Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Measurement uncertainty”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

Induced Magnetic Fields in LBNF Horns and DUNE-PRISM Off-Axis Neutrinos

Deep Underground Neutrino Experiment (DUNE) is a next-generation, long-baseline neutrino oscillation experiment that will utilize an intense neutrino beam from Fermilab to measure neutrino oscillation parameters with unprecedented precision. The DUNE-PRISM near detector concept employs an off-axis measurement strategy to mitigate neutrino-nucleus interaction uncertainties; however, this approach relies critically on the accurate characterization of the neutrino flux. As statistical uncertainties are suppressed in the high-intensity Long Baseline Neutrino Facility (LBNF) beam, beamline focusing uncertainties, specifically those arising from focusing horn geometry, become an important systematic uncertainty source. This work presents Geant4 LBNF beam simulations quantifying one of the most important systematic uncertainties for off-axis fluxes: the impact of manufacturing tolerances in the LBNF horns. The focusing horns consist of coaxial inner and outer conductors. Ideally, the region inside the inner conductor is field-free, while the region between the inner and outer conductors serves as the focusing region, where the magnetic field follows a nominal $1/r$ dependence. However, inner conductor deformations such as eccentricity and ellipticity introduce asymmetry, inducing unintended magnetic fields inside the field-free region. Crucially, while the on-axis neutrino flux remains largely unaffected by these induced fields, the resulting flux fractional shifts become pronounced over a particular range of off-axis positions where the DUNE-PRISM program will perform measurements. Consequently, these inner conductor deformations can impact the precision of flux predictions, which could potentially degrade the sensitivity to oscillation parameters. Possible mitigation strategies for these effects will also be presented.

Bae, Yuri [U. Minnesota, Minneapolis (main)] (ORCI↗

The phase-2 particle x-ray temporal diagnostic for simultaneous measurement of multiple x-ray and nuclear emission histories from OMEGA implosions (invited)

Electron-temperature (T e ) measurements in implosions provide valuable diagnostic information, as T e is negligibly affected by residual flows and other non-thermal effects unlike ion-temperature inferred from a fusion product spectrum. In OMEGA cryogenic implosions, measurement of T e (t) can be used to investigate effects related to time-resolved hot-spot energy balance. The newly implemented phase-2 Particle X-ray Temporal Diagnostic (PXTD) utilizes four fast-rise (~15 ps) scintillator-channels with distinct x-ray filtering. Titanium and stepped aluminum filtering were chosen to maximize detector sensitivity in the 10–20 keV range, as it has been shown that these x rays have similar density and temperature weighting to the emitted deuterium–tritium fusion neutrons (DTn) from OMEGA Cryo-DT implosions. High quality data have been collected from warm implosions at OMEGA. These data have been used to infer spatially integrated T e (t) with <10% uncertainty at peak emission. Nuclear and x-ray emission histories are measured with 10 ps relative timing uncertainty for x rays and DTn and 12 ps for x rays and deuterium- 3 He protons (D 3 Hep). A future upgrade to the system will enable spatially integrated T e (t) with 40 ps time-resolution from cryogenic DT implosions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Results of an interlaboratory study on the working curve in vat photopolymerization

The working curve informs resin properties and print parameters for stereolithography, digital light processing, and other photopolymer additive manufacturing (PAM) technologies. First demonstrated in 1992, the working curve measurement of cure depth vs radiant exposure of light is now a foundational measurement in the field of PAM. Despite its widespread use in industry and academia, there is no formal method or procedure for performing the working curve measurement, raising questions about the utility of reported working curve parameters. Here, an interlaboratory study (ILS) is described in which 24 individual laboratories performed a working curve measurement on an aliquot from a single batch of PAM resin. The ILS reveals that there is enormous scatter in the working curve data and the key fit parameters derived from it. Further, the measured depth of light penetration D p varied by as much as 7x between participants, while the critical radiant exposure for gelation E c varied by as much as 70x. This significant scatter is attributed to a lack of common procedure, variation in light engines, epistemic uncertainties from the Jacobs equation, and the use of measurement tools with insufficient precision. The ILS findings highlight an urgent need for procedural standardization and better hardware characterization in this rapidly growing field.

