Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Neutron Detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

Measuring planetary neutron albedo fluxes by remote gamma-ray sensing

In order to measure the planetary neutron albedo fluxes, a neutron-absorbing shield which emits gamma rays of characteristic energy and serves as a neutron detector, is added to a gamma-ray spectrometer (GRS). The gamma rays representing the neutron flux are observed against interference consisting of cosmic gamma rays, planetary continuum and line emission, and gamma rays arising from the interaction of cosmic rays with the GRS and the spacecraft. The uncertainty and minimum detection limits in neutron albedo fluxes are calculated for two missions, a lunar orbiter and a comet nucleus rendezvous. A GRS on a lunar orbiter at 100 km altitude detects a thermal neutron albedo flux as low as 0.002/sq cm/s and an expected flux of about 0.6/sq cm/s is measured with an uncertainty of 0.001/sq cm/s, for a 100 h observation period. For the comet nucleus, again in a 100 h observing period, a thermal neutron albedo flux is detected at a level of 0.006/sq cm/s and an expected flux of about 0.4/sq cm/s is measured with an uncertainty of 0.004/sq cm/s. The expanded geological capabilities made possible by this technique include improvements in H sensitivity, spatial resolution, and measurement depth; and an improved model of induced gamma-ray emission.

Haines, E. L.↗

Active neutron and gamma-ray imaging of highly enriched uranium for treaty verification

The detection and characterization of highly enriched uranium (HEU) presents a large challenge in the non-proliferation field. HEU has a low neutron emission rate and most gamma rays are low energy and easily shielded. To address this challenge, an instrument known as the dual-particle imager (DPI) was used with a portable deuterium-tritium (DT) neutron generator to detect neutrons and gamma rays from induced fission in HEU. We evaluated system response using a 13.7-kg HEU sphere in several configurations with no moderation, high-density polyethylene (HDPE) moderation, and tungsten moderation. A hollow tungsten sphere was interrogated to evaluate the response to a possible hoax item. First, localization capabilities were demonstrated by reconstructing neutron and gamma-ray images. Once localized, additional properties such as fast neutron energy spectra and time-dependent neutron count rates were attributed to the items. For the interrogated configurations containing HEU, the reconstructed neutron spectra resembled Watt spectra, which gave confidence that the interrogated items were undergoing induced fission. The time-dependent neutron count rate was also compared for each configuration and shown to be dependent on the neutron multiplication of the item. This result showed that the DPI is a viable tool for localizing and confirming fissile mass and multiplication.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Synthesis and processing of lithium-loaded plastic scintillators on the kilogram scale

Plastic scintillators that can discriminate between gamma rays, fast neutrons, and thermal neutrons were synthesized and characterized while considering the performance at the kilogram scale. The synthesis and processing of these plastic scintillators on the kilogram scale required examination of several factors. The examination of these factors was necessitated by the inclusion of 0.1 wt.% lithium-6 to enable detection of thermal neutrons. First, methacrylic acid was used as an additive to solubilize salts of lithium-6, which allow for a thermal-neutron capture reaction that produces scintillation light following energy transfer. Second, a trade-off between scintillation performance and processability was considered because the increasing content of the methacrylic acid that aided processability resulted in a sharp decrease in the light output. The use of small amounts of methacrylic acid (≤3 wt.%) resulted in better performance but required high processing temperatures. At large scales, these high temperatures could initiate exothermic polymerization that results in premature curing and/or defects. Additionally, the deleterious effects of the methacrylic acid may be mitigated by using m-terphenyl as a primary dye rather than 2,5-diphenyloxazole (PPO), which has been traditionally used in organic scintillators. Finally, the curing environment was controlled to avoid defects like cracking and discolouration​ while maintaining solubility of dopants during curing. For scintillators that were produced from kilogram-scale batches of precursors, the effective attenuation of scintillation light was characterized.

