPI is a gimballed instrument used primarily for stationary observation and characterization of the imager and optics. The ER-2 based Air-MSPI operates in a step-and-stare mode, providing multi-angle imaging of a static target. This mode-of-operation simulates the observation scenario of the space instrument. Physically, MSPI is a pushbroom camera with a specialized frontend. Before imaging, light entering the camera passes through a pair of photoelastic modulators and a set of pattern polarizers. These optical elements act on the light to make polarimetric extraction computationally feasible. Calculating polarimetric parameters from the imager's data stream requires a real-time least-squares computation that produces coefficients of a truncated time-series expansion of the image. As reported in, the data processing algorithm can operate in real-time on a Xilinx Virtex-5 FPGA. Moving beyond verification with an onboard data source, the algorithm has been validated on a commercial development board interfaced with the ground camera. In addition, the algorithm has been instantiated within the Air-MSPI electronics board's FPGA, and in situ first-light has been achieved.

real-time data processing↗