36 MATERIALS SCIENCE↗

Absolute mass calibration of fission product distributions measured with the E-$v$ method

The mass calibration of fission product distributions measured with the energy–velocity (E-v) method constitutes a technical challenge. The energy loss of the fission fragments in the various dead layers of the spectrometer and other sources of pulse-height defects of the energy detectors are a significant source of systematic uncertainty in the mass calculations used to determine the measured fission product yields. Here, in this study, the absolute calibration of the fission mass distributions is accomplished by measuring prompt γ-rays in coincidence with the fission fragments. This allows for the direct calibration of the mass spectra and eliminates any dependence on potentially complicated energy corrections. The first test measurement was performed at the Los Alamos Neutron Science Center employing the SPectrometer for Ion DEtermination in fission Research (SPIDER). SPIDER is a 2E-2v spectrometer designed for measuring independent fission product yields from neutron-induced fission. In this test, the single-arm SPIDER (E-v) system and an array of 252 Cf sources were used. The single-arm system consisted of two time pick-off detectors for measuring the time-of-flight of the fission fragments and a double-sided silicon strip detector (DSSD) for measuring the kinetic energy. Characteristic γ-rays from fission fragments were detected using three high-purity germanium (HPGe) detectors. For the mass calibration, γ–mass coincidence events from twelve product isotopes were used. The measured FPYs from 252 Cf spontaneous fission were found to be in excellent agreement with the evaluated data after applying the absolute mass calibration. From the γ–mass coincidence events, the mass resolution of the system was also extracted. An average mass resolution of ~1.4 AMU (FWHM) for the light fragments and ~2.4 AMU (FWHM) for the heavy fragments were found. This was the first in-situ calibration and characterization of the SPIDER spectrometer, which paves the way for high-quality FPY measurements with this instrument.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron Cross Section Measurement In The Protodune-SP Experiment

Understanding the detector response to neutrons will be critical for performing neutrino oscillation analyses in the next-generation Deep Underground Neutrino Experiment (DUNE). The DUNE physics program is centered around measuring the neutrino flavor composition as a function of their energy both at the near and the far detector. Neutrinos in the DUNE beam will have energies ranging between 100~MeV and 10~GeV, which is significant, because individual neutrino energies will not be known beforehand and will have to be reconstructed. Neutrino interactions in DUNE will produce leptons and hadrons -- including protons, pions, and neutrons. Neutrons can transport energy away from their origin and sometimes go undetected. In addition to the primary neutrons produced by the neutrino, subsequent interactions of the charged hadrons can result in secondary neutrons. Neutrons are a source of missing energy and will bias the neutrino energy measurement. Currently, there is also a 20\% energy scale uncertainty and a 40\% uncertainty on the energy resolution for neutrons in DUNE, which must be addressed. ProtoDUNE Single-Phase (ProtoDUNE-SP) is a 770-ton prototype for the DUNE far detector and was designed to both validate the technology that will be employed in DUNE and to measure cross sections for the charged hadrons (pions, protons, and kaons) at the relevant energies for DUNE. The ProtoDUNE-SP experiment, therefore, is in a unique position to characterize the secondary neutron component for DUNE. This is achieved by searching for candidate neutron interactions in ProtoDUNE-SP events and using these to facilitate a measurement of the neutron inelastic cross section as well as an estimate of the neutron energy and number. The cross section measurement presented here is based on neutrons produced in 1~GeV, $\pi^+$ events captured in 2018 by ProtoDUNE-SP in accordance with the production and cross section models in the GEANT4 simulation toolkit, version 4.1 0.6p1. T he best-fit neutron inelastic cross section, in the kinetic energy range of 114 to 314~MeV, is $1.24_{-0.08}^{+0.10}$~(stat.~$\oplus$~syst.)~barns.

Rivera, David Orlando↗

Development of a direct-sampling RF receiver for precision beam charge measurements in the MOLLER experiment

Here, we have developed and tested a direct-sampling RF receiver capable of measuring the amplitude of a 1497 MHz sinusoidal beam signal in 0.5 ms integration windows with a relative uncertainty of better than 10 parts per million. The receiver is intended for measuring signals from beam current monitoring cavities on the beamline of the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab. The beam signal strength, frequency, and integration window fulfill the thus far unmet requirements of the upcoming MOLLER experiment to measure the beam charge for different helicity states.