36 MATERIALS SCIENCE↗

Magnetized neutron stars as gamma-ray bursters - Detection rates at high energies

Detailed calculations of the escape of high-energy gamma-rays from the dipolar magnetosphere of general relativistic neutron star models are used to model the detection rate of bursters at high photon energies between 0.3 and 10 MeV. This analysis shows the SMM detection rates to be compatible with a magnetized neutron star origin, with a distribution of magnetic field strengths extending at least up to about 4 x 10 to the 12th G, as expected if the (20-60) keV features reported from Konus and Ginga measurements are interpreted as cyclotron lines. Additional implications are discussed for the emission geometry and the neutron star radius.

Meszaros, P.↗

Optimization of an Energy Tuning Assembly for High Explosives Detection

The Portable Isotopic Neutron Spectroscopy (PINS) system, employs neutron-induced gamma-ray spectroscopy and provides a nondestructive method for high explosives detection. In standard operation it uses Californium-252 as a neutron source. Operating PINS with a deuterium-tritium (DT) neutron generator has some advantages over Cf-252, including lifetime and ability to produce high-energy inelastic scattering gamma rays. However, current systems using DT neutron generators suffer from a high environmental background and reduced ability to induce neutron capture, reducing spectral quality and limiting nitrogen sensitivity. Here, this study presents the development of an energy-tuning assembly (ETA) designed to optimize the DT neutron energy spectrum to increase nitrogen reaction rates in a target, thereby improving high explosive detection capabilities. A metaheuristic optimization framework, MultiGNOWEE, coupled with MCNP, was employed to generate two ETA configurations: a single-objective ETA, which maximizes nitrogen capture reactions, and a multi-objective ETA, which balances neutron capture and inelastic scattering. Simulations demonstrated the optimized configurations achieved up to a 10-fold improvement in nitrogen capture rates compared to the bare configuration. Experimental validation was conducted using a DT neutron generator and a high-purity germanium (HPGe) detector. Two prototype ETAs were constructed and assessed on a melamine simulant. Measurements demonstrated improved nitrogen detection for both prototype ETA configurations when compared to the standard system.

97 MATHEMATICS AND COMPUTING↗

Neutron response characterization for an EJ299-33 plastic scintillation detector

Organic scintillation detectors have shown promise as neutron detectors for characterizing special nuclear materials in various arms-control and homeland security applications. Recent advances have yielded a new plastic scintillator - EJ299-33 - with pulse-shape-discrimination (PSD) capability. Plastic scintillators would have a much expanded range of deployment relative to liquids and crystals. Here in this paper, we present a full characterization of pulse height response to fission-energy neutrons for an EJ299-33 detector with 7.62-by-7.62-cm cylindrical active volume, and compare with an EJ309 liquid scintillator in the same assembly. Scintillation light output relations, energy resolutions, and response matrices are presented for both detectors. A Continuous spectrum neutron source, obtained via the bombardment of 27 Al with 7.44-MeV deuterons at the Edwards Accelerator Facility at Ohio University, was used for the measurement. A new procedure for evaluating and comparing PSD performance is presented which accounts for the effect of the light output relation on the ability to detect low energy neutrons. The EJ299-33 is shown to have considerable deficit in matrix condition, and in PSD figure of merit when compared to EJ309, especially when neutron energy is taken into account. Furthermore the EJ299 is likely to bring a modest PSD capability into a array of held applications that are not accessible to liquids or crystals.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

NEW ABUNDANCE DETERMINATIONS OF CADMIUM, LUTETIUM, AND OSMIUM IN THE r-PROCESS ENRICHED STAR BD +17 3248 {sup ,}

We report the detection of Cd I (Z = 48), Lu II (Z = 71), and Os II (Z = 76) in the metal-poor star BD +17 3248. These abundances are derived from an ultraviolet spectrum obtained with the Space Telescope Imaging Spectrograph on the Hubble Space Telescope. This is the first detection of these neutron-capture species in a metal-poor star enriched by the r process. We supplement these measurements with new abundances of Mo I, Ru I, and Rh I derived from an optical spectrum obtained with the High Resolution Echelle Spectrograph on Keck. Combined with previous abundance derivations, 32 neutron-capture elements have been detected in BD +17 3248, the most complete neutron-capture abundance pattern in any metal-poor star to date. The light neutron-capture elements (38 {<=} Z {<=} 48) show a more pronounced even-odd effect than expected from current solar system r-process abundance predictions. The age for BD +17 3248 derived from the Th II/Os II chronometer is in better agreement with the age derived from other chronometers than the age derived from Th II/Os I. New Hf II abundance derivations from transitions in the ultraviolet are lower than those derived from transitions in the optical, and the lower Hf abundance is in better agreement with the scaled solar system r-process distribution.