47 OTHER INSTRUMENTATION↗

A round-robin approach provides a detailed assessment of biomolecular small-angle scattering data reproducibility and yields consensus curves for benchmarking

Through an expansive international effort that involved data collection on 12 small-angle X-ray scattering (SAXS) and four small-angle neutron scattering (SANS) instruments, 171 SAXS and 76 SANS measurements for five proteins (ribonuclease A, lysozyme, xylanase, urate oxidase and xylose isomerase) were acquired. From these data, the solvent-subtracted protein scattering profiles were shown to be reproducible, with the caveat that an additive constant adjustment was required to account for small errors in solvent subtraction. Further, the major features of the obtained consensus SAXS data over the q measurement range 0–1 Å −1 are consistent with theoretical prediction. The inherently lower statistical precision for SANS limited the reliably measured q -range to <0.5 Å −1 , but within the limits of experimental uncertainties the major features of the consensus SANS data were also consistent with prediction for all five proteins measured in H 2 O and in D 2 O. Thus, a foundation set of consensus SAS profiles has been obtained for benchmarking scattering-profile prediction from atomic coordinates. Additionally, two sets of SAXS data measured at different facilities to q > 2.2 Å −1 showed good mutual agreement, affirming that this region has interpretable features for structural modelling. SAS measurements with inline size-exclusion chromatography (SEC) proved to be generally superior for eliminating sample heterogeneity, but with unavoidable sample dilution during column elution, while batch SAS data collected at higher concentrations and for longer times provided superior statistical precision. Careful merging of data measured using inline SEC and batch modes, or low- and high-concentration data from batch measurements, was successful in eliminating small amounts of aggregate or interparticle interference from the scattering while providing improved statistical precision overall for the benchmarking data set.

59 BASIC BIOLOGICAL SCIENCES↗

Combining synchrotron X-ray diffraction, mechanistic modeling and machine learning for in situ subsurface temperature quantification during laser melting

Laser melting, such as that encountered during additive manufacturing, produces extreme gradients of temperature in both space and time, which in turn influence microstructural development in the material. Qualification and model validation of the process itself and the resulting material necessitate the ability to characterize these temperature fields. However, well established means to directly probe the material temperature below the surface of an alloy while it is being processed are limited. To address this gap in characterization capabilities, a novel means is presented to extract subsurface temperature-distribution metrics, with uncertainty, from in situ synchrotron X-ray diffraction measurements to provide quantitative temperature evolution data during laser melting. Temperature-distribution metrics are determined using Gaussian process regression supervised machine-learning surrogate models trained with a combination of mechanistic modeling (heat transfer and fluid flow) and X-ray diffraction simulation. The trained surrogate model uncertainties are found to range from 5 to 15% depending on the metric and current temperature. The surrogate models are then applied to experimental data to extract temperature metrics from an Inconel 625 nickel superalloy wall specimen during laser melting. The maximum temperatures of the solid phase in the diffraction volume through melting and cooling are found to reach the solidus temperature as expected, with the mean and minimum temperatures found to be several hundred degrees less. The extracted temperature metrics near melting are determined to be more accurate because of the lower relative levels of mechanical elastic strains. However, uncertainties for temperature metrics during cooling are increased due to the effects of thermomechanical stress.

36 MATERIALS SCIENCE↗

A LENS on DUNE-PRISM: Characterizing a Neutrino Beam with Off-Axis Measurements

Upcoming precision long-baseline neutrino oscillation experiments will be severely limited by the large systematic uncertainties associated with neutrino flux predictions and neutrino--nucleus cross sections. A promising remedy is the PRISM (Precision Reaction Independent Spectrum Measurement) technique, whereby the near detector measures the neutrino spectrum at different angles with respect to the beam axis. These measurements are then linearly combined into a prediction of the oscillated neutrino flux at the far detector. This prediction is data-driven, but still dependent on some theoretical knowledge about the neutrino flux. In this paper, we study to what extent off-axis measurements themselves can be used to directly constrain neutrino flux models. In particular, we use them to extract separately the fluxes and spectra of different meson species in the beam. We call this measurement LENS (Lateral Extraction of Neutrino Spectra). Second, we demonstrate how the thus improved flux model helps to further constrain the far detector flux prediction, thereby ultimately improving oscillation measurements.