79 ASTRONOMY AND ASTROPHYSICS↗

Science & Technology Review April/May 2009

This month's issue has the following articles: (1) Leveraging the National Ignition Facility to Meet the Climate-Energy Challenge--Commentary by George H. Miller; (2) The Journey into a New Era of Scientific Discoveries--The world's largest laser is dedicated on May 29, 2009; (3) Safe and Sustainable Energy with LIFE--A revolutionary technology to generate electricity, modeled after the National Ignition Facility, could either be a pure fusion energy source or combine the best of fusion and fission energy; (4) A Simulated Rehearsal for Battle--Livermore's Joint Conflict and Tactical Simulation is the most widely used tactical model in the world; (5) Improving Catalysis with a 'Noble' Material--By infusing carbon aerogels with platinum, researchers have produced a more affordable and efficient catalytic material; and (6) A Time Machine for Fast Neutrons--A new, robust time-projection chamber that provides directional detection of fast neutrons could greatly improve search methods for nuclear materials.

42 ENGINEERING↗

Image plate multi-scan response to fusion protons in the range of 1–14 MeV

Image plates (IPs) are a quickly recoverable and reusable radiation detector often used to measure proton and x-ray fluence in laser-driven experiments. Recently, IPs have been used in a proton radiography detector stack on the OMEGA laser, a diagnostic historically implemented with CR-39, or radiochromic film. The IPs used in this and other diagnostics detect charged particles, neutrons, and x-rays indiscriminately. IPs detect radiation using a photo-stimulated luminescence (PSL) material, often phosphor, in which electrons are excited to metastable states by ionizing radiation. Protons at MeV energies deposit energy deeper into the IP compared with x rays below ∼20 keV due to the Bragg peak present for protons. This property is exploited to discriminate between radiation types. Doses of mono-energetic protons between 1.7 and 14 MeV are applied to IPs using the MIT linear electrostatic ion accelerator. This paper presents the results from consecutive scans of IPs irradiated with different proton energies. The PSL ratios between subsequent scans are shown to depend on proton energy, with higher energy protons having lower PSL ratios for each scan. This finding is separate from the known energy dependence in the absolute sensitivity of IPs. The results can be compared to complimentary work on x rays, showing a difference between protons and x rays, forging a path to discriminate between proton and x-ray fluence in mixed radiation environments.

Instruments & Instrumentation↗

Detectability of Martian carbonates from orbit using thermal neutrons

Numerical simulations of Martian neutron leakage flux spectra are made in order to explore the detectability of magnesium and calcium carbonate deposits using neutron spectroscopic techniques from orbit. The primary signature of such deposits is found to be an enhanced thermal amplitude. Although this enhancement is weakened by: (1) partial burial beneath an aeolian regolith blanket; (2) admixture with regolith on a microscopic (centimeter) or macroscopic (tens of centimeters) scale; and (3) reduction in the areal size of the deposit, near-surface stratigraphies of carbonates hypothesized by some authors as possible on Mars are still detectable by simple neutron sensors from orbit. However, the large variations in the magnitude of the thermal neutron enhancements caused by different carbonate deposit configurations found in this study require a combined gamma ray and neutron analysis for their unique specification.

Feldman, W. C.↗

Simulations of Neutron Time-of-Flight Method by Inelastic Scattering Carbon-12 using MCNP6 and Geant4