FOS: Physical sciences↗

Measurement of Nuclear Dependence in Inclusive Antineutrino Scattering

One of the fundamental questions in physics is the matter-antimatter asymmetry of the Universe, explored through charge-parity violation searches in neutrino oscillation experiments. Next-generation oscillation experiments like DUNE need to constrain the systematic uncertainties arising from our understanding of (anti)neutrino-nucleus scattering to within a few percent to achieve their physics goals. MINERvA, a dedicated (anti)neutrino-nucleus scattering experiment, plays a crucial role in constraining these uncertainties. This thesis presents MINERvA's first high-statistics direct measurement of nuclear dependence in charged-current inclusive antineutrino scattering on carbon, hydrocarbon, iron, and lead as a function of antimuon transverse momentum, $p_{\text{T}}$, and Bjorken~$x$. The analysis utilises interactions with a mean antineutrino energy of approximately~6~GeV, with reconstructed antimuons having a scattering angle of less than 17$^\circ$ relative to the antin eutrino beam and an antimuon energy of 2--20 GeV. The measured per-nucleon differential cross-sections are reported with a precision of 7--9\%, while the cross-section ratios of carbon, iron, and lead to hydrocarbon have uncertainties of 5\% or less. The cross-sections for iron and lead indicate strong suppression at low $p_{\text{T}}$ and Bjorken~$x$, and an enhancement at high $p_{\text{T}}$. These effects are observed to be more pronounced with the increasing size of the target nucleus and are not reproduced by the underlying simulation prediction. Comparisons to alternative models used in current (anti)neutrino interaction generators show some improvements in modelling over the base prediction model, yet they are still unable to fully reproduce the observed nuclear dependence in this analysis. Importantly, the analysis provides a direct test of nuclear effects in inclusive antineutrino scattering, with major contributions from resonant pion production, deep inelastic scattering, and the transition region between these channels, which will be significant in DUNE. This measurement also represents one of the largest antineutrino datasets in this energy regime analysed to date.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Run 2/3 measurement of the muon anomalous magnetic moment by the Muon g-2 experiment at Fermilab

The Muon g-2 experiment at Fermilab seeks to measure the muon magnetic moment anomaly, $a_μ=(g-2)/2$, with a final target precision of 0.14 parts-per-million (ppm). The experiment's initial result, published in 2021 using Run 1 data from 2018, confirmed the previous measurement at Brookhaven National Laboratory with a comparable sensitivity of 0.46 ppm. In 2023, a new result based on Run 2 and Run 3 data, collected in 2019 and 2020, was released. These datasets contain four times the data from Run 1, significantly enhancing sensitivity and achieving an unprecedented uncertainty of 0.20 ppm. This advancement resulted in a two-fold improvement in both statistical and systematic uncertainties. Here, we will discuss the muon $g-2$ measurement, the increased precision relative to the Run 1 result, and provide an outlook on future measurements which will incorporate datasets from 2021 to 2023. Additionally, we will explore the implications of comparing the new measurements with the latest Standard Model predictions for muon g-2.

Zaid, Estifa'a [Liverpool U.]↗

SILVERRUSH. XIV. Ly α Luminosity Functions and Angular Correlation Functions from 20,000 Ly α Emitters at z ∼ 2.2–7.3 from up to 24 deg 2 HSC-SSP and CHORUS Surveys: Linking the Postreionization Epoch to the Heart of Reionization

Abstract We present luminosity functions (LFs) and angular correlation functions (ACFs) derived from 18,960 Ly α emitters (LAEs) at z = 2.2−7.3 over a wide survey area of ≲24 deg 2 that are identified in the narrowband data of the HSC-SSP and CHORUS surveys. Confirming the large sample with 241 spectroscopically identified LAEs, we determine Ly α LFs and ACFs in the brighter luminosity range down to 0.5 L ⋆ , and confirm that our measurements are consistent with previous studies but offer significantly reduced statistical uncertainties. The improved precision of our ACFs allows us to clearly detect one-halo terms at some redshifts, and provides large-scale bias measurements that indicate host halo masses of ∼10 11 M ⊙ over z ≃ 2−7. By comparing our Ly α LF (ACF) measurements with reionization models, we estimate the neutral hydrogen fractions in the intergalactic medium to be x H i < 0.05 (= 0.06 − 0.03 + 0.12 ) at z = 5.7 and x H i = 0.1 5 − 0.08 + 0.10 ( 0.21 − 0.14 + 0.19 ), 0.1 8 − 0.12 + 0.14 , and 0.7 5 − 0.13 + 0.09 at z = 6.6, 7.0, and 7.3, respectively. Our findings suggest that the neutral hydrogen fraction remains relatively low, x H i ≲ 0.2, at z = 5−7, but increases sharply at z > 7, reaching x H i ∼ 0.9 by z ≃ 8−9, as indicated by recent JWST studies. The combination of our results from LAE observations with recent JWST observations suggests that the major epoch of reionization occurred at z ∼ 7−8, likely driven by the emergence of massive sources emitting significant ionizing photons.

Umeda, Hiroya (ORCID:0009000801675129)↗

Measurement of branching fractions, C P asymmetry, and isospin asymmetry for B → ρ γ decays using Belle and Belle II data

We present measurements of B + → ρ + γ and B 0 → ρ 0 γ decays using a combined data sample of 772 × 10 6 B B ¯ pairs collected by the Belle experiment and 387 × 10 6 B B ¯ pairs collected by the Belle II experiment in e + e − collisions at the ϒ ( 4 S ) resonance. After an optimized selection, a simultaneous fit to the Belle and Belle II datasets yields 114 ± 12 B + → ρ + γ and 99 ± 12 B 0 → ρ 0 γ decays. The measured branching fractions are ( 13.1 − 1.9 − 1.2 + 2.0 + 1.3 ) × 10 − 7 and ( 7.6 ± 1.3 − 0.8 + 1.0 ) × 10 − 7 for B + → ρ + γ and B 0 → ρ 0 γ decays, respectively, where the first uncertainty is statistical and the second is systematic. We also measure the isospin asymmetry A I ( B → ρ γ ) = ( 10.9 − 11.7 − 7.3 + 11.2 + 7.8 ) % and the direct C P asymmetry A C P ( B + → ρ + γ ) = ( − 8.2 ± 15.2 − 1.3 + 2.0 ) % . Published by the American Physical Society 2025

Adachi, I. (ORCID:0000000322870173)↗

Three-dimensional phenotyping of peach tree-crown architecture utilizing terrestrial laser scanning

Tree training systems for temperate fruit have been developed throughout history by pomologists to improve light interception, fruit yield, and fruit quality. These training systems direct crown and branch growth to specific configurations. Quantifying crown architecture could aid the selection of trees that require less pruning or that naturally excel in specific growing/training system conditions. Regarding peaches [Prunus persica (L.) Batsch], access tools such as branching indices have been developed to characterize tree-crown architecture. However, the required branching data (BD) to develop these indices are difficult to collect. Traditionally, BD have been collected manually, but this process is tedious, time-consuming, and prone to human error. These barriers can be circumnavigated by utilizing terrestrial laser scanning (TLS) to obtain a digital twin of the real tree. TLS generates three-dimensional (3D) point clouds of the tree crown, wherein every point contains 3D coordinates (x, y, z). To facilitate the use of these tools for peach, we selected 16 young peach trees scanned in 2021 and 2022. These 16 trees were then modeled and quantified using the open-source software TreeQSM. As a result, “in silico” branching and biometric data for the young peach trees were calculated to demonstrate the capabilities of TLS phenotyping of peach tree-crown architecture. The comparison and analysis of field measurements (in situ) and in silico BD, biometric data, and quantitative structural model branch uncertainty data were utilized to determine the reconstructive model’s reliability as a source substitute for field measurements. Mean average deviation when comparing young tree (YT) height was approx. 5.93%, with crown volume was approx. 13.26% across both 2021 and 2022. All point clouds of the YTs in 2022 showed residuals lower than 12 mm to cylinders fitted to all branches, and mean surface coverage greater than 40% for both the trunk and primary branching orders.

09 BIOMASS FUELS↗

Exploring the Potential of Using Carbonyl Sulfide to Track the Urban Biosphere Signal

Abstract Cities are implementing additional urban green as a means to capture CO 2 and become more carbon neutral. However, cities are complex systems where anthropogenic and natural components of the CO 2 budget interact with each other, and the ability to measure the efficacy of such measures is still not properly addressed. There is still a high degree of uncertainty in determining the contribution of the vegetation signal, which furthermore confounds the use of CO 2 mole fraction measurements for inferring anthropogenic emissions of CO 2 . Carbonyl sulfide (OCS) is a tracer of photosynthesis which can aid in constraining the biosphere signal. This study explores the potential of using OCS to track the urban biosphere signal. We used the Sulfur Transport and dEposition Model (STEM) to simulate the OCS concentrations and the Carnegie Ames Stanford Approach ecosystem model to simulate global CO 2 fluxes over the Bay Area of San Francisco during March 2015. Two observation towers provided measurements of OCS and CO 2 : The Sutro tower in San Francisco (upwind from the area of study providing background observations), and a tower located at Sandia National Laboratories in Livermore (downwind of the highly urbanized San Francisco region). Our results show that the STEM model works better under stable marine influence, and that the boundary layer height and entrainment are driving the diurnal changes in OCS and CO 2 at the downwind Sandia site. However, the STEM model needs to better represent the transport and boundary layer variability, and improved estimates of gross primary productivity for characterizing the urban biosphere signal are needed.