A neutron spectroscopy technique using neutron time-of-flight (TOF) with gamma tagging from inelastic scattering on carbon-12 was examined using MCNP6 and Geant4. Experimental data for the 12 C(n,n'$γ$) reaction from D. Spaargaren and C.C. Jonken was used to supplement the simulations due to their limitations with modeling correlated particles on an event-by-event basis. The MCNP and Geant4 models relied on different methods to determine the efficiencies and were compared against each other for validation of the results. The total efficiency of coincident detection as determined by MCNP is around 6.32E-11. That is, around 6 events will be detected per 100 billion source neutrons. It was found that the amount of neutrons which lose energy to elastic scattering is not negligible, and efforts to reconstruct the beam energy from the detected neutrons must take this into account. Running on 40 computer cores in multi-threading mode, the Geant4 model could simulate about half a billion source neutrons per hour. In the absence of biasing methods, Geant4 can not simulate the efficiency in any reasonable amount of time given current computing power. Further efforts will be made to introduce biasing to the simulation to verify the MCNP results.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Photon and neutron interrogation techniques for chemical explosives detection in air cargo: A critical review

Scanning cargo transported via aircraft ("air cargo") for explosive threats is a problem that, at present, lacks a comprehensive technical solution. While explosives detection in the baggage-scanning domain has a rich history that sheds light on potential solutions for air cargo, baggage scanning differs in several ways and thus one cannot look to the present array of technologies. Some contemporary solutions, like trace analysis, are not readily applied to cargo due to sampling challenges while the larger geometry of air cargo makes others less effective. This review article examines an array of interrogation techniques using photons and neutrons as incident particles. We first present a summary of the signatures and observables explosives provide and review how they have been exploited in baggage scanning. Following this is a description of the challenges posed by the air cargo application space. After considering interrogation sources, methods focused on transmission imaging, sub-surface examination and elemental characterization are described. It is our goal to shed light on the technical promise of each method while largely deferring questions that revolve around footprint, safety and conduct of operations. Our overarching intent is that a comprehensive understanding of potential techniques will foster development of a comprehensive solution.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The prototype of a detector for monitoring the cosmic radiation neutron flux on ground

This work presents a comparison between the results of experimental tests and Monte Carlo simulations of the efficiency of a detector prototype for on-ground monitoring the cosmic radiation neutron flux. The experimental tests were made using one conventional {sup 241}Am-Be neutron source in several incidence angles and the results were compared to that ones obtained with a Monte Carlo simulation made with MCNPX Code.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

USE OF PORTABLE GAMMA SPECTROMETERS FOR IDENTIFYING PERSONS EXPOSED IN A NUCLEAR CRITICALITY

At Y-12 triage-style assessments are used to identify persons potentially exposed to high doses from criticality accident radiations using portable instruments by assessing the presence of activated sodium atoms in a person's blood. Historically, simple hand-held Geiger-Mueller (G-M) probes were used for these purposes although it was recognized that, since these instruments contain no information on incident photon energy, it was impossible to differentiate between photons emitted by contamination on the potentially exposed worker from activation of sodium in the person s blood. This works examines the use of a portable gamma spectrometer for assessing blood sodium activation. Irradiations of a representative phantom were performed using two neutron source configurations (unmoderated and polyethylene-moderated 252Cf) and measurements were made using the spectrometer and a G-M detector following irradiation. Detection limits in terms of personnel neutron dose are given for two neutron fields representing metaland solution criticality spectra. Both Geiger-Mueller and spectrometer results indicate a low minimum detectable neutron dose indicating that both instrument are useful as an emergency response instrument. The spectrometer has the added benefit of discriminating between surface contamination and blood sodium activation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Generalized method for the optimization of pulse shape discrimination parameters

Organic scintillators exhibit fast timing, high detection efficiency for fast neutrons and pulse shape discrimination (PSD) capability. PSD is essential in mixed radiation fields, where different types of radiation need to be detected and discriminated. In neutron measurements for nuclear security and non proliferation effective PSD is crucial, because a weak neutron signature needs to be detected in the presence of a strong gamma-ray background. Here, the most commonly used deterministic PSD technique is charge integration (CI). This method requires the optimization of specific parameters to obtain the best gamma-neutron separation. These parameters depend on the scintillating material and light readout device and typically require a lengthy optimization process and a calibration reference measurement with a mixed source. In this paper, we propose a new method based on the scintillation fluorescence physics that enables to find the optimum PSD integration gates using only a gamma-ray emitter. We demonstrate our method using three organic scintillation detectors: deuterated trans-stilbene, small-molecule organic glass, and EJ-309. In all the investigated cases, our method allowed finding the optimum PSD CI parameters without the need of iterative optimization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Automating Anomaly Detection for Target systems at Spallation Neutron Source