54 ENVIRONMENTAL SCIENCES↗

High-precision measurement of the W boson mass with the CMS experiment

In the standard model of particle physics, the masses of the W and Z bosons, the carriers of the weak interaction, are uniquely related. A precise determination of their masses is important because quantum loops of heavy, undiscovered particles could modify this relationship. Although the Z mass is known to the remarkable precision of 22 parts per million (2.0 MeV), the W mass is known much less precisely. A global fit to measured electroweak observables predicts the W mass with 6 MeV uncertainty [1$-$3]. Reaching a comparable experimental precision would be a sensitive and fundamental test of the standard model, made even more urgent by a recent challenge to the global fit prediction by a measurement from the CDF Collaboration at the Fermilab Tevatron collider [4]. Here we report the measurement of the W mass by the CMS Collaboration at the CERN LHC, based on a large data sample of $W \to \mu \nu$ events collected in 2016 at the proton-proton collision energy of 13 TeV. The measurement exploits a high-granularity maximum likelihood fit to the kinematic properties of muons produced in W decays. By combining an accurate determination of experimental effects with marked in situ constraints of theoretical inputs, we reach a precise measurement of the W mass, of 80 360.2 $\pm$ 9.9 MeV, in agreement with the standard model prediction.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Demonstration of Autonomous Emittance Characterization at the Argonne Wakefield Accelerator

Transverse beam emittance plays a key role in the performance of high-brightness accelerators. Characterizing beam emittance is often carried out using a quadrupole scan, which fits beam matrix elements to experimental measurements using first-order beam dynamics. Despite its simplicity at face value, this procedure is difficult to automate due to practical limitations. Key issues that must be addressed include maintaining beam size measurement validity by keeping beams within the radius of diagnostic screens, ensuring that measurement fitting produces physically valid results, and accurately characterizing emittance uncertainty. We describe a demonstration of the Bayesian exploration technique towards solving this problem at the Argonne Wakefield Accelerator, enabling a turn-key, autonomous quadrupole scan tool that can be used to quickly measure beam emittances at various locations in accelerators with limited operator input.

Roussel, Ryan↗

Dual-frequency (Ka-band and G-band) radar estimates of liquid water content profiles in shallow clouds

The profile of the liquid water content (LWC) in clouds provides fundamental information for understanding the internal structure of clouds, their radiative effects, propensity to precipitate, and degree of entrainment and mixing with the surrounding environment. In principle, differential absorption techniques based on coincident dual-frequency radar reflectivity observations have the potential to provide the LWC profile. Previous differential frequency radar reflectivity (DFR) efforts were challenged by the fact that the measurable differential attenuation for small quantities of LWC is usually comparable to the system measurement error. This typically renders the retrieval impractical, as the uncertainty can become many times greater than the retrieved value itself. Theoretically, this drawback can be mitigated following two interconnected approaches: (1) increasing the frequency separation between the dual-frequency radar system to measure greater differential attenuation and (2) increasing the radar operating frequency to reduce the instrument measurement random error. Our recently developed 239 GHz radar was deployed during the Eastern Pacific Cloud Aerosol Precipitation Experiment (EPCAPE) along with a variety of collocated remote sensing and in situ instruments. We have combined Ka-band (35 GHz) and G-band (239 GHz) observations to retrieve the LWC from more than 100 vertical profiles of shallow clouds with typical amounts of LWC smaller than 1 g m -3 . We theoretically and experimentally demonstrate that the Ka-band and G-band pair of frequencies offers at least a 65 % relative improvement in the LWC retrieval sensitivity compared to previous works reported in the literature using lower-frequency radars. This new technique provides a missing capability to determine the LWC in the challenging low liquid water path (LWP) range (< 200 g m -2 ) and suggests a way forward to characterize microphysical and dynamical processes more precisely in shallow clouds.

54 ENVIRONMENTAL SCIENCES↗