The Spallation Neutron Source (SNS) at Oak Ridge National Laboratory, produces the world’s most intense pulse neutrons beams. An accelerated proton beam is directed into a mercury target to generate neutrons via spallation. The target system accounted for over 40% of the overall downtime of the facility in 2022. Thus, early detection in anomalies in the target systems can enable taking corrective actions to avoid failures and reduce downtime. Fault prognostics and anomaly detection in accelerators, both at SNS and outside, has largely focused on the beam side. This paper presents one the first studies exploring leveraging machine learning to automate the detection of anomalies in the target system. The target system consists of over 30 different interconnected subsystems, and the present work focuses on the mercury process system as a use case. Analyzing data from 28 process variables from 2022 and 2023, tree-based and reconstruction-based algorithms are employed to detect anomalies in archived data. The algorithms detected previously unreported anomalies, several of which were deemed alert worthy by human experts, particularly those found by reconstruction-based algorithms. Using data from each production run in the accelerator increased the generalizability of the models in time. Efforts are now underway to implement a workflow for incorporating human feedback to update the models and evaluating performance on unseen data. The models will eventually be integrated into the existing System Tracking and Reliability system with a web interface for automated anomaly detection and reporting along with a pathway for incorporating human feedback for model updates.

Raj, Anant [ORNL] (ORCID:0000000306711244)↗

The Single-Volume Scatter Camera

The multi-institution Single-Volume Scatter Camera (SVSC) collaboration led by Sandia National Laboratories (SNL) is developing a compact, high-efficiency double-scatter neutron imaging system. Kinematic emission imaging of fission-energy neutrons can be used to detect, locate, and spatially characterize special nuclear material. Neutron-scatter cameras, analogous to Compton imagers for gamma ray detection, have a wide field of view, good event-by-event angular resolution, and spectral sensitivity. Existing systems, however, suffer from large size and/or poor efficiency. We are developing high-efficiency scatter cameras with small form factors by detecting both neutron scatters in a compact active volume. This effort requires development and characterization of individual system components, namely fast organic scintillators, photodetectors, electronics, and reconstruction algorithms. In this presentation, we will focus on characterization measurements of several SVSC candidate scintillators. The SVSC collaboration is investigating two system concepts: the monolithic design in which isotropically emitted photons are detected on the sides of the volume, and the optically segmented design in which scintillation light is channeled along scintillator bars to segmented photodetector readout. For each of these approaches, we will describe the construction and performance of prototype systems. We will conclude by summarizing lessons learned, comparing and contrasting the two system designs, and outlining plans for the next iteration of prototype design and construction.

Manfredi, Juan↗

Enriched Boron-Doped Amorphous Selenium Based Position-Sensitive Solid-State Thermal Neutron Detector for MPACT Applications

High-efficiency thermal neutron detectors with compact size, low power-rating and high spatial, temporal and energy resolution are essential to execute non-proliferation and safeguard protocols. The demands of such detector are not fully covered by the current detection system such as gas proportional counters or scintillator-photomultiplier tube combinations, which are limited by their detection efficiency, stability of response, speed of operation, and physical size. Furthermore, world-wide shortage of 3 He gas, required for widely used gas detection method, has further prompted to design an alternative system. Therefore, a solid-state neutron detection system without the requirement of 3 He will be very desirable. To address the above technology gap, we had proposed to develop new room temperature solidstate thermal neutron detectors based on enriched boron ( 10 B) and enriched lithium ( 6 Li) doped amorphous Se (As- 0.52%, Cl 5 ppm) semiconductor for MPACT applications. The proposed alloy materials have been identified for its many favorable characteristics - a wide bandgap (~2.2 eV at 300 K) for room temperature operation, high glass transition temperature (t g ~ 85°C), a high thermal neutron cross-section (for boron ~ 3840 barns, for lithium ~ 940 barns, 1 barn = 10 -24 cm 2 ), low effective atomic number of Se for small gamma ray sensitivity, and high radiation tolerance due to its amorphous structure.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